910 resultados para CORONARY-ARTERY
Resumo:
AIMS The genetic polymorphism of apolipoprotein E (APOE) has been suggested to modify the effect of smoking on the development of coronary artery disease (CAD) in apparently healthy persons. The interaction of these factors in persons undergoing coronary angiography is not known. METHODS AND RESULTS We analysed the association between the APOE-genotype, smoking, angiographic CAD, and mortality in 3263 participants of the LUdwigshafen RIsk and Cardiovascular Health study. APOE-genotypes were associated with CAD [ε22 or ε23: odds ratio (OR) 0.56, 95% confidence interval (CI) 0.43-0.71; ε24 or ε34 or ε44: OR 1.10, 95% CI 0.89-1.37 compared with ε33] and moderately with cardiovascular mortality [ε22 or ε23: hazard ratio (HR) 0.71, 95% CI 0.51-0.99; ε33: HR 0.92, 95% CI 0.75-1.14 compared with ε24 or ε34 or ε44]. HRs for total mortality were 1.39 (95% CI 0.39-0.1.67), 2.29 (95% CI 1.85-2.83), 2.07 (95% CI 1.64-2.62), and 2.95 (95% CI 2.10-4.17) in ex-smokers, current smokers, current smokers without, or current smokers with one ε4 allele, respectively, compared with never-smokers. Carrying ε4 increased mortality in current, but not in ex-smokers (HR 1.66, 95% CI 1.04-2.64 for interaction). These findings applied to cardiovascular mortality, were robust against adjustment for cardiovascular risk factors, and consistent across subgroups. No interaction of smoking and ε4 was seen regarding non-cardiovascular mortality. Smokers with ε4 had reduced average low-density lipoprotein (LDL) diameters, elevated oxidized LDL, and lipoprotein-associated phospholipase A2. CONCLUSION In persons undergoing coronary angiography, there is a significant interaction between APOE-genotype and smoking. The presence of the ε4 allele in current smokers increases cardiovascular and all-cause mortality.
Resumo:
Previous analyses of aortic displacement and distension using computed tomography angiography (CTA) were performed on double-oblique multi-planar reformations and did not consider through-plane motion. The aim of this study was to overcome this limitation by using a novel computational approach for the assessment of thoracic aortic displacement and distension in their true four-dimensional extent. Vessel segmentation with landmark tracking was executed on CTA of 24 patients without evidence of aortic disease. Distension magnitudes and maximum displacement vectors (MDV) including their direction were analyzed at 5 aortic locations: left coronary artery (COR), mid-ascending aorta (ASC), brachiocephalic trunk (BCT), left subclavian artery (LSA), descending aorta (DES). Distension was highest for COR (2.3 ± 1.2 mm) and BCT (1.7 ± 1.1 mm) compared with ASC, LSA, and DES (p < 0.005). MDV decreased from COR to LSA (p < 0.005) and was highest for COR (6.2 ± 2.0 mm) and ASC (3.8 ± 1.9 mm). Displacement was directed towards left and anterior at COR and ASC. Craniocaudal displacement at COR and ASC was 1.3 ± 0.8 and 0.3 ± 0.3 mm. At BCT, LSA, and DES no predominant displacement direction was observable. Vessel displacement and wall distension are highest in the ascending aorta, and ascending aortic displacement is primarily directed towards left and anterior. Craniocaudal displacement remains low even close to the left cardiac ventricle.
Resumo:
BACKGROUND Copper and its main transport protein ceruloplasmin have been suggested to promote the development of atherosclerosis. Most of the data come from experimental and animal model studies. Copper and mortality have not been simultaneously evaluated in patients undergoing coronary angiography. METHODS AND RESULTS We examined whether serum copper and ceruloplasmin concentrations are associated with angiographic coronary artery disease (CAD) and mortality from all causes and cardiovascular causes in 3253 participants of the Ludwigshafen Risk and Cardiovascular Health Study. Age and sex-adjusted hazard ratios (HR) for death from any cause were 2.23 (95% CI, 1.85-2.68) for copper and 2.63 (95% CI, 2.17-3.20) for ceruloplasmin when we compared the highest with the lowest quartiles. Corresponding hazard ratios (HR) for death from cardiovascular causes were 2.58 (95% CI, 2.05-3.25) and 3.02 (95% CI, 2.36-3.86), respectively. Further adjustments for various risk factors and clinical variables considerably attenuated these associations, which, however, were still statistically significant and the results remained consistent across subgroups. CONCLUSIONS The elevated concentrations of both copper and ceruloplasmin are independently associated with increased risk of mortality from all causes and from cardiovascular causes.
Resumo:
In the general population, HDL cholesterol (HDL-C) is associated with reduced cardiovascular events. However, recent experimental data suggest that the vascular effects of HDL can be heterogeneous. We examined the association of HDL-C with all-cause and cardiovascular mortality in the Ludwigshafen Risk and Cardiovascular Health study comprising 3307 patients undergoing coronary angiography. Patients were followed for a median of 9.9 years. Estimated GFR (eGFR) was calculated using the Chronic Kidney Disease Epidemiology Collaboration eGFR creatinine-cystatin C (eGFRcreat-cys) equation. The effect of increasing HDL-C serum levels was assessed using Cox proportional hazard models. In participants with normal kidney function (eGFR>90 ml/min per 1.73 m(2)), higher HDL-C was associated with reduced risk of all-cause and cardiovascular mortality and coronary artery disease severity (hazard ratio [HR], 0.51, 95% confidence interval [95% CI], 0.26-0.92 [P=0.03]; HR, 0.30, 95% CI, 0.13-0.73 [P=0.01]). Conversely, in patients with mild (eGFR=60-89 ml/min per 1.73 m(2)) and more advanced reduced kidney function (eGFR<60 ml/min per 1.73 m(2)), higher HDL-C did not associate with lower risk for mortality (eGFR=60-89 ml/min per 1.73 m(2): HR, 0.68, 95% CI, 0.45-1.04 [P=0.07]; HR, 0.84, 95% CI, 0.50-1.40 [P=0.50]; eGFR<60 ml/min per 1.73 m(2): HR, 1.18, 95% CI, 0.60-1.81 [P=0.88]; HR, 0.82, 95% CI, 0.40-1.69 [P=0.60]). Moreover, Cox regression analyses revealed interaction between HDL-C and eGFR in predicting all-cause and cardiovascular mortality (P=0.04 and P=0.02, respectively). We confirmed a lack of association between higher HDL-C and lower mortality in an independent cohort of patients with definite CKD (P=0.63). In summary, higher HDL-C levels did not associate with reduced mortality risk and coronary artery disease severity in patients with reduced kidney function. Indeed, abnormal HDL function might confound the outcome of HDL-targeted therapies in these patients.
Resumo:
BACKGROUND
Renal impairment (RI) is associated with impaired prognosis in patients with coronary artery disease. Clinical and angiographic outcomes of patients undergoing percutaneous coronary intervention (PCI) with the use of drug-eluting stents (DES) in this patient population are not well established.
METHODS
We pooled individual data for 5,011 patients from 3 trials with the exclusive and unrestricted use of DES (SIRTAX - N = 1,012, LEADERS - N = 1,707, RESOLUTE AC - N = 2,292). Angiographic follow-up was available for 1,544 lesions. Outcomes through 2 years were stratified according to glomerular filtration rate (normal renal function: GFR≥90 ml/min; mild RI: 90
Resumo:
BACKGROUND: Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. METHODS AND RESULTS: We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. CONCLUSION: Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease.
Resumo:
BACKGROUND Assessment of endothelial function of the microvasculature by peripheral arterial tonometry (EndoPAT(®)) has gained increasing popularity in patients with cardiovascular risk factors. Only limited knowledge about its reproducibility in patients with coronary artery disease (CAD) is available. We therefore aimed to quantify reproducibility of EndoPAT(®) parameters in patients with stable CAD. DESIGN EndoPAT(®) measurements were performed repeatedly in 78 male patients (age 66 ± 8 years) with CAD on stable medication. We calculated overall mean, standard deviation (SD), coefficient of variation (CV) and intraclass correlation coefficient (ICC) of the following parameters: reactive hyperemic index (RHI), PAT ratio of the postocclusion period 90-150 s as used for calculation of the RHI (PAT ratio90-150 s) and 90-120 s (PAT ratio90-120 s) as used for the often employed Framingham RHI (F-RHI), as well as PAT ratio of the peak hyperemic response (PAT ratiopeak response). Additionally, least significant changes (LSC) for individual subjects and minimum sample sizes for parallel and cross-over design studies were calculated. RESULTS Mean RHI was 1·84 (SD 0·36). For RHI, PAT ratio90-150 s , PAT ratio90-120 s , and PAT ratiopeak response the CVs were 17·0%, 25·4%, 26·1%, and 25·0%, respectively. The ICCs were 0·45, 0·49, 0·48 and 0·51, respectively, and LSC for RHI was 47·2%. CONCLUSIONS CV of RHI in our population was moderate; however, we consider this precision insufficient to monitor changes in individual patients, as they would need to exceed 47% to show a significant change. Further, the poor ICCs reflect the difficulty of detecting treatment effects in homogenous populations, such as patients with stable CAD.
Resumo:
In this 6-week prospective, randomized, placebo-controlled and double-blind study, we investigated the effects of a natural herbal remedy based on a recipe from Tibet (Padma® 28), on microvascular endothelial function, heart rate variability and biomarkers of inflammation, clotting and coagulation in 80 coronary artery disease (CAD) patients (age 66 ± 8 years) on guideline-based medication for secondary prevention. We found no significant effects of Padma 28 and conclude that the addition of Padma 28 to guideline-based secondary prevention treatment of CAD did not lead to significant effects on important surrogate markers in elderly male CAD patients.
Resumo:
An exponential increase in the use of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis has been witnessed over the recent years. The current article reviews different areas of uncertainty related to patient selection. The use and limitations of risk scores are addressed, followed by an extensive discussion on the value of three-dimensional imaging for prosthesis sizing and the assessment of complex valve anatomy such as degenerated bicuspid valves. The uncertainty about valvular stenosis severity in patients with a mismatch between the transvalvular gradient and the aortic valve area, and how integrated use of echocardiography and computed tomographic imaging may help, is also addressed. Finally, patients referred for TAVI may have concomitant mitral regurgitation and/or coronary artery disease and the management of these patients is discussed.
Resumo:
BACKGROUND Drug eluting stents for the treatment of small vessel coronary artery disease have traditionally yielded inferior clinical outcomes compared to the use of DES in large vessels. The benefit of the second-generation Resolute zotarolimus-eluting stent (R-ZES) in small vessels was examined. METHODS Two-year clinical outcomes from five combined R-ZES studies were compared between patients with small (reference vessel diameter [RVD] ≤2.5 mm; n = 1,956) and large (RVD >2.5 mm; n = 3174) vessels. RESULTS Despite a higher incidence of comorbidities in the small vessel group, there was no significant difference in target lesion failure (TLF) (10.1% vs. 8.7%; P = 0.54) at 2 years. When the subgroup of patients with diabetes was examined (n = 1,553) there was no significant difference in 2-year TLF in small compared to large vessels (11.2% vs. 11.1%; P = 0.17). Similarly, within the small vessel cohort, no significant difference was seen regarding TLF at 2 years between people with and without diabetes (11.2% vs 9.6%; P = 0.28). CONCLUSION When used for the treatment of small vessels, the R-ZES appears to provide acceptable clinical results at 2 years when compared to its performance in large vessels.
Resumo:
BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.
Resumo:
BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.
Resumo:
This article reviews technical aspects and the current status of novel cardiovascular magnetic resonance (CMR) approaches to assessing myocardial perfusion, specifically oxygenation-sensitive magnetic resonance imaging, comparing their diagnostic targets and clinical role with those of other imaging approaches. The paper includes discussions of relevant pathophysiological aspects of myocardial ischemia and the clinical context of revascularization in patients with suspected or known coronary artery disease. Research using oxygenation-sensitive CMR may play an important role for a better understanding of the interplay of coronary artery stenosis, blood flow reduction, and their impact on actual myocardial ischemia.
Resumo:
The resting ECG is a safe, low cost and widely available in the clinical investigation of several cardiac symptoms. However, there is controversy regarding the use as a screening tool or routine cardiovascular (CV) risk assessment test among healthy asymptomatic adults. Two recent studies reported that ECG adds supplemental information in the estimation of coronary artery disease (CAD) risk in asymptomatic patients, especially in those with intermediate risk. However, we currently need more data on the impact of ECG on the prevention of clinical CV outcomes, especially in a randomized clinical trial, and on additional costs of testing and treatment. For the time being, routine ECG testing is not recommended for the prevention of CV events among healthy asymptomatic adults.