993 resultados para rotary instrumentation
Resumo:
A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.
Resumo:
Coronary artery fistulae represent the most frequent congenital anomalies of the coronary arteries, but remain a relatively uncommon clinical problem. Moreover, multiple fistulae originating from both the left and the right coronary arteries and draining into the left ventricular chamber are a rare condition. Due to the low prevalence of these anomalies, the appropriate management of patients with symptomatic coronary artery fistulae is controversial. Transcatheter closure approaches have emerged as a less invasive strategy and are nowadays considered a valuable alternative to surgical correction with similar effectiveness, morbidity and mortality. The percutaneous management, however, is mainly limited by the individual anatomic features of the fistula and an appropriate patient's selection is considered as a key determining factor to achieve complete occlusion. Thus, success rates of transcatheter closure techniques reported in the literature are extremely variable and highly dependent upon the nature of the follow up, which, at present, is not standardized. The optimal management of symptomatic patients with multiple coronary artery fistulae still remains a challenging problem and has been traditionally considered as an indication for cardiac surgery. We report here the case of a patient with double bilateral congenital coronary artery fistulae arising from both the left and right coronary arteries and draining individually into the left ventricular chamber. This patient underwent successful transcatheter anterograde closure of both fistulae using a microcoil embolization technique.
Resumo:
The spatial resolution visualized with hydrological models and the conceptualized images of subsurface hydrological processes often exceed resolution of the data collected with classical instrumentation at the field scale. In recent years it was possible to increasingly diminish the inherent gap to information from point like field data through the application of hydrogeophysical methods at field-scale. With regards to all common geophysical exploration techniques, electric and electromagnetic methods have arguably to greatest sensitivity to hydrologically relevant parameters. Of particular interest in this context are induced polarisation (IP) measurements, which essentially constrain the capacity of a probed subsurface region to store an electrical charge. In the absence of metallic conductors the IP- response is largely driven by current conduction along the grain surfaces. This offers the perspective to link such measurements to the characteristics of the solid-fluid-interface and thus, at least in unconsolidated sediments, should allow for first-order estimates of the permeability structure.¦While the IP-effect is well explored through laboratory experiments and in part verified through field data for clay-rich environments, the applicability of IP-based characterizations to clay-poor aquifers is not clear. For example, polarization mechanisms like membrane polarization are not applicable in the rather wide pore-systems of clay free sands, and the direct transposition of Schwarz' theory relating polarization of spheres to the relaxation mechanism of polarized cells to complex natural sediments yields ambiguous results.¦In order to improve our understanding of the structural origins of IP-signals in such environments as well as their correlation with pertinent hydrological parameters, various laboratory measurements have been conducted. We consider saturated quartz samples with a grain size spectrum varying from fine sand to fine gravel, that is grain diameters between 0,09 and 5,6 mm, as well as corresponding pertinent mixtures which can be regarded as proxies for widespread alluvial deposits. The pore space characteristics are altered by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples, while keeping any electrochemical variability during the measurements as small as possible. The results do not follow simple assumptions on relationships to single parameters such as grain size. It was found that the complexity of natural occurring media is not yet sufficiently represented when modelling IP. At the same time simple correlation to permeability was found to be strong and consistent. Hence, adaptations with the aim of better representing the geo-structure of natural porous media were applied to the simplified model space used in Schwarz' IP-effect-theory. The resulting semi- empiric relationship was found to more accurately predict the IP-effect and its relation to the parameters grain size and permeability. If combined with recent findings about the effect of pore fluid electrochemistry together with advanced complex resistivity tomography, these results will allow us to picture diverse aspects of the subsurface with relative certainty. Within the framework of single measurement campaigns, hydrologiste can than collect data with information about the geo-structure and geo-chemistry of the subsurface. However, additional research efforts will be necessary to further improve the understanding of the physical origins of IP-effect and minimize the potential for false interpretations.¦-¦Dans l'étude des processus et caractéristiques hydrologiques des subsurfaces, la résolution spatiale donnée par les modèles hydrologiques dépasse souvent la résolution des données du terrain récoltées avec des méthodes classiques d'hydrologie. Récemment il est possible de réduire de plus en plus cet divergence spatiale entre modèles numériques et données du terrain par l'utilisation de méthodes géophysiques, notamment celles géoélectriques. Parmi les méthodes électriques, la polarisation provoquée (PP) permet de représenter la capacité des roches poreuses et des sols à stocker une charge électrique. En l'absence des métaux dans le sous-sol, cet effet est largement influencé par des caractéristiques de surface des matériaux. En conséquence les mesures PP offrent une information des interfaces entre solides et fluides dans les matériaux poreux que nous pouvons lier à la perméabilité également dirigée par ces mêmes paramètres. L'effet de la polarisation provoquée à été étudié dans différentes études de laboratoire, ainsi que sur le terrain. A cause d'une faible capacité de polarisation des matériaux sableux, comparé aux argiles, leur caractérisation par l'effet-PP reste difficile a interpréter d'une manière cohérente pour les environnements hétérogènes.¦Pour améliorer les connaissances sur l'importance de la structure du sous-sol sableux envers l'effet PP et des paramètres hydrologiques, nous avons fait des mesures de laboratoire variées. En détail, nous avons considéré des échantillons sableux de quartz avec des distributions de taille de grain entre sables fins et graviers fins, en diamètre cela fait entre 0,09 et 5,6 mm. Les caractéristiques de l'espace poreux sont changées en modifiant (i) la distribution de taille des grains, (ii) le degré de compaction, et (iii) le niveau d'hétérogénéité dans la distribution de taille de grains. En suite nous étudions comment ces changements influencent l'effet-PP, la perméabilité et la surface spécifique des échantillons. Les paramètres électrochimiques sont gardés à un minimum pendant les mesures. Les résultats ne montrent pas de relation simple entre les paramètres pétro-physiques comme par exemples la taille des grains. La complexité des media naturels n'est pas encore suffisamment représenté par les modèles des processus PP. Néanmoins, la simple corrélation entre effet PP et perméabilité est fort et consistant. En conséquence la théorie de Schwarz sur l'effet-PP a été adapté de manière semi-empirique pour mieux pouvoir estimer la relation entre les résultats de l'effet-PP et les paramètres taille de graines et perméabilité. Nos résultats concernant l'influence de la texture des matériaux et celles de l'effet de l'électrochimie des fluides dans les pores, permettront de visualiser des divers aspects du sous-sol. Avec des telles mesures géo-électriques, les hydrologues peuvent collectionner des données contenant des informations sur la structure et la chimie des fluides des sous-sols. Néanmoins, plus de recherches sur les origines physiques de l'effet-PP sont nécessaires afin de minimiser le risque potentiel d'une mauvaise interprétation des données.
Resumo:
Au sujet du "Roi Candaule" : craint de ne pouvoir achever l'instrumentation dans les délai fixé s'il lui faut reconstruire un acte entier : "N'y aurait-il pas un moyen d'ajouter au quatre, après le grand ensemble et sans rien y changer ce que vous voulez faire dire au Roi - ce serait en ce cas assez bref - et amener là les danses et les chants de la Résurrection d'Atys pour lesquels la nuit n'est point indispensable." (30 juin 1914) L'informe également que la lettre de Carré est une "excellente amorce pour Candaule" et qu'il faudrait agir dès le retour de Donnay : "les réceptions vont être innombrables à l'Opéra Comique et il ne faudrait pas que février nous devançât" (25 octobre 1918). Lui fixe un rendez-vous pour la lecture du livret au vendredi 20 juin 1919. (16 juin 1919) Évoque un autre projet avec son librettiste : "Avec quelle joie je commencerai la partition de ce "Jean-Jacques" auquel je ne cesse de penser et qui me passionne de plus en plus. Je vous devrai encore de belles heures." (27 juillet 1921)
Resumo:
PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.
Resumo:
The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
pH monitoring has been used as a diagnostic tool in gastro-oesophageal reflux disease (GERD) for many years. Recent studies have shown that wireless capsule pH monitoring is better tolerated and interferes less with daily activities as compared to traditional catheter-based pH monitoring. Moreover, prolonged recording time (48 h instead of 24 h) is possible with wireless pH monitoring. The main secondary effect of wireless capsule pH monitoring is induction of thoracic discomfort in 10-65% of the patients, which can vary from mild foreign body sensation to severe chest pain. Sensitivity and specificity of wireless capsule monitoring is comparable to that of traditional pH monitoring. It has not been proven yet that better tolerability and a longer recording time increases the diagnostic yield of wireless capsule monitoring in GERD.
Resumo:
Comentari sobre l'article publicat anteriorment pels mateixos autors: Vargas, M; Pallás, R; The seemingly paradoxical noise behaviour some active circuits. IEEE Transactions on Instrumentation and Measurement. 1994, vol. 43, núm. 5, p. 764-767
Resumo:
Teollisuuden automaatiojärjestelmät digitalisoituvat, samalla niiden tuottaman reaaliaikaisen datan määrä kasvaa ja etenkin sen saatavuus helpottuu. Samanaikaisesti laitevalmistajan liiketoimintamallit ovat muuttumassa perinteisestä konevalmistuksesta kohti palveluntarjontaa. Muuttuneessa tilanteessa laitteiden ohjauksessa käytettäviltä järjestelmiltä vaaditaan uusia ominaisuuksia. Informaation käsittely ja jalostaminen muodostuvat tärkeiksi kilpailu-tekijöiksi. Kirjallisuusosassa on tarkasteltu, miten data jalostuu informaatioksi ja siitä edelleen tietämykseksi. Työssä myös selvitetään, miten niitä voidaan hyödyntää liiketoiminnassa. Samalla perehdytään teollisuudesta löytyviin informaatio- ja tietämysjärjestelmiin. Kokeellisessa osassa esitellään toimiva tiedonkeruu- ja raportointijärjestelmä ja tutkitaan, miten sitä tulisi kehittää, jotta se sopisi paremmin muuttuviin liiketoimintamalleihin. Lopputuloksena kehitettiin mallijärjestelmä, jolla pystytään täyttämään laitevalmistajan ja loppukäyttäjän muuttuneet informaatiotarpeet osana laiteohjausta.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Tämän diplomityön tavoitteena oli testata ja optimoida erään alipainerumpusuodattimen toimivuutta, ja lisäksi maksimoida tuottavuus ja vertailla erilaisten pesumenetelmientehokkuutta. Testilietteiden ¿ rautarikasteen ja täyteainepastan ¿ karakterisointi oli myös tärkeää. Kirjallisuusosassa tarkasteltiin lyhyesti neste-kiintoaine-erotuksen teoriaa, erityisesti alipainesuodatusta ja alipainerumpusuodattimia. Lisäksi käsiteltiin kapillaarisuodatuksen toimintaperiaatteita sekä selvitettiin kaivosteollisuuden veden talteenottokeinoja, kiintoainejäämien käsittelymenetelmiä ja Chilen kaivosteollisuuden nykytilaa. Työn kokeellinen osa suoritettiin käyttämällä raskaita ja kiintoainepitoisuuksiltaan korkeita lietteitä, eli rautarikastetta ja täyteainepastaa. Kokeet suoritettiin erityisellä alipainerumpusuodattimella, joka oli muokattu perinteisestäpäältä syötettävästä alipainerumpusuodattimesta. Kokeissa tutkittiin pyörimisnopeuden ja erilaisten pesumenetelmien vaikutusta kakun kosteuteen ja suodatuskapasiteettiin. Koelietteiden karakterisointi suoritettiin analysoimalla partikkelikokojakauma, kiintoainepitoisuus, metallipitoisuus ja koostumus. Kokeiden perusteella havaittiin, että rummun pyörimisnopeudella ja lietteen kiintoainepitoisuudella on merkittävä vaikutus suodatuskapasiteettiin ja kakun kosteuspitoisuuteen. Havaittiin myös, että kakun kosteuspitoisuuksissa ja rummun suodatuskapasiteeteissa oli eroja, kun verrattiin eri suodatinväliaineen pesumenetelmiä. Täten oikean pesumenetelmän valinta on tärkeää, ja sillä pystytään lisäämään suodatinväliaineen käyttöikää.
Resumo:
Työn tavoitteena oli selvittää Suomenlahdella tapahtuvasta alusöljyvahingosta syntyvän öljyisen jätteen käsittelymahdollisuudet ja -kapasiteetit sekä loppusijoitusmahdollisuudet ja -kapasiteetit Kymenlaakson alueella. Lisäksi tavoitteena oli selvittää, miten öljy-vahinkojätettä voidaan esikäsitellä välivarastoinnin aikana puhdistuksen ja loppusijoituksen tehostamiseksi. Työn alussa on perehdytty öljyvahinkojätteen muodostumiseen vaikuttaviin tekijöihin: öljylaatujen ominaisuuksiin, öljyn kulkeutumiseen rannalle, ranta- ja saaristomaisemaan, öljyntorjuntaan jarantojen puhdistamiseen. Työssä on kuvattu öljyvahinkojätteen käsittelymenetelmien periaatteet ja menetelmien rajoituksia käsitellä öljyvahinkojätettä. Lisäksityö sisältää tutkimusta Suomen aluevesillä ja maailmalla tapahtuneista öljyonnettomuuksista. Onnettomuuksista on selvitetty erityisesti öljyvahinkojätteen määrä, koostumus ja käsittely. Työn loppuosassa on esitelty Kymenlaakson alueen laitosten mahdollisuuksia käsitellä öljyvahinkojätettä. Tietoa onkerätty haastattelemalla puhelimitse laitosten edustajia keväällä 2007. Alueella voidaan polttaa leijupedissä puhtaaseen polttoaineeseen sekoitettua öljyistä orgaanista ainesta ja puhdistustyössä käytettyjä varusteita arviolta 19 000 t/a, homogenoitua öljyistä orgaanista ainesta voidaan polttaa rumpu-uunissa arviolta 1200 t/a. Alueen polttokapasiteetti kasvaa, kun työn aikana rakenteilla oleva jätteenpolttolaitos valmistuu ja jätettä voidaan polttaa laitoksen arinalla. Lisäksi erityisesti öljyisiä maa-aineksia voidaan alipainekäsitellä, bitumistabiloida, kompostoida sekä pestä. Saadut tutkimustulokset ovat hyödynnettävissä erityisesti Kymenlaakson alueella. Tiedot käsittelymenetelmistä ja niiden rajoitteista ovat hyödynnettävissä valtakunnallisesti.
Resumo:
Every medical practitioner is confronted on a daily basis with emergencies. Among these, life-threatening emergencies can have disastrous consequences in term of morbidity and mortality; 22 cardiac arrests and 10 deaths were reported among the 1,650 Swiss practices during a 5 year period. The occurrence of life-threatening emergencies at the office necessitates, according to the type and place of the practice, the skills of the practitioner and the organization of his practice, the implementation of procedures, equipments (for example room equipped with a defibrillator, respiratory nebulizer, splints, emergency drugs) and specific continuous education programs that should be encouraged and made available to the whole medical corporation.