979 resultados para METABOLIC END-PRODUCTS
Resumo:
Background: The aim was to evaluate the presence of metabolic bone disease (MBD) in patients with Crohn’s disease (CD) and to identify potential etiologic factors. Methods: The case–control study included 99 patients with CD and 56 controls with a similar age and gender distribution. Both groups had dual-energy x-ray absorptionmetry and a nutritional evaluation. Single nucleotide polymorphisms at the IL1, TNF-a, LTa, and IL-6 genes were analyzed in patients only. Statistical analysis was performed using SPSS software. Results: The prevalence of MBD was significantly higher in patients (P ¼ 0.006). CD patients with osteoporosis were older (P < 0.005), small bowel involvement and surgical resections were more frequent (P < 0.005), they more often exhibited a penetrating or stricturing phenotype (P < 0.05), duration of disease over 15 years (P < 0.005), and body mass index (BMI) under 18.5 kg/m2 (P < 0.01) were more often found. No association was found with steroid use. Patients with a Z-score < 2.0 more frequently had chronic active disease (P < 0.05). With regard to diet, low vitamin K intake was more frequent (P ¼ 0.03) and intake of total, monounsaturated, and polyunsaturated fat was higher in patients with Z-score < 2.0 (P < 0.05). With respect to genetics, carriage of the polymorphic allele for LTa252 A/G was associated with a higher risk of osteoporosis (P ¼ 0.02). Regression analysis showed that age over 40 years, chronic active disease, and previous colonic resections were independently associated with the risk of developing MBD. Conclusions: The prevalence of MBD was significantly higher in CD patients. Besides the usual risk factors, we observed that factors related to chronic active and long-lasting disease increased the risk of MBD.
Resumo:
Sendo, o exercício físico uma parte importante na Reabilitação de pacientes com patologia cardíaca, o presente estudo tem por Objectivo: verificar se um programa de exercícios aeróbios, mesmo quando associadas a patologias crónicas poderão ter efeito nas variáveis da capacidade funcional, ansiedade e depressão e qualidade de vida. Tipo de estudo: série de estudos de caso prospectivo. Métodos: O programa de exercício realizou-se em 8 semanas tendo cada um dos doentes cardíacos sido avaliados no início do plano e no fim das 8 semanas sobre os seguintes aspectos: a composição corporal (massa magra, massa gorda, Taxa metabólica basal e água), o teste dos 6 minutos de marcha, em termos de ansiedade /depressão e percepção do estados de saúde. Resultados: Em relação à composição corporal, destacase a perda de peso no caso clínico 4 com uma variação de -4.54%; aumento de massa magra de 46.6% e uma diminuição de massa gorda de -41 .1% no caso clínico 2 e um aumento de 4,78% da taxa de metabolismo basal no caso clínico 1 . Na capacidade funcional de exercício houve uma variação média positiva de 16,8% na distância percorrida; verifica-se também um aumento gradual de tempo de exercício ao longo das 8 semanas de tratamento. Por último, uma variação média negativa nos níveis de ansiedade de -28,5% e depressão de -40%; um aumento de 30% na percepção subjectiva do estado de saúde nos 4 casos clínicos deste estudo. Conclusão: O programa de exercícios teve efeitos positivos nos 4 casos clínicos estudados. No entanto, pelas características individuais de cada caso, os seus efeitos tiveram impacto diferente em cada caso, devendo por isso, ser prescrito exercício de forma individualizada.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Dissertação de Mestrado em Ambiente, Saúde e Segurança.
Resumo:
contribuindo para o aumento da gordura abdominal, e consequentes complicações metabólicas. O exercício físico permite quebrar este ciclo através da estimulação da lipólise e da utilização de ácidos gordos. Objetivo: Verificar os efeitos de um programa de exercícios no domicílio, em indivíduos com doença arterial coronária, na composição corporal, gordura abdominal, perfil lipídico, glicose, e nível de atividade física. Métodos: Estudo experimental composto por 20 indivíduos, aleatorizados grupo experimental (GE) e grupo de controlo (GC), ambos com 10, tendo o GE sido sujeito ao programa durante 8 semanas. Realizou-se uma avaliação inicial e final, através da bioimpedância, Tomografia Computorizada (TC) abdominal, perimetria, adipometria, análises sanguíneas e acelerómetro. Resultados: Numa análise intergrupal, verificouse uma diminuição da percentagem (%) de gordura total (GT) calculado pela adipometria (p<0.01), na prega supra-ilíaca (p=0.005), na prega abdominal horizontal (p=0.001) e vertical (p=0.003) no GE, e da % de tempo em atividades moderadas no GC (p=0.035). Após 8 semanas o GE diminuiu a %GT (p=0.008); a massa gorda (MG) (p=0.002); perímetro abaixo da última costela (p=0.037) e acima das cristas-ilíacas (p=0.021); %GT calculado (p=0.002); pregas supra-ilíaca (p=0.008), abdominal horizontal (p=0.002) e vertical (p=0.033); TC abdominal subcutâneo (p=0.031) e %de tempo em atividades vigorosas (p=0.031). O GC diminuiu a %GT (p=0.002) e MG (p=0.008); aumentou o perímetro ao nível dos grandes trocânteres (p=0.008), diminuiu o rácio cintura/anca (p=0.002), e a %de tempo em atividades moderadas (p=0.031) e vigorosas (p=0.008). Parece existir uma tendência no GE para diminuição do rácio cintura/anca, c-LDL, triglicerídeos e aumento do nível de atividade moderado. Conclusão: O programa de exercícios no domicílio demonstrou uma diminuição da gordura abdominal, alteração da composição corporal, e parece promover uma melhoria no perfil lipídico e no aumento do nível de atividade física moderado.
Resumo:
Tendo em conta a contaminação normal de compostos azotados existente na água de uma piscina, derivados na sua maioria do próprio banhista, é inevitável a formação de subprodutos, quando estes reagem com o cloro como desinfectante. De todos os subprodutos de desinfecção que se formam, as cloraminas, incluídas no controlo químico da água de piscina no parâmetro cloro combinado, são as mais conhecidas. Estes compostos são responsáveis por irritações oculares, das mucosas e do trato respiratório. São estes os compostos responsáveis pelo comummente designado ‘cheiro a cloro’ característico de muitas piscinas. Para além destes efeitos nefastos da sua presença na água, estes compostos possuem um poder desinfectante muito menor ao do ácido hipocloroso, a forma activa do cloro com maior capacidade desinfectante. Por todas estas razões, uma piscina com uma concentração de cloro combinado elevada não é adequada para uso. Com a premissa comprovada em diversos estudos do uso de zeólitos para diminuição de compostos amoniacais por adsorção, é objectivo deste estudo comprovar a sua viabilidade no uso da redução destes compostos nas águas de piscinas. Para tal, foram realizados estudos em contínuo, numa piscina piloto onde foram aplicados hipoclorito de sódio e amoníaco, e ensaios em descontínuo, para que fosse determinada a capacidade e o tempo necessário ao equilíbrio de adsorção para este par adsorvente/adsorvato. Nos ensaios em contínuo, a clinoptilolite adsorveu 1,652 g Cl2/kg de clinoptilolite, em aproximadamente 300 horas de funcionamento, a 23,5 ºC. Nos ensaios em descontínuo, foram estudadas diferentes concentrações iniciais de cloro combinado. Os ensaios foram realizados a 20 ºC. Para uma concentração inicial de 4,06 mg/L Cl2, obteve-se uma capacidade de adsorção de 0,28 g Cl2/kg de clinoptilolite, ao fim de 360 horas. Para uma concentração inicial de 2 mg / L Cl2, o ensaio teve uma duração de 360 horas, e não se verificou estabilização. No entanto, findo este tempo, ocorreu a adsorção de 0,28 g Cl2/kg de clinoptilolite. Para uma concentração inicial de 0,56 mg/L Cl2, obteve-se um valor inferior, de 0,027 g Cl2/kg de clinoptilolite ao fim de 168 horas.
Resumo:
Este trabalho, numa fase inicial, teve como pilar fundamental, a optimização energética de uma indústria de curtumes, mais concretamente da empresa Dias Ruivo. Pretendia-se avaliar todos os gastos de energia apresentados pela empresa, com o intuito de verificar se haveria possibilidade de diminuir a factura da electricidade e os custos associados, mantendo a qualidade dos produtos finais. Ainda se pretendia averiguar a viabilidade de reutilização de alguns desperdícios permitindo diminuir a quantidade de energia necessária para o aquecimento de algumas correntes de água. Por último, após os dados recolhidos, sugeriram-se medidas de melhoria, que possibilitariam que a empresa utilizasse os seus recursos de forma optimizada, não apresentando assim gastos desnecessários. Começando pela análise da factura de electricidade, verificou-se que nos anos de 2010 e 2011, a empresa apresentou um consumo de energia de 120 e 128 tep/ano, respectivamente. Determinaram-se igualmente os respectivos indicadores constatando-se que o valor médio para a intensidade carbónica foi de 900 e 1148 kg CO2/tep e para o consumo específico obteve-se 0,131 e 0,152 kgep/ft2, respectivamente. Numa segunda fase, tendo em conta a constante aposta da empresa na inovação de artigos em couro e o facto de estar envolvida num projecto mobilizador de ciência e tecnologia com esse fim, o trabalho incidiu no desenvolvimento de um produto inovador designado por floater que deve ser macio e mais leve que os produtos normais. Com base na aplicação de proteases apropriadas, desenvolveu-se um produto que, ainda na fase de ensaios de bancada e piloto, satisfaz no que respeita à macieza e leveza, sendo que se conseguiu um valor de 67 g/ft2 contra um valor de 75g/ft2 do padrão.
Resumo:
Dissertação de Mestrado, Tecnologia e Segurança Alimentar, 13 de Julho de 2015, Universidade dos Açores.
Resumo:
OBJECTIVE: To evaluate metabolic changes associated with highly active antiretroviral therapy (HAART) in HIV-positive patients, and to identify risk factors associated. METHODS: Retrospective study that included 110 HIV-positive patients who where on HAART in the city of Porto Alegre (Southern Brazil) between January 2003 and March 2004. Data on demographic variables, cigarette smoking, diabetes mellitus, cholesterol and triglyceride levels, stage of HIV infection, antiretroviral therapy and HCV coinfection were collected. General linear models procedure for repeated measures was used to test the interaction between HAART and HCV coinfection or protease inhibitor treatment. RESULTS: Total cholesterol, triglycerides, and glucose levels significantly increased after receiving HAART (p<0.001 for all variables), but no interaction with protease inhibitors was seen for total cholesterol, glucose and triglyceride levels (interaction treatment*protease inhibitors p=0.741, p=0.784, and p=0.081, respectively). An association between total cholesterol levels and HCV coinfection was found both at baseline and follow-up (effect of HCV coinfection, p=0.011). Glucose levels were increased by HAART (treatment effect, p=0.036), but the effect was associated to HCV coinfection (treatment*HCV effect, p=0.018). Gender, smoking habit, intravenous drug use and age were not significantly associated with cholesterol, triglyceride and glucose changes. CONCLUSIONS: HCV-infected patients at baseline were significantly less likely to develop hypercholesterolemia. The results provide further evidence of the role of HAART for the development of metabolic disturbances.
Resumo:
II European Conference on Curriculum Studies. "Curriculum studies: Policies, perspectives and practices”. Porto, FPCEUP, October 16th - 17th.
Resumo:
Este trabalho teve o intuito de criar uma linha de montagem universal através da qual será dada formação aos atuais operadores e a novos que possam vir a pertencer ao departamento de montagem na empresa Grohe Portugal. Para tal era necessário saber realizar um estudo de métodos e um estudo de tempos sobre os vários processos existentes no departamento de montagem. Com esse intuito foi elaborada uma pesquisa sobre as referidas temáticas, onde ficou evidente a sua importância e a sua imprescindibilidade. Inicialmente houve também um acompanhamento das montagens dos produtos nas várias linhas, de forma a adquirir conhecimento sobre as características dos processos de montagem existentes no departamento. Os pontos mais importantes durante o estudo de métodos e tempos realizado foram a definição de toda a estrutura do processo, das ferramentas e materiais a utilizar, não esquecendo a relação entre o operador e as suas ferramentas e a medição de tempos de todas as tarefas necessárias para cada processo de montagem. A linha de montagem, cujo projeto se desenvolveu, é composta por três bancadas e consiste num conjunto de postos de trabalho onde são executadas as operações através de máquinas, do trabalho humano, ou da sua conjugação, dispostos numa determinada sequência, sendo alguns deles amovíveis. Para a realização e conclusão deste projeto foram superadas diversas etapas, sendo que as mais relevantes foram: a análise dos processos de montagem; estudo de tempos de todas as famílias de produtos a serem implementados na linha de formação; - Definição da estrutura da linha de montagem; - Definição das rampas e dos tubos de abastecimento da linha; - Desenho da linha de montagem em 3D no software SolidWorks. Paralelamente foram também desenvolvidos estudos de tempos sobre alguns produtos com o intuito de serem implementadas melhorias, ou apenas para o controlo de tempos necessários para a realização das operações Por último, foi também elaborada uma recolha de ferramentas existentes no departamento de montagem para serem elaborados manuais de instruções das ferramentas fabricadas internamente, com o objetivo de obter a certificação OSHAS 180001 e de criar documentos com a listagem de materiais necessários para cada produto.
Resumo:
Esta dissertação de Mestrado pretende, numa primeira fase, identificar as condições gerais e os pressupostos da aplicação da ferramenta Análise do Valor (AV) e integrá-la nos Sistemas de Gestão da Qualidade. Pretende-se demonstrar a técnica e aumentar o seu conhecimento, assim como as várias abordagens do processo, as vantagens e os constrangimentos no seu uso, conduzir à ideia que poderá ser útil proceder a uma análise organizada e sistemática dos produtos/serviços existentes nas organizações, abrindo a hipótese a novas soluções para o produto/serviço de mais fácil produção/realização e ensaio ao menor custo. É realçada a importância do conceito da Análise do Valor demonstrando que se pode tornar numa ferramenta eficaz na melhoria dos produtos mas também de processos de fabrico e até em processos administrativos. Sendo a Qualidade entendida como um conjunto de características que um bem, produto ou serviço possui que o tornam apto para satisfazer na plenitude uma dada necessidade do seu utilizador, este trabalho também faz a ligação com os Sistemas de Gestão da Qualidade comparando dois referenciais, a Norma NP EN 12973 e a ISO 9001:2008. Numa segunda fase é realizada uma profunda abordagem à ferramenta QFD – Quality Function Deployment – como uma técnica complementar à aplicação prática da técnica AV e é realizado um estudo a um serviço pós-venda que inclui muitos dos seus conceitos e princípios. O trabalho foi realizado na empresa onde sou colaborador há cerca de 10 anos exercendo o cargo de “Service Manager Press/Post Press” ao departamento de serviço técnico e apoio ao cliente. Foi muito útil a demonstração prática para entendimento das dificuldades sentidas e dos obstáculos a ultrapassar. O trabalho termina com as conclusões do caso prático e as conclusões gerais, mencionando as definições dos aceleradores / obstáculos da aplicação da AV.
Resumo:
The impact of mycotoxins on human and animal health is well recognized. Aflatoxin B1 (AFB1) is by far the most prevalent and the most potent natural carcinogen and is usually the major aflatoxin produced by toxigenic fungal strains. Data available, points to an increasing frequency of poultry feed contamination by aflatoxins. Since aflatoxin residues may accumulate in body tissues, this represents a high risk to human health. Samples from commercial poultry birds have already presented detectable levels of aflatoxin in liver. A descriptive study was developed in order to assess fungal contamination by species from Aspergillus flavus complex in seven Portuguese poultry units. Air fungal contamination was studied by conventional and molecular methods. Air, litter and surfaces samples were collected. To apply molecular methods, air samples of 300L were collected using the Coriolis μ air sampler (Bertin Technologies), at 300 L/min airflow rate. For conventional methodologies, all the collected samples were incubated at 27ºC for five to seven days. Through conventional methods, Aspergillus flavus was the third fungal species (7%) most frequently found in 27 indoor air samples analysed and the most commonly isolated species (75%) in air samples containing only the Aspergillus genus...
Resumo:
The electrochemical behavior of the hydrolysis products of oxadiazon was studied by cyclic and square-wave voltammetry using a glassy carbon electrode. Maximum currents were obtained at pH 12.8 in an aqueous electrolyte solution containing 30% ethanol and the current did not decrease with time showing that there was little adsorption of the reaction products on the electrode surface. The hydrolysis products of oxadiazon were identi®ed, after isolation and puri®cation, as 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl)-2-ethoxycarbonylhydrazine (Oxa1) and 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl) hydrazine (Oxa2) with redox potentials 0.6Vand 70.1V (vs. Ag=AgCl), respectively. Based on the electrochemical behavior of 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl) hydrazine (Oxa2) a simple electroanalytical procedure was developed for the determination of oxadiazon in commercial products used in the treatment of rice crops in Portugal that contain oxadiazon as the active ingredient. The detection limit was 161074 M, the mean content and relative standard deviation obtained for seven samples of two different commercial products by the electrochemical method were 28.4 0.8% (Ronstar) and 1.9 0.2% (Ronstar GR), and the recoveries were 100.3 5.4% and 101.1 5.3 %, respectively.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.