989 resultados para Flat plate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract. Interplanetary scintillation observations of 48 of the 55 Augusto et al. (1998) flat spectrum radio sources were carried out at 111 MHz using the interplanetary scintillation method on the Large Phased Array (LPA) in Russia. Due to the large size of the LPA beam (1◦ × 0.5◦) a careful inspection of all possible confusion sources was made using extant large radio surveys: 37 of the 48 sources are not confused. We were able to estimate the scintillating flux densities of 13 sources, getting upper limits for the remaining 35. Gathering more or improving extant VLBI data on these sources might significantly improve our results. This proof-of-concept project tells us that compact (<1 ) flat spectrum radio sources show strong enough scintillations at 111 MHz to establish/constrain their spectra (low-frequency end). Key words. galaxies: general – galaxies: active – galaxies: quasars: general

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pyrophosphatase activity of rat osseous plate alkaline phosphatase was studied at different concentrations of calcium and magnesium ions. with the aim of characterizing the modulation of enzyme activity by these metals. In the absence of metal ions, the enzyme hydrolysed pyrophosphate following Michaelian kinetics with a specific activity of 36.7 U/mg and K-0.5 = 88 mu M. In the presence of low concentrations (0.1 mM) of magnesium (or calcium) ions, the enzyme also exhibited Michaclian kinetics for the hydrolysis of pyrophosphate, but a significant increase in specific activity (123 U/mg) was observed. K-m values remained almost unchanged. Quite different behavior occurred in the presence of 2 mM magnesium (or calcium) ions. In addition to low-affinity sites (K-0.5 = 40 and 90 mu M, for magnesium and calcium, respectively), high-affinity sites were also observed with K-0.5 values 100-fold lower. The high-affinity sites observed in the presence of calcium ions represented about 10% of those observed for magnesium ions. This was correlated with the fact that only magnesium ions triggered conformational changes yielding a fully active enzyme. These results suggested that the enzyme could hydrolyse pyrophosphate, even at physiological concentrations (4 mu M), since magnesium concentrations are high enough to trigger conformational changes increasing the enzyme activity. A model, suggesting the involvement of magnesium ions in the hydrolysis of pyrophosphate by rat osseous plate alkaline phosphatase is proposed. (C) 1998 Published by Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purified membrane-bound alkaline phosphatase from rat osseous plate hydrolyzed pyrophosphate in the presence of magnesium ions, with a specific activity of 92.7 U/mg. Optimal apparent pH for pyrophosphatase activity was 8.0 and it remained unchanged on increasing the pyrophosphate concentration. In the absence of magnesium ions the enzyme had a K-m = 88 mu M and V = 36.7 U/mg for pyrophosphate and no inhibition by excess substrate was observed. Pyrophosphatase activity was rapidly destroyed at temperatures above 40 degrees C, but magnesium ions apparently protected the enzyme against danaturation. Sodium metavanadate (Ki = 1.0 mM) was a competitive inhibitor of pyrophosphatase activity, while levamisole (Ki = 8.2 mM) and theophylline (Ki = 7.4 mM) were uncompetitive inhibitors. Magnesium ions (K-0.5 = 1.7 mu M) stimulated pyrophosphatase activity, while cobalt (Ki = 48.5 mu M) and zinc (Ki = 22.0 mu M) ions were non-competitive inhibitors. Manganese and calcium ions had no effect on pyrophosphatase activity. The M-w of the pyrophosphatase: protein was 130 kDa by gel filtration, but a value of 65 kDa was obtained by dissociative gel electrophoresis, suggesting that it was a dimer of apparently identical subunits. These results suggested that pyrophosphatase activity stems from the membrane-bound osseous plate alkaline phosphatase and not from a different protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment with phosphatidylinositol-specific phospholipase C of rat osseous plate membranes released up to 90-95% of alkaline phosphatase, but a specific ATPase activity (optimum pH = 7.5) remained bound to the membrane. The hydrolysis of ATP by this ATPase was negligible in the absence of magnesium or calcium ions. However, at millimolar concentrations of magnesium and calcium ions, the membrane-specific ATPase activity increased to about 560-600 U/mg, exhibiting two classes of ATP-hydrolysing sites, and site-site interactions. GTP, UTP, ITP, and CTP were also hydrolyzed by the membrane-specific ATPase. Oligomycin, ouabain, bafilomycin A(1), thapsigargin, omeprazole, ethacrynic acid and EDTA slightly affected membrane-specific ATPase activity while vanadate produced a 18% inhibition. The membrane-specific ATPase activity was insensitive to theophylline, but was inhibited 40% by levamisole. These data suggested that the membrane-specific ATPase activity present in osseous plate membranes, and alkaline phosphatase, were different proteins. (C) 1998 Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are its low cost and easy manufacturing and assembly. The absorbing surface of the collector is formed by an aluminum plate with eight flaps where they lodge PVC pipes. The catchment area of solar radiation corresponds to 1.3 meters. The collector box was made of wood, is covered by transparent glass and thermal insulation of tire chips and expanded polystyrene (EPS). Absorber tubes were connected in parallel through the use of PVC fittings and fixed to the plate by the use of metal poles and rivets. The entire absorber received paint flat black for better absorption of sunlight. The system worked on a thermosiphon assembly and absorber of the collector has been tested in two configurations: with the tubes facing up, directly exposed to the impact of sunlight and facing down, exchanging heat with the plate by conduction. It was determined the most efficient configuration for the correct purpose. The solar collector was connected to a thermal reservoir, also alternative, low-cost forming the system of solar water heating. We evaluated thermal parameters that proved the viability of the heating system studied

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of the present work is related to the dynamics of the steady state, incompressible, laminar flow with heat transfer, of an electrically conducting and Newtonian fluid inside a flat parallel-plate channel under the action of an external and uniform magnetic field. For solution of the governing equations, written in the parabolic boundary layer and stream-function formulation, it was employed the hybrid, numericalanalytical, approach known as Generalized Integral Transform Technique (GITT). The flow is sustained by a pressure gradient and the magnetic field is applied in the direction normal to the flow and is assumed that normal magnetic field is kept uniform, remaining larger than any other fields generated in other directions. In order to evaluate the influence of the applied magnetic field on both entrance regions, thermal and hydrodynamic, for this forced convection problem, as well as for validating purposes of the adopted solution methodology, two kinds of channel entry conditions for the velocity field were used: an uniform and an non-MHD parabolic profile. On the other hand, for the thermal problem only an uniform temperature profile at the channel inlet was employed as boundary condition. Along the channel wall, plates are maintained at constant temperature, either equal to or different from each other. Results for the velocity and temperature fields as well as for the main related potentials are produced and compared, for validation purposes, to results reported on literature as function of the main dimensionless governing parameters as Reynolds and Hartman numbers, for typical situations. Finally, in order to illustrate the consistency of the integral transform method, convergence analyses are also effectuated and presented

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increasing industrialization of the planet caused by globalization, it has become increasingly common to search for highly resistant and durable materials for many diverse branches of activities. Thus, production and demand for materials that meet these requirements have constantly increased with time. In view of this, stainless steel is presented as one of the materials which are suitable applications, due to many features that are interesting for several segments of the industry. Concerns of oil companies over heavy oil reservoirs have grown steadily for the last decades. Rheological properties of these oils impair their transport in conventional flow systems. This problem has created the need to develop technologies to improve flow and transport, reducing operation costs so as to enable oil production in the reservoir. Therefore, surfactant-based chemical systems are proposed to optimize transport conditions, effected by reduction of interfacial tensions, thereby enhancing the flow of oil in ducts and reducing load losses by friction. In order to examine such interactions, a study on the wettability of metallic surfaces has been undertaken, represented by measuring of contact angle of surfactant solutions onto flat plates of 304 stainless steel. Aqueous solutions of KCl, surfactants and mixtures of surfactants, with linear and aromatic hydrocarbon chain and ethoxylation degrees ranging between 20 to 100, have been tested. The wettability was assessed by means of a DSA 100 krüss goniometer. The influence of roughness on the wettability was also investigated by machining and polished the stainless steel plates with sandpapers of references ranging between 100 of 1200. The results showed that sanding and polishing plates result in decrease of wettability. As for the solutions, they have provided better wettability of the stainless steel than the KCl solutions tested. It was also been concluded that surfactant mixtures is an option to be considered, since they promote interactions that generate satisfactory contact angles for a good wettability on the stainless steel plate. Another conclusion refers to the influence of the ethoxylation degree of the nonionic surfactant molecules on wettability. It has been observed that contact angles decrease with decreasing ethoxylation degrees. This leads us to conclude that molecules with higher ethoxylation degree, being more hydrophobic, decrease the interaction of water with the ducts, thereby reducing friction and improving the flow

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teve-se o objetivo de verificar a possível seleção de sementes de milho - arredondadas e achatadas - no processo de semeadura com disco perfurado horizontal, bem como as conseqüências na distribuição longitudinal. Os registros dos dados deram-se pela avaliação visual de duas pessoas, com contador manual, no final da esteira carpetada em movimento de 1,54 m s-1, com 4,60 m de perspectiva para avaliação. Assim, um sensor registrava o número de orifícios do disco horizontal que devia passar pelo tubo condutor, e os espaçamentos falhos e múltiplos eram computados por pessoas diferentes. Os espaçamentos aceitáveis foram obtidos pela subtração dos espaçamentos falhos e múltiplos do total contabilizado. A medição do comprimento e espessura das sementes foi realizada com auxílio de paquímetro. Não houve alterações significativas nas variáveis estudadas, até a passagem de 55 mil orifícios do disco horizontal pelo tubo condutor; portanto, não houve seleção de sementes de milho durante a simulação do processo de semeadura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a boundary element formulation for the analysis of building floor slabs, without beams, in which columns are coupled with the plate. An alternative formulation of boundary element method is presented, which considers three nodal displacements values (w, partial derivativew/partial derivativen and partial derivativew/partial derivatives) for the nodes at the boundary of the plate. In this formulation three boundary equations are written for all nodes at the boundary and in the domain of the plate. As the nodes of the column-plate connections are also represented by three nodal values, all these structural elements can be easily coupled. It is supposed that the cross-sections of the columns remain flat after the deflection and consequently the assumption of linear variation of the stress in the plate-column contact surface is also valid. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010