971 resultados para Nitrogen and phosphorous loading
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper discusses the results of biodegradability tests of natural fibers used by the automotive industry, namely: coir, coir with latex, and sisal. The biodegradation of coir, coir with latex, and of sisal fibers was determined by monitoring the production of carbon dioxide (CO(2)) (IBAMA-E.1.1.2, 1988) and fungal growth (DIN 53739, 1984). The contents of total extractives, lignin, holocellulose, ashes, carbon, nitrogen and hydrogen of the fibers under study were determined in order to ascertain their actual content and to understand the results of the biodegradation tests. The production of CO(2) indicated low biodegradation, i.e., about 10% in mass, for all the materials after 45 days of testing; in other words, no material inhibited glucose degradation. However, the percentage of sisal fiber degradation was fourfold higher than that of coir with latex in the same period of aging. The fungal growth test showed a higher growth rate on sisal fibers, followed by coir without latex. In the case of coir with latex, we believe the fungal growth was not intense, because natural latex produces a bactericide or fungicide for its preservation during bleeding [1]. An evaluation of the materials after 90 days of aging tests revealed breaking of the fibers, particularly sisal and coir without latex, indicating fungal attack and biodegradation processes.
Resumo:
A germinação das sementes de grão-de-bico foi acompanhada por um período de 6 dias, no qual pequenas variações nos teores de nitrogênio e globulina total foram registradas. A globulina majoritária (tipo 11 S) apresentou maiores variações após o quarto dia de germinação. A natureza e distribuição da fração globulina majoritária isolada na cromatografia em Sepharose CL-6B mostrou pequenas modificações ao final do período de germinação. A eletroforese em gel de poliacrilamida com dodecilssulfato de sódio do pico eluído na cromatografia em Sepharose CL-6B demonstra modificações nas bandas de proteínas entre os pesos moleculares de 20 e 30 kDa e acima de 60 kDa, indicando degradação protéica durante o período. Atividade proteolítica foi detectada na fração albumina da semente que aumentou até o quarto dia, seguido de queda até o sexto dia de germinação, quando da utilização de globulina total isolada da semente e caseína como substratos. Farinha de grão-de-bico, frações albumina e globulina total isoladas não apresentaram aumento na digestibilidade in vitro; entretanto, a fração globulina majoritária isolada foi mais suscetível à hidrólise após germinação.
Resumo:
A new class of hybrid ruteno-cuprates - such as Ru-1212 and Ru-1222 - was discovered in 1995 by Bauerfeind and collaborators. These materials present superconducting and magnetic states at low temperatures, an atypical duality in other superconductors. The superconductivity is more easily observed in Ru-1222, while Ru-1212 is a more problematic case, due to the strong effects of the preparation details in its superconducting properties, becoming the material superconductor or not. Ru-1212 presents a critical temperature that can vary between 0 and 46 K, depending on the preparation conditions, and a temperature of magnetic transition of around 132 K. The samples were prepared through solid state reactions, by using a mixture of high purity powders, followed by calcination and sinterization in the nitrogen and oxygen atmospheres. This paper shows the preparation process of Ru-1212 samples, followed by their structural and magnetic characterization.
Resumo:
In this work, an investigation was conducted on amorphous hydrogenated-nitrogenated carbon films prepared by plasma immersion ion implantation and deposition. Glow discharge was excited by radiofrequency power (13.56 MHz, 40 W) whereas the substrate-holder was biased with 25 kV negative pulses. The films were deposited from benzene, nitrogen and argon mixtures. The proportion of nitrogen in the chamber feed (R-N) was varied against that of argon, while keeping the total pressure constant (1.3 Pa). From infrared reflectance-absorbance spectroscopy it was observed that the molecular structure of the benzene is not preserved in the film. Nitrogen was incorporated from the plasma while oxygen arose as a contaminant. X-ray photoelectron spectroscopy revealed that N/C and O/C atomic ratios change slightly with R-N. Water wettability decreased as the proportion of N in the gas phase increased while surface toughness underwent just small changes. Nanoindentation measurements showed that film deposition by means of ion bombardment was beneficial to the mechanical properties of the film-substrate interface. The intensity of the modifications correlates well with the degree of ion bombardment. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Silicon carbide (SiC) has been employed in many different fields such as ballistic armor, thermal coating, high performance mirror substrate, semiconductors devices, among other things. Plasma application over the silicon carbide ceramics is relatively recent and it is able to promote relevant superficial modifications. Plasma expander was used in this work which was supplied by nitrogen and switched by a capacitor bank. Nitrogen plasma was applied over ceramic samples for 20 minutes, in a total medium of 1440 plasma pulses. SiC ceramics were produced by uniaxial pressing method (40 MPa) associated to isostatic pressing (300 MPa) and sintered at 1950 degrees C under argon gas atmosphere. Silicon carbide (beta-sic - BF-12) supplied by HC-Starck and sintering additive (7.6% YAG - Yttrium Aluminum Garnet) were used in order to obtain the ceramics. Before and after the plasma application, the samples were characterized by SEM, AFM, contact angle and surface energy measurement.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study describes the influence of incubation temperature during initial development phase on the morphology and muscle growth characteristics in the pacu (Piaractus mesopotamicus). Pacu eggs were incubated at 25, 27, and 29 degreesC until hatching. After day 5, fish from each temperature were transferred to 5001 tanks. At hatching and after 5, 25, and 60 days, muscle samples were collected, some were frozen in liquid nitrogen and others fixed in 4% paraformaldehyde or 2.5% glutaraldehyde. These samples were used for morphological, histochemical, immunohistochemical, and morphometric analysis. At hatching, we observed a superficial monolayer of small diameter fibers, lying just beneath the skin surrounding several round cells. From day 5, we observed two distinct populations of muscle fibers distributed in two layers: (1) red-in a superficial region with aerobic activity, and following acid preincubation, high mATPase activity, and 2) white-with anaerobic activity, and following alkaline preincubation, high mATPase activity. Twenty-five days after hatching, an intermediate layer and cell proliferating zones could be seen in the dorsal fin muscle region, with intermediate characteristics. Throughout the experimental period, there was an increase in muscle mass due to new fiber recruitment in the cell proliferating zones and between the more differentiated fibers in red, intermediate, and white muscles. This was more obvious from day 25, and at 29 degreesC than at 25 and 27 degreesC. Fiber hypertrophy occurred from hatching to 60 days and was more evident from 5 to 25 days. The number of proliferating nuclei (PCNA-labelling) increased from hatching to 60 days, and was more obvious in the 29 degreesC group at 60 days. Our results show that at incubation temperatures of 25, 27 and 29 degreesC, hypertrophy was predominantly from hatching to 25 days, after that muscle growth by hyperplastic mechanism increased. The interaction of muscle hypertrophic and hyperplastic growth processes in the 29 degreesC group produced the largest fish at the end of the experiment. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Purpose: Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Materials and Methods: Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 x 10(6) cycles was defined. Group means were calculated and compared using analysis of variance and the F test (alpha=.05). Results: Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P=.021). After cyclic loading, there was no significant difference between them (P=.499). Conclusions: Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1061-1067
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Physical and chemical characteristics of sediment were analyzed at eight sampling areas in the estuarine region of Cananeia (SP), Brazil. The samples were collected in 1995 during four periods; summer, autumn, winter and spring. Total nitrogen and phosphorus concentrations, redox potential, water and organic matter percentage, sand and silt percentage and grain size were determined in six different layers of 20 cm deep columns of sediment. In general, the nutrient concentration and the percentage of organic matter decreased with depth and greater variations were observed in the first centimeter of the samples. Differences in nutrient concentration and organic matter were also observed during the study period. The highest concentrations were recorded during the rainy season (February) as a consequence of an accumulation of organic matter brought into the system by rivers and adjacent flooded areas. In general, the sediments had oxidized characteristics until the 5 or 10 cm depth in areas near the rich coastal vegetation. However, in areas open to the ocean, the entire sediment columns were almost completely oxidized.
Resumo:
Elemental composition and spectroscopic properties (FT-IR and CP/MAS C-13-NMR) of sedimentary humic substances (HS) from aquatic subtropical environments (a lake, an estuary and two marine sites) are investigated. Humic acids (HA) are relatively richer in nitrogen and in aliphatic chains than fulvic acids (FA) from the same sediments. Conversely, FA are richer in carboxylic groups and in ring polysaccharides than HA. Nitrogen is mostly present as amide groups and for lake and marine HS the FT-IR peaks around 1640 cm(-1) and 1540 cm(-1) identify polypeptides. Estuarine HS exhibit mixed continental-marine influences, these being highly influenced by site location. Overall, the data suggest that aquatic and mixed HS are more aliphatic than has been proposed in current models and also that amide linkages form an important part of their structural configuration.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)