994 resultados para Emission Source
Resumo:
A regional geochemical reconnaissance by bottom stream sediment sampling, has delineated an area of high metal content in the north central sector of the North Creek Watershed. Development of a geochemical model, relating to the relative chemical concentrations derived from the chemical analyses of bottom sediments, suspended sediments, stream waters and well waters collected from the north central sector, was designed to discover the source of the anomaly. Samples of each type of material were analysed by the A.R.L. Direct Reading Multi-element Emission Spectrograph Q.A. 137 for elements: Na, K, Ca, Sr, Si, As, Pb, Zn, Cd, Ni, Ti, Ag, Mo, Be, Fe, AI, Mn, Cu, Cr, P and Y. Anomalous results led to the discovery of a spring, the waters of which carried high concentrations of Zn, Cd, Pb, As, Ni, Ti, Ag, Sr and Si. In addition, the spring waters had high concentrations of Na, Ca, Mg, 504 , alkalinity, N03' and low concentrations of K, Cl and NH3. Increased specific conductivity (up to 2500 ~mho/cm.) was noted in the spring waters as well as increased calculated total dissolved solids (up to 2047 mg/l) and increased ionic strength (up to 0.06). On the other hand, decreases were noted in water temperature (8°C), pH (pH 7.2) and Eh (+.154 volts). Piezometer nests were installed in the anomalous north central sector of the watershed. In accordance with the slope of the piezometric surface from wells cased down to the till/bedrock interface, groundwater flow is directed from the recharge area (northwest of the anomaly) towards the artesian spring via the highly fractured dolostone aquifer of the Upper Eramosa Member. The bedrock aquifer is confined by the overlying Halton till and the underlying Lower Eramosa Member (Vinemount Shale). The oxidation of sphalerite and galena and the dissolution of gypsum, celestite, calcite, and dolomite within the Eramosa Member, contributed its highly, dissolved constituents to the circulating groundwaters, the age of which is greater than 20 years as determined by tritium dating. Groundwater is assumed to flow along the Vinemount Shale and discharge as an artesian spring where the shale unit becomes discontinuous. The anomaly is located on a topographic low where bedrock is close to the surface. Thermodynamic evaluation of the major ion speciation from the anomalous spring and surface waters, showed gypsum to be supersaturated in these spring waters. Downstream from the spring, the loss of carbon dioxide from the spring waters resulted in the supersaturation with respect to calcite, aragonite, magnesite and dolomite. This corresponded with increases in Eh (+.304 volts) and pH (pH 8.5) in the anomalous surface waters. In conclusion, the interaction of groundwaters within the highly, mineralized carbonate source (Eramosa Member) resulted in the characteristic Ca*Mg*HC03*S04 spring water at the anomalous site, which appeared to be the principle effect upon controlling the anomalous surface water chemistry.
Resumo:
Modifications to the commercial hydride generator, manufactured by Spectrametrics, resulted in improved operating procedure and enhancement of the arsenic and germanium signals. Experiments with arsenic(III) and arsenic(V) showed that identical reiults could be produced from both oxidation states. However, since arsenic(V) is reduced more slowly than arsenic(III), peak areas and not peak heights must be measured when the arsine is immediately stripped from the system (approximately 5 seconds reaction). When the reduction is allowed to proceed for 20 seconds before the arsine is stripped, peak heights may be used. For a 200 ng/mL solution, the relative standard deviation is 2.8% for As(III) and 3.8% for As(V). The detection limit for arsenic using the modified system is 0.50 ng/mL. Studies performed on As(V) standards show that the interferences from 1000 mg/L of nickel(II), cobalt(II), iron(III), copper(II), cadmium(II), and zinc(II) can be eliminated with the aid of 5 M Hel and 3% L-cystine. Conditions for the reduction of germanium to the corresponding hydride were investigated. The effect of different concentrations of HCl on the reduction of germanium to the covalent hydride in aqueous media by means of NaBH 4 solutions was assessed. Results show that the best response is accomplished at a pH of 1.7. The use of buffer solutions was similarly characterized. In both cases, results showed that the element is best reduced when the final pH of the solution after reaction is almost neutral. In addition, a more sensitive method, which includes the use of (NH4)2S208' has been developed. A 20% increase in the germanium signal is registered when compared to the signal achieved with Hel alone. Moreover, under these conditions, reduction of germanium could be accomplished, even when the solution's pH is neutral. For a 100 ng/mL germanium standard the rsd is 3%. The detection limit for germanium in 0.05 M Hel medium (pH 1.7) is 0.10 ng/mL and 0.09 ng/mL when ammonium persulphate is used in conjunction with Hel. Interferences from 1000 mg/L of iron(III), copper(II), cobalt(II), nickel(II), cadmium(II), lead(II), mercury(II), aluminum(III), tin(IV), arsenic(III), arsenic(V) and zinc(II) were studied and characterized. In this regard, the use of (NH4)ZS20S and Hel at a pH of 1.7 proved to be a successful mixture in the sbppression of the interferences caused by iron, copper, aluminum, tin, lead, and arsenic. The method was applied to the determination of germanium in cherts and iron ores. In addition, experiments with tin(IV) showed that a 15% increase in the tin signal can be accomplished in the presence of 1 mL of (NH4)2S20S 10% (m/V).
Resumo:
Arsenic, bismuth, germanium, antimony and tin were simultaneously determined by continuous hydride generation and inductively coupled plasma-atomic emission spectrometry . I Hydrides were introduced into four different types of gas-liquid separators. Two of the gas-liquid separators were available in-house. A third was developed for this project and a fourth was based on a design used by CET AC. The best signal intensity was achieved by the type II frit-based gas-liquid separator, but the modified Cetac design gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained between experimental values and certified values for arsenic, bismuth, antimony and tin. The method was developed to provide the analyst with the opportunity to determine the analytes by using simple aqueous standards to prepare calibration lines. Within the limits of the samples analyzed, the method developed is independent of matrix.
Resumo:
Improvements have been made on the currently available hydride generator system manufactured by SpectraMetrics Incorporated, because the system was found to be unsatisfactory with respect to the following: 1. the drying agent, anhydrous calcium chloride, 2. the special sample tube, 3. the direction of argon flow through the Buchner funnel when it came to dealing with real sample, that is, with reference only to aqueous extracts of soil samples. Changes that were made on the system included the replacement of anhydrous calcium chloride with anhydrous calcium sulphate and the replacement of the special sample tube with a modified one made from silica. Re-directing the flow of argon through the top of the Buchner funnel appeared to make the system compatible with aqueous extracts of soil samples. The interferences from 1000 ~g/mL of nickel(II) , cobalt(II), iron(III), copper(II) have been eliminated with the aid of 1.4 M hydrochloric acid and 1% (weight/volume) L-cystine. Greater than 90% recovery of 0.3 ~g/mL arsenic signal was achieved in each case. Furthermore, 103% of arsenic signal was accomplished in the presence of 1000 ~g/mL cadmium with 5 M Hel. tVhen each of the interferents was present in solution at 1000 ppm, a recovery of 85% was achieved by using 5 M hydrochloric acid and 3% (weight/volume) L-cystine. Without L-cystine and when 1.4 M hydrochloric acid was used, the recoveries were 0% (Ni), 0% (Co), 88% (Fe), 15% (Cu), 18% (Cd). Similarly, a solution containing 1000 ppm of each interferent gave a zero percent recovery of arsenic. The reduction of trivalent and pentavalent arsenic at a pH less than one has also been investigated and shown to be quantitative if peak areas are measured. The reproducibility determination of a 0.3 Vg/mL standard arsenic solution by hydride generation shows a relative standard deviation of 3.4%. The detection limits with and without Porapak Q have been found to be 0.6 ng/mL and 1.0 ng/mL, respectively.
Resumo:
Photosynthetic state transitions were investigated in the cyanobacterium Synechococcus sp. PCC 6301 by studying fluorescence emission, heat loss, and PS I activity in intact cells brought to state 1 and state 2. 77K fluorescence emission spectra were modelled with a sum of 6 components corresponding to PBS, PS II, and PS I emissions. The modelled data showed a large decrease in PS II fluorescence accompanied with a small increase in the PS I fluorescence upon transition to state 2 for excitation wavelengths absorbed by both PBS and ChI ll.. The fluorescence changes seen with ChI .a. excitations do not support the predictions of the mobile PBS model of state transition in PBS-containing organisms. Measurements of heat loss from intact cells in the two states were similar for both ChI it. and PBS excitations over three orders of magnitude of laser flash intensity. This suggests that the PBS does not become decoupled from PS II in state 2 as proposed by the PBS detachment model of state transition in PBS-containing organisms. PS I activity measurements done on intact cells showed no difference in the two states, in contrast with the predictions of all of the existing models of state transitions. Based on these results a model for state transition In PBScontaining organisms is proposed, with a PS II photoprotectory function.
Resumo:
Central administration of orexin-A has been shown to activate autonomic arousal in rats, reliably inducing anxiety-like behaviours in the open field. To date, there has yet to be a study investigating the role of orexin-A in the communication of such negative affective state. In the current study, forty-six adult male rats were chronically cannulated and administered orexin-A into the medial preoptic area/anterior hypothalamic area to determine the effect of this neuropeptide on anxiety-like behaviour and the production of 22 kHz aversive ultrasonic vocalizations. It was found that intracerebral administration of orexin-A increased autonomic arousal as measured by a significant increase in fecal boli output, however orexin-A did not significantly affect locomotor activity or induce 22 kHz calling. These data suggest that orexin-A is involved in the regulation of the autonomic aspect of anxiety-like behaviour but not in the vocal communication of such negative affect
Resumo:
An illustration from the "Canadian Illustrated News" that shows a group of individuals "gathering the fruit" and then a "scene in the vineyard".
Resumo:
UANL
Resumo:
Article publié avec l'autorisation de la Chambre des notaires du Québec
Resumo:
Yann Joly, étudiant au doctorat en droit à l'Université McGill (Montréal)
Resumo:
Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques.
Resumo:
Les modèles de compréhension statistiques appliqués à des applications vocales nécessitent beaucoup de données pour être entraînés. Souvent, une même application doit pouvoir supporter plusieurs langues, c’est le cas avec les pays ayant plusieurs langues officielles. Il s’agit donc de gérer les mêmes requêtes des utilisateurs, lesquelles présentent une sémantique similaire, mais dans plusieurs langues différentes. Ce projet présente des techniques pour déployer automatiquement un modèle de compréhension statistique d’une langue source vers une langue cible. Ceci afin de réduire le nombre de données nécessaires ainsi que le temps relié au déploiement d’une application dans une nouvelle langue. Premièrement, une approche basée sur les techniques de traduction automatique est présentée. Ensuite une approche utilisant un espace sémantique commun pour comparer plusieurs langues a été développée. Ces deux méthodes sont comparées pour vérifier leurs limites et leurs faisabilités. L’apport de ce projet se situe dans l’amélioration d’un modèle de traduction grâce à l’ajout de données très proche de l’application ainsi que d’une nouvelle façon d’inférer un espace sémantique multilingue.
Resumo:
Nous proposons une approche basée sur la formulation interactive des requêtes. Notre approche sert à faciliter des tâches d’analyse et de compréhension du code source. Dans cette approche, l’analyste utilise un ensemble de filtres de base (linguistique, structurel, quantitatif, et filtre d’interactivité) pour définir des requêtes complexes. Ces requêtes sont construites à l’aide d’un processus interactif et itératif, où des filtres de base sont choisis et exécutés, et leurs résultats sont visualisés, changés et combinés en utilisant des opérateurs prédéfinis. Nous avons évalués notre approche par l’implantation des récentes contributions en détection de défauts de conception ainsi que la localisation de fonctionnalités dans le code. Nos résultats montrent que, en plus d’être générique, notre approche aide à la mise en œuvre des solutions existantes implémentées par des outils automatiques.