991 resultados para Fire control (Gunnery)
Resumo:
"Cold & Fire", a song by the Australian band Dear Anonymous, was produced as part of the Indie 100 research intensive project within the Independent Music Project (IMP). The IMP is an ongoing, interdisciplinary research arm within QUT. The song's author is Julia Kourtidis.
Resumo:
This paper tested the effects of the 2005 vehicle emission-control law issued in Japan on the market linkages between the U.S. and Japanese palladium futures markets, To determine these effects, we applied a cointegration test both with and without break points in the time series and found that the market linkages between the two countries changed after the break in October 2005. Our results show that the 2005 long-term regulation of vehicle emissions enacted in Japan influenced the international palladium futures market.
Resumo:
Aerial applications of granular insecticides are preferable because they can effectively penetrate vegetation, there is less drift, and no loss of product due to evaporation. We aimed to 1) assess the field efficacy ofVectoBac G to control Aedes vigilax (Skuse) in saltmarsh pools, 2) develop a stochastic-modeling procedure to monitor application quality, and 3) assess the distribution of VectoBac G after an aerial application. Because ground-based studies with Ae. vigilax immatures found that VectoBac G provided effective control below the recommended label rate of 7 kg/ha, we trialed a nominated aerial rate of 5 kg/ha as a case study. Our distribution pattern modeling method indicated that the variability in the number of VectoBac G particles captured in catch-trays was greater than expected for 5 kg/ha and that the widely accepted contour mapping approach to visualize the deposition pattern provided spurious results and therefore was not statistically appropriate. Based on the results of distribution pattern modeling, we calculated the catch tray size required to analyze the distribution of aerially applied granular formulations. The minimum catch tray size for products with large granules was 4 m2 for Altosid pellets and 2 m2 for VectoBac G. In contrast, the minimum catch-tray size for Altosid XRG, Aquabac G, and Altosand, with smaller granule sizes, was 1 m2. Little gain in precision would be made by increasing the catch-tray size further, when the increased workload and infrastructure is considered. Our improved methods for monitoring the distribution pattern of aerially applied granular insecticides can be adapted for use by both public health and agricultural contractors.
Resumo:
A exhibition of sculptural assemblages that continue my exploration of self-portraiture and the sculptural object. The work specifically extends the formal vocabulary of my studio to incorporate smaller composite arrangements with an emphasis on the sculptural support. Small objects that are either modelled or cast from life are assembled into four tableaux that respond to the object-relations that arise through the production process. The resulting exhibiton thus acts a meditation on the ontology of art practice, conceived as a topology of objects.
Resumo:
Purpose: Young adults regularly experience restricted sleep due to a range of social, educational and vocational commitments. Evidence suggests that extended periods of sleep deprivation negatively impact affective and inhibitory control mechanisms leading to behavioural consequences such as increased emotional reactivity and impulsive behaviour. It is less clear whether acute periods of restricted sleep produce the same behavioural consequences. Methods: Nineteen young adults (m = 8, f = 12) with habitual late bed-time (after 22:30 h) and wake-time (after 06:30 h) completed a range of objective and subjective measures assessing sleepiness (Psychomotor Vigilance Task, Karolinska Sleepiness Scale), inhibitory control (Emotional Go/No-go Task and a Balloon Analog Risk Task) and affect (Positive and Negative Affective Schedule). Testing was counterbalanced across participants, and occurred on two occasions once following restricted sleep and once following habitual sleep one week apart. Results: Compared to habitual sleep, sleep restriction produced significantly slower performance on the Psychomotor Vigilance Task, and higher subjective ratings of sleepiness on the Karolinska Sleepiness Scale. Sleep restriction also caused a significant decrease in positive affect, but no change in negative affect on the Affective Schedule. Inhibitory control efficiency was significantly differentiated, with participants showing an increase in risk taking on the Balloon Analog Risk Task, but there was no evidence of increased reactivity to negative stimuli on the Emotional Go/No-go task. Conclusions: Results suggest that even acute periods of sleep loss may cause deficits in affective experiences and increase impulsive and potentially high risk behaviour in young adults.
Resumo:
Hypsipyla grandella and Hypsipyla robusta are serious pests of species of the subfamily Swietenioideae of the family Meliaceae in virtually every moist tropical region of the world. An international workshop reviewed the ecology and control of Hypsipyla shoot borers of Meliaceae, identified promising control methods, and set priorities for future research. The conclusions of the workshop are presented with specific recommendations for research in aspects of the taxonomy, biology, and ecology of Hypsipyla, and pest management options that use host plant resistance and chemical, biological, and silvicultural control
Resumo:
Published information on the incidence of pathogens in the field and laboratory infections of Hypsipyla spp. with entomopathogens is reviewed. In addition, some preliminary results of field collections from Ghana and Costa Rica are presented. Fungal pathogens from the Deuteromycetes have been isolated from both H. robusta Moore and H. grandella Zeller. Mermithid nematodes, Hexamermis spp., have been frequently isolated from larvae in the field and incidence of infection with these pathogens can reach significant levels. Microsporidia have been found in cadavers of larvae collected in the field but none have been identified so far. A number of pathogens of other Lepidoptera have been shown to be infectious to H. grandella , including Bacillus thuringiensis , Deuteromycete fungi and a nucleopolyhedrovirus (NPV) from Autographa californica . Hypsipyla spp. are difficult targets for microbial control, since the larvae are cryptic, occur at low density and occur sporadically. In addition, there is a low damage threshold, the plant is susceptible for a number of years and the susceptible part of the plant will rapidly outgrow any surface application. Key features of the biology of entomopathogens with relevance to the control of low density and cryptic pests are discussed. In the light of this experience, we discuss strategies to improve the possibilities of microbial control of this pest and suggest areas for research.
Resumo:
Hypsipyla grandella (Zeller) is the most important insect pest of the Meliaceae in the Neotropics. This paper reviews the information on H. grandella parasitoids in Latin America and the Caribbean. Preliminary data on the parasitoid complex in Turrialba, Costa Rica, are presented, where apparent parasitisation of H. grandella during 1995–1996 reached 36%. The lowest level of parasitisation occurred during the dry season. The parasitoid Apanteles sp. (= Hypomicrogaster hypsipylae de Santis?) (Hymenoptera: Braconidae) was the most abundant larval parasitoid with a mean of 22 parasitoids per parasitised larva and a sex ratio of 3:1 females to males. Brachymeria conica Ashmead (Hymenoptera: Chalcididae) was found parasitising pupae, but at low frequency
Resumo:
Synthesis of high quality boron carbide (B4C) powder is achieved by carbothermal reduction of boron oxide (B2O3) from a condensed boric acid (H3BO3) / polyvinyl acetate (PVAc) product. Precursor solutions are prepared via polymerisation of vinyl acetate (VA) in methanol in the presence of dissolved H3BO3. With excess VA monomer being removed during evaporation of the solvent, the polymerisation time is then used to manage availability of carbon for reaction.
Resumo:
A field oriented control (FOC) algorithm is simulated and implemented for use with a permanent magnet synchronous motor (PMSM). Rotor position is sensed using Hall effect switches on the stator because other hardware position sensors attached to the rotor may not be desirable or cost effective for certain applications. This places a limit on the resolution of position sensing – only a few Hall effect switches can be placed. In this simulation, three sensors are used and the position information is obtained at higher resolution by estimating it from the rotor dynamics, as shown in literature previously. This study compares the performance of the method with an incremental encoder using simulations. The FOC algorithm is implemented using Digital Motor Control (DMC) and IQ Texas Instruments libraries from a Simulink toolbox called Embedded Coder, and downloaded into a TI microcontroller (TMS320F28335) known as the Piccolo via Code Composer Studio (CCS).
Learned stochastic mobility prediction for planning with control uncertainty on unstructured terrain
Resumo:
Motion planning for planetary rovers must consider control uncertainty in order to maintain the safety of the platform during navigation. Modelling such control uncertainty is difficult due to the complex interaction between the platform and its environment. In this paper, we propose a motion planning approach whereby the outcome of control actions is learned from experience and represented statistically using a Gaussian process regression model. This mobility prediction model is trained using sample executions of motion primitives on representative terrain, and predicts the future outcome of control actions on similar terrain. Using Gaussian process regression allows us to exploit its inherent measure of prediction uncertainty in planning. We integrate mobility prediction into a Markov decision process framework and use dynamic programming to construct a control policy for navigation to a goal region in a terrain map built using an on-board depth sensor. We consider both rigid terrain, consisting of uneven ground, small rocks, and non-traversable rocks, and also deformable terrain. We introduce two methods for training the mobility prediction model from either proprioceptive or exteroceptive observations, and report results from nearly 300 experimental trials using a planetary rover platform in a Mars-analogue environment. Our results validate the approach and demonstrate the value of planning under uncertainty for safe and reliable navigation.
Resumo:
Current design rules for the member capacities of cold-formed steel columns are based on the same non-dimensional strength curve for both fixed and pinned-ended columns at ambient temperature. This research has investigated the accuracy of using current ambient temperature design rules in Australia/New Zealand (AS/NZS 4600), American (AISI S100) and European (Eurocode 3 Part 1.3) standards in determining the flexural–torsional buckling capacities of cold-formed steel columns at uniform elevated temperatures using appropriately reduced mechanical properties. It was found that these design rules accurately predicted the member capacities of pin ended lipped channel columns undergoing flexural torsional buckling at elevated temperatures. However, for fixed ended columns with warping fixity undergoing flexural–torsional buckling, the current design rules significantly underestimated the column capacities as they disregard the beneficial effect of warping fixity. This paper has therefore recommended the use of improved design rules developed for ambient temperature conditions to predict the axial compression capacities of fixed ended columns subject to flexural–torsional buckling at elevated temperatures within AS/NZS 4600 and AISI S100 design provisions. The accuracy of the proposed fire design rules was verified using finite element analysis and test results of cold-formed lipped channel columns at elevated temperatures except for low strength steel columns with intermediate slenderness whose behaviour was influenced by the increased nonlinearity in the stress–strain curves at elevated temperatures. Further research is required to include these effects within AS/NZS 4600 and AISI S100 design rules. However, Eurocode 3 Part 1.3 design rules can be used for this purpose by using suitable buckling curves as recommended in this paper.
Resumo:
Traditionally, the fire resistance rating of Light gauge steel frame (LSF) wall systems is based on approximate prescriptive methods developed using limited fire tests. These fire tests are conducted using standard fire time-temperature curve given in ISO 834. However, in recent times fire has become a major disaster in buildings due to the increase in fire loads as a result of modern furniture and lightweight construction, which make use of thermoplastics materials, synthetic foams and fabrics. Therefore a detailed research study into the performance of load bearing LSF wall systems under both standard and realistic design fires on one side was undertaken to develop improved fire design rules. This study included both full scale fire tests and numerical studies of eight different LSF wall systems conducted for both the standard fire curve and the recently developed realistic design fire curves. The use of previous fire design rules developed for LSF walls subjected to non-uniform elevated temperature distributions based on AISI design manual and Eurocode 3 Parts 1.2 and 1.3 was investigated first. New simplified fire design rules based on AS/NZS 4600, North American Specification and Eurocode 3 Part 1.3 were then proposed with suitable allowances for the interaction effects of compression and bending actions. The importance of considering thermal bowing, magnified thermal bowing and neutral axis shift in the fire design was also investigated and their effects were included. A spread sheet based design tool was developed based on the new design rules to predict the failure load ratio versus time and temperature curves for varying LSF wall configurations. The accuracy of the proposed design rules was verified using the fire test and finite element analysis results for various wall configurations, steel grades, thicknesses and load ratios under both standard and realistic design fire conditions. A simplified method was also proposed to predict the fire resistance rating of LSF walls based on two sets of equations developed for the load ratio-hot flange temperature and the time-temperature relationships. This paper presents the details of this study on LSF wall systems under fire conditions and the results.
Resumo:
Cold-formed steel members are widely used in load bearing Light gauge steel frame (LSF) wall systems with plasterboard linings on both sides. However, these thin-walled steel sections heat up quickly and lose their strength under fire conditions despite the protection provided by plasterboards. Hence there is a need for simple fire design rules to predict their load capacities and fire resistance ratings. During fire events, the LSF wall studs are subjected to non-uniform temperature distributions that cause thermal bowing, neutral axis shift and magnification effects and thus resulting in a combined axial compression and bending action on the LSF wall studs. In this research a series of full scale fire tests was conducted first to evaluate the performance of LSF wall systems with eight different wall configurations under standard fire conditions. Finite element models of LSF walls were then developed, analysed under transient and steady state conditions, and validated using full scale fire tests. Using the results from fire tests and finite element analyses, a detailed investigation was undertaken into the prediction of axial compression strength and failure times of LSF wall studs in standard fires using the available fire design rules based on Australian, American and European standards. The results from both fire tests and finite element analyses were used to investigate the ability of these fire design rules to include the complex effects of non-uniform temperature distributions and their accuracy in predicting the axial compression strengths of wall studs and the failure times. Suitable modifications were then proposed to the fire design rules. This paper presents the details of this investigation into the accuracy of using currently available fire design rules of LSF walls and the results.