945 resultados para Diagram linkz
Resumo:
In the quantum Hall regime, the longitudinal resistivity rho (xx) plotted as a density-magnetic-field (n (2D) -B) diagram displays ringlike structures due to the crossings of two sets of spin split Landau levels from different subbands [see, e.g., Zhang et al., in Phys. Rev. Lett. 95:216801, 2005. For tilted magnetic fields, some of these ringlike structures ""shrink"" as the tilt angle is increased and fully collapse at theta (c) a parts per thousand 6A degrees. Here we theoretically investigate the topology of these structures via a non-interacting model for the 2DEG. We account for the inter Landau-level coupling induced by the tilted magnetic field via perturbation theory. This coupling results in anticrossings of Landau levels with parallel spins. With the new energy spectrum, we calculate the corresponding n (2D) -B diagram of the density of states (DOS) near the Fermi level. We argue that the DOS displays the same topology as rho (xx) in the n (2D) -B diagram. For the ring with filling factor nu=4, we find that the anticrossings make it shrink for increasing tilt angles and collapse at a large enough angle. Using effective parameters to fit the theta=0A degrees data, we find a collapsing angle theta (c) a parts per thousand 3.6A degrees. Despite this factor-of-two discrepancy with the experimental data, our model captures the essential mechanism underlying the ring collapse.
Resumo:
The nonequilibrium phase transition of the one-dimensional triplet-creation model is investigated using the n-site approximation scheme. We find that the phase diagram in the space of parameters (gamma, D), where gamma is the particle decay probability and D is the diffusion probability, exhibits a tricritical point for n >= 4. However, the fitting of the tricritical coordinates (gamma(t), D(t)) using data for 4 <= n <= 13 predicts that gamma(t) becomes negative for n >= 26, indicating thus that the phase transition is always continuous in the limit n -> infinity. However, the large discrepancies between the critical parameters obtained in this limit and those obtained by Monte Carlo simulations, as well as a puzzling non-monotonic dependence of these parameters on the order of the approximation n, argue for the inadequacy of the n-site approximation to study the triplet-creation model for computationally feasible values of n.
Resumo:
The Early Paleozoic geodynamic evolution in SW Iberia is believed to have been dominated by the opening of the Rheic Ocean. The Rheic Ocean is generally accepted to have resulted from the drift of peri-Gondwanan terranes such as Avalonia from the northern margin of Gondwana during Late Cambrian-Early Ordovician times. The closure of the Rheic Ocean was the final result of a continent-continent collision between Gondwana and Laurussia that produced the Variscan orogen. The Ossa-Morena Zone is a peri-Gondwana terrane, which preserves spread fragments of ophiolites - the Internal Ossa-Morena Zones Ophiolite Sequences (IOMZOS). The final patchwork of the IOMZOS shows a complete oceanic lithospheric sequence with geochemical characteristics similar to the ocean-floor basalts, without any orogenic fingerprint and/or crustal contamination. The IOMZOS were obducted and imbricated with high pressure lithologies. Based on structural, petrological and whole-rock geochemical data, the authors argue that the IOMZOS represent fragments of the oceanic lithosphere from the Rheic Ocean. Zircon SHRIMP U-Pb geochronological data on metagabbros point to an age of ca. 480 Ma for IOMZOS, providing evidence of a well-developed ocean in SW Iberia during this period, reinforcing the interpretation of the Rheic Ocean as a wide ocean among the peri-Gondwanan terranes during Early Ordovician times.
Resumo:
The problem of classification of Jordan bit-nodules over (non-semisimple) finite dimensional Jordan algebras with respect to their representation type is considered. The notions of diagram of a Jordan algebra and of Jordan tensor algebra of a bimodule are introduced and a mapping Qui is constructed which associates to the diagram of a Jordan algebra J the quiver of its universal associative enveloping algebra S(J). The main results are concerned with Jordan algebras of semi-matrix type, that is, algebras whose semi-simple component is a direct sum of Jordan matrix algebras. In this case, criterion of finiteness and tameness for one-sided representations are obtained, in terms of diagram and mapping Qui, for Jordan tensor algebras and for algebras with radical square equals to 0. (c) 2010 Elsevier Inc. All rights reserved.
Resumo:
The interaction of 4-nerolidylcatechol (4-NRC), a potent antioxidant agent, and 2-hydroxypropyl-beta-cyclodextrin (HP-beta-CD) was investigated by the solubility method using Fourier transform infrared (FTIR) methods in addition to UV-Vis, (1)H-nuclear magnetic resonance (NMR) spectroscopy and molecular modeling. The inclusion complexes were prepared using grinding, kneading and freeze-drying methods. According to phase solubility studies in water a B(S)-type diagram was found, displaying a stoichiometry complexation of 2:1 (drug:host) and stability constant of 6494 +/- A 837 M(-1). Stoichiometry was established by the UV spectrophotometer using Job`s plot method and, also confirmed by molecular modeling. Data from (1)H-NMR, and FTIR, experiments also provided formation evidence of an inclusion complex between 4-NRC and HP-beta-CD. 4-NRC complexation indeed led to higher drug solubility and stability which could probably be useful to improve its biological properties and make it available to oral administration and topical formulations.
Resumo:
A novel material comprised of bacterial cellulose (BC) and Laponite clay with different inorganic organic ratios (m/m) was prepared by the contact of never-dried membranes of BC with a previous dispersion of clay particles in water. Field emission scanning electron microscopy (FE-SEM) data of composite materials revealed an effective adhesion of clay over the surface of BC membrane; inorganic particles also penetrate into the polymer bulk, with a significant change of the surface topography even at 5% of clay loading. As a consequence, the mechanical properties are deeply affected by the presence of clay, increasing the values of the Young modulus and the tensile strength. However the maximum strain is decreased when the clay content is increased in the composite in comparison to pristine BC. The main weight loss step of the composites is shifted towards higher temperatures compared to BC, indicating that the clay particles slightly protect the polymer from thermal and oxidative decomposition. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Användningen av ljud skiljer sig åt mellan de olika filmgenrerna skräck, komedi, action och drama. Det finns vissa ljud som används oftare för att förstärka de känslor, som filmmakarna vill att vi ska uppleva i samband med vad vi ser i filmen. I denna uppsats analyseras ljudet i ett antal nyckelscener i vissa filmer. För att ta ut dessa nyckelscener användes Hollywoodmallen för hur man skriver film, såsom den beskrivs av Viki King. Genom att jämföra resultaten, även genom diagram, har jag upptäckt att metalljud från vapen och liknande, gör oss rädda. Syrsors knirpande tyder på mörker och ensamhet, och vattenljud som regn kan göra oss nedstämda eller oroliga. Detta är tre typiska ljud i filmgenren skräck. Fågelkvitter får oss gärna på bra humör. Ljud från andra människor som pratar innebär att vi inte är ensamma. Dessa ljud används ofta i komedier och dramafilmer. Actionfilmer är mer anpassningsbara och använder ljud som kan passa i olika genrer, så länge det tyder på att något händer.
Resumo:
Syftet med denna uppsats är att ta reda på hur många som har lämnat a-kassorna, inom ett par utvalda yrkesgrupper, inom den kommunala sektorn i Borlänge och vad orsaken/orsakerna till utträdet är, samt att ta reda på hur många som har funderat på att lämna a-kassan och orsaken/orsakerna till det För att kunna ta reda på det, har en enkätundersökning gjorts. Enkäten skickades ut till två yrkesgrupper inom den kommunala sektorn i Borlänge, barnskötare och lärare för årskurs 1-3. Resultatet av denna undersökning, redovisas i diagram och till viss del skriftligen. Resultaten visar på att det, procentuellt, sett var fler lärare än barnskötare som lämnat a-kassan, samt att det var fler barnskötare än lärare som funderat på att lämna a-kassan. De främsta orsakerna till att medlemmarna lämnat, eller funderar på att lämna, a-kassan är närmande till pension och den förhöjda avgiften.
Resumo:
The purpose of the work is to develop a cost effective semistationary CPC concentrator for a string PV-module. A novel method of using annual irradiation distribution diagram projected in a north-south vertical plane is developed. This method allows us easily to determine the optimum acceptance angle of the concentrator and the required number of annual tilts. Concentration ranges of 2-5x are investigated with corresponding acceptance angles between 5 and 15°. The concentrator should be tilted 2-6 times per year. Experiments has been performed on a string module of 10 cells connected in a series and equipped with a compound parabolic concentrator with C = 3.3X. Measurement show that the output will increase with a factor of 2-2.5 for the concentrator module, compared to a reference module without concentrator. If very cheap aluminium reflectors are used the costs for the PV-module can be decreased nearly by a factor of two.
Resumo:
This report describes the work done creating a computer model of a kombi tank from Consolar. The model was created with Presim/Trnsys and Fittrn and DF were used to identify the parameters. Measurements were carried out and were used to identify the values of the parameters in the model. The identifications were first done for every circuit separately. After that, all parameters are normally identified together using all the measurements. Finally the model should be compared with other measurements, preferable realistic ones. The two last steps have not yet been carried out, because of problems finding a good model for the domestic hot water circuit.The model of the domestic hot water circuit give relatively good results for low flows at 5 l/min, but is not good for higher flows. In the report suggestions for improving the model are given. However, there was not enough time to test this within the project as much time was spent trying to solve problems with the model crashing. Suggestions for improving the model for the domestic circuit are given in chapter 4.4. The improved equations that are to be used in the improved model are given by equation 4.18, 4.19 and 4.22.Also for the boiler circuit and the solar circuit there are improvements that can be done. The model presented here has a few shortcomings, but with some extra work, an improved model can be created. In the attachment (Bilaga 1) is a description of the used model and all the identified parameters.A qualitative assessment of the store was also performed based on the measurements and the modelling carried out. The following summary of this can be given: Hot Water PreparationThe principle for controlling the flow on the primary side seems to work well in order to achieve good stratification. Temperatures in the bottom of the store after a short use of hot water, at a coldwater temperature of 12°C, was around 28-30°C. This was almost independent of the temperature in the store and the DHW-flow.The measured UA-values of the heat exchangers are not very reliable, but indicates that the heat transfer rates are much better than for the Conus 500, and in the same range as for other stores tested at SERC.The function of the mixing valve is not perfect (see diagram 4.3, where Tout1 is the outlet hot water temperature, and Tdhwo and Tdhw1 is the inlet temperature to the hot and cold side of the valve respectively). The outlet temperature varies a lot with different temperatures in the storage and is going down from 61°C to 47°C before the cold port is fully closed. This gives a problem to find a suitable temperature setting and gives also a risk that the auxiliary heating is increased instead of the set temperature of the valve, when the hot water temperature is to low.Collector circuitThe UA-value of the collector heat exchanger is much higher than the value for Conus 500, and in the same range as the heat exchangers in other stores tested at SERC.Boiler circuitThe valve in the boiler circuit is used to supply water from the boiler at two different heights, depending on the temperature of the water. At temperatures from the boiler above 58.2°C, all the water is injected to the upper inlet. At temperatures below 53.9°C all the water is injected to the lower inlet. At 56°C the water flow is equally divided between the two inlets. Detailed studies of the behaviour at the upper inlet shows that better accuracy of the model would have been achieved using three double ports in the model instead of two. The shape of the upper inlet makes turbulence, that could be modelled using two different inlets. Heat lossesThe heat losses per m3 are much smaller for the Solus 1050, than for the Conus 500 Storage. However, they are higher than those for some good stores tested at SERC. The pipes that are penetrating the insulation give air leakage and cold bridges, which could be a major part of the losses from the storage. The identified losses from the bottom of the storage are exceptionally high, but have less importance for the heat losses, due to the lower temperatures in the bottom. High losses from the bottom can be caused by air leakage through the insulation at the pipe connections of the storage.
Resumo:
Dagens vanliga ackumulatortanksystem har för dålig skiktning i ackumulatortanken, vilket leder till försämrad effektivitet hos systemen. För att förbättra den krävs komponenter, som kan ladda och framförallt urladda med bättre skiktningsegenskaper. Ackumulatorvärmesystem som t ex vedpanna med tank och solvärmesystem kan öka sin effektivitet, om tankens skiktning främjas. En ny typ av varmvattenberedare, sk tappvattenautomater har tagits fram bl a för att ersätta trasiga eller igenkalkade varmvattenberedare i villapannor. Dessa tappvattenautomater har visat sig kunna vara intressanta även för anslutning till ackumulatortankar. Konsumentverket gav SERC uppdraget att testa dessa nya automater för att se hur väl de fungerar i ackumulatorsystem. Vi har testat tre olika fabrikat: Alfajet, Cetetherm och Solvis. Cetetherm provades förutom i grundversionen med trevägsventil, även med en tvåvägsventil. Totalt testades således fyra olika konstruktioner, som skiljer sig i värmeväxlarstorlek och reglerstrategi. I rapporten visas driftsegenskaper och termiska prestanda för tappvattenautomaterna med hjälp av diagram, som upprättades efter omfattande mätningar. Tappvattenautomaterna, som i grundutförande var avsedda för värmepannor, är inte lämpliga för användning tillsammans med ackumulatortank. Tappvattenautomater med god termisk prestanda och till ackumulatorsystem anpassad reglerstrategi ger däremot gott resultat. Alfajet och Cetetherm med trevägsventil är mindre lämpade för ackumulatorvärme-system. En onödigt hög returtemperatur till ackumulatortanken leder till dålig skiktning vid urladdning och därigenom kan en mindre del av energiinnehållet i tanken tillgodogöras. Genom att ersätta trevägsventilen hos Cetetherm med en tvåvägsventil, förbättras den termiska funktionen vid användning med ackumulatortank. Solvis tappvattenautomat var från början konstruerad för solvärmesystem med ackumulatortank och visade sig ha god prestanda. Tappvattenautomaterna testades även med avseende på varmvattenkomforten vid flödesändringar. Ingen av tappvattenautomaterna visade sig kunna reglera varmvattentemperaturen lika bra som ett traditionellt system med väl fungerande blandningsventil. Tappvattenautomatens inverkan på ett solvärmesystems täckningsgrad under sommarhalvårets väderförhållanden testades i SERCs sexdagarstest. I jämförelse till de hittills bästa konventionella system med inbyggda värmeväxlare av typ kamflänsrör kunde täckningsgraden för ett i övrigt likvärdigt system höjas med upp till 15 procentenheter. Marknadspriset för tappvattenautomater på omkring 10 000 kr är fortfarande för högt, för att den skall kunna konkurrera med konventionella system. Vidareutvecklade förenklade system, som produceras i större serier kommer enligt vår bedömning att kunna erbjudas till lägre pris i framtiden.
Resumo:
Del 1:Innehållsförteckning och korta sammanfattningarDEL 2:Verksamhetsberättelsen för perioden maj 1992 till april 1993 beskriver de arbeten som har gjorts av villasolvärmegruppen på SERC efter den inledande studie (SERC/UCFB-91/0039), där villasolvärmesystem kartlades. Följande arbeten beskrivs:- Utveckling av lågflödessystem och internationella kontakter- Uppbyggnad av värmelaboratorium på SERC- Praktiska test av värmelagringsenheten- Praktiska test av nya systemkomponenter i solvärmekretsen- Datasimulering inkluderande nyutvecklade systemkomponenterI verksamhetsplanen beskrivs huvudmålet för de arbeten som ska utföras under trårsperioden 93 - 96. Mera detaljerat beskrivs de arbeten som ska utföras under budgetåret 1993/94:- Beräkningsprogram för nogrannare dimensionering av finrörsvärmeväxlare- Konstruktion av maskiner för värmeväxlartillverkning- Utveckling av värmeväxlare för tappvarmvatten- Simuleringsberäkningar för hela systemet med PRESIM/TRNSYS.DEL 3:Del 3 innehåller en redovisning av mätresultat för den undersökta kombitanken. Temperaturförloppen på olika höjd i tankens har studerats vid uppvärmning genom solvärmeväxlaren och nedkylning genom tappning av varmvatten. Resultaten diskuteras kvalitativt och redovisas kvantitativt i form av diagram. Mätresultaten på två prototyper av den på SERC utvecklade finrörsvärmeväxlaren redovisas och diskuteras i jämförelse till traditionell värmeväxlare. De erhållna mätresultaten används som ingångsvärden för simuleringsberäkningar med PRESIM/TRNSYS. Problemen med de i PRESIM/TRNSYS befintliga modellerna diskuteras. De utförda modellberäkningarna tillåter en uppskattning av möjliga förbättringar i form av höjd årsverkningsgrad för ett svenskt villasolvärmesystem med kombitank. I del 3 redovisas dessutom de mätningar som har utförts på otika pumpar vilka skulle kunna användas i solfångarkretsen. Sex olika pumpar analyseras och diskuteras. Del 3 har följande rubriker:- Beskrivning av den undersökta lagringstanken- Mätningar på tappvarmvattenväxlare- Mätningar på solvärmeväxlare (kamflänsrör och finrörsvärmeväxlare)- Simuleringsberäkningar- PumpmätningarDEL 4:Del 4 innehåller publicerade rapporter under 1992 och 93 samt patentansökan för SERC?s finrörsvärmeväxlare: - NORTH SUN 1992, Solar Energy at High Latitudes, June 24-26 1992 Trondheim, Norway. Domestic solar heating system - a systematic study i progress Patentansökan på finrorsvärmeväxlare till Patent- och Registreringsverket från 93 01 23. ISES SOLAR WORLD CONGRESS, 23-27 augusti 1993, Budapest, HUNGARY Criteria for cost efficient small scale solar hot water installations.DEL 5:Del 5 hänvisar till rapporterna från IEA Task-1 4 mötena om solfångarsystem i- Hameln, Tyskland, augusti 1992 och- Rom, Italien, januari 1993.I rapporterna beskrivs aktiviteten inom den internationella arbetsgruppen speciellt med hänsyn på utveckling av villasolvärmesystem. I Rom presenterades principlösningen för den på SERC utvecklade finrörsvärmeväxlare. De har publicerats separat som nr 42 och 46 i SERCs rapportserie.
Resumo:
Syftet med examensarbetet är att studera den subsynkrona interaktionen (subsynchronous torsional interaktion, SSTI) mellan ett HVDC system med spänningsstyva strömriktare och en närliggande generator. Studien utförs med hjälp av datorsimuleringar och fokuserar på att studera dämpkaraktäristiken för SSTI. Studien ska visa hur faktorer såsom den överförda effektens storlek och riktning, vald driftmod och kraftsystemets kortslutningseffekt påverkar dämpkaraktäristiken. Rapporten beskriver subsynkron oscillation (SSO) och tillvägagångssättet vid en SSTI undersökning. En kort introduktion till HVDC Light ges. Studien visar att HVDC Light ökar dämpningen för det frekvensområde som är intressant. Resultaten presenteras som diagram med beräknad dämpkaraktäristik.
Resumo:
Recent developments in biological research, has shown that the initial maximum permissible exposure (MPE) limits for protection of workers from risks associated with artificial optical radiations were more stringent than needed. Using the most recent MPE limits for artificial optical radiation this piece of work was focused on the investigation of the level of visible light attenuation needed by automatic welding filters in case of switching failure. Results from the comparison of different exposure standards were employed in investigating the need of Vis/IR and blue light transmittance requirement for automatic welding filters. Real and arbitrary spectra were taken into consideration for the worst and best case scenarios of artificial optical radiations. An excel worksheet developed during the execution of this project took into consideration the exposure from different light sources and the precision of the spectrometer used in measuring the transmittances of a welding filter. The worksheet was developed and tested with known product properties to investigate the validity of its formulation. The conclusion drawn from this project was that attenuation in the light state will be needed for products with the darkest state shade 11 or higher. Also shown is that current welding filter protects the eye well enough even in the case of switching failure.
Resumo:
Denna rapport är en svensk sammanfattning av licentiatavhandlingen med titeln "Simple Question, Complex Answer. Pathways towards a 50% Decrease in Building Energy Use", som publicerades vid Uppsala Universitet i februari 2014. I denna rapport har jag samman-ställt det som jag anser vara de viktigaste resultaten ur ett länsperspektiv och rapporten riktar sig därför i första hand mot aktörer inom byggnadssektorn i Dalarna. Mer omfattande bild-material, diagram, tabeller och hänvisningar till källmaterial återfinns för den intresserade i licentiatavhandlingen. Min förhoppning är att denna sammanfattning kan ligga till grund för diskussioner och beslut om framtiden för Dalarnas småhusbestånd.