944 resultados para Routine
Resumo:
A portable type warp load meter has been developed for the use in fishing trawlers. The instrument enables to monitor the warp load in fishing trawlers accurately and easily without disturbing the routine fishing operations. The instrument can be used in several other places like cranes, bollard tests for marine engines, dry docks etc. especially when the operation has to be conducted easily without disturbing the load system. The information displayed in micro ammeter in the range 0 to 1000 kg can be fed to continuous recorders for detailed analysis and permanent records.
Resumo:
An instrument developed for the rapid and accurate measurement of brine concentrations during blanching without disturbing the routine blanching operation is described. The concentration is sensed by a platinum electrode conductivity cell and displayed in a moving coil meter after conversion of the electrical signals into D.C. voltage. The instrument can measure in the range 5 to 12% with an accuracy of ± 1%. The errors caused mostly are those due to wide temperature variations of the brine between 95 to 102°C and the unknown quantities of protein.
Resumo:
The paper describes the technical and operational features of a composite equipment for simultaneous measurement of five important parameters, warp load, boat speed, water temperature, water salinity and air temperature pertaining to the craft, gear and the environment. The equipment is designed for continuous measurement in small and medium crafts easily without disturbance to routine fishing operations. The system operated on 9V supply, is suitable for portable operations from one vessel to another. The compact electronic meter kept in the wheel-house displays the data one by one in engineering units.
Resumo:
This project was on “Study of Slurry, as an enrichment compound, on growth and survival parameters of Rutilus firisii kutum Kamensky 1901 larva and compare with routine condition according to hypothesis that use of Slurry, fertile organic compound, to increase the efficiency of survivorship and growth of Rutilus firisii and in other hand adaptation of natural food was performance.” The object of this project is to compare growth of Rutilus firisii and in usual condition and the condition of use Slurry The experiences performed in culture and propagation center Dr. Yousefpour decent (Associan of Dr. Beheshti culture and propagation) in Siahkal village, 32 Km far from southeast, in North of Iran. In this plan, three different treatments and related these nine pools , in 1.7 hec area (in same condition) were determined so that the density of storage was 1.7 million/hec larva. In this research at first treatment m we use slurry as enrichment compound during larval within a period of 13 days, and it used all the days of during larval in second treatment. Then the result of this study compared to control treatment. The results have shown the level of this study compared to control treatment. The results have shown the level of survivorship in pools were nutrition by slurry was 1.7 million times or twice than pools were nutrition with usual concentrate. In addition, growth coefficient such as daily weight growing (DWG) index, daily length growth (DLG), specific growth ratio (SGR) were measured in this case. All of these parameters in slurry treatment were shown noticeable enhancement in first treatment Thereof in the first week there was significant difference (P<0.001) between the average of length and weight in first week , and in the second week there was a significant difference (P<0.05) between them.
Resumo:
Sequence analysis of the mitochondrial genome has become a routine method in the study of mitochondrial diseases. Quite often, the sequencing efforts in the search of pathogenic or disease-associated mutations are affected by technical and interpretive pr
Resumo:
Given its relative ease, screening the entire mitochondrial DNA (mtDNA) for heteroplasmic or novel homoplasmic mutations has become part of the routine diagnostic workup for the molecular geneticist confronted with a disease case exhibiting clinical and b
Resumo:
Purpose: The paper examines how a number of key themes are introduced in the Masters programme in Engineering for Sustainable Development at Cambridge University through student centred activities. These themes include dealing with complexity, uncertainty, change, other disciplines, people, environmental limits, whole life costs, and trade-offs. Design/methodology/approach: The range of exercises and assignments designed to encourage students to test their own assumptions and abilities to develop competencies in these areas are analysed by mapping the key themes onto the formal activities which all students undertake throughout the core MPhil programme. The paper reviews the range of these activities that are designed to help support the formal delivery of the taught programme. These include residential field courses, role plays, change challenges, games, systems thinking, multi criteria decision making, awareness of literature from other disciplines and consultancy projects. An axial coding approach to the analysis of routine feedback questionnaires drawn from recent years has been used to identify how student’s own awareness develops. Also results of two surveys are presented which tests the students’ perceptions about whether or not the course is providing learning environments to develop awareness and skills in these areas. Findings: Students generally perform well against these tasks with a significant feature being the mutual support they give to each other in their learning. The paper concludes that for students from an engineering background it is an holistic approach to delivering a new way of thinking through a combination of lectures, class activities, assignments, interactions between class members, and access to material elsewhere in the University that enables participants to develop their skills in each of the key themes. Originality /value: The paper provides a reflection on different pedagogical approaches to exploring key sustainable themes and reports students own perceptions of the value of these kinds of activities. Experiences are shared of running a range of diverse learning activities within a professional practice Masters programme.
Resumo:
OBJECTIVE: This work is concerned with the creation of three-dimensional (3D) extended-field-of-view ultrasound from a set of volumes acquired using a mechanically swept 3D probe. 3D volumes of ultrasound data can be registered by attaching a position sensor to the probe; this can be an inconvenience in a clinical setting. A position sensor can also cause some misalignment due to patient movement and respiratory motion. We propose a combination of three-degrees-of-freedom image registration and an unobtrusively integrated inertial sensor for measuring orientation. The aim of this research is to produce a reliable and portable ultrasound system that is able to register 3D volumes quickly, making it suitable for clinical use. METHOD: As part of a feasibility study we recruited 28 pregnant females attending for routine obstetric scans to undergo 3D extended-field-of-view ultrasound. A total of 49 data sets were recorded. Each registered data set was assessed for correct alignment of each volume by two independent observers. RESULTS: In 77-83% of the data sets more than four consecutive volumes registered. The successful registration relies on good overlap between volumes and is adversely affected by advancing gestational age and foetal movement. CONCLUSION: The development of reliable 3D extended-field-of-view ultrasound may help ultrasound practitioners to demonstrate the anatomical relation of pathology and provide a convenient way to store data.
Resumo:
Humans are creatures of routine and habit. When faced with situations in which a default option is available, people show a consistent tendency to stick with the default. Why this occurs is unclear. To elucidate its neural basis, we used a novel gambling task in conjunction with functional magnetic resonance imaging. Behavioral results revealed that participants were more likely to choose the default card and felt enhanced emotional responses to outcomes after making the decision to switch. We show that increased tendency to switch away from the default during the decision phase was associated with decreased activity in the anterior insula; activation in this same area in reaction to "switching away from the default and losing" was positively related with experienced frustration. In contrast, decisions to choose the default engaged the ventral striatum, the same reward area as seen in winning. Our findings highlight aversive processes in the insula as underlying the default bias and suggest that choosing the default may be rewarding in itself.
Resumo:
This paper presents a method for the linear analysis of the stiffness and strength of open and closed cell lattices with arbitrary topology. The method hinges on a multiscale approach that separates the analysis of the lattice in two scales. At the macroscopic level, the lattice is considered as a uniform material; at the microscopic scale, on the other hand, the cell microstructure is modelled in detail by means of an in-house finite element solver. The method allows determine the macroscopic stiffness, the internal forces in the edges and walls of the lattice, as well as the global periodic buckling loads, along with their buckling modes. Four cube-based lattices and nine cell topologies derived by Archimedean polyhedra are studied. Several of them are characterized here for the first time with a particular attention on the role that the cell wall plays on the stiffness and strength properties. The method, automated in a computational routine, has been used to develop material property charts that help to gain insight into the performance of the lattices under investigation. © 2012 Elsevier B.V.
Resumo:
We show the feasibility of using quantum Monte Carlo (QMC) to compute benchmark energies for configuration samples of thermal-equilibrium water clusters and the bulk liquid containing up to 64 molecules. Evidence that the accuracy of these benchmarks approaches that of basis-set converged coupled-cluster calculations is noted. We illustrate the usefulness of the benchmarks by using them to analyze the errors of the popular BLYP approximation of density functional theory (DFT). The results indicate the possibility of using QMC as a routine tool for analyzing DFT errors for non-covalent bonding in many types of condensed-phase molecular system.
Resumo:
Against a background of increasing energy demand and rising fuel prices, hybrid-electric propulsion systems (HEPS) have the potential to significantly reduce fuel consumption in the aviation industry, particularly in the lighter sectors. By taking advantage of both Electric Motor (EM) and Internal Combustion Engine (ICE), HEPS provide not only a benefit in fuel saving but also a reduction in take-off noise and the emission levels. This research considers the design and sizing process of a hybrid-electric propulsion system for a single-seat demonstrator aircraft, the experimental derivation of the ICE map and the EM parameters. In addition to the experimental data, a novel modeling approach including several linked desktop PC software packages is presented to analyze and optimize hybrid-electric technology for aircraft. Further to the analysis of a parallel hybrid-electric, mid-scale aircraft, this paper also presents a scaling approach for a 20 kg UAV and a 50 tonne inter-city airliner. At the smaller scale, two different mission profiles are analyzed: an ISR mission profile, where the simulation routine optimizes the component size of the hybrid-electric propulsion system with respect to fuel saving, and a maximum duration profile; where the flight endurance is determined as a function of payload weight. At the larger scale, the performance of a 50 tonne inter-city airliner is modeled, based on a hybrid-electric gas-turbine, assuming a range of electric boost powers and battery masses.
Resumo:
The fundamental contact mechanics principles underlying nanoindentation testing techniques are reviewed. A range of material constitutive responses are covered, including elastic, plastic, and viscous deformation, and incorporating indentation of linearly viscoelastic materials and poroelastic materials. Emphasis is on routine analysis of experimental nanoindentation data, including deconvolution techniques for material properties measurements during indentation. In most cases, an analytical approach for an isotropic half-space is considered. Special cases are briefly described, including anisotropic materials, inhomogeneous composite materials and layered filmsubstrate systems. © 2011 by Pan Stanford Publishing Pte. Ltd. All rights reserved.
Resumo:
A multi-functional 1 × 9 wavelength selective switch based on liquid crystal on silicon (LCOS) spatial light modulator technology and anamorphic optics was tested at a channel spacing of 100 and 200 GHz, including dynamic data measurements on both single beam deflection and multi-casting to two ports. The multi-casting holograms were optimized using a modified Gerchberg-Saxton routine to design the core hologram, followed by a simulated annealing routine to reduce crosstalk at non-switched ports. The effect of clamping the magnitude of phase changes between neighboring pixels during optimization was investigated, with experimental results for multi-casting to two ports resulting in a signal insertion loss of-7.6 dB normalized to single port deflection, a uniformity of ±0.6%, and a worst case crosstalk of-19.4 dB, which can all be improved further by using a better anti-reflection coating on the LCOS SLM coverplate and other measures. © 2013 IEEE.
Resumo:
BACKGROUND: Routine assessment of dry weight in chronic hemodialysis patients relies primarily on clinical evaluation of patient fluid status. We evaluated whether measurement of postdialytic vascular refill could assist in the assessment of dry weight. METHODS: Twenty-eight chronic, stable hemodialysis patients were studied during routine treatment sessions using constant dialysate temperature and dialysate sodium concentration, and relative changes in blood volume were monitored using Crit-Line III monitors throughout this study. The study was divided into three phases. Phase 1 studies evaluated the time-dependence of vascular compartment refill after completion of hemodialysis. Phase 2 studies evaluated the relationships in patient subgroups between intradialytic changes in blood volume and the presence of postdialytic vascular compartment refill during that last 10 minutes of hemodialysis after stopping ultrafiltration. Phase 3 studies evaluated the extent of dry weight changes following the application of a protocol for blood volume reduction, postdialytic vascular compartment refill, and correlation with clinical evidence of intradialytic hypovolemia and/or postdialytic fatigue. Phase 3 included anywhere from three to five treatments. RESULTS: Phase 1 studies demonstrated that despite interpatient variability in the magnitude of postdialytic vascular compartment refill, when significant refill was evident, it always continued for at least 30 minutes. However, the majority of refill took place within 10 minutes postdialysis. Phase 2 studies identified 3 groups of patients: those who exhibited intradialytic reductions in blood volume but not postdialytic vascular compartment refill (group 1), those who exhibited intradialytic reductions in blood volume and postdialytic vascular compartment refill (group 2), and those whose blood volume did not change substantially during hemodialysis treatment (group 3). In phase 3 studies, use of an ultrafiltration protocol for blood volume reduction and monitoring of postdialytic vascular compartment refill combined with clinical assessment of hypovolemia and postdialytic fatigue demonstrated that patients often had a clinical dry weight assessment which was too low or too high. In all 28 patients studied, dry weight was either increased or decreased following use of this protocol. CONCLUSION: Determination of the extent of both intradialytic decreases in blood volume and postdialytic vascular compartment refill, combined with clinical assessment of intradialytic hypovolemia and postdialytic fatigue, can help assess patient dry weight and optimize volume status while reducing dialysis associated morbidity. The number of hospital admissions due to fluid overload may be reduced.