934 resultados para Direct modified method
Resumo:
F. psychrophilum is the causative agent of Bacterial Cold Water Disease (BCW) and Rainbow Trout Fry Syndrome (RTFS). To date, diagnosis relies mainly on direct microscopy or cultural methods. Direct microscopy is fast but not very reliable, whereas cultural methods are reliable but time-consuming and labor-intensive. So far fluorescent in situ hybridization (FISH) has not been used in the diagnosis of flavobacteriosis but it has the potential to rapidly and specifically detect F. psychrophilum in infected tissues. Outbreaks in fish farms, caused by pathogenic strains of Flavobacterium species, are increasingly frequent and there is a need for reliable and cost-effective techniques to rapidly diagnose flavobacterioses. This study is aimed at developing a FISH that could be used for the diagnosis of F. psychrophilum infections in fish. We constructed a generic probe for the genus Flavobacterium ("Pan-Flavo") and two specific probes targeting F. psychrophilum based on 16S rRNA gene sequences. We tested their specificity and sensitivity on pure cultures of different Flavobacterium and other aquatic bacterial species. After assessing their sensitivity and specificity, we established their limit of detection and tested the probes on infected fresh tissues (spleen and skin) and on paraffin-embedded tissues. The results showed high sensitivity and specificity of the probes (100% and 91% for the Pan-Flavo probe and 100% and 97% for the F. psychrophilum probe, respectively). FISH was able to detect F. psychrophilum in infected fish tissues, thus the findings from this study indicate this technique is suitable as a fast and reliable method for the detection of Flavobacterium spp. and F. psychrophilum.
Resumo:
OBJECTIVE To clinically evaluate the treatment of Miller Class I and II multiple adjacent gingival recessions using the modified coronally advanced tunnel technique combined with a newly developed bioresorbable collagen matrix of porcine origin. METHOD AND MATERIALS Eight healthy patients exhibiting at least three multiple Miller Class I and II multiple adjacent gingival recessions (a total of 42 recessions) were consecutively treated by means of the modified coronally advanced tunnel technique and collagen matrix. The following clinical parameters were assessed at baseline and 12 months postoperatively: full mouth plaque score (FMPS), full mouth bleeding score (FMBS), probing depth (PD), recession depth (RD), recession width (RW), keratinized tissue thickness (KTT), and keratinized tissue width (KTW). The primary outcome variable was complete root coverage. RESULTS Neither allergic reactions nor soft tissue irritations or matrix exfoliations occurred. Postoperative pain and discomfort were reported to be low, and patient acceptance was generally high. At 12 months, complete root coverage was obtained in 2 out of the 8 patients and 30 of the 42 recessions (71%). CONCLUSION Within their limits, the present results indicate that treatment of Miller Class I and II multiple adjacent gingival recessions by means of the modified coronally advanced tunnel technique and collagen matrix may result in statistically and clinically significant complete root coverage. Further studies are warranted to evaluate the performance of collagen matrix compared with connective tissue grafts and other soft tissue grafts.
Resumo:
The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.
Resumo:
In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could serve a dual function as a fiducial marker for image guided radiation therapy (IGRT) treatment if it could be modified to be visible on x-rays. In this study, modifications to the MOSFET dosimeter were made to increase its visibility for IGRT treatment. To test whether the modifications hindered the dosimeter’s ability to accurately measure and transmit dose information, the energy dependence, angular dependence and wireless read range of the modified dosimeter were measured and compared to unmodified dosimeters. It was found that the modified dosimeter performed as well as the unmodified dosimeter while also being suitable for use as a fiducial marker for IGRT treatment.
Resumo:
High reflective materials in the microwave region play a very important role in the realization of antenna reflectors for a broad range of applications, including radiometry. These reflectors have a characteristic emissivity which needs to be characterized accurately in order to perform a correct radiometric calibration of the instrument. Such a characterization can be performed by using open resonators, waveguide cavities or by radiometric measurements. The latter consists of comparative radiometric observations of absorbers, reference mirrors and the sample under test, or using the cold sky radiation as a direct reference source. While the first two mentioned techniques are suitable for the characterization of metal plates and mirrors, the latter has the advantages to be also applicable to soft materials. This paper describes how, through this radiometric techniques, it is possible to characterize the emissivity of the sample relative to a reference mirror and how to characterize the absolute emissivity of the latter by performing measurements at different incident angles. The results presented in this paper are based on our investigations on emissivity of a multilayer insulation material (MLI) for space mission, at the frequencies of 22 and 90 GHz.
Resumo:
OBJECTIVES To clinically evaluate the healing of mandibular Miller Class I and II isolated gingival recessions treated with the modified coronally advanced tunnel (MCAT) in conjunction with an enamel matrix derivative (EMD) and subepithelial connective tissue graft (SCTG). METHOD AND MATERIALS Sixteen healthy patients (13 women and 3 men) exhibiting one isolated mandibular Miller Class I and II gingival recessions of a depth of ≥ 3 mm, were consecutively treated with the MCAT in conjunction with EMD and SCTG. Treatment outcomes were assessed at baseline and at 12 months postoperatively. The primary outcome variable was complete root coverage (CRC) (eg, 100% root coverage). RESULTS Postoperative pain and discomfort were low and no complications such as postoperative bleeding, allergic reactions, abscesses, or loss of SCTG were observed. At 12 months, statistically significant (P < .0001) root coverage was obtained in all 16 defects. CRC was measured in 12 out of the 16 cases (75%) while in the remaining 4 defects root coverage amounted to 90% (in two cases) and 80% (in two cases), respectively. Mean root coverage was 96.25%. Mean keratinized tissue width increased from 1.98 ± 0.8 mm at baseline to 2.5 ± 0.9 mm (P < .0001) at 12 months, while mean probing depth did not show any statistically significant changes (ie, 1.9 ± 0.3 mm at baseline vs 1.8 ± 0.2 mm at 12 months). CONCLUSION Within their limits, the present results indicate that the described treatment approach may lead to predictable root coverage of isolated mandibular Miller Class I and II gingival recessions.
Resumo:
PURPOSE A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.
Resumo:
The sensitivity of the gas flow field to changes in different initial conditions has been studied for the case of a highly simplified cometary nucleus model. The nucleus model simulated a homogeneously outgassing sphere with a more active ring around an axis of symmetry. The varied initial conditions were the number density of the homogeneous region, the surface temperature, and the composition of the flow (varying amounts of H2O and CO2) from the active ring. The sensitivity analysis was performed using the Polynomial Chaos Expansion (PCE) method. Direct Simulation Monte Carlo (DSMC) was used for the flow, thereby allowing strong deviations from local thermal equilibrium. The PCE approach can be used to produce a sensitivity analysis with only four runs per modified input parameter and allows one to study and quantify non-linear responses of measurable parameters to linear changes in the input over a wide range. Hence the PCE allows one to obtain a functional relationship between the flow field properties at every point in the inner coma and the input conditions. It is for example shown that the velocity and the temperature of the background gas are not simply linear functions of the initial number density at the source. As probably expected, the main influence on the resulting flow field parameter is the corresponding initial parameter (i.e. the initial number density determines the background number density, the temperature of the surface determines the flow field temperature, etc.). However, the velocity of the flow field is also influenced by the surface temperature while the number density is not sensitive to the surface temperature at all in our model set-up. Another example is the change in the composition of the flow over the active area. Such changes can be seen in the velocity but again not in the number density. Although this study uses only a simple test case, we suggest that the approach, when applied to a real case in 3D, should assist in identifying the sensitivity of gas parameters measured in situ by, for example, the Rosetta spacecraft to the surface boundary conditions and vice versa.
Resumo:
The traditional Newton method for solving nonlinear operator equations in Banach spaces is discussed within the context of the continuous Newton method. This setting makes it possible to interpret the Newton method as a discrete dynamical system and thereby to cast it in the framework of an adaptive step size control procedure. In so doing, our goal is to reduce the chaotic behavior of the original method without losing its quadratic convergence property close to the roots. The performance of the modified scheme is illustrated with various examples from algebraic and differential equations.
Resumo:
Progress toward elucidating the 3D structures of eukaryotic membrane proteins has been hampered by the lack of appropriate expression systems. Recent work using the Xenopus oocyte as a novel expression system for structural analysis demonstrates the capability of providing not only the significant amount of protein yields required for structural work but also the expression of eukaryotic membrane proteins in a more native and functional conformation. There is a long history using the oocyte expression system as an efficient tool for membrane transporter and channel expression in direct functional analysis, but improvements in robotic injection systems and protein yield optimization allow the rapid scalability of expressed proteins to be purified and characterized in physiologically relevant structural states. Traditional overexpression systems (yeast, bacteria, and insect cells) by comparison require chaotropic conditions over several steps for extraction, solubilization, and purification. By contrast, overexpressing within the oocyte system for subsequent negative-staining transmission electron microscopy studies provides a single system that can functionally assess and purify eukaryotic membrane proteins in fewer steps maintaining the physiological properties of the membrane protein.
Resumo:
Rolling Circle Amplification (RCA) is an isothermal enzymatic method generating single-stranded DNA products consisting of concatemers containing multiple copies of the reverse complement of the circular template precursor. Little is known on the compatibility of modified nucleoside triphosphates (dN*TPs) with RCA, which would enable the synthesis of long, fully modified ssDNA sequences. Here, dNTPs modified at any position of the scaffold were shown to be compatible with rolling circle amplification, yielding long (>1 kb), and fully modified single-stranded DNA products. This methodology was applied for the generation of long, cytosine-rich synthetic mimics of telomeric DNA. The resulting modified oligo-nucleotides displayed an improved resistance to fetal bovine serum.
Resumo:
The concentration of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in whole blood is used as a parameter for assessing the consumption behavior of cannabis consumers. The blood level of THCCOOH-glucuronide might provide additional information about the frequency of cannabis use. To verify this assumption, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and direct quantification of free and glucuronidated THCCOOH in human whole blood was newly developed. The method comprised protein precipitation, followed by injection of the processed sample onto a trapping column and subsequent gradient elution to an analytical column for separation and detection. The total LC run time was 4.5 min. Detection of the analytes was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was fully validated by evaluating the following parameters: linearity, lower limit of quantification, accuracy and imprecision, selectivity, extraction efficiency, matrix effect, carry-over, dilution integrity, analyte stability, and re-injection reproducibility. All acceptance criteria were analyzed and the predefined criteria met. Linearity ranged from 5.0 to 500 μg/L for both analytes. The method was successfully applied to whole blood samples from a large collective of cannabis consumers, demonstrating its applicability in the forensic field.
Resumo:
Five test runs were performed to assess possible bias when performing the loss on ignition (LOI) method to estimate organic matter and carbonate content of lake sediments. An accurate and stable weight loss was achieved after 2 h of burning pure CaCO3 at 950 °C, whereas LOI of pure graphite at 530 °C showed a direct relation to sample size and exposure time, with only 40-70% of the possible weight loss reached after 2 h of exposure and smaller samples losing weight faster than larger ones. Experiments with a standardised lake sediment revealed a strong initial weight loss at 550 °C, but samples continued to lose weight at a slow rate at exposure of up to 64 h, which was likely the effect of loss of volatile salts, structural water of clay minerals or metal oxides, or of inorganic carbon after the initial burning of organic matter. A further test-run revealed that at 550 °C samples in the centre of the furnace lost more weight than marginal samples. At 950 °C this pattern was still apparent but the differences became negligible. Again, LOI was dependent on sample size. An analytical LOI quality control experiment including ten different laboratories was carried out using each laboratory's own LOI procedure as well as a standardised LOI procedure to analyse three different sediments. The range of LOI values between laboratories measured at 550 °C was generally larger when each laboratory used its own method than when using the standard method. This was similar for 950 °C, although the range of values tended to be smaller. The within-laboratory range of LOI measurements for a given sediment was generally small. Comparisons of the results of the individual and the standardised method suggest that there is a laboratory-specific pattern in the results, probably due to differences in laboratory equipment and/or handling that could not be eliminated by standardising the LOI procedure. Factors such as sample size, exposure time, position of samples in the furnace and the laboratory measuring affected LOI results, with LOI at 550 °C being more susceptible to these factors than LOI at 950 °C. We, therefore, recommend analysts to be consistent in the LOI method used in relation to the ignition temperatures, exposure times, and the sample size and to include information on these three parameters when referring to the method.
Resumo:
Zoonotic diseases have a significant impact on public health globally. To prevent or reduce future zoonotic outbreaks, there is a constant need to invest in research and surveillance programs while updating risk management strategies. However, given the limited resources available, disease prioritization based on the need for their control and surveillance is important. This study was performed to identify and weight disease criteria for the prioritization of zoonotic diseases in Switzerland using a semi-quantitative research method based on expert opinion. Twenty-eight criteria relevant for disease control and surveillance, classified under five domains, were selected following a thorough literature review, and these were evaluated and weighted by seven experts from the Swiss Federal Veterinary Office using a modified Delphi panel. The median scores assigned to each criterion were then used to rank 16 notifiable and/or emerging zoonoses in Switzerland. The experts weighted the majority of the criteria similarly, and the top three criteria were Severity of disease in humans, incidence and prevalence of the disease in humans and treatment in humans. Based on these weightings, the three highest ranked diseases were Avian Influenza, Bovine Spongiform Encephalitis, and Bovine Tuberculosis. Overall, this study provided a preliminary list of criteria relevant for disease prioritization in Switzerland. These were further evaluated in a companion study which involved a quantitative prioritization method and multiple stakeholders.
Resumo:
BACKGROUND AND PURPOSE Five randomized controlled trials have consistently shown that mechanical thrombectomy (MT) in addition to best medical treatment (±intravenous tissue-type plasminogen activator) improves outcome after acute ischemic stroke in patients with large artery anterior circulation stroke. Whether direct MT is equally effective as combined intravenous thrombolysis with MT (ie, bridging thrombolysis) remains unclear. METHODS We retrospectively compared clinical and radiological outcomes in 167 bridging patients with 255 patients receiving direct MT because of large artery anterior circulation stroke. We matched all patients from the direct MT group who would have qualified for intravenous tissue-type plasminogen activator with controls from the bridging group, using multivariate and propensity score analyses. Functional independence was defined as modified Rankin Scale score of 0 to 2. RESULTS From February 2009 to August 2014, 40 patients from the direct MT group would have qualified for bridging thrombolysis but were treated with MT only. Clinical and radiological characteristics did not differ from the bridging cohort, except for higher rates of hypercholesterolemia (P=0.019), coronary heart disease (P=0.039), and shorter intervals from symptom onset to endovascular intervention (P=0.01) in the direct MT group. Functional independence, mortality, and intracerebral hemorrhage rates did not differ (P>0.1). After multivariate matching analysis outcome in both groups did not differ, except for lower rates of asymptomatic intracerebral hemorrhage (P=0.023) and lower mortality (P=0.007) in the direct MT group. CONCLUSIONS In patients with large anterior circulation stroke, direct mechanical intervention seems to be equally effective as bridging thrombolysis. A randomized trial comparing direct MT with bridging therapy is warranted.