989 resultados para Prosthesis coloring


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of surface glazing and polishing of yttrium-stabilized tetragonal zirconia polycrystal ceramic on early dental biofilm formation, as well as the effect of brushing on the removal of adhered bacteria. Two subjects used oral appliances with polished and glazed samples fixed to the right and left sides. After 20 minutes, 1 hour, and 6 hours, the subjects manually brushed the samples on the right side. The samples were analyzed using scanning electron microscopy. Granular material was verified on the samples, especially on irregular surfaces. After 1 hour, there was no significant difference between glazed and polished surfaces in terms of bacterial presence. However, glazed surfaces tended to accumulate more biofilm, and brushing did not completely remove the biofilm. Polished surfaces seem to present a lower tendency for biofilm formation. Int J Prosthodont 2007;20:419-422.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to compare the microtensile bond strength of resin cement to alumina-reinforced feldspathic ceramic submitted to acid etching or chairside tribochemical silica coating. Ten blocks of Vitadur-α were randomly divided into 2 groups according to conditioning method: (1) etching with 9.6% hydrofluoric acid or (2) chairside tribochemical silica coating. Each ceramic block was luted to the corresponding resin composite block with the resin cement (Panavia F). Next, bar specimens were produced for microtensile testing. No significant difference was observed between the 2 experimental groups (Student t test, P> .05). Both surface treatments showed similar microtensile bond strength values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of surface conditioning methods and thermocycling on the bond strength between a resin composite and an indirect composite system in order to test the repair bond strength. Materials and Methods: Eighteen blocks (5 x 5 x 4 mm) of indirect resin composite (Sinfony) were fabricated according to the manufacturer's instructions. The specimens were randomly assigned to one of the following two treatment conditions (9 blocks per treatment): (1) 10% hydrofluoric acid (HF) for 90 s (Dentsply) + silanization, (2) silica coating with 30-Ìm SiOx particles (CoJet) + silanization. After surface conditioning, the bonding agent was applied (Adper Single Bond) and light polymerized. The composite resin (W3D Master) was condensed and polymerized incrementally to form a block. Following storage in distilled water at 37°C for 24 h, the indirect composite/resin blocks were sectioned in two axes (x and y) with a diamond disk under coolant irrigation to obtain nontrimmed specimens (sticks) with approximately 0.6 mm2 of bonding area. Twelve specimens were obtained per block (N = 216, n = 108 sticks). The specimens from each repaired block were again randomly divided into 2 groups and tested either after storage in water for 24 h or thermocycling (6000 cycles, 5°C to 55°C). The microtensile bond strength test was performed in a universal testing machine (crosshead speed: 1 mm/min). The mean bond strengths of the specimens of each block were statistically analyzed using two-way ANOVA (α = 0.05). Results: Both surface conditioning (p = 0.0001) and storage conditions (p = 0.0001) had a significant effect on the results. After 24 h water storage, silica coating and silanization (method 2) showed significantly higher bond strength results (46.4 ± 13.8 MPa) than that of hydrofluoric acid etching and silanization (method 1) (35.8 ± 9.7 MPa) (p < 0.001). After thermocycling, no significant difference was found between the mean bond strengths obtained with method 1 (34.1 ± 8.9 MPa) and method 2 (31.9 ± 7.9 MPa) (p > 0.05). Conclusion: Although after 24 h of testing, silica coating and silanization performed significantly better in resin-resin repair bond strength, both HF acid gel and silica coating followed by silanization revealed comparable bond strength results after thermocycling for 6000 times.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the microtensile bond strength of a repair composite resin to a leucite-reinforced feldspathic ceramic (Omega 900, VITA) submitted to two surface conditionings methods: 1) etching with hydrofluoric acid + silane application or 2) tribochemical silica coating. The null hypothesis is that both surface treatments can generate similar bond strengths. Ten ceramic blocks (6x6x6 mm) were fabricated and randomly assigned to 2 groups (n=5), according to the conditioning method: G1- 10% hydrofluoric acid application for 2 min plus rinsing and drying, followed by silane application for 30 s; G2- airborne particle abrasion with 30 μm silica oxide particles (CoJet-Sand) for 20 s using a chairside air-abrasion device (CoJet System), followed by silane application for 5 min. Single Bond adhesive system was applied to the surfaces and light cured (40 s). Z-250 composite resin was placed incrementally on the treated ceramic surface to build a 6x6x6 mm block. Bar specimens with an adhesive area of approximately 1 ± 0.1 mm2 were obtained from the composite-ceramic blocks (6 per block and 30 per group) for microtensile testing. No statistically significant difference was observed between G1 (10.19 ± 3.1 MPa) and G2 (10.17 ± 3.1 MPa) (p=0.982) (Student's t test; á = 0.05). The null hypothesis was, therefore, accepted. In conclusion, both surface conditioning methods provided similar microtensile bond strengths between the repair composite resin and the ceramic. Further studies using long-term aging procedures should be conducted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gelfoam® - a biologically resorbable gelatin sponge - has the function of restricting hemorrhage, providing platelet rupture, and supporting fibrin threads. Beriplast® - a fibrinogen-thrombin compound - is used to adhere tissues, to consolidate sutures and in hemostasis. The objective of this study was to perform a histological analysis of the effects of haemostatic agents on osseous repair. These materials were inserted into surgical sites in young rat right and left tibiae. After the observation periods of 7, 14, 30 and 45 days, according to the bioethic protocol, the animals were killed, the tibiae were removed and fixed in 10% formalin and decalcified in equal parts of formic acid and sodium citrate solutions. After routine processing, the specimens were embedded in paraffin for microtomy. Analysis of the results demonstrated that the haemostatic agents are effective in controlling hemorrhage; they stimulate osteogenesis, featuring a pattern of osseous tissue formation similar to the control pattern, although the amount of osseous trabeculae was superior, especially in the Gelfoam group in the periods of 7 and 14 days; 30 days after surgery, the delay in tissue healing in the control group in relation to the experimental groups started to decrease, and the control and experimental groups exhibited similar tissue repair after 45 days, when all the groups exhibited secondary osseous tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the cytotoxic effects of different concentrations of Chlorhexidine (Chx) to the odontoblast cell line MDPC-23. Methods: The odontoblast-like cells were seeded (30,000 cells/cm 2) in 60 wells of 24-well dishes and then incubated in contact with the following experimental and control solutions: Group 1: 0.0024% Chx; Group 2: 0.004% Chx; Group 3: 0.02% Chx; Group 4: Phosphate buffer saline solution (PBS, negative control); and Group 5: 0.06% H 2O 2 (positive control). Cell metabolic activity was measured by MTT assay and the cell morphology was analyzed by SEM. Results: The cytotoxic effects of Chx are dose-dependent. The reduction in the cell metabolism for Groups 1, 2, and 3 was 24.8%, 29.9% and 70.8%, respectively. No statistical difference was observed between the Groups 1 and 2 in which no significant cell morphology changes occurred. Consequently, it was concluded that 0.02% Chx solution presents high cytotoxicity to the odontoblast-like cells MDPC-23. On theother hand, 0.0024% and 0.004% Chx causes slight cytopathic effects to the cultured cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of post surface conditioning on the fatigue resistance of bovine teeth restored with resin-bonded fiber-reinforced composite (FRC). Root canals of 20 single-rooted bovine teeth (16 mm long) were prepared to 12 mm using a preparation drill of a double-tapered fiber post system. Using acrylic resin, each specimen was embedded (up to 3.0 mm from the cervical part of the specimen) in a PVC cylinder and allocated into one of two groups (n = 10) based on the post surface conditioning method: acid etching plus silanization or tribochemical silica coating (30 μm SiOx + silanization). The root canal dentin was etched (H2PO3 for 30 seconds), rinsed, and dried. A multi-step adhesive system was applied to the root dentin and the fiber posts were cemented with resin cement. The specimens were submitted to one million fatigue cycles. After fatigue testing, a score was given based on the number of fatigue cycles until fracture. All of the specimens were resistant to fatigue. No fracture of the root or the post and no loss of retention of the post were observed. The methodology and the results of this study indicate that tribochemical silica coating and acid etching performed equally well when dynamic mechanical loading was used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate in situ, the early bacterial colonization on feldspar-ceramics submitted to different glazing. Methods and Materials: Fourteen standardized disc specimens (diameter: 5 mm, thickness: 1.5 mm) of each of two micro-particulate feldspathic ceramics (VM7 and VM13, Vita) were produced according to manufacturers' specifications for a total of 28 specimens (24 for the analysis of biofilm and 4 for topographic analysis analyzing the ceramic surfaces). Specimens from each type of ceramic were submitted to two different glazing methods composing four groups: VM7 glazed using glazing liquid Vita Akzent® 25 (G1) and glaze firing (G2), VM13 glazed using glazing liquid (G3) and glaze firing (G4). Six individuals (n=6) wore oral appliances with four ceramic specimens, fixed on the buccal face of the appliances. After 8 hours, each sample was evaluated for the presence (1) or absence (0) of bacterial colonization under a scanning electron microscope (SEM) on five randomly selected fields. The value for each sample was cumulative of the results observed in the fields. One sample from each group was evaluated under a SEM to verify the topographic pattern. Results: There was no difference with regard to bacterial colonization between the feldspar-ceramics and between the glazing types (Kruskal-Wallis non-parametric test). Conclusion: Feldspar-ceramics submitted to firing or glaze firing with Vita Akzent® 25 present a similar condition for in situ bacterial colonization. The similar topographic pattern of the ceramic surfaces seems to have influenced the bacterial colonization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pattern of silver nitrate (Ag)-staining differed among testicular lobes of Antiteuchus tripterus. In general, these differences are in regard to the number, size, shape, coloring intensity, and location of the stained bodies or masses, observed during meiosis and spermiogenesis. These characteristics were similar in lobes 1-3. Lobes 4-6, however, differed from each other and from lobes 1-3 as well. Because the Ag-staining method is specific for nucleolar organizing regions and nucleolar material, the observations in meiosis of lobes 1-3 suggested the presence of a single pair of nucleolar organizing region-bearing chromosomes in A. tripterus, as previously found in other Pentatomidae species. In general, the amount of Ag-stained material seen in meiosis of the testicular lobes 1-3 of A. tripterus is smaller than in the other lobes. The differences among lobes observed during spermiogenesis included a striking variation in morphology of the Ag-stained material found in the head and tail of the spermatids. Given that the key role of the nucleolar material is to participate in protein synthesis, interlobular variations seem to be related to the different functions attributed to each lobe (reproduction to lobes 1-3 and basically nutrition to lobes 4-6). To our knowledge, this is the first time that the nucleolar material was studied in each testicular lobe during spermatogenesis. The present observations encourage further studies since, in addition to being of basic biological interest, several Pentatomidae species are agricultural pests and added knowledge of their biology, mainly in reproduction, may be important for the development of control strategies. ©FUNPEC-RP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerous potentially mutagenic chemicals have been studied mainly because they can cause damaging and inheritable changes in the genetic material. Several tests are commonly used for biomonitoring pollution levels and to evaluate the effects of toxic and mutagenic agents present in the natural environment. This study aimed at assessing the potential of a textile effluent contaminated with azo dyes to induce chromosomal and nuclear aberrations in Allium cepa test systems. A continuous exposure of seeds in samples of the textile effluent in different concentrations was carried out (0.3%, 3%, 10%, and 100%). Cells in interphase and undergoing division were examined to assess the presence of chromosome aberrations, nuclear changes, and micronuclei. Our results revealed a mutagenic effect of the effluent at concentrations of 10% and 100%. At lower concentrations, the effluent (3% and 0.3%) did not induce mutagenic alterations in the test organism A. cepa. These findings are of concern, since cell damage may be transmitted to subsequent generations, possibly affecting the organism as a whole, as well as the local biota exposed to the effluent discharge. If the damage results in cell death, the development of the organism may be affected, which could also lead to its death. © 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to analyse denture users' oral care habits with regard to the use of their prostheses. Background: Rehabilitative treatment is only successful when patients are motivated and aware of correct prosthesis use and hygiene. Materials and methods: Questionnaires were distributed to 150 complete denture users at the Federal University of Bahia School of Dentistry, the Esmeralda Natividade Health Center, the Bahian Science Development Foundation and a Salvador nursing home. The questionnaire included information on gender, age, length of prosthesis use, cleaning methods and materials, etc. The data were analysed using EpiInfo version 6 software. The chi-squared test was used for statistical analysis, with a significance level of 5%. Results: Questionnaire results showed that 78% of the subjects, with an average age of 67.3 years, had used the same complete denture for over 5 years. 64% slept with their prostheses and 44% removed them from the mouth only for cleaning. None of the patients interviewed knew anything about brushes designed specifically for complete dentures. 37.3% had a restricted diet and 44% believed that a complete denture would last for more than 10 years. Conclusion: Within the limitations of this study, it was concluded that the edentulous patients surveyed had limited awareness of prosthetic hygiene and long-term oral care despite extended periods of denture use. © 2008 The Authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 24-year-old male patient was the victim of a firearm wound that penetrated the thorax. He arrived at another hospital hemodynamically unstable and was submitted to exploratory surgery by means of bithoracotomy. A lesion of the left branch of the pulmonary artery was detected and successfully repaired. He was submitted for computer-aided tomography on the fifth postoperative day, and a lesion of the mid-thoracic aorta was detected, which formed a saccular image. Considering that the patient had already been submitted to a bithoracotomy and that a direct approach to repair would involve another thoracotomy within a short period of time, endovascular treatment was chosen in our hospital. The procedure was performed under fluoroscopy. A second computer-aided tomography indicated adequate treatment of the lesion, with no indication of an endoleak. He has undergone ambulatory follow-up for 36 months without any problem related to the procedure. While endovascular treatment of the aorta has developed enormously, multicenter studies are needed to better define the long-term results of this approach. © 2008 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.