948 resultados para Bladder outlet obstruction


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of Pt/Mg-Al-O catalysts with different Mg/Al atomic ratios were prepared. The NOx storage capacities of these catalysts were measured by isothermal storage at 350 degreesC. It was found that the NOx storage capacity increased with increasing Mg/Al atomic ratios. The catalytic behaviors of Pt/Mg-Al-O and Pt/MgO were studied with storage-reduction cycles at 400 degreesC. Under oxidizing conditions, NOx concentration in the outlet gas gradually increased with time, which indicated the catalysts could store NOx effectively. After a switch from oxidizing conditions to reducing conditions, NOx desorption peak emerged immediately due to the incomplete reduction of stored NOx, which lowered the total NOx conversion. With increasing Mg/Al atomic ratio in the catalysts, NOx conversion increases. Pt/MgO has the highest NOx conversion because of its best activity in the reduction of NOx by C3H6. It seems that with an increasing amount of MgO in the catalysts, the self-poisoning of Pt-sites by adsorbed species during the reaction of NOx with C3H6 may be inhibited effectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dynamic flow profiles and separation performances in conically shaped preparative liquid chromatographic columns (inlet i.d. larger than outlet i.d.) with three different angles (7, 10 and 15degrees) were studied and compared with cylindrical column of the same length and internal volume. The shapes of dynamic flow profiles were studied by on-column visualization method. The transparent chromatographic columns made of polymethyl methacrylate (PMMA), packed with C-18 bonded silica, were immerged into a cubic pool filled with glycerol to eliminate the cylindrical and conical lens effect. The flow profiles of colored iodine solution in the columns were observed clearly using cyclohexane as mobile phase since the refractive indices of C-18, column wall and the mobile phase are very close. In the conical column of 15degrees (20-7 mm i.d.) the mobile phase in the central region migrated slower than in wall region as it moved toward the column outlet, while in the conical column of 7degrees (17-11 mm i.d.) the mobile phase in the central region migrated faster than in wall region just like in cylindrical column. We found that a plug-like flow profile was generated in the conical column of 10degrees (18-9 mm i.d.) during the whole migration process. A carmine and brilliant blue mixture was used as a probe to test the separation ability of the columns. The resolutions of the two compounds on the conical column of 7, 10, 15degrees and on the cylindrical column were 0.6, 1.57, 1.29 and 0.8, respectively. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dynamic flow profiles and column efficiencies in conically shaped semi-preparative liquid chromatographic columns (inlet ID larger than outlet ID) with two different conical angles (7degrees and 15degrees) were studied. The dynamic flow profiles were studied by an on-column visualization method. Conical columns were compared with cylindrical column of the same length and internal volume. The results showed that the flow profile of a sample band in the conical column of 7degrees (50 mm x 17 mm --> 11 mm ID) was parabolic in shape. The sample band migrated slower in the wall region than in the central region, as in the cylindrical column (50 mm x 14 mm ID). However, the sample band in the conical column of 15degrees (50 mm x 20 mm --> 7 mm ID) migrated slower in the central region than in the wall region, resulting in a reverse parabolic flow profile, in contrast to that in cylindrical column. This indicated that a flat flow profile might be realized in a conical column with a conical angle between 7degrees and 15degrees. The conical column of 15degrees had the highest column efficiency among the three columns under the same conditions. Compared with the cylindrical column packed with identical packing material, the conical column of 15degrees had 22%-45% higher column efficiency and 11%-27% higher peak height.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文进行了一系列水槽试验 ,研究不同长度的侵蚀细沟在坡度及入流量影响下的浅水水流水力学特性、侵蚀量及细沟的形态特征 .所采用的土壤材料为砂壤土 ,试验使用四种入流流量 ,四种坡度 ,四种细沟长度 .记录水流速度、沟宽及径流中的泥沙含量 ,并用多元回归方法分析了它们与坡度、入流量或它们的交互项之间的关系 .提出了一种数学模型来描述试验中沟宽的周期性形态变化 .提出了通过试验得出的不同细沟长度的产沙量来确定水流输沙能力的方法 ,并得出出测定输沙能力的采样长度为 2~ 4m ,通过对细沟形态变化分析进一步说明了所确定的水流输沙能力采样长度的正确性

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new setup to couple capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection is described in which the electrical connection of CE is achieved through a porous section at a distance of 7 mm from the CE capillary outlet. Because the porous capillary wall allowed the CE current to pass through and there was no electric field gradient beyond that section, the influence of CE high-voltage field on the ECL procedure was eliminated. The porous section formed by etching the capillary with hydrofluoric acid after only one side of the circumference of 2-3 mm of polyimide coating of the capillary was removed, while keeping the polyimide coating on the other part to protect the capillary from HF etching makes the capillary joint much more robust since only a part of the circumference of it is etched. A standard three-electrode configuration was used in experiments with Pt wire as a counter electrode, Ag/AgCl as a reference electrode, and a 300-mum diameter Pt disk as a working electrode. Compared with CE-ECL conventional decoupler designs, the present setup with a porous joint has no added dead volume created.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An on-chip disk electrode based on sol-gel-derived carbon composite material could be easily and reproducibly fabricated. Unlike other carbon-based electrodes reported previously, this detector is rigid, convenient to fabricate, and amenable to chemical modifications. Based on the stable and reproducible characters of this detector, a copper particle-modified detector was developed for the detection of carbohydrates which extends the application of the carbon-based electrode. In our experiments, the performance of the new integrated detector for rapid on-chip measurement of epinephrine and glucose was illustrated. Experimental procedures including the fabrication of this detector, the configuration of separation channel outlet and electrode verge, and the performance characteristics of this new electrochemical detector were investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CE/tris(2,2-bipyridyl) ruthenium(ll) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL), CEECL, with an ionic liquid (IL) detection system was established for the determination of bioactive constituents in Chinese traditional medicine opium poppy which contain large amounts of coexistent substances. A minimal sample pretreatment which involves a one-step extraction approach avoids both sample loss and environmental pollution. As the nearby hydroxyl groups in some alkaloid such as morphine may react with borate to form complexes and IL, as a high-conductivity additive in running buffer, could cause an enhanced field-amplified effect of electrokinetic injection. Running buffer containing 25 mM borax-8 mM 1-ethyl-3-methylimidazolium tetrafluoroborate (EMImBF(4)) IL (pH 9.18) was used which resulted in significant changes in separation selectivity and obvious enhancement in ECL intensities for those alkaloids with similar structures. Sensitive detection could be achieved when the distance between the Pt working electrode and the outlet of separation capillary was set at 150 mu m and the stainless steel cannula was fixed approximately 1 cm away from the outlet of the capillary. Quantitative analysis of four alkaloids was achieved at a detection voltage of 1.2 V and a separation voltage of 15 kV in less than 7 min.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CE with electrochemiluminescence, (ECL) detection technique was successfully applied for the chiral separation of a kind of class IA antiarrhythmic racemic drug. To the best of our knowledge, this is the first report of ECL detection used in chiral CE. To get better detection sensitivity and good enantioresolution at the same time, the conditions of capillary inlet and outlet buffer were systematically optimized. Unlike the traditional chiral separation method, the buffers we used in the capillary inlet and outlet differed from each other in terms of buffer pH, ionic strength, type of BGE as well as buffer composition. Under the optimum conditions, baseline enantioseparation and highly sensitive detection of the enantiomers were achieved. Wide linear relationship of each enantiomer was achieved in the range of 5 x 10(-7) to 2 x 10(-5) mol/L with relative coefficients of 0.996 and 0.997, respectively. The detection limits were estimated to be 8 x 10(-8) and 1.0 X 10(-7) mol/L (S/N = 3) for the enantiomers, respectively. In addition, a successful application of this new method to the chiral separation of the racemic drug in spiked plasma samples confirmed the validity and applicability of the chiral CE-ECL method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new flow field was designed to search flow fields fitting polymer electrolyte membrane fuel cells (PEMFCs) better due its extensible. There are many independent inlets and outlets in the new flow field. The new flow field we named NINO can extend to be more general when pressures at the inlet and outlet vary and some usual flow fields will be obtained. A new mathematical model whose view angle is obverse is used to describe the flow field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

capillary electrophoresis (CE) is characterized. A 300 mum diameter Pt working electrode was used to directly couple with a 75 mum inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy)(3)(2+) showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy)(3)(2+) in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 mum capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 20-260 mum. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 mum capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 X 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 X 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-1) mol/L.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The impact of the Huanghe (Yellow) River outflows on its estuary was investigated with river gauging and shipboard hydrographic observations. The river flux has been decreasing dramatically; the discharges of water and sediment in the 1990s dropped to 27.4% and 31.9% of those in the 1950s, respectively, resulting in frequent and lengthy events of downstream channel dry-up since the 1970s. There were accumulatively 897 zero-flow days during the 1990s in the river course below the Lijin Hydrological Station, 100 km upstream from the river mouth, which is 82.4% of that in 1972. As freshwater input decreases, river-borne nutrients to the estuarine increased significantly. Concentration of dissolved inorganic nitrogen (DIN) in the 1990s was four times of that in 1950s. Changes in amount and content of the riverine inputs have greatly affected the estuarine ecosystem. Over the past several decades, sea surface temperature and salinity in the estuary and its adjacent waters increased and their distribution pattern altered in response to the reduction of freshwater inflow. The distribution of and seasonal succession in nutrient concentrations in the surface layer have also changed with a shift of river outlet and the decrease in riverine nutrient loads. Furthermore, deterioration of estuarine ecosystem by less river input has decreased primary productivity in the deltaic region waters, and in turn depressed the fishery. (C) 2008 Published by Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

海水经济鱼类的养殖在我国已经形成第四次海水养殖浪潮,经济效益显著,有力地推动了我国海水养殖的产业结构调整和可持续发展。然而在海水养殖发展过程中也存在着诸多问题,尤其是早期发育阶段的高死亡率,严重制约了我国海水养殖产业的稳定和健康发展。 海水鱼类养殖的关键为高质量,高存活率苗种的生产和培育,由于鱼类种类繁多,生物多样性丰富,对应实际的繁育技术,尤其是新品种的开发,必须要做出相应的调整。这就要求我们必须对每一种鱼类早期发育有所了解,并将形态和组织上的数据用于指导生产。 本文通过显微观察和组织学研究,主要描述和研究了我国北方三种重要的海水经济鱼类(条斑星鲽、杂交鲆、条石鲷)的早期发育生物学,并结合实际生产进一步阐明关键期的产生原因,机理以及采用相应的对策。具体结果如下: 1.条斑星鲽:作为冷温性鲆鲽鱼类,条斑星鲽早期发育过程的特征主要有: ① 条斑星鲽受精卵无油球,卵子呈半浮性;不同步卵裂现象提前,发生在第三次卵裂;卵裂期裂球大小差异大。孵化过程较长,在水温8 ± 0.3℃,盐度33的条件下,经9 d孵化。条斑星鲽胚胎发育的不同时期对温度的敏感性不同,其中原肠期对温度比较敏感。 ②在8-10℃,盐度33的条件下,8-9 dph开口摄食。且开口时,其吻前端出现有一点状黑褐色素,构成了条斑星鲽仔鱼“开口期”的重要标志。卵黄囊于消失。在后期仔鱼末期,背鳍和臀鳍上形成特有的黑褐色条斑带。 ③杯状细胞首先出现在咽腔后部和食道前段,胃腺和幽门盲囊出现于29 dph,变态期始于30dph。在条斑星鲽早期发育过程中,观察到其直肠粘膜层细胞质出现大量嗜伊红颗粒,为仔鱼肠道上皮吸收的蛋白质。 ④首先淋巴化的免疫器官是头肾,然后是胸腺和脾脏,这与大部分硬骨鱼类不同。条斑星鲽除头肾和脾脏外,胸腺实质也形成MMCs。其中以脾脏形成MMCs最为丰富,形态多样。 2. 杂交鲆:为同属的牙鲆和夏鲆间的远缘杂交种,其发育过程的特点为: ① 在温度为15.4~16.0℃,杂交鲆胚胎从受精到孵化所需的时间为76 h左右,胚孔关闭前期,胚胎先出现视囊及克氏囊,而后形成体节。孵出前胚体在卵膜内环绕不到1周。 ② 孵化后消失。杂交鲆群体变态间隔长(34-60 dph),且变态高峰期出现的冠状幼鳍不明显(与母本牙鲆相比),数量为7-8根。 ③组织学观察发现,其消化系统中胃腺出现较晚,且胃腺发育过程缓慢(与母本牙鲆相比)。甲状腺滤泡增生不明显,颜色较浅,数量较少。杂交鲆在早期发育过程中,并没有出现鳔原基。 3. 条石鲷作为岩礁性的暖水性鱼类,早期发育过程也较为特殊,包括外形以及内部的器官结构。主要特点有: ① 受精卵:受精卵卵黄上具有龟裂结构,为鱼卵的分类特征之一。 ② 初孵仔鱼:初孵仔鱼背鳍膜上的黑色素,从体背面向背鳍膜边缘移动,到3dph仔鱼基本消失,此为本种仔鱼发育所特有的特点。 ③ 后期仔鱼和稚鱼:肠道肌肉层加厚明显,仔稚鱼胃肠排空率急剧上升,死亡率增加,通过改善常规的投饵方式部分解决了这个死亡高峰的问题。在幼鱼初期,牙齿融合为骨喙,为石鲷科鱼类的特征。 ④胸腺上皮分泌细胞:类似的现象同样在虹鳟鱼中发现,但是虹鳟鱼胸腺上皮分泌细胞不如条石鲷的丰富,同样也不如条石鲷的排列整齐,而是零星分布在胸腺上皮与咽腔接触的表面。除了正常的造血器官—脾脏和头肾外,肝脏、胰腺和鳔等多种组织等也出现MMCs,此现象在硬骨鱼类不多见,一般发生在软骨鱼类。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oil and scientific groups have been focusing on the 3D wave equation prestack depth migration since it can solve the complex problems of the geologic structure accurately and maintain the wave information, which is propitious to lithology imaging. The symplectic method was brought up by Feng Kang firstly in 1984 and became the hotspot of numerical computation study. It will be widely applied in many scientific field of necessity because of its great virtue in scientific sense. This paper combines the Symplectic method and the 3-D wave equation prestack depth migration to bring up an effectual numerical computation method of wave field extrapolatation technique under the scientific background mentioned above. At the base of deep analysis of computation method and the performance of PC cluster, a seismic prestack depth migration flow considering the virtue of both seismic migration method and Pc cluster has formatted. The software, named 3D Wave Equation Prestack Depth Migration of Symplectic Method, which is based on the flow, has been enrolled in the National Bureau of Copyright (No. 0013767). Dagang and Daqing Oil Field have now put it into use in the field data processing. In this paper, the one way wave equation operator is decompounded into a phase shift operator and a time shift operator and the correct item with high rank Symplectic method when approaching E exponent. After reviewing eliminating alias frequency of operator, computing the maximum angle of migration and the imaging condition, we present the test result of impulse response of the Symplectic method. Taking the imaging results of the SEG/EAGE salt and overthrust models for example and seeing about the imaging ability with complex geologic structure of our software system, the paper has discussed the effect of the selection of imaging parameters and the effectuation on the migration result of the seismic wavelet and compared the 2-D and 3-D prestack depth migration result of the salt mode. We also present the test result of impulse response with the overthrust model. The imaging result of the two international models indicates that the Symplectic method of 3-D prestack depth migration accommodates great transversal velocity variation and complex geologic structure. The huge computing cost is the key obstruction that 3-D prestack depth migration wave equation cannot be adopted by oil industry. After deep analysis of prestack depth migration flow and the character of PC cluster ,the paper put forward :i)parallel algorithms in shot and frequency domain of the common shot gather 3-D wave equation prestack migration; ii)the optimized setting scheme of breakpoint in field data processing; iii)dynamic and static load balance among the nodes of the PC cluster in the 3-D prestack depth migration. It has been proven that computation periods of the 3-D prestack depth migration imaging are greatly shortened given that adopting the computing method mentioned in the paper. In addition,considering the 3-D wave equation prestack depth migration flow in complex medium and examples of the field data processing, the paper put the emphasis on: i)seismic data relative preprocessing, ii) 2.5D prestack depth migration velocity analysis, iii)3D prestack depth migration. The result of field data processing shows satisfied application ability of the flow put forward in the paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This year, as the finale to the Artificial Intelligence Laboratory's annual Winter Olympics, the Lab staged an AI Fair ??night devoted to displaying the wide variety of talents and interests within the laboratory. The Fair provided an outlet for creativity and fun in a carnival-like atmosphere. Students organized events from robot boat races to face-recognition vision contests. Research groups came together to make posters and booths explaining their work. The robots rolled down out of the labs, networks were turned over to aerial combat computer games and walls were decorated with posters of zany ideas for the future. Everyone pitched in, and this photograph album is a pictorial account of the fun that night at the AI Fair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In an attempt to effectively integrate catalytic partial oxidation (CPO) and steam reforming (SR) reactions on the same catalyst, autothermal reforming (ATR) of n-octane was addressed based on thermodynamic analysis and carried out on a non-pyrophoric catalyst 0.3 wt.% Ru/K2O-CeO2/gamma-Al2O3. The ATR of n-octane was more efficient at the molar ratio Of O-2/C 0.35-0.45 and H2O/C 1.6-2.2 (independent parameters), respectively, and reforming temperature of 750-800 degrees C (dependent parameter). Among the sophisticated reaction network, the main reaction thread was deducted as: long-chain hydrocarbon -> CH4, short-chain hydrocarbon -> CO2, CO and H-2 formation by steam reforming, although the parallel CPO, decomposition and reverse water gas shift reaction took place on the same catalyst. Low temperature and high steam partial pressure had more positive effect on CH4 SR to produce CO2 other than CO. This was verified by the tendency of the outlet reformate to the equilibrium at different operation conditions. Furthermore, the loss of active components and the formation of stable but less active components in the catalyst in the harsh ATR atmosphere firstly make the CO inhibition capability suffer, then eventually aggravated the ATR performance, which was verified by the characterizations of X-ray fluorescence, BET specific surface areas and temperature programmed reduction. (c) 2005 Elsevier B.V. All rights reserved.