991 resultados para Variable-chromosome-length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTObjective:to analyze the associated factors with empyema in patients with post-traumatic retained hemothorax.Methods:prospective observational study. Data were collected in patients undergoing PD during emergency duty. Variables analyzed were age, sex, mechanism of injury, side of the chest injury, intrathoracic complications of RH, laparotomy, specific injuries, rib fractures, trauma scores, days to diagnosis, diagnostic method of RH, primary indication of PD, initial volume drained, length of the first tube removal, surgical procedure. Cumulative incidence of empyema, pneumonia and pulmonary contusion and the proportion of patients with empyema or without empyema in each category of each variable analyzed were obtained.Results: the cumulative incidence of PD among trauma patients was 1.83% and the RH among those with PD was 10.63%. There were 20 cases of empyema (32.8%). Most were male in the age from 20 to 29, victims of injury by firearm on the left side of the thorax. The incidence of empyema in patients with injury by firearms was lower compared to those with stab wound or blunt trauma; higher among those with drained volume between 300 and 599 ml. The median hospital lenght of stay was higher among those with empyema.Conclusion:the incidence of PD was 1.83% and RH was 10.63%, these results are consistent with the low severity of the patients involved in this study and consistent with the literature. The incidence of empyema proved to be negatively associated with the occurrence of injury by firearms and positively associated with a drained volume between 300 and 599 ml, compared with lower or higher volumes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTObjective:to investigate the effect of standardized interventions in the management of tube thoracostomy patients and to assess the independent effect of each intervention.Methods:A chest tube management protocol was assessed in a retrospective cohort study. The tube thoracostomy protocol (TTP) was implemented in August 2012, and consisted of: antimicrobial prophylaxis, chest tube insertion in the operating room (OR), admission post chest tube thoracostomy (CTT) in a hospital floor separate from the emergency department (ED), and daily respiratory therapy (RT) sessions post-CTT. The inclusion criteria were, hemodynamic stability, patients between the ages of 15 and 59 years, and injury severity score (ISS) < 17. All patients had isolated injuries to the chest wall, lung, and pleura. During the study period 92 patients were managed according to the standardized protocol. The outcomes of those patients were compared to 99 patients treated before the TTP. Multivariate logistic regression analysis was performed to assess the independent effect of each variable of the protocol on selected outcomes.Results:Demographics, injury severity, and trauma mechanisms were similar among the groups. As expected, protocol compliance increased after the implementation of the TTP. There was a significant reduction (p<0.05) in the incidence of retained hemothoraces, empyemas, pneumonias, surgical site infections, post-procedural complications, hospital length of stay, and number of chest tube days. Respiratory therapy was independently linked to significant reduction (p<0.05) in the incidence of seven out of eight undesired outcomes after CTT. Antimicrobial prophylaxis was linked to a significant decrease (p<0.05) in retained hemothoraces, despite no significant (p<0.10) reductions in empyema and surgical site infections. Conversely, OR chest tube insertion was associated with significant (p<0.05) reduction of both complications, and also significantly decreased the incidence of pneumonias.Conclusion:Implementation of a TTP effectively reduced complications after CTT in trauma patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate histological changes in dairy cows' hooves with or without injuries from naturally acquired laminitis. Cull cows with no clinical signs of hoof abnormalities (G1, n=9) and those with macroscopic lesions associated with laminitis without (G2, n=23) or with lameness (G3, n=7) were used in the study. After slaughter, samples of dermo-epidermal junctions of sole, axial and dorsal regions of the hoof were obtained and histologically processed using HE and PAS staining. Congestion, hemorrhage and inflammatory infiltrate in the dermis of sole, axial and dorsal regions were blindly and semiquantitatively evaluated by the same researcher. Inflammatory infiltrate was evaluated in the dermal laminae of axial and dorsal regions. The morphology of epidermal cells and the presence of irregularities in three regions of the basement membrane (BM) length were examined using PAS staining. Scores of lesions in different regions of the hoof in the same group and in different groups for each region of the hoof were compared using non-parametric analyses. Inflammatory infiltrate in the dermis of all regions of the hoof was detected in all groups with no significant statistical difference. Cows with no clinical signs of hoof abnormalities secondary to laminitis (G1) have inflammation scores and epidermal cell changes similar to those of groups with laminitis injuries, suggesting the existence of a prodromal phase for this disease in bovines. BM had irregularities with a variable intensity along its length, however, with no difference among groups. The pattern of BM irregularities found has not been reported so far and does not resemble the BM collapse described in horses and cattle with induced acute laminitis. Is it concluded that even in the absence of macroscopic hoof signs associated to laminitis, dairy cows have histological injuries compatible with inflammation of the dermo-epidermal junction as in affected animals. Basement membrane of cows with or without laminitis associated lesions had irregularities with an irregular distribution along its length which need to be further studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The agouti species Dasyprocta prymnolopha (D. prymnolopha) is a medium-sized rodent, diurnal, and characteristic of northeastern Brazil, south of the Amazon. Several studies have been made on these rodents. However, there is a lack of analysis of masticatory system, in particular morphology of the teeth. Thus, this research seeks to describe anatomical and histological aspects of the agouti teeth. For this purpose, we used adult agouti, in which measurements and descriptions of teeth and dental tissues were made. It was observed that the dental arch of D. prymnolopha comprises of twenty teeth, evenly distributed in the upper and lower arch, being inferior teeth larger than their corresponding higher. The incisors are larger, and between the posterior premolars and molars, there is a gradual increase in length in the anterior-posterior arch. In microscopic examination, a prismatic appearance was observed consisting of enamel prisms arranged in different directions, behind the enamel and dentin with standard tubular dentinal tubules with variable diameter and far between, also showing a sinuous path from the inner portion to the junction with more superficial enamel. Morphological analysis of dental tissues showed that an enamel with structural organization adapted to the act of chewing and high impact dentin compatible with standard tubular function resilience and mechanical damping of masticatory forces, as found in larger animals, confirming the understanding of eating habits that define much of its ecological functions within the ecosystem they inhabit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrocardiography (ECG) QT interval is influenced by fluctuations in heart rate (HR) what may lead to misinterpretation of its length. Considering that alterations in QT interval length reflect abnormalities of the ventricular repolarisation which predispose to occurrence of arrhythmias, this variable must be properly evaluated. The aim of this work is to determine which method of correcting the QT interval is the most appropriate for dogs regarding different ranges of normal HR (different breeds). Healthy adult dogs (n=130; German Shepherd, Boxer, Pit Bull Terrier, and Poodle) were submitted to ECG examination and QT intervals were determined in triplicates from the bipolar limb II lead and corrected for the effects of HR through the application of three published formulae involving quadratic, cubic or linear regression. The mean corrected QT values (QTc) obtained using the diverse formulae were significantly different (ρ<0.05), while those derived according to the equation QTcV = QT + 0.087(1- RR) were the most consistent (linear regression). QTcV values were strongly correlated (r=0.83) with the QT interval and showed a coefficient of variation of 8.37% and a 95% confidence interval of 0.22-0.23 s. Owing to its simplicity and reliability, the QTcV was considered the most appropriate to be used for the correction of QT interval in dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of a robust position controller for a robotic manipulator moving in free space is presented. The aim is to implement in practice a controller that is robust to uncertainties in the model of the system, as well as being inexpensive from a computational point of view. Variable structure theory provides the technique for the design of such controller. The design steps are presented, first from a theoretical perspective and then applied to the control of a two degree-of-freedom manipulator. Simulation results that backed the implementation are presented, followed by the experiments conducted and the results that were obtained. The conclusion is that variable structure control is readily applicable to industrial robots for the robust control of positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Control of an industrial robot is mainly a problem of dynamics. It includes non-linearities, uncertainties and external perturbations that should be considered in the design of control laws. In this work, two control strategies based on variable structure controllers (VSC) and a PD control algorithm are compared in relation to the tracking errors considering friction. The controller's performances are evaluated by adding an static friction model. Simulations and experimental results show it is possible to diminish tracking errors by using a model based friction compensation scheme. A SCARA robot is used to illustrate the conclusions of this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fan systems are responsible for approximately 10% of the electricity consumption in industrial and municipal sectors, and it has been found that there is energy-saving potential in these systems. To this end, variable speed drives (VSDs) are used to enhance the efficiency of fan systems. Usually, fan system operation is optimized based on measurements of the system, but there are seldom readily installed meters in the system that can be used for the purpose. Thus, sensorless methods are needed for the optimization of fan system operation. In this thesis, methods for the fan operating point estimation with a variable speed drive are studied and discussed. These methods can be used for the energy efficient control of the fan system without additional measurements. The operation of these methods is validated by laboratory measurements and data from an industrial fan system. In addition to their energy consumption, condition monitoring of fan systems is a key issue as fans are an integral part of various production processes. Fan system condition monitoring is usually carried out with vibration measurements, which again increase the system complexity. However, variable speed drives can already be used for pumping system condition monitoring. Therefore, it would add to the usability of a variablespeed- driven fan system if the variable speed drive could be used as a condition monitoring device. In this thesis, sensorless detection methods for three lifetime-reducing phenomena are suggested: these are detection of the fan contamination build-up, the correct rotational direction, and the fan surge. The methods use the variable speed drive monitoring and control options for the detection along with simple signal processing methods, such as power spectrum density estimates. The methods have been validated by laboratory measurements. The key finding of this doctoral thesis is that a variable speed drive can be used on its own as a monitoring and control device for the fan system energy efficiency, and it can also be used in the detection of certain lifetime-reducing phenomena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protein engineering aims to improve the properties of enzymes and affinity reagents by genetic changes. Typical engineered properties are affinity, specificity, stability, expression, and solubility. Because proteins are complex biomolecules, the effects of specific genetic changes are seldom predictable. Consequently, a popular strategy in protein engineering is to create a library of genetic variants of the target molecule, and render the population in a selection process to sort the variants by the desired property. This technique, called directed evolution, is a central tool for trimming protein-based products used in a wide range of applications from laundry detergents to anti-cancer drugs. New methods are continuously needed to generate larger gene repertoires and compatible selection platforms to shorten the development timeline for new biochemicals. In the first study of this thesis, primer extension mutagenesis was revisited to establish higher quality gene variant libraries in Escherichia coli cells. In the second study, recombination was explored as a method to expand the number of screenable enzyme variants. A selection platform was developed to improve antigen binding fragment (Fab) display on filamentous phages in the third article and, in the fourth study, novel design concepts were tested by two differentially randomized recombinant antibody libraries. Finally, in the last study, the performance of the same antibody repertoire was compared in phage display selections as a genetic fusion to different phage capsid proteins and in different antibody formats, Fab vs. single chain variable fragment (ScFv), in order to find out the most suitable display platform for the library at hand. As a result of the studies, a novel gene library construction method, termed selective rolling circle amplification (sRCA), was developed. The method increases mutagenesis frequency close to 100% in the final library and the number of transformants over 100-fold compared to traditional primer extension mutagenesis. In the second study, Cre/loxP recombination was found to be an appropriate tool to resolve the DNA concatemer resulting from error-prone RCA (epRCA) mutagenesis into monomeric circular DNA units for higher efficiency transformation into E. coli. Library selections against antigens of various size in the fourth study demonstrated that diversity placed closer to the antigen binding site of antibodies supports generation of antibodies against haptens and peptides, whereas diversity at more peripheral locations is better suited for targeting proteins. The conclusion from a comparison of the display formats was that truncated capsid protein three (p3Δ) of filamentous phage was superior to the full-length p3 and protein nine (p9) in obtaining a high number of uniquely specific clones. Especially for digoxigenin, a difficult hapten target, the antibody repertoire as ScFv-p3Δ provided the clones with the highest affinity for binding. This thesis on the construction, design, and selection of gene variant libraries contributes to the practical know-how in directed evolution and contains useful information for scientists in the field to support their undertakings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The degree of flowering and fruiting synchronization is believed to have ecological and evolutionary relevance at several scales. Here we discuss some measures that have been used to estimate synchrony and propose an index that incorporates both the entire length of an individual phenophase and variation in the number of flowers or fruits over that time period. This new index describes more accurately the phenological synchrony among individuals and populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The karyotype of Akodon cursor (initially identified as A. arviculoides) had been reported with chromosomal numbers 14 and 15 in the South and Southeast and 16 in Northeastern Brazil. We found the three cytotypes in a region of Southern Brazil. The G-band patterns of these specimens were the same as those from southeastern and northeastern regions. Seventeen different combinations of chromosomes due to a complex rearrangement in pair 1 and pericentric inversions in pairs 2 and 3 were identified. Seven of these combinations are new to in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatid gaps and breaks induced by the restriction endonucleases AluI and BamHI in the long arm of chromosome 1 of Chinese hamster ovary cells were microphotometrically scanned and mapped to a quantitative G-band map. More than 50% of chromatid breaks appeared as chromatin losses of greater than 5% of the total arm length. The majority of chromatid gaps and breaks as well as chromatin losses induced by both restriction endonucleases were non-randomly located in a region from 0.35 to 0.65 relative length units of the long arm of chromosome 1. We suggest that the access of these endonucleases to chromosomal DNA depends on the local organization of the chromatin.