978 resultados para a pump
Resumo:
This note has as objective to present the advantages of the use of syringe-type pumps for the feeding of liquid reactants, together with mass flow controllers for gases, instead of the saturators, as it is generally accomplished. Among the advantages, the system with syringe pumps presents a greater flexibility in flow control as well as in composition compared with the system that uses saturator. In addition, the flow of the liquid reactants is known with precision in the syringe pump system.
Resumo:
The main purpose of this thesis is to measure and evaluate how accurately the current energy saving calculation in ABB’s new variable speed drive ACS850 works. The main topic of this thesis is energy-efficiency parameters. At the beginning of this thesis centrifugal pump, squirrel cage motor and variable speed drive, including some equations related to them, are being introduced. Also methods of throttling control and variable speed drive control of centrifugal pumps are being introduced. These subjects are introduced because the energy saving calculation in ACS850 is related to the centrifugal pumps usually driven by squirrel cage motors. The theory also includes short section about specific energy of pumping. Before measurements the current energy saving calculation of ACS850 is being introduced and analyzed. The measurements part includes introduction of measuring equipment, measurement results, summary and analysis of the measurements. At the end of this thesis a proposal for an improvement to the current energy saving calculation is being introduced and few proposals are made for new energy-efficiency parameters, which could be added to variable speed drives. At the end are also thoughts
Resumo:
A new model for the H2 antagonists binding site is postulated based on adsorption coefficient values of sixteen antagonists, in the affinities constants of the primary and secondary binding sites, and in the chemical characterization of these sites by 3D-QSAR. All study compounds are in the extended conformation and deprotonated form. The lateral validation of the QSARs, CoMFA analysis, affinity constants and chemical similarity data suggest that the antagonists block the proton pump in the H2 receptor interacting with two tyrosines - one in the helix 5, and other in the helix 6.
Resumo:
This thesis includes several thermal hydraulic analyses related to the Loviisa WER 440 nuclear power plant units. The work consists of experimental studies, analysis of the experiments, analysis of some plant transits and development of a calculational model for calculation of boric acid concentrations in the reactor. In the first part of the thesis, in the case of won of boric acid solution behaviour during long term cooling period of LOCAs, experiments were performed in scaled down test facilities. The experimental data together with the results of RELAPS/MOD3 simulations were used to develop a model for calculations of boric acid concentrations in the reactor during LOCAs. The results of calculations showed that margins to critical concentrations that would lead to boric acid crystallization were large, both in the reactor core and in the lower plenum. This was mainly caused by the fact that water in the primary cooling circuit includes borax (Na)BsO,.IOHZO), which enters the reactor when ECC water is taken from the sump and greatly increases boric acid solubility in water. In the second part, in the case of simulation of horizontal steam generators, experiments were performed with PACTEL integral test loop to simulate loss of feedwater transients. The PACTEL experiments, as well as earlier REWET III natural circulation tests, were analyzed with RELAPS/MOD3 Version Sm5 code. The analysis showed that the code was capable of simulating the main events during the experiments. However, in the case of loss of secondary side feedwater the code was not completely capable to simulate steam superheating in the secondary side of the steam generators. The third part of the work consists of simulations of Loviisa VVER reactor pump trip transients with RELAPSlMODI Eur, RELAPS/MOD3 and CATHARE codes. All three codes were capable to simulate the two selected pump trip transients and no significant differences were found between the results of different codes. Comparison of the calculated results with the data measured in the Loviisa plant also showed good agreement.
Resumo:
A new configuration for coupling a gas diffusion cell to a sequential injection system is presented. The matrix exchange is made without the need for additional rotary injection valves or peristaltic pumps, keeping the original mechanical components of the sequential injection apparatus: one syringe pump (or peristaltic pump) and one selection valve. The system was tested constructing analytical curves for sulfide exploring the formation of the methylene blue dye. The proposed method has a detection limit of 60 µg L-1 S2-, with a linear dynamic range between 0.10 and 4.0 mg L-1 S2- concentrations, with a sampling frequency of 20 h-1.
Resumo:
Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).
Resumo:
Synchronous machines with an AC converter are used mainly in large drives, for example in ship propulsion drives as well as in rolling mill drives in steel industry. These motors are used because of their high efficiency, high overload capacity and good performance in the field weakening area. Present day drives for electrically excited synchronous motors are equipped with position sensors. Most drives for electrically excited synchronous motors will be equipped with position sensors also in future. This kind of drives with good dynamics are mainly used in metal industry. Drives without a position sensor can be used e.g. in ship propulsion and in large pump and blower drives. Nowadays, these drives are equipped with a position sensor, too. The tendency is to avoid a position sensor if possible, since a sensor reduces the reliability of the drive and increases costs (latter is not very significant for large drives). A new control technique for a synchronous motor drive is a combination of the Direct Flux Linkage Control (DFLC) based on a voltage model and a supervising method (e.g. current model). This combination is called Direct Torque Control method (DTC). In the case of the position sensorless drive, the DTC can be implemented by using other supervising methods that keep the stator flux linkage origin centered. In this thesis, a method for the observation of the drift of the real stator flux linkage in the DTC drive is introduced. It is also shown how this method can be used as a supervising method that keeps the stator flux linkage origin centered in the case of the DTC. In the position sensorless case, a synchronous motor can be started up with the DTC control, when a method for the determination of the initial rotor position presented in this thesis is used. The load characteristics of such a drive are not very good at low rotational speeds. Furthermore, continuous operation at a zero speed and at a low rotational speed is not possible, which is partly due to the problems related to the flux linkage estimate. For operation in a low speed area, a stator current control method based on the DFLC modulator (DMCQ is presented. With the DMCC, it is possible to start up and operate a synchronous motor at a zero speed and at low rotational speeds in general. The DMCC is necessary in situations where high torque (e.g. nominal torque) is required at the starting moment, or if the motor runs several seconds at a zero speed or at a low speed range (up to 2 Hz). The behaviour of the described methods is shown with test results. The test results are presented for the direct flux linkage and torque controlled test drive system with a 14.5 kVA, four pole salient pole synchronous motor with a damper winding and electric excitation. The static accuracy of the drive is verified by measuring the torque in a static load operation, and the dynamics of the drive is proven in load transient tests. The performance of the drive concept presented in this work is sufficient e.g. for ship propulsion and for large pump drives. Furthermore, the developed methods are almost independent of the machine parameters.
Resumo:
Voimistuvan kasvihuoneilmiön myötä kiinnostus hiilidioksidipäästöjen vähentämiseen on lisääntynyt. Ympäristöteknologian tavoitteena on hidastaa tämän ilmiön haitallisia vaikutuksia maailmanlaajuisesti, kansallisesti sekä yritystasolla. Yrityksillä on yhä suurempi paine valmistaa tuotteita ympäristöä vähemmän kuormittavasti. Työn tavoitteena on tarkastella elinkaariarvioinnin käytettävyyttä, kun halutaan tunnistaa pumpputehtaan mahdollisuuksia pienentää tuotteidensa valmistuksen ympäristönkuormittavuutta. Työssä pyritään myös selvittämään ne pumpun valmistuksen prosessit, jotka tuottavat eniten kasvihuonekaasupäästöjä. Tarkastelussa on keskitytty lähinnä hiilidioksidipäästöjen laskentaan. Työssä on käytetty elinkaariarvioinnin menetelmää ja työ noudattaa SFS ISO 14040 ja 14044 standardia. Elinkaariarviointi on hyväksi havaittu keino tunnistaa ne tuotteen tai palvelun yksikköprosessit, joilla on suurin vaikutus ympäristöön. Tutkimuksessa luotiin elinkaariarviointi pumppulaitoksen vuosittain tuottamille pumpuille. Samalla toteutettiin elinkaariarviointiin Excel-malli, jolla voidaan arvioida yksittäisten pumppujen valmistuksen hiilidioksidipäästöt. Tulosten pohjalta on tehty myös joitakin ehdotuksia pumpun valmistuksen hiilidioksidipäästöjen vähentämiseksi. Laskennassa käytetty aineisto kerättiin kirjallisuudesta, pumppulaitoksen alihankkijoilta sekä julkaistuista elinkaariarvioinneista vuoden 2008 kesän aikana. Työssä on osoitettu, että elinkaariarviointia voidaan hyödyntää tunnistettaessa pumpputehtaan ympäristötoimenpiteitä. Saatujen tulosten luotettavuus on kuitenkin riippuvainen käytettävissä olevista resursseista sekä lähtötietojen tarkkuudesta. Erityisesti valimoiden ilmoittamat energiankulutusmäärät vaikuttavat tulosten tarkkuuteen. Tarkempien tulosten saaminen edellyttäisi muun muassa tehtaan alihankkijoiden parempaa tietoisuutta omasta energiankulutuksestaan.
Resumo:
Pantoprazole is a proton pump inhibitor used in the treatment of digestive ulcers, gastro-esophageal reflux disease and in the eradication of Helicobacter pylori. In this work, an analytical method was developed and validated for the quantification of sodium pantoprazole by HPLC. The method was specific, linear, precise and exact. In order to verify the stability of pantoprazole during dissolution assays, pantoprazole solution in phosphate buffer pH 7.4 was kept at room temperature and protected from light for 22 days. Pantoprazole presented less than 5% of degradation in 6 hours and the half live of the degradation was 124 h.
Resumo:
Considering the attraction of the students' attention by the changes in the colors of vegetable crude extracts caused by the variation of the pH of the medium, the use of these different colors in order to demonstrate principles of spectrophotometric acid-base titrations using the crude extracts as indicators is proposed. The experimental setup consisted of a simple spectrophotometer, a homemade flow cell and a pump to propel the fluids along the system. Students should be stimulated to choose the best wavelength to monitor the changes in color during the titration. Since the pH of the equivalence point depends on the system titrated, the wavelength must be properly chosen to follow these changes, demonstrating the importance of the correct choice of the indicator. When compared with the potentiometric results, errors as low as 2% could be found using Rhododendron simsii (azalea) or Tibouchina granulosa (Glory tree, quaresmeira) as sources of the crude extracts.
Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo
Resumo:
This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.
Resumo:
Energiatehokkuus sekä ilmastonmuutos ovat aiheuttaneet pyrkimyksen vähentää kokonaisenergiankulutuksia erilaisissa rakennuksissa. Lämmitysjärjestelmissä tämä on näkynyt voimakkaana lämpöpumppumäärien kasvuna. Lämpöpumput vaikuttavat erilaisissa rakennus- ja lämmitystyypeissä myös sähköenergiankulutukseen. Lämpöpumppujen käytöstä saadaan eniten hyötyä lämmityskustannuksiin sähkölämmitteisissä rakennuksissa. Seurauksena on, että tällaisen rakennuksen sähkönkulutus ja siten myös sähkölasku pienenevät. Toisaalta muihin kuin sähkölämmitteisiin rakennuksiin asennettu lämpöpumppu kasvattaa sähköenergiankulutusta. Lämpöpumppuihin integroitu jäähdytysominaisuus myös tavallisesti lisää sähkönkulutusta. Tämän tutkimuksen tarkoituksena on selvittää, kuinka lämpöpumput vaikuttavat sähköenergiankulutukseen. Vaikutuksia tutkitaan sähköverkkoyhtiöiden kannalta sähköenergian ja liikevaihdon osalta. Tarkastelussa käytetään neljää yleisintä lämpöpumpputyyppiä, ja niiden toimintaa verrataan eri rakennustyyppien lämmitysjärjestelmiin. Työssä käsitellään lämpöpumppujen toimintaa ja käytettävyyttä muiden lämmitysmenetelmien korvaajina tai lisänä. Tämän kirjallisen työn lisäksi on tehty laskentaohjelma, joka on perusteena työssä esitetyille tuloksille. Sen tarkoituksena on selvittää lämpöpumppujen vaikutukset sähköverkkoliiketoimintaan energiayhtiöissä. Vaikutukset yksittäiseen energiayhtiöön ovat eniten riippuvaisia lämpöpumppujen asennuskohteista, lämpöpumppujen toiminnasta ja lämpöpumpputyypistä. Kuluttajat tulevat määräämään vaikutusten suuruuden, koska lämpöpumppujen lukumäärällä ja käytöllä on sähköenergiankulutukseen huomattava merkitys. Vaikutus sähköenergiaan energiayhtiöiden kannalta voi yleisesti ottaen olla 2020-luvulle mentäessä merkittävä. Tutkittavassa verkkoyhtiössä vaikutuksen sähköenergiaan arvioidaan olevan 10 % luokkaa yhdeltä vuodelta verrattuna tämän päivän kokonaissähköenergiankulutukseen. Vaikutus verkkoliikevaihtoon on arviolta puolet pienempi. Tällaiset tulokset edellyttävät lämpöpumppumäärän moninkertaistumista nykyisestä, mikä on myös odotettavissa.
Resumo:
Tässä tekniikankandidaatin työssä käsitellään keskipakopumpun prosessiteknistä mitoittamista, pumppumäärittelyjä ja valintaa. Työssä esitetään kaksi mitoitustapausta ja kolmen pumpun määrittelyt sekä valinta todellisissa prosesseissa.
Resumo:
Rare earth ion doped solid state materials are the most important active media of near-infrared and visible lasers and other photonic devices. In these ions, the occurrence of Excited State Absorptions (ESA), from long lived electronic levels, is commonplace. Since ESA can deeply affect the efficiencies of the rare earth emissions, evaluation of these transitions cross sections is of greatest importance in predicting the potential applications of a given material. In this paper a detailed description of the pump-probe technique for ESA measurements is presented, with a review of several examples of applications in Nd3+, Tm3+ and Er3+ doped materials.
Resumo:
Vacuum pumps are very useful in physical, chemical and biological experiments. In this communication it is described the design of a compact and low cost water recirculating system employing a water-jet aspirator pump as the vacuum source. The system requires only a water pump, water-jet aspirator pump, commercial PVC water tubes and a drain connection.