977 resultados para Performance Studies


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Previous studies with patients diagnosed with Major Depressive Disorder (MDD) revealed deficits in working memory and executive functions. In the present study we investigated whether patients with MDD have the ability to allocate cognitive resources in dual task performance of a highly challenging cognitive task (working memory) and a task that is seemingly automatic in nature (postural control). Method: Fifteen young (18–35 years old) patients with MDD and 24 healthy age-matched controls performed a working memory task and two postural control tasks (standing on a stable or on a moving platform) both separately (single task) and concurrently (dual task). Results: Postural stability under single task conditions was similar in the two groups, and in line with earlier studies, MDD patients recalled fewer working memory items than controls. To equate working memory challenges for patients and controls, task difficulty (number of items presented) in dual task was individually adjusted such that accuracy of working memory performance was similar for the two groups under single task conditions. Patients showed greater postural instability in dual task performance on the stable platform, and more importantly when posture task difficulty increased (moving platform) they showed deficits in both working memory accuracy and postural stability compared with healthy controls. Conclusions: We interpret our results as evidence for executive control deficits in MDD patients that affect their task coordination. In multitasking, these deficits affect not only cognitive but also sensorimotor task performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental static and fatigue tension-tension tests were carried out on 5HS/RTM6 composite intact coupons and coupons incorporating adhesively-bonded (FM300-2) stepped flush joints. The results show that the adhesive joint, which is widely used in repairs, significantly reduces the static strength as well as the fatigue life of the composite. Both, the static and the fatigue failure of the ‘repaired’ coupons occur at the adhesive joint and involve crack initiation and propagation. The latter is modelled using interface finite elements based on the decohezive zone approach. The material degradation in the interface constitutive law is described by a damage variable, which can evolve due to the applied loads as well as the number of fatigue cycles. The fatigue formulation, based on a published model, is adapted to fit the framework of the pseudotransient formulation that is used as a numerical tool to overcome convergence difficulties. The fatigue model requires three material parameters. Numerical tests show that a single set of these parameters can be used to recover, very accurately, the experimental S-N relationship. Sensitivity studies show that the results are not mesh dependent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A plethora of studies have described the in vitro assessment of dissolving microneedle (MN) arrays for enhanced transdermal drug delivery, utilising a wide variety of model membranes as a representation of the skin barrier. However, to date, no discussion has taken place with regard to the choice of model skin membrane and the impact this may have on the evaluation of MN performance. In this study, we have, for the first time, critically assessed the most common types of in vitro skin permeation models - a synthetic hydrophobic membrane (Silescol(®) of 75 µm) and neonatal porcine skin of definable thickness (300-350 µm and 700-750 µm) - for evaluating the performance of drug loaded dissolving poly (methyl vinyl ether co maleic acid) (PMVE/MA) MN arrays. It was found that the choice of in vitro skin model had a significant effect on the permeation of a wide range of small hydrophilic molecules released from dissolving MNs. For example, when Silescol(®) was used as the model membrane, the cumulative percentage permeation of methylene blue 24h after the application of dissolvable MNs was found to be only approximately 3.7% of the total methylene blue loaded into the MN device. In comparison, when dermatomed and full thickness neonatal porcine skin were used as a skin model, approximately 67.4% and 47.5% of methylene blue loaded into the MN device was delivered across the skin 24h after the application of MN arrays, respectively. The application of methylene blue loaded MN arrays in a rat model in vivo revealed that the extent of MN-mediated percutaneous delivery achieved was most similar to that predicted from the in vitro investigations employing dermatomed neonatal porcine skin (300-350 µm) as the model skin membrane. On the basis of these results, a wider discussion within the MN community will be necessary to standardise the experimental protocols used for the evaluation and comparison of MN devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The inference of gene regulatory networks gained within recent years a considerable interest in the biology and biomedical community. The purpose of this paper is to investigate the influence that environmental conditions can exhibit on the inference performance of network inference algorithms. Specifically, we study five network inference methods, Aracne, BC3NET, CLR, C3NET and MRNET, and compare the results for three different conditions: (I) observational gene expression data: normal environmental condition, (II) interventional gene expression data: growth in rich media, (III) interventional gene expression data: normal environmental condition interrupted by a positive spike-in stimulation. Overall, we find that different statistical inference methods lead to comparable, but condition-specific results. Further, our results suggest that non-steady-state data enhance the inferability of regulatory networks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cancer registries must provide complete and reliable incidence information with the shortest possible delay for use in studies such as comparability, clustering, cancer in the elderly and adequacy of cancer surveillance. Methods of varying complexity are available to registries for monitoring completeness and timeliness. We wished to know which methods are currently in use among cancer registries, and to compare the results of our findings to those of a survey carried out in 2006.

Methods
In the framework of the EUROCOURSE project, and to prepare cancer registries for participation in the ERA-net scheme, we launched a survey on the methods used to assess completeness, and also on the timeliness and methods of dissemination of results by registries. We sent the questionnaire to all general registries (GCRs) and specialised registries (SCRs) active in Europe and within the European Network of Cancer Registries (ENCR).

Results
With a response rate of 66% among GCRs and 59% among SCRs, we obtained data for analysis from 116 registries with a population coverage of ∼280 million. The most common methods used were comparison of trends (79%) and mortality/incidence ratios (more than 60%). More complex methods were used less commonly: capture–recapture by 30%, flow method by 18% and death certificate notification (DCN) methods with the Ajiki formula by 9%.

The median latency for completion of ascertainment of incidence was 18 months. Additional time required for dissemination was of the order of 3–6 months, depending on the method: print or electronic. One fifth (21%) did not publish results for their own registry but only as a contribution to larger national or international data repositories and publications; this introduced a further delay in the availability of data.

Conclusions
Cancer registries should improve the practice of measuring their completeness regularly and should move from traditional to more quantitative methods. This could also have implications in the timeliness of data publication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose
This article aims to analyze the role of performance management systems (PMS) in supporting public value strategies.

Design/methodology/approach
This article draws on the public value dynamic model by Horner and Hutton (2010). It presents the results of a case study of implementation of a PMS model, the ‘Value Pyramid’ (VP).

Findings
The results stress the need for an improved conceptualization of PMS within public value strategy. Through experimentation using the VP, the case site was able to measure and visualize what it considered public value and reflect on the internal/external causes of both creation and destruction of public value.

Research limitations/implication
This article is limited to just one case study, although in-depth and longitudinal.

Originality/value
This article is one of the first attempting to understand the role of PMS within the public value strategy framework, answering the call of Benington and Moore (2010) to consider public value from an accounting perspective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the main applications of serum proteomics is the identification of new biomarkers for animal disease or animal production. However, potential obstacles to these studies are the poor performance of affinity serum depletion methods based on human antigens when using animal samples, and loss of minor serum components bound to albumin and other proteins. In the present study, we have analyzed the efficiency and reproducibility of the ProteoMiner® beads with bovine and porcine serum samples, and compared to a traditional immunoaffinity-based albumin and IgG depletion system specific for human samples. The ProteoMiner kit is based on the use of a combinatorial peptide binding library and intends to enrich low-abundance proteins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An endocrine disruptor (ED) is an exogenous compound that interferes with the body's endocrine system. Exposure to EDs may result in adverse health effects such as infertility and cancer. EDs are composed of a vast group of chemicals including compounds of natural origin such as phytoestrogens or mycotoxins and a wide range of man-made chemicals such as pesticides. Synthetic compounds may find their way into the food chain where a number of them can biomagnify. Additionally, processing activities and food contact materials may add further to the already existing pool of food contaminants. Thus, our diet is considered to be one of the main exposure routes to EDs. Some precautionary legislation has already been introduced to control production and/or application of some persistent organic pollutants with ED characteristics. However, newly emerging EDs with bioaccumulative properties have recently been reported to appear at lower tiers of the food chain but have not been monitored at the grander scale. Milk and dairy products are a major component of our diet, thus it is important to monitor them for EDs. However, most methods developed to date are devoted to one group of compounds at a time. The UHPLC-MS/MS method described here has been validated according to EC decision 2002/657/EC and allows simultaneous extraction, detection, quantitation and confirmation of 19 EDs in milk. The method calibration range is between 0.50 and 20.0 μg kg with coefficients of determination above 0.99 for all analytes. Precision varied from 4.7% to 23.4% in repeatability and reproducibility studies. Established CCα and CCβ values (0.11-0.67 μg kg) facilitate fast, reliable, quantitative and confirmatory analysis of sub μg kg levels of a range of EDs in milk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design and VLSI implementation of two key components of the class-IV partial response maximum likelihood channel (PR-IV) the adaptive filter and the Viterbi decoder are described. These blocks are implemented using parameterised VHDL modules, from a library of common digital signal processing (DSP) and arithmetic functions. Design studies, based on 0.6 micron 3.3V standard cell processes, indicate that worst case sampling rates of 49 mega-samples per second are achievable for this system, with proportionally high sampling rates for full custom designs and smaller dimension processes. Significant increases in the sampling rate, from 49 MHz to approximately 180 MHz, can be achieved by operating four filter modules in parallel, and this implementation has 50% lower power consumption than a pipelined filter operating at the same speed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Building Information Modelling (BIM) is growing in pace, not only in design and construction stages, but also in the analysis of facilities throughout their life cycle. With this continued growth and utilisation of BIM processes, comes the possibility to adopt such procedures, to accurately measure the energy efficiency of buildings, to accurately estimate their energy usage. To this end, the aim of this research is to investigate if the introduction of BIM Energy Performance Assessment in the form of software analysis, provides accurate results, when compared with actual energy consumption recorded. Through selective sampling, three domestic case studies are scrutinised, with baseline figures taken from existing energy providers, the results scrutinised and compared with calculations provided from two separate BIM energy analysis software packages. Of the numerous software packages available, criterion sampling is used to select two of the most prominent platforms available on the market today. The two packages selected for scrutiny are Integrated Environmental Solutions - Virtual Environment (IES-VE) and Green Building Studio (GBS). The results indicate that IES-VE estimated the energy use in region of ±8% in two out of three case studies while GBS estimated usage approximately ±5%. The findings indicate that the introduction of BIM energy performance assessment, using proprietary software analysis, is a viable alternative to manual calculations of building energy use, mainly due to the accuracy and speed of assessing, even the most complex models. Given the surge in accurate and detailed BIM models and the importance placed on the continued monitoring and control of buildings energy use within today’s environmentally conscious society, this provides an alternative means by which to accurately assess a buildings energy usage, in a quick and cost effective manner.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Since the publication of the 2006 American College of Chest Physicians (CHEST) cough guidelines, a variety of tools has been developed or further refined for assessing cough. The purpose of the present committee was to evaluate instruments used by investigators performing clinical research on chronic cough. The specific aims were to (1) assess the performance of tools designed to measure cough frequency, severity, and impact in adults, adolescents, and children with chronic cough and (2) make recommendations or suggestions related to these findings.

METHODS: By following the CHEST methodologic guidelines, the CHEST Expert Cough Panel based its recommendations and suggestions on a recently published comparative effectiveness review commissioned by the US Agency for Healthcare Research and Quality, a corresponding summary published in CHEST, and an updated systematic review through November 2013. Recommendations or suggestions based on these data were discussed, graded, and voted on during a meeting of the Expert Cough Panel.

RESULTS: We recommend for adults, adolescents (≥ 14 years of age), and children complaining of chronic cough that validated and reliable health-related quality-of-life (QoL) questionnaires be used as the measurement of choice to assess the impact of cough, such as the Leicester Cough Questionnaire and the Cough-Specific Quality-of-Life Questionnaire in adult and adolescent patients and the Parent Cough-Specific Quality of Life Questionnaire in children. We recommend acoustic cough counting to assess cough frequency but not cough severity. Limited data exist regarding the performance of visual analog scales, numeric rating scales, and tussigenic challenges.

CONCLUSIONS: Validated and reliable cough-specific health-related QoL questionnaires are recommended as the measurement of choice to assess the impact of cough on patients. How they compare is yet to be determined. When used, the reporting of cough severity by visual analog or numeric rating scales should be standardized. Previously validated QoL questionnaires or other cough assessments should not be modified unless the new version has been shown to be reliable and valid. Finally, in research settings, tussigenic challenges play a role in understanding mechanisms of cough.