924 resultados para Partition coefficient
Resumo:
Desalination is considered one of the most suitable areas for the utilization of solar energy, as there are many places in the world where abundant supply of solar energy is available and also there is a great demand for fresh water. An integrated solar heat pump desalination system has been developed at the National University of Singapore. The system also offers the opportunity of water heating and drying utilizing solar, ambient energy and waste heat from air conditioning system, which is conventionally dumped into the environment causing global warming. Desalination is carried out by making use of a single effect of Multi-Effect Distillation (MED) system. Within the desalination chamber, both fl ashing and evaporation of saline water take place. The maximum Coefficient of Performance (COP) of the heat pump system was around 5.8. In the integrated system, the maximum fresh water production rate was 9.6 l h−1 and a Performance Ratio (PR) of 1.2. For only desalination, the system has the potential to produce a maximum of 30 l h−1 of fresh water.
Resumo:
A numerical time-dependent model of an active magnetic regenerator (AMR) was developed for cooling in the kilowatt range. Earlier numerical models have been mostly developed for cooling power in the 0.4 kW range. In contrast, this paper reports the applicability of magnetic refrigeration to the 50 kW range. A packed bed active magnetic regenerator was modelled and the influence of parameters such as geometry and operating parameters were studied for different geometries. The pressure drop for AMR bed length and particle diameter was also studied. High cooling power and coefficient of performance (COP) were achieved by optimization of the diameter of the magnetocaloric powder particles and operating frequency. The optimum operating conditions of the AMR for a cooling capacity of 50 kW was determined for a temperature span of 15 K. The predicted coefficient of performance (COP) was found to be ∼6, making it an attractive alternative to vapour compression systems.
Resumo:
In view of the growing global demand for energy and concern expressed for environmental degradation, a clean and "free" energy source, such as solar energy, has been receiving greater attention in recent years for various applications using different techniques. The Direct Expansion Solar Assisted Heat Pump (DX-SAHP) principle is one of the most promising techniques as it makes use of both solar and ambient energy. As the system has capability to function at low temperatures, it has the potential to operate at night in the tropics. The system utilizes multi-effect distillation (MED) principle for the conversion of seawater to fresh water. An experimental setup of the DX-SAHP desalination system has been built at the Department of Mechanical Engineering, National University of Singapore (NUS). This system uses two types of flat-plate solar collectors. One is called evaporator-collector, where no glazing is used, and the efficiency varies between 80 and 90%. The other type of collector is single-glazed, where the maximum efficiency is about 60%, and it is used for feed water heating. For the heat pump cycle, refrigerant R134a is used. The present study provides a comprehensive analyses and performance evaluation of this system under different operating and meteorological conditions of Singapore. The Coefficient of Performance (COP) of the heat pump system reached a maximum value of 10. For a single effect of desalination, the system shows a Performance Ratio (PR) of around 1.3.
Resumo:
Cold-formed high strength steel members are increasingly used as primary load bearing components in low rise buildings. Lipped channel beam (LCB) is one of the most commonly used flexural members in these applications. In this research an experimental study was undertaken to investigate the shear behaviour and strengths of LCB sections. Simply supported test specimens of back to back LCBs with aspect ratios of 1.0 and 1.5 were loaded at mid-span until failure. Test specimens were chosen such that all three types of shear failure (shear yielding, inelastic and elastic shear buckling) occurred in the tests. The ultimate shear capacity results obtained from the tests were compared with the predictions from the current design rules in Australian/NewZealand and American cold-formed steel design standards. This comparison showed that these shear design rules are very conservative as they did not include the post-buckling strength observed in the shear tests and the higher shear buckling coefficient due to the additional fixity along the web-flange juncture. Improved shear design equations are proposed in this paper by including the above beneficial effects. Suitable lower bound design rules were also developed under the direct strength method format. This paper presents the details of this experimental study and the results including the improved design rules for the shear capacity of LCBs. It also includes the details of tests of LCBs subject to combined shear and flange distortion, and combined bending and shear actions, and proposes suitable design rules to predict the capacities in these cases.
Resumo:
Background Designing novel proteins with site-directed recombination has enormous prospects. By locating effective recombination sites for swapping sequence parts, the probability that hybrid sequences have the desired properties is increased dramatically. The prohibitive requirements for applying current tools led us to investigate machine learning to assist in finding useful recombination sites from amino acid sequence alone. Results We present STAR, Site Targeted Amino acid Recombination predictor, which produces a score indicating the structural disruption caused by recombination, for each position in an amino acid sequence. Example predictions contrasted with those of alternative tools, illustrate STAR'S utility to assist in determining useful recombination sites. Overall, the correlation coefficient between the output of the experimentally validated protein design algorithm SCHEMA and the prediction of STAR is very high (0.89). Conclusion STAR allows the user to explore useful recombination sites in amino acid sequences with unknown structure and unknown evolutionary origin. The predictor service is available from http://pprowler.itee.uq.edu.au/star.
Resumo:
We present a machine learning model that predicts a structural disruption score from a protein s primary structure. SCHEMA was introduced by Frances Arnold and colleagues as a method for determining putative recombination sites of a protein on the basis of the full (PDB) description of its structure. The present method provides an alternative to SCHEMA that is able to determine the same score from sequence data only. Circumventing the need for resolving the full structure enables the exploration of yet unresolved and even hypothetical sequences for protein design efforts. Deriving the SCHEMA score from a primary structure is achieved using a two step approach: first predicting a secondary structure from the sequence and then predicting the SCHEMA score from the predicted secondary structure. The correlation coefficient for the prediction is 0.88 and indicates the feasibility of replacing SCHEMA with little loss of precision.
Resumo:
PURPOSE Every health care sector including hospice/palliative care needs to systematically improve services using patient-defined outcomes. Data from the national Australian Palliative Care Outcomes Collaboration aims to define whether hospice/palliative care patients' outcomes and the consistency of these outcomes have improved in the last 3 years. METHODS Data were analysed by clinical phase (stable, unstable, deteriorating, terminal). Patient-level data included the Symptom Assessment Scale and the Palliative Care Problem Severity Score. Nationally collected point-of-care data were anchored for the period July-December 2008 and subsequently compared to this baseline in six 6-month reporting cycles for all services that submitted data in every time period (n = 30) using individual longitudinal multi-level random coefficient models. RESULTS Data were analysed for 19,747 patients (46 % female; 85 % cancer; 27,928 episodes of care; 65,463 phases). There were significant improvements across all domains (symptom control, family care, psychological and spiritual care) except pain. Simultaneously, the interquartile ranges decreased, jointly indicating that better and more consistent patient outcomes were being achieved. CONCLUSION These are the first national hospice/palliative care symptom control performance data to demonstrate improvements in clinical outcomes at a service level as a result of routine data collection and systematic feedback.
Resumo:
Objectives: Examine the association between food insecurity (FI) and physical activity (PA) in the U.S. population. Methods: Accelerometry (PAM) and self-report PA (PAQ) data from NHANES 2003-2006 were used. Those aged less than six years or were older than 65 years, pregnant, with physical limitations, or with family income above 350% of the poverty line were excluded. FI was measured by the USDA Household Food Security Survey Module. Crude and adjusted odd ratios were calculated from logistic regression to identify the association between FI and adherence to the PA recommendation. Crude and adjusted coefficients were calculated from linear regression to identify the association between FI and both sedentary and activity minutes. Results: In children, FI was not associated with adherence to PA recommendation measured via PAM or PAQ (p>0.05) but was significantly associated with sedentary minutes (adjusted coefficient=10.74, one-sided p<0.05). Food-insecure children did less moderate-to-vigorous PA than did food-secure children (adjusted coefficient = -5.31, p = 0.032). In adults, FI was significantly associated with PA (adjusted OR=0.722 for PAM and OR=0.839 for PAQ, one-sided p<0.05) but not associated with sedentary minutes (p>0.05) Conclusions: FI children were more sedentary and FI adults were less likely to adhere to the PA recommendation than those without FI.
Resumo:
Background Household food insecurity and physical activity are each important public-health concerns in the United States, but the relation between them was not investigated thoroughly. Objective We wanted to examine the association between food insecurity and physical activity in the U.S. population. Methods Physical activity measured by accelerometry (PAM) and physical activity measured by questionnaire (PAQ) data from the NHANES 2003–2006 were used. Individuals aged <6 y or >65 y, pregnant, with physical limitations, or with family income >350% of the poverty line were excluded. Food insecurity was measured by the USDA Household Food Security Survey Module. Adjusted ORs were calculated from logistic regression to identify the association between food insecurity and adherence to the physical-activity guidelines. Adjusted coefficients were obtained from linear regression to identify the association between food insecurity with sedentary/physical-activity minutes. Results In children, food insecurity was not associated with adherence to physical-activity guidelines measured via PAM or PAQ and with sedentary minutes (P > 0.05). Food-insecure children did less moderate to vigorous physical activity than food-secure children (adjusted coefficient = −5.24, P = 0.02). In adults, food insecurity was significantly associated with adherence to physical-activity guidelines (adjusted OR = 0.72, P = 0.03 for PAM; and OR = 0.84, P < 0.01 for PAQ) but was not associated with sedentary minutes (P > 0.05). Conclusion Food-insecure children did less moderate to vigorous physical activity, and food-insecure adults were less likely to adhere to the physical-activity guidelines than those without food insecurity.
Resumo:
This paper describes the electrocatalytic oxidation of ascorbic acid (AA) in phosphate buffer solution by the immobilized citrate capped gold nanoparticles (AuNPs) on 1,6-hexanedithiol (HDT) modified Au electrode. X-ray photoelectron spectrum (XPS) of HDT suggests that it forms a monolayer on Au surface through one of the two single bondSH groups and the other single bondSH group is pointing away from the electrode surface. The free single bondSH groups of HDT were used to covalently attach colloidal AuNPs. The covalent attachment of AuNPs on HDT monolayer was confirmed from the observed characteristic carboxylate ion stretching modes of citrate attached with AuNPs in the infra-red reflection absorption spectrum (IRRAS) in addition to a higher reductive desorption charges obtained for AuNPs immobilized on HDT modified Au (Au/HDT/AuNPs) electrode in 0.1 M KOH when compared to HDT modified Au (Au/HDT) electrode. The electron transfer reaction of [Fe(CN)6]4−/3− was markedly hindered at the HDT modified Au (Au/HDT) electrode while it was restored with a peak separation of 74 mV after the immobilization of AuNPs on Au/HDT (Au/HDT/AuNPs) electrode indicating a good electronic communication between the immobilized AuNPs and the underlying bulk Au electrode through a HDT monolayer. The Cottrell slope obtained from the potential-step chronoamperometric measurements for the reduction of ferricyanide at Au/HDT/AuNPs was higher than that of bare Au electrode indicating the increased effective surface area of AuNPs modified electrode. The Au/HDT/AuNPs electrode exhibits excellent electrocatalytic activity towards the oxidation of ascorbic acid (AA) by enhancing the oxidation peak current to more than two times with a 210 mV negative shift in the oxidation potential when compared to a bare Au electrode. The standard heterogeneous electron transfer rate constant (ks) calculated for AA oxidation at Au/HDT/AuNPs electrode was 5.4 × 10−3 cm s−1. The oxidation peak of AA at Au/HDT/AuNPs electrode was highly stable upon repeated potential cycling. Linear calibration plot was obtained for AA over the concentration range of 1–110 μM with a correlation coefficient of 0.9950. The detection limit of AA was found to be 1 μM. The common physiological interferents such as glucose, oxalate ions and urea do not show any interference within the detection limit of AA. The selectivity of the AuNPs modified electrode was illustrated by the determination of AA in the presence of uric acid.
Resumo:
The aim of this paper is to obtain the momentum transfer coefficient between the two phases, denoted by f and p, occupying a bi-disperse porous medium by mapping the available experimental data to the theoretical model proposed by Nield and Kuznetsov. Data pertinent to plate-fin heat exchangers, as bi-disperse porous media, were used. The measured pressure drops for such heat exchangers are then used to give the overall permeability which is linked to the porosity and permeability of each phase as well as the interfacial momentum transfer coefficient between the two phases. Accordingly, numerical values are obtained for the momentum transfer coefficient for three different fin spacing values considered in the heat exchanger experiments.
Resumo:
BACKGROUND: The evaluation of retinal image quality in cataract eyes has gained importance and the clinical modulation transfer functions (MTF) can obtained by aberrometer and double pass (DP) system. This study aimed to compare MTF derived from a ray tracing aberrometer and a DP system in early cataractous and normal eyes. METHODS: There were 128 subjects with 61 control eyes and 67 eyes with early cataract defined according to the Lens Opacities Classification System III. A laser ray-tracing wavefront aberrometer (iTrace) and a double pass (DP) system (OQAS) assessed ocular MTF for 6.0 mm pupil diameters following dilation. Areas under the MTF (AUMTF) and their correlations were analyzed. Stepwise multiple regression analysis assessed factors affecting the differences between iTrace- and OQAS-derived AUMTF for the early cataract group. RESULTS: For both early cataract and control groups, iTrace-derived MTFs were higher than OQAS-derived MTFs across a range of spatial frequencies (P < 0.01). No significant difference between the two groups occurred for iTrace-derived AUMTF, but the early cataract group had significantly smaller OQAS-derived AUMTF than did the control group (P < 0.01). AUMTF determined from both the techniques demonstrated significant correlations with nuclear opacities, higher-order aberrations (HOAs), visual acuity, and contrast sensitivity functions, while the OQAS-derived AUMTF also demonstrated significant correlations with age and cortical opacity grade. The factors significantly affecting the difference between iTrace and OQAS AUMTF were root-mean-squared HOAs (standardized beta coefficient = -0.63, P < 0.01) and age (standardized beta coefficient = 0.26, P < 0.01). CONCLUSIONS: MTFs determined from a iTrace and a DP system (OQAS) differ significantly in early cataractous and normal subjects. Correlations with visual performance were higher for the DP system. OQAS-derived MTF may be useful as an indicator of visual performance in early cataract eyes.
Resumo:
There has been an increasing focus on the development of test methods to evaluate the durability performance of concrete. This paper contributes to this focus by presenting a study that evaluates the effect of water accessible porosity and oven-dry unit weight on the resistance of both normal and light-weight concrete to chloride-ion penetration. Based on the experimental results and regression analyses, empirical models are established to correlate the total charge passed and the chloride migration coefficient with the basic properties of concrete such as water accessible porosity, oven dry unit weight, and compressive strength. These equations can be broadly applied to both normal and lightweight aggregate concretes. The model was also validated by an independent set of experimental results from two different concrete mixtures. The model provides a very good estimate on the concrete’s durability performance in respect to the resistance to chloride ion penetration.
Resumo:
Objective. This study investigated cognitive functioning among older adults with physical debility not attributable to an acute injury or neurological condition who were receiving subacute inpatient physical rehabilitation. Design. A cohort investigation with assessments at admission and discharge. Setting. Three geriatric rehabilitation hospital wards. Participants. Consecutive rehabilitation admissions () following acute hospitalization (study criteria excluded orthopaedic, neurological, or amputation admissions). Intervention. Usual rehabilitation care. Measurements. The Functional Independence Measure (FIM) Cognitive and Motor items. Results. A total of 704 (86.5%) participants (mean age = 76.5 years) completed both assessments. Significant improvement in FIM Cognitive items (-score range 3.93–8.74, all ) and FIM Cognitive total score (-score = 9.12, ) occurred, in addition to improvement in FIM Motor performance. A moderate positive correlation existed between change in Motor and Cognitive scores (Spearman’s rho = 0.41). Generalized linear modelling indicated that better cognition at admission (coefficient = 0.398, ) and younger age (coefficient = −0.280, ) were predictive of improvement in Motor performance. Younger age (coefficient = −0.049, ) was predictive of improvement in FIM Cognitive score. Conclusions. Improvement in cognitive functioning was observed in addition to motor function improvement among this population. Causal links cannot be drawn without further research.