979 resultados para Triglyceride levels


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we report calculations of energy levels, radiative rates and electron impact excitation rates for transitions in Li-like N V, F VII, Ne VIII and Na IX. The general-purpose relativistic atomic structure package (GRASP) is adopted for calculating energy levels and radiative rates, while for determining the collision strengths and subsequently the excitation rates, the Dirac atomic R-matrix code (DARC) and the flexible atomic code (FAC) are used. Oscillator strengths, radiative rates and line strengths are reported for all E1, E2, M1 and M2 transitions among the lowest 24 levels of N V, F VII, Ne VIII and Na IX. Collision strengths have been averaged over a Maxwellian velocity distribution and the effective collision strengths so obtained are reported over a wide temperature range below 10(6.6) K. Additionally, lifetimes are also reported for all calculated levels of the above four ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy levels, radiative rates, oscillator strengths, line strengths, and lifetimes have been calculated for transitions in B-like to F-like Xe ions, Xe L–XLVI. For the calculations, a fully relativistic grasp code has been adopted, and results are reported for all electric dipole, electric quadrupole, magnetic dipole, and magnetic quadrupole transitions among the lowest 125, 236, 272, 226, and 113 levels of Xe L, Xe XLIX, Xe XLVIII, Xe XLVII, and Xe XLVI, respectively, belonging to the n ⩽ 3 configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report calculations of energy levels, radiative rates and electron impact excitation cross
sections and rates for transitions in He-like Cl XVI, K XVIII, Ca XIX and Sc XX. The grasp
(general-purpose relativistic atomic structure package) is adopted for calculating energy levels
and radiative rates. To determine the collision strengths and subsequently the excitation rates,
the Dirac atomic R-matrix code (darc) is used. Oscillator strengths, radiative rates and line
strengths are reported for all E1, E2, M1 and M2 transitions among the lowest 49 levels of
each ion. Collision strengths are averaged over a Maxwellian velocity distribution and the
effective collision strengths obtained listed over a wide temperature range up to 107.4 K.
Comparisons are made with similar data obtained from the flexible atomic code (fac) to
highlight the importance of resonances, included in calculations with darc, in the
determination of effective collision strengths. Discrepancies between the collision strengths
from darc and fac, particularly for forbidden transitions, are also discussed. Additionally,
theoretical lifetimes are listed for all the 49 levels of the above four ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the rationale and possible indications for the use of recombinant erythropoietin in paroxysmal nocturnal haemoglobinuria (PNH), we have measured endogenous erythropoietin (Epo) levels in 18 patients with PNH and in 44 patients with iron deficiency anaemia (IDA), In both groups of patients we found a significant inverse correlation between Epo and haemoglobin (Hb). However, the mean Epo level was significantly higher in the PNH group (385 mU/ml) than in the IDA group (136 mU/ml), The range of Epo levels at any given Hb was greater in the PNH group than in the IDA group. There was a significant positive correlation between Epo and absolute reticulocyte count, Since Epo administration is unlikely to benefit patients with high levels of endogenous Epo, we conclude that in the majority of patients with PNH there is no indication for treatment with Epo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxidative stress may increase lung permeability by upregulation of matrix-metalloproteinase-9 (MMP-8), a type-IV collagenase that can disrupt alveolar basement membranes. We have compared a marker of oxidative stress (protein carbonyl residues) with levels of MMP-8 and its inhibitor, tissue inhibitor of metalloproteinase-1 (TIMP-1), in bronchoalveolar lavage samples from newborn babies. Bronchoalveolar lavage samples (n = 87, two from each time point) were taken in the first 6 postnatal days from 41 ventilated babies: 18 of