925 resultados para Power method
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
It is difficult to precisely measure articular arc movement in newborns using a goniometer. This article proposes an objective method based on trigonometry for the evaluation of lower limb abduction. With the newborn aligned in the dorsal decubitus position, 2 points are marked at the level of the medial malleolus, one on the sagittal line and the other at the end of the abduction. Using the right-sided line between these 2 points and a line from the medial malleolus to the reference point at the anterior superior iliac spine or umbilical scar, an isosceles triangle is drawn, and half of the inferential abduction angle is obtained by calculating the sine. Twenty healthy full-term newborns comprise the study cohort. Intersubject and intrasubject variability among the abduction angle values (mean [SD], 37 degrees [4]degrees) is low. This method is advantageous because the measurement is precise and because the sine can be used without approximation.
Resumo:
Aim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.
Resumo:
This work aimed at an evaluation of the classical iodine method for quantification of vitamin C (L-ascorbic acid) in fruit juices, as well as at a search into the stability of this so popular vitamin under different conditions of pH, temperature and light exposition, in addition to a proposal of a new quantification method. Our results point to the persistent reversibility of the blue color of the starch-triiodide complex at the end point when using the classical iodine titration, and the overestimation of the true vitamin concentration in fruit juices. A new quantification method is proposed in order to overcome this problem. Surprising conclusions were obtained regarding the controversial stability of L-ascorbic acid toward atmospheric oxygen, at low pH, even in fruit juice and at room temperature, showing that the major problem concerned with aging of fruit juices is proliferation of microorganisms rather than expontaneous oxidation of L-ascorbic acid.
Resumo:
A nongravimetric acetyl bromide lignin (ABL) method was evaluated to quantify lignin concentration in a variety of plant materials. The traditional approach to lignin quantification required extraction of lignin with acidic dioxane and its isolation from each plant sample to construct a standard curve via spectrophotometric analysis. Lignin concentration was then measured in pre-extracted plant cell walls. However, this presented a methodological complexity because extraction and isolation procedures are lengthy and tedious, particularly if there are many samples involved. This work was targeted to simplify lignin quantification. Our hypothesis was that any lignin, regardless of its botanical origin, could be used to construct a standard curve for the purpose of determining lignin concentration in a variety of plants. To test our hypothesis, lignins were isolated from a range of diverse plants and, along with three commercial lignins, standard curves were built and compared among them. Slopes and intercepts derived from these standard curves were close enough to allow utilization of a mean extinction coefficient in the regression equation to estimate : lignin concentration in any plant, independent of its botanical origin. Lignin quantification by use of a common regression equation obviates the steps of lignin extraction, isolation, and standard curve construction, which substantially expedites the ABL method. Acetyl bromide lignin method is a fast, convenient analytical procedure that may routinely be used to quantify lignin.
Resumo:
At present, the sporadic occurrence of human rabies in Brazil can be attributed primarily to dog- and vampire bat-related rabies viruses. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) was employed as a simultaneous detection method for both rabies field variants within 60 min. Vampire bat-related rabies viruses could be distinguished from dog variants by digesting amplicons of the RT-LAMP reaction using the restriction enzyme Alwl. Amplification and digestion could both be completed within 120 min after RNA extraction. In addition, the RI-LAMP assay also detected rabies virus in isolates from Brazilian frugivorous bats and Ugandan dog, bovine and goat samples. In contrast, there were false negative results from several Brazilian insectivorous bats and all of Chinese dog, pig, and bovine samples using the RI-LAMP assay. This study showed that the RT-LAMP assay is effective for the rapid detection of rabies virus isolates from the primary reservoir in Brazil. Further improvements are necessary so that the RT-LAMP assay can be employed for the universal detection of genetic variants of rabies virus in the field. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Authorised trustee status is a legal concept which has economic implications; one of the major implications is that it assists in the direction of investment funds into particular securities and areas of the economy. The concept of authorised trustee status, while attempting to achieve specific outcomes for the beneficiaries of trusts cannot be relied upon to secure these results. Economic analysis of the role of the trustee maintains that this role is one of portfolio manager; a role which is complex but which is explicable in terms of definable procedures and practices. The role of trustee as portfolio manager is one which requires greater financial knowledge than can be assumed is possessed by all trustees. The trustee as portfolio manager is required to maintain a review of decisions make under powers to invest trust assets. A solution to the problem of authorised trustee status is proposed. The solution takes two parts: the first is the adoption of the prudent person approach but with the codification of duties of the trustee and the explicit listing of the factors that a trustee should consider in using the investment powers. The second part of the proposed solution is to link the investment powers of trustees to the best practice features of securities advisers who are now licensed by a regulatory body, the Australian Securities and Investment Commission.