Ten year clinical follow-up after Sirolimus-eluting stent implantation
Data(s) |
01/06/2014
|
---|---|
Resumo |
BACKGROUND: Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. METHODS AND RESULTS: We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. CONCLUSION: Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/59142/1/Sirolimus_10Y_AHJ.pdf Palhais, Nuno; Arroyo, Diego Andoni; Lehmann, Sonja; Togni, Mario; Kaufmann, Urs; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Cook, Stéphane (2014). Ten year clinical follow-up after Sirolimus-eluting stent implantation. American Heart Journal, 167(6), pp. 893-899. Elsevier 10.1016/j.ahj.2013.12.013 <http://dx.doi.org/10.1016/j.ahj.2013.12.013> doi:10.7892/boris.59142 info:doi:10.1016/j.ahj.2013.12.013 urn:issn:0002-8703 |
Idioma(s) |
eng |
Publicador |
Elsevier |
Relação |
http://boris.unibe.ch/59142/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Palhais, Nuno; Arroyo, Diego Andoni; Lehmann, Sonja; Togni, Mario; Kaufmann, Urs; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Cook, Stéphane (2014). Ten year clinical follow-up after Sirolimus-eluting stent implantation. American Heart Journal, 167(6), pp. 893-899. Elsevier 10.1016/j.ahj.2013.12.013 <http://dx.doi.org/10.1016/j.ahj.2013.12.013> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |