962 resultados para 3D Computer Graphics
Resumo:
Glutaric aciduria type I (glutaryl-CoA dehydrogenase deficiency) is an inborn error of metabolism that usually manifests in infancy by an acute encephalopathic crisis and often results in permanent motor handicap. Biochemical hallmarks of this disease are elevated levels of glutarate and 3-hydroxyglutarate in blood and urine. The neuropathology of this disease is still poorly understood, as low lysine diet and carnitine supplementation do not always prevent brain damage, even in early-treated patients. We used a 3D in vitro model of rat organotypic brain cell cultures in aggregates to mimic glutaric aciduria type I by repeated administration of 1 mM glutarate or 3-hydroxyglutarate at two time points representing different developmental stages. Both metabolites were deleterious for the developing brain cells, with 3-hydroxyglutarate being the most toxic metabolite in our model. Astrocytes were the cells most strongly affected by metabolite exposure. In culture medium, we observed an up to 11-fold increase of ammonium in the culture medium with a concomitant decrease of glutamine. We further observed an increase in lactate and a concomitant decrease in glucose. Exposure to 3-hydroxyglutarate led to a significantly increased cell death rate. Thus, we propose a three step model for brain damage in glutaric aciduria type I: (i) 3-OHGA causes the death of astrocytes, (ii) deficiency of the astrocytic enzyme glutamine synthetase leads to intracerebral ammonium accumulation, and (iii) high ammonium triggers secondary death of other brain cells. These unexpected findings need to be further investigated and verified in vivo. They suggest that intracerebral ammonium accumulation might be an important target for the development of more effective treatment strategies to prevent brain damage in patients with glutaric aciduria type I.
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
Åknes is an active complex large rockslide of approximately 30?40 Mm3 located within the Proterozoic gneisses of western Norway. The observed surface displacements indicate that this rockslide is divided into several blocks moving in different directions at velocities of between 3 and 10 cm year?1. Because of regional safety issues and economic interests this rockslide has been extensively monitored since 2004. The understanding of the deformation mechanism is crucial for the implementation of a viable monitoring system. Detailed field investigations and the analysis of a digital elevation model (DEM) indicate that the movements and the block geometry are controlled by the main schistosity (S1) in gneisses, folds, joints and regional faults. Such complex slope deformations use pre-existing structures, but also result in new failure surfaces and deformation zones, like preferential rupture in fold-hinge zones. Our interpretation provides a consistent conceptual three-dimensional (3D) model for the movements measured by various methods that is crucial for numerical stability modelling. In addition, this reinterpretation of the morphology confirms that in the past several rockslides occurred from the Åknes slope. They may be related to scars propagating along the vertical foliation in folds hinges. Finally, a model of the evolution of the Åknes slope is presented.
Resumo:
L’objectiu del projecte consisteix en l’estudi, simulació i implantació d’un conjunt d’aplicacions que permeten tenir un control sobre possibles problemes que puguin succeir a la nostra xarxa. Aquest projecte és la solució als problemes de detecció d’errors en el funcionament de les infraestructures de networking de les que disposen els nostres clients.
Resumo:
La industria de los videojuegos crece exponencialmente y está ya superando a otras industrias punteras del ocio. En este proyecto, nos hemos planteado la realización de un videojuego con visualización en el espacio real 3D. Para la realización del videojuego se ha usado el siguiente software: Blender para diseñar los modelos 3D, C++ como lenguaje de programación para desarrollar el código y un conjunto de librerías básicas para desarrollar un videojuego llamadas Ogre3d (Motor Gráfico). La lógica del movimiento 3D y los choques entre las partículas del juego ha sido diseñada enteramente en este proyecto acorde con las necesidades del videojuego, y de forma compatible a los ficheros de Blender y a las librerías OGRE3D.
Resumo:
Aquesta memòria descriu el projecte de final de carrera anomenat "Disseny d’un Battle Chess 3D (2)", que tracta de la creació, modelat i animació de peces per a un joc d’escacs en 3 dimensions amb certes temàtiques, i que posteriorment s’integren amb el projecte "Disseny d’un Battle Chess 3D (1)" per a formar un joc interactiu d’escacs en un applet de Java. Es descriuen les eines utilitzades, les fases de creació, tècniques simbòliques, mètodes més emprats, proves sotmeses, limitacions, i finalment s’arriba una conclusió de treball aconseguit.
Resumo:
The CIPA programme is a collaborative project including two entomologists from France and seven South and Central America countries. Its objective is the development of an expert system for computer aided identification of phlebotomine sandflies from the Americas. It also includes the formation of data bases for bibliographic, taxonomic and biogeographic data. Participant consensus on taxonomic prerequisites, standardization in bibliographic data collections and selection of descriptive variables for the final programme has been established through continous communication among participants and annual meetings. The adopted check-list of American sandflies presented here includes 386 specific taxa, ordered into genera and 28 sub-genera or species groups.
Resumo:
Malonate, methylmalonate and propionate are potentially neurotoxic metabolites in branched-chain organic acidurias. Their effects were tested on cultured 3D rat brain cell aggregates, using dosages of 0.1, 1.0 and 10.0 mM with a short but intense (twice a day over 3 days) and a longer but less intense treatment (every 3 rdday over 9 days). CNS cell-specific immunohistochemical stainings allowed the follow-up of neurons (axons, phosphorylated medium-weight neurofilament), astrocytes (glial fibrillary acidic protein) and oligodendrocytes (myelin basic protein). Methylmalonate and malonate were quantified by tandem mass spectrometry. Tandem mass spectrometry analysis of harvested brain cell aggregates revealed clear intracellular accumulation of methylmalonate and malonate. In immunohistochemical stainings oligodendrocytes appeared the most affected brain cells. The MBP signal disappeared already at 0.1 mM treatment with each metabolite. Mature astrocytes were not affected by propionate, while immature astrocytes on intense treatment with propionate developed cell swelling. 1 mM methylmalonate induced cell swelling of both immature and mature astrocytes , while 1 mM malonate only affected mature astrocytes. Neurons were not affected by methylmalonate, but 10.0 mM malonate on less intense treatment and 0.1, 1.0 and 10.0 mM propionate on intense treatment affected axonal growth. Our study shows significant uptake and deleterious effects of these metabolites on brain cells, principally on astrocytes and oligodendrocytes. This may be explained by the absence of the pathway in glial cells, which thus are not able to degrade these metabolites. Further studies are ongoing to elucidate the underlying mechanisms of the observed neurotoxic effects.
Resumo:
El projecte "Laboratori Asssit per Ordinador Mitjançant Eines Ofimàtiques Convencionals" ha estat realitzat en la facultat de Física de la Universitat de Barcelona durant els anys 2007 i 2008 (projecte biennal). El principal objectiu d’aquest projecte és demostrar la possibilitat d’utilitzar les eines informàtiques més habituals en la realització d’experiències de laboratori assistit per ordinador (LAO). En particular, es proposa la utilització del Excel © juntament amb les seves macros (Visual Basic para Aplicacions, VBA) en pràctiques de laboratori d’assignatures en l’àrea de Física Aplicada. Excel és un full de càlcul molt conegut i usat tant per professors com pels estudiants. En aquest treball mostrem exemples concrets que abasten les diferents tècniques de control i adquisició de dades: programació del port sèrie (RS- 232) i paral·lel, i interfase GPIB. La implementació d’aquestes tècniques es realitza mitjançant macros VBA de Excel. La resta de programació de l’aplicació LAO, la representació gràfica i el tractament de les dades, es realitza de forma molt simple a partir del maneig habitual d’un full de càlcul. La realització del projecte ha demostrat la conveniència d’aquesta metodologia. Actualment pràcticament la totalitat de les pràctiques LAO de les quals és responsable el Departament de Física Aplicada utilitzen la programació a través del full de càlcul. La resposta dels estudiants ha estat molt positiva. La combinació de les característiques d’aquesta eina juntament amb la programació VBA té un enorme potencial i representa, probablement, una forma senzilla d’introduir tant a l’alumne com al professor en el món de la programació.
Resumo:
En la carrera del mundo de los videojuegos por alcanzar insospechables cotas de realismo con las que seguir sorprendiendo y enganchando al público, los motores de física se han convertido en la herramienta de presente y futuro. Atraídos por el auge de esta nueva tecnología, hemos lidiado con los motores referencia hoy día en el mercado, seleccionando luego uno de ellos e implementando un humilde videojuego de carreras como muestra de su potencial y de los conocimientos adquiridos.
Resumo:
Aquest projecte resol les fases inicials d'un altre projecte més gran que té com a objectiu la conversió automàtica de seqüències d'imatges a 3D. El projecte s'ha centrat en la reconstrucció calibrada de col·leccions d'imatges mitjançant la tècnica anomenada structure from motion. Aquesta tècnica forma part de l'àmbit de la visió per computador i s'utilitza per obtenir la posició i l'orientació de les diferents càmeres juntament amb una reconstrucció 3D de l'escena en forma de núvol de punts.
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.