917 resultados para INTRAOPERATIVE ULTRASOUND
Resumo:
This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such as stroke volume, ejection fraction, and cardiac output. By repeating the measurements from a subject after a brief exercise period, an increase in stroke volume and ejection fraction are easily demonstrable, potentially with or without an increase in left ventricular end-diastolic volume (which indicates preload). Thus, factors that affect cardiac performance can readily be discussed. This activity may be performed as a practical demonstration and visualized using an overhead projector or networked computers, concentrating on using the ultrasound images to teach basic physiological principles. This has proved to be highly popular with students, who reported a significant improvement in their understanding of Frank-Starling's law of the heart with ultrasound imaging.
Resumo:
Introduction: Point-of-care ultrasound (POCUS) use in clinical care is growing rapidly, and advocates have recently proposed the integration of ultrasound into undergraduate medical education (UME). The evidentiary basis for this integration has not been evaluated critically or systematically. In this study, we conducted a critical and systematic review framed by the rationales enumerated by advocates of ultrasound in UME in academic publications.
Methods: This research was conducted in two phases. First, the dominant discursive rationales for the integration of ultrasound in UME were identified using techniques from Foucauldian critical discourse analysis (CDA) from an archive of 403 academic publications. We then sought empirical evidence in support of theses rationales, using a critical synthesis methodology also adapted from CDA.
Results: We identified four dominant discursive rationales, with different levels of evidentiary support. Ultrasound was not demonstrated to improve students’ understanding of anatomy. The benefit of ultrasound in teaching physical examination was inconsistent,and rests on minimal evidence. With POCUS, students’ diagnostic accuracy was improved for certain pathologies, but findings were inconsistent for others. Finally, the rationale that ultrasound training in UME will improve quality of patient care was difficult to evaluate.
Discussion: Our analysis has shown that the frequently repeated rationales for the integration of ultrasound in UME are not supported by a sufficient base of empirical research. The repetition of these dominant discursive rationales in academic publications legitimizes them and may preclude further primary research. Since the value of clinical ultrasound use by medical students remains unproven, educators must consider whether the associated financial and temporal costs are justified or whether more research is required.
Resumo:
In recent years, lipofilling has established itself as one of the most effective and least invasive techniques to treat connective dystrophy subsequent to radiotherapy. We report the case of a patient diagnosed with intraductal carcinoma of the right breast in 1996, at the age of 41. The patient underwent quadrantectomy with ipsilateral axillary lymph node dissection and adjuvant chemotherapy and radiotherapy. Four years later, a recurrence led the patient to undergo a subcutaneous mastectomy and immediate reconstruction, involving the submuscular insertion of a permanent implant. In 2007 the patient suffered both radiodermatitis and capsular contracture around the implant, causing constant pain and significant functional limitation. She first took a leukotriene inhibitor (Zafirlukast, 20 mg daily for 8 months) to reduce the capsular contracture. She then underwent lipofilling (Coleman’s technique) of the area affected by radiodermatitis, in which the skin was considerably thinned and visibly ischemic. A second session followed four months later. Clinical, photographic and ultrasound examination revealed clear and lasting thickening of the superficial tissues, increased coverage of the implant, and reduced skin discoloration and tension.
Resumo:
Introduction Compounds exhibiting antioxidant activity have received much interest in the food industry because of their potential health benefits. Carotenoids such as lycopene, which in the human diet mainly derives from tomatoes (Solanum lycopersicum), have attracted much attention in this aspect and the study of their extraction, processing and storage procedures is of importance. Optical techniques potentially offer advantageous non-invasive and specific methods to monitor them. Objectives To obtain both fluorescence and Raman information to ascertain if ultrasound assisted extraction from tomato pulp has a detrimental effect on lycopene. Method Use of time-resolved fluorescence spectroscopy to monitor carotenoids in a hexane extract obtained from tomato pulp with application of ultrasound treatment (583 kHz). The resultant spectra were a combination of scattering and fluorescence. Because of their different timescales, decay associated spectra could be used to separate fluorescence and Raman information. This simultaneous acquisition of two complementary techniques was coupled with a very high time-resolution fluorescence lifetime measurement of the lycopene. Results Spectroscopic data showed the presence of phytofluene and chlorophyll in addition to lycopene in the tomato extract. The time-resolved spectral measurement containing both fluorescence and Raman data, coupled with high resolution time-resolved measurements, where a lifetime of ~5 ps was attributed to lycopene, indicated lycopene appeared unaltered by ultrasound treatment. Detrimental changes were, however, observed in both chlorophyll and phytofluene contributions. Conclusion Extracted lycopene appeared unaffected by ultrasound treatment, while other constituents (chlorophyll and phytofluene) were degraded.
Resumo:
The pre-operative size of breast tumour is the most important factor in determining feasibility of breast conserving surgery in operable breast cancer. Currently there is no consensus on the most accurate modality to measure tumour size. A prospective study of consecutive and unselected symptomatic patients with invasive breast cancer who had primary surgery between January 2006 and December 2007 was conducted. Patients with multi-focal and multi-centric tumours were excluded. The aim of this study was to find the correlation between histological size of invasive breast cancer and pre-operative tumour size as measured by ultrasound. Over this two year period, data for 192 patients was analysed for this study. The mean tumour diameter on ultrasound and histology was 19.5mm and 29mm respectively. The difference between the means in the two modalities was found to be statistically significant (P<0.001).Ultrasound underestimates the true size of breast tumours as determined histologically. Inaccurate tumour size measurements may result in re-operations to achieve adequate margins.
Resumo:
The application of ultrasound to a solution can induce cavitional phenomena and generate high localised temperatures and pressures. These are dependent of the frequency used and have enabled ultrasound application in areas such as synthetic, green and food chemistry. High frequency (100 kHz to 1 MHz) in particular is promising in food chemistry as a means to inactivate enzymes, replacing the need to use periods of high temperature. A plant enzyme, horseradish peroxidase, was studied using time-resolved fluorescence techniques as a means to assess the effect of high frequency (378 kHz and 583 kHz) ultrasound treatment at equivalent acoustic powers. This uncovered the fluorescence emission from a newly formed species, attributed to the formation of di-tyrosine within the horseradish peroxidase structure caused by auto-oxidation, and linked to enzyme inactivation.
Resumo:
Background and objectives Central venous catheterization of the internal jugular vein is a commonly performed invasive procedure associated with a significant morbidity and even mortality. Ultrasound-guided methods have shown to significantly improve the success of the technique and are recommended by various scientific societies, including the American Society of Anesthesiologists. The aim of this report is to describe an innovative ultrasound-guided central line placement of the internal jugular vein. Technique The authors describe an innovative ultrasound-guided central line placement of the internal jugular vein based on an oblique approach – the “Syringe-Free” approach. This technique allows immediate progression of the guide wire in the venous lumen, while maintaining a real-time continuous ultrasound image. Conclusions The described method adds to the traditional oblique technique the possibility of achieving a continuous real-time ultrasound-guided venipuncture and a guide wire insertion that does not need removing the probe from the puncture field, while having a single operator performing the whole procedure.
Resumo:
BACKGROUND: in 21st century, endoscopic study of the small intestine has undergone a revolution with capsule endoscopy and balloon-assisted enteroscopy. The difficulties and morbidity associated with intraoperative enteroscopy, the gold-standard in the 20th century, made this technique to be relegated to a second level. AIMS: evaluate the actual role and assess the diagnostic and therapeutic value of intraoperative enteroscopy in patients with obscure gastrointestinal bleeding. PATIENTS AND METHODS: we conducted a retrospective study of 19 patients (11 males; mean age: 66.5 ± 15.3 years) submitted to 21 IOE procedures for obscure GI bleeding. Capsule endoscopy and double balloon enteroscopy had been performed in 10 and 5 patients, respectively. RESULTS: with intraoperative enteroscopy a small bowel bleeding lesion was identified in 79% of patients and a gastrointestinal bleeding lesion in 94%. Small bowel findings included: angiodysplasia (n = 6), ulcers (n = 4), small bowel Dieulafoy´s lesion (n = 2), bleeding from anastomotic vessels (n = 1), multiple cavernous hemangiomas (n = 1) and bleeding ectopic jejunal varices (n = 1). Agreement between capsule endoscopy and intraoperative enteroscopy was 70%. Endoscopic and/or surgical treatment was used in 77.8% of the patients with a positive finding on intraoperative enteroscopy, with a rebleeding rate of 21.4% in a mean 21-month follow-up period. Procedure-related mortality and postoperative complications have been 5 and 21%, respectively. CONCLUSIONS: intraoperative enteroscopy remains a valuable tool in selected patients with obscure GI bleeding, achieving a high diagnostic yield and allowing an endoscopic and/or surgical treatment in most of them. However, as an invasive procedure with relevant mortality and morbidity, a precise indication for its use is indispensable.
Resumo:
Advanced oxidation processes (AOPs) are modern methods using reactive hydroxyl radicals for the mineralization of organic pollutants into simple inorganic compounds, such as CO2 and H2O. Among AOPs electrochemical oxidation (EO) is a method suitable for coloured and turbid wastewaters. The degradation of pollutants occurs on electrocatalytic electrodes. The majority of electrodes contain in their structure either expensive materials (diamond and Pt-group metals) or are toxic for the environment compounds (Sb or Pb). One of the main disadvantages of electrochemical method is the polarization and contamination of electrodes due to the deposition of reaction products on their surface, which results in diminishing of the process efficiency. Ultrasound combined with the electrochemical degradation process eliminates electrode contamination because of the continuous mechanical cleaning effect produced by the formation and collapse of acoustic cavitation bubbles near to the electrode surface. Moreover, high frequency ultrasound generates hydroxyl radicals at water sonolysis. Ultrasound-assisted EO is a non-selective method for oxidation of different organic compounds with high degradation efficiencies. The aim of this research was to develop novel sustainable and cost-effective electrodes working as electrocatalysts and test their activity in electrocatalytic oxidation of organic compounds such as dyes and organic acids. Moreover, the goal of the research was to enhance the efficiency of electrocatalytic degradation processes by assisting it with ultrasound in order to eliminate the main drawbacks of a single electrochemical oxidation such as electrodes polarization and passivation. Novel Ti/Ta2O5-SnO2 electrodes were developed and found to be electrocatalytically active towards water (with 5% Ta content, 10 oxide film layers) and organic compounds oxidation (with 7.5% Ta content, 8 oxide film layers) and therefore these electrodes can be applicable in both environmental and energy fields. The synergetic effect of combined electrolysis and sonication was shown while conducting sonoelectrochemical (EO/US) degradation of methylene blue (MB) and formic acid (FA). Complete degradation of MB and FA was achieved after 45 and 120 min of EO/US process respectively in neutral media. Mineralization efficiency of FA over 95% was obtained after 2 h of degradation using high frequency ultrasound (381, 863, 1176 kHz) combined with 9.1 mA/cm2 current density. EO/US degradation of MB provided over 75% mineralization in 8 h. High degradation kinetic rates and mineralization efficiencies of model pollutants obtained in EO/US experiments provide the preconditions for further extrapolation of this treatment method to pilot scale studies with industrial wastewaters.
Resumo:
In Portugal, prenatal care guidelines advocate two prenatal ultrasound scans for all pregnant women. Not following this recommendation is considered inadequate prenatal surveillance. The National Registry of Congenital Anomalies (RENAC in Portuguese) is an active population-based registry and an important instrument for the epidemiological surveillance of congenital anomalies (CA) in Portugal. Regarding pregnancies with CA, this study aims to describe the epidemiology of absent prenatal ultrasound scans and factors associated with this inadequate surveillance.
Resumo:
The aim of this study was to compare two processes for the extraction of R-phycoerythrin (R-PE) from the red seaweed Grateloupia turuturu: ultrasound-assisted extraction (UAE) and ultrasound-assisted enzymatic hydrolysis (UAEH). Process efficiencies were both evaluated by the yield of R-PE extraction and by the level of liquefaction. Experiments were conducted at 40 and 22 °C, for 6 h, using an enzymatic cocktail and an original ultrasonic flow-through reactor. R-PE appeared very sensitive to temperature, thus 22 °C is strongly recommended for its extraction by UAEH or UAE. However, the higher processing temperature (40 °C) clearly increased the extraction of water-soluble compounds (up to 91% of liquefaction). These two new processes are thus promising alternatives for the extraction of water-soluble components including R-PE, from wet seaweeds, with extraction yields at least similar to conventional solid–liquid extraction.