902 resultados para Mandibular Advancement Device® (MAD-ITO)
Resumo:
The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1 mm of displacement, no statistically significant difference was found. At 2 mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.
Resumo:
It is known that slow breathing (<10 breaths min(-1)) reduces blood pressure ( BP), but the mechanisms involved in this phenomenon are not completely clear. The aim of this study was to evaluate the acute responses of the muscle sympathetic nerve activity, BP and heart rate (HR), using device-guided slow breathing ( breathe with interactive music (BIM)) or calm music. In all, 27 treated mild hypertensives were enrolled. Muscle sympathetic nerve activity, BP and HR were measured for 5min before the use of the device (n=14) or while subjects listened to calm music (n=13), it was measured again for 15 min while in use and finally, 5min after the interventions. BIM device reduced respiratory rate from 16 +/- 3 beats per minute (b.p.m) to 5.5 +/- 1.8 b.p.m (P<0.05), calm music did not affect this variable. Both interventions reduced systolic (-6 and -4mmHg for both) and diastolic BPs (-4mmHg and -3mmHg, respectively) and did not affect the HR (-1 and -2 b.p.m respectively). Only the BIM device reduced the sympathetic nerve activity of the sample (-8bursts min(-1)). In conclusion, both device-guided slow breathing and listening to calm music have decreased BP but only the device-guided slow breathing was able to reduce the peripheral sympathetic nerve activity. Hypertension Research ( 2010) 33, 708-712; doi: 10.1038/hr.2010.74; published online 3 June 2010
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.
Resumo:
Mandibular prognathism typically shows familial aggregation. Various genetic models have been described and it is assumed to be a multifactorial and polygenic trait, with a threshold for expression. Our goal was to examine specific genetic models of the familial transmission of this trait. The study sample comprised of 2,562 individuals from 55 families. Complete family histories for each proband were ascertained and the affection status of relatives were confirmed by lateral cephalograms, photographs, and dental models. Pedigrees were drawn using PELICAN and complex segregation analysis was performed using POINTER. Parts of some pedigrees were excluded to create one founder pedigrees, so the total N was 2,050. Analysis showed more affected females than males (P = 0.030). The majority of the pedigrees suggest autosomal dominant inheritance. Incomplete penetrance was demonstrated by the ratio of affected/unaffected parents and siblings. The heritability of mandibular prognathism was estimated to be 0.316. We conclude that there is a major gene that influences the expression of mandibular prognathism with clear signs of Mendelian inheritance and a multifactorial component. (C) 2007 Wiley-Liss, Inc.
Resumo:
Multilayers of PbTe quantum dots embedded in SiO2 were fabricated by alternate use of Pulsed Laser Deposition (PLD) and Plasma Enhanced Chemical Vapor Deposition (PECVD) techniques. The morphological properties of the nanostructured material were studied by means of High Resolution Transmission Electron Microscopy (HRTEM), Grazing-Incidence Small-Angle X-ray scattering (GISAXS) and X-ray Reflectometry (XRR) techniques. A preliminary analysis of the GISAXS spectra provided information about the multilayer periodicity and its relationship to the size of the deposited PbTe nanoparticles. Finally multilayers were fabricated inside a Fabry-Perot cavity. The device was characterized by means of Scanning Electron Microscopy (SEM). Transmittance measurements show the device functionality in the infrared region. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
We show a simple strategy to obtain all efficient enzymatic broelectrochemical device, in which urease was immobilized oil electroactive nanostructured membranes (ENMs) made with polyaniline and silver nanoparticles (AgNP) stabilized in polyvinyl alcohol (PAni/PVA-AgNP). Fabrication of the modified electrodes comprised the chemical deposition of polyaniline followed by drop-coating of PVA-AgNP and urease, resulting in a final ITO/PAni/PVA-AgNP/urease electrode Configuration. For comparison. the electrochemical performance of ITO/PAni/urease electrodes (without Ag nanoparticles) was also studied. The performance of the modified electrodes toward Urea hydrolysis was investigated via amperometric measurements, revealing a fast increase in cathodic current with a well-defined peak upon addition of urea to the electrolytic solution. The cathodic currents for the ITO/PAni/PVA-AgNP urease electrodes were significantly higher than for the ITO/PAni/urease electrodes. The friendly environment provided by the ITO/PAni/PVA-AgNP electrode to the immobilized enzyme promoted efficient catalytic conversion of urea into ammonium and bicarbonate tons. Using the Michaelis-Menten kinetics equation, a K(M)(aPP) of 2.7 mmol L(-1) was obtained. indicating that the electrode architecture employed may be advantageous for fabrication of enzymatic devices with improved biocatalytic properties. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.
Resumo:
Persistent photoconductivity (PPC) in vanadyl phthalocyanine (VOPc) organic light-emitting diodes was investigated using photoconductive time response, photocurrent-voltage characteristics and charge extraction in linearly increasing voltage (CELIV) measurements. The experiments were performed in phase 1 (amorphous) and in phase 2 (crystalline) samples obtained by the physical vapour deposition (PVD) technique over ITO/glass electrodes with an Al covering electrode. The results indicated a photoconductivity with a long decay time in phase 1 VOPc described by a stretched exponential relaxation. The device showed a rectifying behaviour and the mobility of holes was measured by CELIV, following a dispersive model. In crystalline samples the PPC effect was not observed and the dominant mechanism of transport of holes was hopping in a Gaussian density of states.
Resumo:
In this work we studied the properties of absorption and emission line shape of layer-by-layer (LBL) poly(p-phenylene vinylene) (PPV) on indium-tin oxide (ITO) electrode. To minimize the PPV thermal conversion effects during the polymer processing, we used a less aggressive leaving group in the precursor polymer; minimizing electrode degradation. LBL ITO/PPV films showed the same absorption and emission line shape compared with LBL PPV films deposited on non-metallic substrates (glass). With this analysis we indirectly observe the decrease in the ITO degradation. Atomic force microscopy (AFM) technique was used to analyze quantitatively the microscopic morphology of the film surface. Results indicated that the substrate topology is not affected, to a large extent, by the use of dodecylbenzensulfonate (DBS) ion. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
One method using a solid sampling device for the direct determination of Cr and Ni in fresh and used lubricating oils by graphite furnace atomic absorption spectrometry are proposed. The high organic content in the samples was minimized using a digestion step at 400 degrees C in combination with an oxidant mixture 1.0% (v v(-1)) HNO3+15% (v v(-1)) H2O2+0.1% (m v(-1)) Triton X-100 for the in situ digestion. The 3-field mode Zeeman-effect allowed the spectrometer calibration up to 5 ng of Cr and Ni. The quantification limits were 0.86 mu g g(-1) for Cr and 0.82 mg g(-1) for Ni, respectively. The analysis of reference materials showed no statistically significant difference between the recommended values and those obtained by the proposed methods.
Resumo:
The performance of modular home made capillary electrophoresis equipment with spectrophotometric detection, at a visible region by means of a miniaturized linear charge coupled device, was evaluated for the determination of four food dyes. This system presents a simple but efficient home made cell detection scheme. A computer program that converts the spectral data after each run into the electropherograms was developed to evaluate the analytical parameters. The dyes selected for analytical evaluation of the system were Brilliant Blue FCF, Fast Green FCF, Sunset Yellow FCF, and Amaranth. Separation was carried out in a 29cm length and 75 mu m I.D fused silica capillary, using 10mmolL-1 borate buffer at pH 9, with separation voltage of 7.5kV. The detection limits for the dyes were between 0.3 and 1.5mgL-1 and the method presented adequate linearity over the ranges studied, with correlation coefficients greater than 0.99. The method was applied for determination and quantification of these dyes in fruit juices and candies.
Resumo:
This research is based on consumer complaints with respect to recently purchased consumer electronics. This research document will investigate the instances of development and device management as a tool used to aid consumer and manage consumer’s mobile products in order to resolve issues in or before the consumers is aware one exists. The problem at the present time is that mobile devices are becoming very advanced pieces of technology, and not all manufacturers and network providers have kept up the support element of End users. As such, the subject of the research is to investigate how device management could possibly be used as a method to promote research and development of mobile devices, and provide a better experience for the consumer. The wireless world is becoming increasingly complex as revenue opportunities are driven by new and innovative data services. We can no longer expect the customer to have the knowledge or ability to configure their own device. Device Management platforms can address the challenges of device configuration and support through new enabling technologies. Leveraging these technologies will allow a network operator to reduce the cost of subscriber ownership, drive increased ARPU (Average Revenue per User) by removing barriers to adoption, reduce churn by improving the customer experience and increase customer loyalty. DM technologies provide a flexible and powerful management method but are managing the same device features that have historically been configured manually through call centers or by the end user making changes directly on the device. For this reason DM technologies must be treated as part of a wider support solution. The traditional requirement for discovery, fault finding, troubleshooting and diagnosis are still as relevant with DM as they are in the current human support environment yet the current generation of solutions do little to address this problem. In the deployment of an effective Device Management solution the network operator must consider the integration of the DM platform, interfacing with many areas of the business, supported by knowledge of the relationship between devices, applications, solutions and services maintained on an ongoing basis. Complementing the DM solution with published device information, setup guides, training material and web based tools will ensure the quality of the customer experience, ensuring that problems are completely resolved, driving data usage by focusing customer education on the use of the wireless service In this way device management becomes a tool used both internally within the network or device vendor and by the customer themselves, with each user empowered to effectively manage the device without any prior knowledge or experience, confident that changes they apply will be relevant, accurate, stable and compatible. The value offered by an effective DM solution with an expert knowledge service will become a significant differentiator for the network operator in an ever competitive wireless market. This research document is intended to highlight some of the issues the industry faces as device management technologies become more prevalent, and offers some potential solutions to simplify the increasingly complex task of managing devices on the network, where device management can be used as a tool to aid customer relations and manage customer’s mobile products in order to resolve issues before the user is aware one exists. The research is broken down into the following, Customer Relationship Management, Device management, the role of knowledge with the DM, Companies that have successfully implemented device management, and the future of device management and CRM. And it also consists of questionnaires aimed at technical support agents and mobile device users. Interview was carried out with CRM managers within support centre to further the evidence gathered. To conclude, the document is to consider the advantages and disadvantages of device management and attempt to determine the influence it will have over customer support centre, and what methods could be used to implement it.
Resumo:
Background: A test battery consisting of self-assessments and motor tests (tapping and spiral drawing) was developed for a hand computer with touch screen in a telemedicine setting. Objectives: To develop and evaluate a web-based system that delivers decision support information to the treating clinical staff for assessing PD symptoms in their patients based on the test battery data. Methods: The test battery is currently being used in a clinical trial (DAPHNE, EudraCT No. 2005-002654-21) by sixty five patients with advanced Parkinson’s disease (PD) on 9991 test occasions (four tests per day during in all 362 week-long test periods) at nine clinics around Sweden. Test results are sent continuously from the hand unit over a mobile net to a central computer and processed with statistical methods. They are summarized into scores for different dimensions of the symptom state and an ‘overall test score’ reflecting the overall condition of the patient during a test period. The information in the web application is organized and presented graphically in a way that the general overview of the patient performance per test period is emphasized. Focus is on the overall test score, symptom dimensions and daily summaries. In a recent preliminary user evaluation, the web application was demonstrated to the fifteen study nurses who had used the test battery in the clinical trial. At least one patient per clinic was shown. Results: In general, the responses from nurses were positive. They claimed that the test results shown in the system were consistent with their own clinical observations. They could follow complications, changes and trends within their patients. Discussion: In conclusion, the system is able to summarise the various time series of motor test results and self-assessments during test periods and present them in a useful manner. Its main contribution is a novel and reliable way to capture and easily access symptom information from patients’ home environment. The convenient access to current symptom profile as well as symptom history provides a basis for individualized evaluation and adjustment of treatments.