982 resultados para 153-923


Relevância:

10.00% 10.00%

Publicador:

Resumo:

170 p.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ce3+ ions were introduced into the Er3+/Yb3+ -codoped TeO2-WO3-ZnO glasses, and the effect of Ce3+ on the emission properties at 1.5 mu m band and the upconversion luminescence of Er3+ in the glasses was investigated. With the increasing of Ce3+ concentration, the emission intensity of Er3+ at 1.5 mu m band increases firstly, and then decreases. The optimal doping concentration of Ce3+ is about 2.07 x 10(20)/cm(3). As for the Er3+ emission at 1.5-mu m band, the fluorescence lifetime decreases a little from 3.4ms to 3.0ms, while the full width at half maximum (FWHM) hardly changes with the increase of Cc 3+ concentration. Due to the effective cross relaxation between Ce3+ and Er3+ : Er3+ (I-4(11/2)) + Ce3+ (F-2(5/2)) -> Er3+ (I-4(13/2)) + Ce3+ (F-2(7/2)), the upconversion emission intensity of Er3+ is reduced greatly. But when Ce3+ -doping concentration is too high, the other cross relaxation between Ce3+ and Er3+ : Er3+ (4I(13/2)) + Ce3+ (F-2(5/2)) -> Er3+ (I-4(15/2)) + Ce3+ (F-2(7/2)) happens, which depopulates the I-4(13/2) level of Er3+ and results in the decrease of the emission intensity and fluorescence lifetime of Er3+ at 1.5 mu m band.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tm3+/Yb3+-codoped heavy metal oxide-halide glasses have been synthesized by conventional melting and quenching method. Structural properties were obtained based on the Raman spectra, indicating that halide ion has an important influence on the phonon density and maximum phonon energy of host glasses. Intense blue and weak red emissions centered at 477 and 650 nm, corresponding to the transitions (1)G(4) -> H-3(6) and (1)G(4) -> H-3(4), respectively, were observed at room temperature. The possible up-conversion mechanisms are discussed and estimated. With increasing halide content, the up-conversion luminescence intensity and blue luminescence lifetimes of Tm3+ ion increase notably. Our results show that with the substitution of halide ion for oxygen ion, the decrease of phonon density and maximum phonon energy of host glasses both contribute to the enhanced up-conversion emissions. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]Este trabajo tiene como objetivo satisfacer la demanda de energía del municipio de Abadín, situado en la provincia de Lugo, aprovechando los recursos eólicos de la zona. Para ello será necesario un análisis de la demanda total de la población y de las condiciones del viento en la zona. Después se elegirá el emplazamiento donde las condiciones de viento sean adecuadas para instalar el sistema eólico. Conocidos estos datos, se elegirá un aerogenerador y se calculará la potencia que proporciona en función de sus características. Por último, se concluirá si el sistema eólico diseñado cubre las necesidades energéticas del municipio o no.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-quality Nd:LuVO4 single crystal was successfully grown by Czochralski method. The assessment of the crystalline quality by the chemical etching method and Conoscope image was reported. The absorption spectra from 300 to 1000 nm and emission spectra from 960 to 1450 nm of Nd: LuVO4 were measured. Laser performance was achieved with Nd:LUVO4 crystal for the transition of F-4(3/2) -> I-4(11/2) (corresponding wavelength 1065.8 nm) in an actively Q-switched operation, and the average output power reached 5.42 W at a pulse repetition frequency (PRF) of 40 kHz under pump power of 18 W, giving an optical conversion efficiency of 30.1%. The pulse energy and peak power reached 138 mu J and 16.2 kW at PRF of 25 kHz under pump power of 14.2 W, and the pulse duration was 8.5 ns. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imagens de tomografia computadorizada (TC) permitem a visualização, sem distorções ou sobreposições, do complexo maxilo-facial, principalmente do osso alveolar. Estudos demonstraram boa reprodutibilidade e precisão da mensuração da altura da borda alveolar, todavia a influência da espessura óssea ainda é pouco descrita. Através da comparação com a mensuração direta, o objetivo deste estudo foi avaliar a precisão, reprodutibilidade e a influência da espessura óssea, na mensuração da altura da borda alveolar em imagens volumétricas e imagens bidimensionais multiplanares em TC de feixe cônico (TCFC) e em TC espiral (TCE). Utilizando 10 mandíbulas secas de humanos, 57 dentes anteriores foram tomografados em equipamentos iCAT (Imaging Science International, Hatfield, PA, EUA) e Brilliance 64 canais (Philips Eletronics, Eindhoven, Holanda), ambos utilizando voxels de 0,25 mm. Através de imagens volumétricas (3D) e imagens bidimensionais (2D) de cortes multiplanares, foi comparada a mensuração da altura da borda alveolar dessas imagens com a mensuração direta nas mandíbulas, feita por vestibular e lingual, por três avaliadores, com o auxílio de um paquímetro, totalizando 114 bordas alveolares medidas. Alta reprodutibilidade intra-avaliador (0,999 a 0,902) e interavaliador (0,998 e 0,868) foi observada através do índice de correlação intraclasse (ICC). Observou-se alta correlação entre a mensuração direta e indireta da altura da borda alveolar em imagens 2D, sendo r=0,923** e 0,916**, e em imagens 3D, com r=0,929** e 0,954*, em TCFC e TCE, respectivamente. Imagens 2D superestimam a altura da borda alveolar em 0,32 e 0,49 mm e imagens 3D em 0,34 e 0,30 mm, em TCFC e TCE respectivamente. Quando o osso alveolar apresenta espessura de no mínimo 0,6 mm a média da diferença entre medidas diretas e indiretas é de 0,16 e 0,28 mm em imagens 2D e de 0,12 e 0,03 mm em imagens 3D para TCFC e TCE respectivamente, sendo que 95% do limite de concordância varia de -0,46 a 0,79 mm e -0,32 a 0,88 mm em imagens 2D, e de -0,64 a 0,67 mm e -0,57 a 0,62 mm em imagens 3D, para TCFC e TCE respectivamente. Quando o osso alveolar é mais fino do que 0,6 mm a TC é imprecisa, pois 95% do limite de concordância variou de -1,74 a 5,42 mm e -1,64 a 5,42 mm em imagens 2D, e de -3,70 a 4,28 mm e -3,49 a 4,25 mm em imagens 3D, para TCFC e TCE respectivamente. Conclui-se que a mensuração da altura da borda alveolar através de imagens tomográficas apresenta alta reprodutibilidade, sendo que quando a borda alveolar apresenta pelo menos 0,6 mm, a precisão da mensuração é alta, todavia quando esta espessura é menor do que 0,6 mm a técnica é imprecisa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stranded whales in estuarine waters were identified in Côte d'Ivoire: the Spermwhale, Physeter catodon L. 1758 and the Finwhale, Balaenoptera physalus L. 1758.