974 resultados para LIQUID GRAPHITE INTERFACE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, accurate and simple method using HPLC-MS/MS was developed and validated for levodopa quantitation in human plasma. Analysis was achieved on a pursuit® C18 analytical column (5 µm; 150 x 4.6 mm i.d.) using a mobile phase (methanol and water , 90:10, v/v) containing formic acid 0.5% v/v, after extracting the samples using a simple protein plasma precipitation with perchloric acid. The developed method was validated in accordance with ANVISA guidelines and was successfully applied to a bioequivalence study in 60 healthy volunteers demonstrating the feasibility and reliability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the treatment of a liquid radioactive waste containing uranium (235U + 238U) using nanofiltration membranes. The membranes were immersed in the waste for 24-5000 h, and their transport properties were evaluated before and after the immersion. Surface of the membranes changed after immersion in the waste. The SW5000 h specimen lost its coating layer of polyvinyl alcohol, and its rejection of sulfate ions and uranium decreased by about 35% and 30%, respectively. After immersion in the waste, the polyamide selective layer of the membranes became less thermally stable than that before immersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening of biomass of a new marine-derived strain of Penicillium roqueforti, as produced by liquid-state fermentation, led to the identification of several volatile organic compounds active in the fatty acid pathway as well as fragments produced by their catabolism, terpenoids, and metabolites from the shikimic acid pathway. In addition, five non-volatile organic compounds, triolein, ergosterol peroxide, 9(11)-dehydroergosterol peroxide, 4-hydroxybenzaldehyde, and d-mannitol, were isolated and identified by spectroscopy. The results showed that this fungal strain did not produce any mycotoxin in the culture conditions applied, and thus is useful for industrial applications, where high value-added biomolecules are generated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activated carbon was produced from the water hyacinth (CAA) by impregnation with ZnCl2 (1:2), followed by pyrolysis at 700 ºC, under N2. CAA was used for the adsorption of phenol, m-cresol and o-cresol from aqueous solutions, using batch adsorption. The effects of contact time, pH, temperature and concentration on sorption were investigated. Adsorption capacity, calculated using the Langmuir model proved to be dependent on temperature, reaching values of 163.7, 130.2 and 142.3 mg g-1 for phenol, m-cresol and o-cresol, respectively, at 45 ºC. Thermodynamic data at the solid-liquid interface suggests an endothermic, spontaneous and environmentally-friendly process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We developed and applied an educational instrument (ID) to discuss, in the discipline of Supervised Pre Service Teachers Practice 1, guidelines for teacher education to redefine teacher knowledge with a specific focus on chemistry teachers. The study used methodological fundamentals of Discursive Textual Analysis that involves identifying and isolating a set of materials subjected to analysis, categorizing these statements and producing texts, integrating these descriptions and interpretations, basing its construction on the category system built. Data were collected through participant observation and text readings used by the students in performing the activity. It was noted that the chemistry teachers trained were able to express opinions that indicated the Construction of Meanings Interface that was the category of analysis established a priori.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride), volume of dispersant (ethanol), volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD) were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spatiotemporal pattern formation in reaction-transport systems takes place spontaneously when the system is kept far from thermodynamic equilibrium. Targets, reaction fronts, waves, spirals, spots and stripes are some typical examples of selforganized structuring. In electrochemical systems, monitoring spatiotemporal patterns of potential in the solid/liquid interface can be done by the use of equally distributed microprobes located close to the working electrode. However, the physical size of each probe can limit the spatial resolution and alter mass transport properties. In contrast, the direct measurement of discrete electrodes does not suffer from this limitation and allows the accurate manipulation of the spatial coupling through changes in resistors connected to the electric circuit. In this paper, the development of an electrochemical setup for multichannel data acquisition with spatiotemporal resolution is described, especially to monitor low levels of currents usually observed in the electro-oxidation of small organic molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilex paraguariensis (yerba-mate) is used as a beverage, and its extract requires adequate quality control methods in order to guarantee quality and safe use. Strategies to develop and optimize a chromatographic method to quantify theobromine, caffeine, and chlorogenic acid in I. paraguariensis extracts were evaluated by applying a quality by design (QbD) model and ultra high-performance liquid chromatography (UHPLC). The presence of these three phytochemical markers in the extracts was evaluated using UHPLC-MS and was confirmed by the chromatographic bands in the total ion current traces (m/z of 181.1 [M+H]+, 195.0 [M+H]+, and 353.0 [M−H]−, respectively). The developed method was then transferred to a high-performance liquid chromatography (HPLC) platform, and the three phytochemical markers were used as external standards in the validation of a method for analyses of these compounds in extracts using a diode array detector (DAD). The validated method was applied to quantify the chlorogenic acid, caffeine, and theobromine in the samples. HPLC-DAD chromatographic fingerprinting was also used in a multivariate approach to process the entire data and to separate the I. paraguariensis extracts into two groups. The developed method is very useful for qualifying and quantifying I. paraguariensis extracts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was used for the preconcentration and determination of thorium in the water samples. In this method, acetone and 1-undecanol were used as disperser and extraction solvents, respectively, and the ligand 1-(2-thenoyl)-3,3,3-trifluoracetone reagent (TTA) and Aliquat 336 was used as a chelating agent and an ion-paring reagent, for the extraction of thorium, respectively. Inductively coupled plasma-optical emission spectrometry was applied for the quantitation of the analyte after preconcentration. The effect of various factors, such as the extraction and disperser solvent, sample pH, concentration of TTA and concentration of aliquat336 were investigated. Under the optimum conditions, the calibration graph was linear within the thorium content range of 1.0-250 µg L-1 with a detection limit of 0.2 µg L-1. The method was also successfully applied for the determination of thorium in the different water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This diploma thesis has been done to international organization which takes care from the accounting actions of two major companies. In this organization are used three different purchasing tools which are used when new asset master data is wanted to input to SAP R/3- system. The aim of this thesis is to find out how much changing the user interface of one of these three e-procurement programs will affect to overall efficiency in asset accounting. As an addition will be introduced project framework which can be used in future projects and which help to avoid certain steps in the development process. At the moment data needs to be inputted manually with many useless mouse clicks and data needs to be searched from many various resources which slow down the process. Other organization has better tools at the moment than the myOrders system which is under investigation Research was started by exploring the main improvement areas. After this possible defects were traced. Suggested improvements were thought by exploring literature which has been written from usability design and research. Meanwhile also directional calculations from the benefits of the project were done alongside with the analysis of the possible risks and threats. After this NSN IT approved the changes which they thought was acceptable. The next step was to program them into tool and test them before releasing to production environment. The calculations were made also from implemented improvements and compared them to planned ones From whole project was made a framework which can be utilized also to other similar projects. The complete calculation was not possible because of time schedule of the project. Important observation in the project was that efficiency is not improved not only by changing the GUI but also improving processes without any programming. Feedback from end user should be also listened more in development process. End-user is after all the one who knows the best how the program should look like.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed to find out the suitability of foam as medium in application of thin liquid films. This consists of research over phenomena related to foam physics and behaviour. Solutions and mixtures to be foamed, foaming agents, foam generation and application methods were evaluated. Over the evaluated solutions and mixtures coating paste and CMC did not foam well. Latex and PVA solutions were foamable and the best solution for foam use was starch. PVA and casein can be used as foaming agents, but the best results were achieved with sodium dodecyl sulphate (SDS). SDS works well with starch solutions producing fine and stable foam. Foaming was done with simple mixers where pressurized air was fed to the solution. The foaming works fine when enough shear force is used together with sufficient foaming agent concentration. Foam application with curtain, rod and cylinder methods with a gap between the application device and paper were not usable because of high coating amount. Coating amounts were smallest with the blade method which achieved 0.9 g/m2 starch layer. Although some strength decrease was expected because of the foaming agent, it dit not have significant effect. The targeted coating amount of 0.5 g/m2 was not achieved due to the limitations with the methods. More precise foam application methods are needed. Continuous foam generation and feed to the paper surface with controllable device such as application teeth could improve the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enantiomeric aglycone lignans contained in a mixture were separated from a fraction of the extract of the stems of Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography. An efficient and fast separation can be achieved with methanol-water (30:70, v/v). Their structures were identified as (+)-lyoniresinol 3alpha-O-beta-glucopyranoside and (-)-lyoniresinol 3alpha-O-beta-glucopyranoside, being reported for the first time in Rubiaceae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.