957 resultados para end user programming


Relevância:

20.00% 20.00%

Publicador:

Resumo:

El sistema implementado utiliza las redes sociales para proteger la privacidad de los usuarios e impedir que los motores de búsqueda de Internet (WSE) elaboren un perfil de usuario. Sin embargo, los WSE serán capaces de elaborar un perfil distorsionado pero útil hasta un cierto nivel para poder proveer un servicio apropiado al usuario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inconsistencies about dynamic asymmetry between the on- and off-transient responses in VO2 are found in the literature. Therefore the purpose of this study was to examine VO2 on- and off-transients during moderate- and heavy-intensity cycling exercise in trained subjects. Ten men underwent an initial incremental test for the estimation of ventilatory threshold (VT) and, on different days, two bouts of square-wave exercise at moderate (<VT) and heavy (>VT) intensities. VO2 kinetics in exercise and recovery were better described by a single exponential model (<VT), or by a double exponential with two time delays (>VT). For moderate exercise, we found a symmetry of VO2 kinetics between the on- and off-transients (i.e., fundamental component), consistent with a system manifesting linear control dynamics. For heavy exercise, a slow component superimposed on the fundamental phase was expressed in both the exercise and recovery, with similar parameter estimates. But the on-transient values of the time constant were appreciably faster than the associated off-transient, and independent of the work rate imposed (<VT and >VT). Our results do not support a dynamically linear system model of VO2 during cycling exercise in the heavy-intensity domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inconsistencies about dynamic asymmetry between the on- and off-transient responses in .VO2 are found in the literature. Therefore the purpose of this study was to examine .VO2on- and off-transients during moderate- and heavy-intensity cycling exercise in trained subjects. Ten men underwent an initial incremental test for the estimation of ventilatory threshold (VT) and, on different days, two bouts of square-wave exercise at moderate (<VT) and heavy (>VT) intensities. .VO2 kinetics in exercise and recovery were better described by a single exponential model (<VT) or by a double exponential with two time delays (>VT). For moderate exercise, we found a symmetry of .VO2 kinetics between the on- and off-transients (i.e., fundamental component), consistent with a system manifesting linear control dynamics. For heavy exercise, a slow component superimposed on the fundamental phase was expressed in both the exercise and recovery, with similar parameter estimates. But the on-transient values of the time constant were appreciably faster than the associated off-transient, and independent of the work rate imposed (<VT and >VT). Our results do not support a dynamically linear system model of .VO2 during cycling exercise in the heavy-intensity domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study introduces our continuous work to enhance the virtual classroom in order to provide faculty and students with an environment open to their needs, compliant with learning standards and, therefore compatible with other e-learning environments, and based on open source software. The result is a modulable, sustainable and interoperable learning environment that can be adapted to different teaching and learning situations by incorporating the LMS integrated tools as well as wikis, blogs, forums and Moodle activities among others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prospective assessment of pedicled extrathoracic muscle flaps for the closure of large intrathoracic airway defects after noncircumferential resection in situations where an end-to-end reconstruction seemed risky (defects of > 4-cm length, desmoplastic reactions after previous infection or radiochemotherapy). METHODS: From 1996 to 2001, 13 intrathoracic muscle transpositions (6 latissimus dorsi and 7 serratus anterior muscle flaps) were performed to close defects of the intrathoracic airways after noncircumferential resection for tumor (n = 5), large tracheoesophageal fistula (n = 2), delayed tracheal injury (n = 1) and bronchopleural fistula (n = 5). In 2 patients, the extent of the tracheal defect required reinforcement of the reconstruction by use of a rib segment embedded into the muscle flap followed by temporary tracheal stenting. Patient follow-up was by clinical examination bronchoscopy and biopsy, pulmonary function tests, and dynamic virtual bronchoscopy by computed tomographic (CT) scan during inspiration and expiration. RESULTS: The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. They were all successfully closed using muscle flaps with no mortality and all patients were extubated within 24 hours. Bronchoscopy revealed epithelialization of the reconstructions without dehiscence, stenosis, or recurrence of fistulas. The flow-volume loop was preserved in all patients and dynamic virtual bronchoscopy revealed no significant difference in the endoluminal cross surface areas of the airway between inspiration and expiration above (45 +/- 21 mm(2)), at the site (76 +/- 23 mm(2)) and below the reconstruction (65 +/- 40 mm(2)). CONCLUSIONS: Intrathoracic airway defects of up to 50% of the circumference may be repaired using extrathoracic muscle flaps when an end-to-end reconstruction is not feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human papillomavirus (HPV) is responsible for all cases of cervical cancer, as well as a great percentage of other anogenital tumors and oropharyngeal tumors. Since the main etiologic factor for these diseases is a virus, prophylactic measures are the best way to reduce the burden caused by the infection and associated disease. This review brings up to date information on the two commercially available prophylactic HPV vaccines against HPV, as well as presenting the ongoing research on HPV peptide, protein and dendritic cell based therapeutic vaccines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La llegada de las tecnologías de la información, y su uso cada vez mayor y generalizado que se está haciendo de ellas, ha permitido para que una nueva situación aparezca que, a su vez, ha originado - de hecho, que ha precipitado - una serie de cambios de gran importancia en todos los niveles, pero especialmente en los niveles sociales, económicos y culturales. Este nueva escena ha tenido una gran influencia en el entorno pedagógico. De hecho, la aparición de nuevos modelos educativos como resultado de este cambio ha estado sucediendo de una manera continuada e ininterrumpida durante la década pasada. Estos cambios recientes en los sistemas actuales de enseñanza y de aprendizaje han significado un aumento y un cambio en el tipo de demandas hechas desde las bibliotecas y los centros de documentación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general perspective of M-technologies and M-Services at the Spanish universities is not still in a very high level when we are ending the first decade of the 21st century. Some Universities and some of their libraries are starting to try out with M-technologies, but are still far from a model of massive exploitation, less than in some other countries. A deep study is needed to know the main reasons, study that we will not do in this paper. This general perspective does not mean that there are no significant initiatives which start to trust in M-technologies from Universities and their libraries. Models based in M-technologies make more sense than ever in open universities and in open libraries. That's the reason why the UOC's Library began in late 90s its first experiences in the M-Technologies and M-Libraries developments. In 1999 the appropriate technology offered the opportunity to carry out the first pilot test with SMS, and then applying the WAP technology. At those moments we managed to link-up mobile phones to the OPAC through a WAP system that allowed searching the catalogue by categories and finding the final location of a document, offering also the address of the library in which the user could loan it. Since then, UOC (and its library) directs its efforts towards adapting the offer of services to all sorts of M-devices used by end users. Left the WAP technology, nowadays the library is experimenting with some new devices like e-books, and some new services to get more feedback through the OPAC and metalibrary search products. We propose the case of Open University of Catalonia, in two levels: M-services applied in the library and M-technologies applied in some other university services and resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las aplicaciones que se distribuyen a través de Internet como un servicio (Software as a service, SaaS) y el hardware y software de base de los centros de datos (Nube, Cloud) son los dos elementos de la ecuación llamada cloud computing. En este paradigma, se juegan tres roles principales: proveedor del cloud, usuario del cloud que a su vez es proveedor de servicio (como los repositorios) y los usuarios finales del servicio. Los primeros se benefician de la especialización y las economías de escala; mientras que los segundos de una mayor elasticidad en el aprovisionamiento. En este sentido, DuraSpace ha creado un piloto llamado DuraCloud para probar el uso de tecnologías de almacenamiento en la nube para la preservación de contenido digital. El taller pretende describir los conceptos básicos del cloud, con ejemplos de donde se está usando este tipo de tecnología; y el impacto que puede tener en los repositorios digitales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the effects of interventions for promoting the use of advance directives (ADs) about end-of-life decisions of adults

Relevância:

20.00% 20.00%

Publicador:

Resumo:

More than seventy years after their initial characterisation, the aetiology of inflammatory bowel diseases remains elusive. A recent review evaluating the incidence trends of the last 25 years concluded that an increasing incidence has been observed almost worldwide. A north-south gradient is still found in Europe. Genetic associations are variably reproduced worldwide and indicate a strong impact of environmental factors. Tumour necrosis factor alpha (TNF-alpha) has been shown to play a critical role in the pathogenesis of inflammatory bowel disease (IBD). TNF-alpha blockers are biological agents that specifically target this key cytokine in the inflammatory process and have become a mainstay in the therapy of inflammatory bowel diseases. This paper reviews the necessary investigations before using such agents, the use of such agents in pregnancy and lactation, the role of co-immunosuppression, how to monitor efficacy and safety, dose-adaptation, and the decision as to when to switch to another TNF-alpha blocker. Finally it gives recommendations for special situations. Currently there are three TNF-alpha blockers available for clinical use in IBD in Switzerland: infliximab (Remicade), adalimumab (Humira) and certolizumab pegol (Cimzia). Infliximab is a chimeric monoclonal antibody composed of a human IgG1 constant region and a murine variable region and is administered intravenously. Adalimumab is a humanised monoclonal antibody, with both human IgG1 constant and variable regions. Certolizumab pegol is a pegylated, humanised monoclonal anti-TNF fragment antigen binding fragment. Both adalimumab and certolizumab pegol are administered by subcutaneous injection. The efficacy and safety of TNF-alpha blockers in Crohn's disease has been reviewed. The authors conclude that the three above-mentioned agents are effective in luminal Crohn's disease. In fistulizing Crohn's disease, TNF-alpha blockers other than infliximab require additional investigation.