890 resultados para Hip
Resumo:
It is known that the method used to mix the liquid monomer and powder of PMMA bone cement influences the quality of the cement that is used in total joint replacements. Mixing theory indicates that the interaction between the liquid monomer and the powder is affected by a number of parameters, such as cement viscosity and degree of agitation, with this knowledge utilized in the design of cement mixing devices. Therefore, the objectives of this study were to: (i) obtain information on the interaction of the liquid monomer and the powder in the case of an PMMA bone cement, (ii) show how this knowledge can be applied to the design of an automated cement mixing device, and (iii) compare the porosity, bending modulus, and bending strength of one commercially-available cement prepared using the automated mixer and prepared using a conventional mixer that is in current clinical use. Experimental data indicated that increasing the velocity and decreasing the viscosity of the systems produced cement that improved mechanical properties, which may contribute to better mechanical integrity and, hence, reduced tendency for aseptic loosening, of cemented hip implants.
Resumo:
Aim. This paper is a presentation of a study protocol to establish the prevalence of orthopaedic problems (hip dislocation, pelvic obliquity, spinal deformity and contractures) and their impact on pain, function, participation and health in a population of children and young people with severe cerebral palsy.
Background. Cerebral palsy is the commonest cause of motor impairment in childhood and is associated with life-long disability. An estimated 30% of people with cerebral palsy have severe forms and are non-ambulant. Although the underlying neurological damage is not amenable to correction, many health services are dedicated to providing therapeutic and adaptive support to help people with the condition reach their potential.
Method. A cross-sectional survey of children and young people, aged 4–25 years with severe, non-ambulant cerebral palsy as defined using the Gross Motor Function Classification System (Levels IV and V). Study participants will be identified from a pre-existing, geographically defined case register and recruited via a healthcare professional known to them. Two assessments will be undertaken: one involving parents/carers at home and using questionnaires; the other involving the child/young person ideally in one of three settings and including X-rays if clinically indicated.
Discussion. This study will contribute to our knowledge of the history and epidemiology of orthopaedic problems in children and young people with cerebral palsy and how these problems accumulate and impact on participation, health and well-being. The study will also identify unmet need and make recommendations for good practice in relation to the orthopaedic care and management for people with severe cerebral palsy
Resumo:
This paper describes an example of spontaneous transitions between qualitatively different coordination patterns during a cyclic lifting and lowering task. Eleven participants performed 12 trials of repetitive lifting and lowering in a ramp protocol in which the height of the lower shelf was raised or lowered I cm per cycle between 10 and 50 cm. Two distinct patterns of coordination were evident: a squat technique in which moderate range of hip, knee and ankle movement was utilised and ankle plantar-flexion occurred simultaneously with knee and hip extension; and a stoop technique in which the range of knee movement was reduced and knee and hip extension was accompanied by simultaneous ankle dorsi-flexion. Abrupt transitions from stoop to squat techniques were observed during descending trials, and from squat to stoop during ascending trials. Indications of hysteresis was observed in that transitions were more frequently observed during descending trials, and the average shelf height at the transition was 5 cm higher during ascending trials. The transitions may be a consequence of a trade-off between the biomechanical advantages of each technique and the influence of the lift height on this trade-off. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
We recently described a sonication technique for the diagnosis of prosthetic knee and hip infections. We compared periprosthetic tissue culture to implant sonication followed by sonicate fluid culture for the diagnosis of prosthetic shoulder infection. One hundred thirty-six patients undergoing arthroplasty revision or resection were studied; 33 had definite prosthetic shoulder infections and 2 had probable prosthetic shoulder infections. Sonicate fluid culture was more sensitive than periprosthetic tissue culture for the detection of definite prosthetic shoulder infection (66.7 and 54.5%, respectively; P = 0.046). The specificities were similar (98.0% and 95.1%, respectively; P = 0.26). Propionibacterium acnes was the commonest species detected among culture-positive definite prosthetic shoulder infection cases by periprosthetic tissue culture (38.9%) and sonicate fluid culture (40.9%). All subjects from whom P. acnes was isolated from sonicate fluid were male. We conclude that sonicate fluid culture is useful for the diagnosis of prosthetic shoulder infection.
Resumo:
La investigación sobre el graffiti relacionado con el arte urbano, el diseño y la comunicación visual, la cultura social y política en la ciudad de Bogotá, son temas que concentran esta investigación. Opiniones y entrevistas fueron revelando la influencia sobre la comunidad, la sociedad civil, la política, y el enfrentamiento radical con la leyes, su clasificación y su exigencia según el estrato social han hecho de los espacios públicos de Bogotá una ciudad con paredes hablantes. Aunque no es tomado como algo malo, -para algunos- vandalismo para otros, despierta en muchos, opiniones diversas y sobre todo una subestimada valoración de los artistas hacia una expresión liberal y democrática de un sistema que los aleja de cualquier exhibición del arte tradicional.
Resumo:
Multiple osteochondromas is an inherited autosomal dominant condition of enchondral bone growth. The paper undertakes the first synthesis study of the 16 known cases of the condition that have been identified in the international palaeopathological record. It also includes information derived from two newly discovered cases of the disease in two adult male individuals recovered from the Medieval cemetery at Ballyhanna, Co. Donegal, Ireland. The formation of multiple osteochondromas is the best known characteristic of the disease but it also involves the development of a suite of orthopaedic deformities. These deformities, which include disproportionate short stature, inequality of bone length, forearm deformities, tibiofibular diastasis, coxa valga of the hip and valgus deformity of the knee and ankle, are discussed in relation to the archaeological cases. Numerous synonyms for the disease have been used within the various publications produced by palaeopathologists, and this can generate confusion among readers. As such, the paper recommends that in future palaeopathologists should follow the guidance of the World Health Organization and use the term multiple osteochondromas when discussing the disease.
Resumo:
Research has focused on in vitro expansion of bone marrow stromal cells with the aim of developing cell-based therapies or tissue-engineered constructs. There is debate over whether there is a reduction in stem cells/osteoprogenitors in the bone marrow compartment with increasing age. The aim of this study was to investigate patient factors that affect the progenitor pool in bone marrow samples. Six milliliters of marrow aspirate was obtained from the femoral canal of 38 primary hip replacement patients (aged 28-91). Outcome measures were total nucleated cell count, colony-forming efficiency, alkaline phosphatase expression, and expression of stem cell markers. There was a nonsignificant negative correlation between age and both colony-forming efficiency and stem cell marker expression. However, body mass index showed a positive, significant correlation with colony area and number in men-accounting for up to 75% of the variation. In conclusion, body mass index, not age, was highly predictive of the number of progenitors found in bone marrow, and this relationship was sex specific. These results may inform the clinician's treatment choice when considering bone marrow-based therapies. Further, it highlights the need to widen research into patient factors that affect the adult stem cell population beyond age and reinforces the need to consider sexes separately.
Resumo:
The majority of cemented femoral hip replacements fail as a consequence of loosening. One design feature that may affect loosening rates is implant surface finish. To determine whether or not surface finish effects fatigue damage accumulation in a bone cement mantle, we developed an experimental model of the implanted proximal femur that allows visualisation of damage growth in the cement layer. Five matt surface and five polished surface stems were tested. Pre-load damage and damage after two million cycles was measured. Levels of pre-load (shrinkage) damage were the same for both matt and polished stems; furthermore damage for matt vs. polished stems was not significantly different after two million cycles. This was due to the large variability in damage accumulation rates. Finite element analysis showed that the stress is higher for the polished (assumed debonded) stem, and therefore we must conclude that either the magnitude of the stress increase is not enough to appreciably increase the damage accumulation rate or, alternatively, the polished stem does not debond immediately from the cement. Significantly (P = 0.05) more damage was initiated in the lateral cement compared to the medial cement for both kinds of surface finish. It was concluded that, despite the higher cement stresses with debonded stems, polished prostheses do not provoke the damage accumulation failure scenario. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.
Resumo:
Residual stress due to shrinkage of polymethylmethacrylate bone cement after polymerisation is possibly one factor capable of initiating cracks in the mantle of cemented hip replacements. No relationship between residual stress and observed cracking of cement has yet been demonstrated. To investigate if any relationship exists, a physical model has been developed which allows direct observation of damage in the cement layer on the femoral side of total hip replacement. The model contains medial and lateral cement layers between a bony surface and a metal stem; the tubular nature of the cement mantle is ignored. Five specimens were prepared and examined for cracking using manual tracing of stained cracks, observed by transmission microscopy: cracks were located and measured using image analysis. A mathematical approach for the prediction of residual stress due to shrinkage was developed which uses the thermal history of the material to predict when stress-locking occurs, and estimates subsequent thermal stress. The residual stress distribution of the cement layer in the physical model was then calculated using finite element analysis. Results show maximum tensile stresses normal to the observed crack directions, suggesting a link between residual stress and preload cracking. The residual stress predicted depends strongly on the definition of the reference temperature for stress-locking. The highest residual stresses (4-7 MPa) are predicted for shrinkage from maximum temperature, in this case, magnitudes are sufficiently high to initiate cracks when the influence of stress raisers such as pores or interdigitation at the bone/cement interface are taken into account (up to 24 MPa when calculating stress around a pore according to the method of Harrigan and Harris (J. Biomech. 24(11) (1991) 1047-1058)). We conclude that the damage accumulation failure scenario begins before weight-bearing due to cracking induced by residual stress around pores or stress raisers. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Stress analysis of the cement fixation of orthopaedic implants to bone is frequently? carried out using finite element analysis. However, the stress distribution in the cement laver is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stein tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However; if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stein generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stein. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.
Resumo:
Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty.
A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant–cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration.
Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.
Resumo:
Background:Research examining the relationship between adiponectin (AN) isoforms, body weight and cardiovascular (CV) risk factors is limited, particularly in younger populations. Objectives:To investigate the inter-relationships between AN isoforms and CV risk factors, and their dependence on body weight status, in adolescents. Design:Blood samples from 92 obese, 92 overweight and 92 normal weight age- and sex-matched adolescents were analysed for traditional cardiovascular disease (CVD) risk biomarkers and also total, high molecular weight (HMW), medium and low molecular weight (LMW) AN. Results:A significant inverse association was observed between total and HMW AN and waist-hip ratio (P=0.015, P=0.006, respectively), triglycerides (P=0.003, P=0.003, respectively) and systolic blood pressure (P=0.012, P=0.024, respectively) and a significant positive association with high-density lipoprotein (P<0.001, P<0.001, respectively) in multi-adjusted analyses. There was no evidence of a relationship between multimeric AN and high-sensitivity C-reactive protein. There was also little evidence of a relationship between LMW AN and CVD risk factors. There was a strong, body mass index (BMI)-independent, association between AN, CVD biomarkers and the hypertriglyceridemic waist phenotype. Conclusion:Prominent, BMI-independent associations between total and HMW AN, but not LMW AN, and CVD risk factors were already evident in this young population. This research in adolescents supports the contention that AN subfractions may have different biological actions. These associations in apparently healthy adolescents suggest an important role for AN and its subfractions in the pathogenesis of metabolic syndrome traits and indicate that the potential for total or HMW AN to act as early universal biomarkers of CV risk warrants further study.
Resumo:
Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct.
Resumo:
We report a series of 706 patients (759 hip implants) with an average follow up of 10.5 years (range, 10-11 years) following total hip replacement (THR) using a cemented custom-made femoral stem and a cemented HDP acetabular component. The fate of every implant is known. One hundred and seventy-four patients (23%) were deceased at the time of their 10-year review all died with a functioning THR in situ. Four hundred and sixty-two patients (61%) were subsequently reviewed. One hundred and twenty three patients (16%) were assessed by telephone review, as they were too ill or unwilling to attend. Kaplan-Meier survival analysis (all components) demonstrated a median survival at 10 years of 96.05% or 95% Confidence Intervals (CI) for median survival of (94.41% to 97.22%). Revision surgery occurred in 30 cases (3.9%). Seventeen had full revisions (2.2%) and 13 (1.7%) socket revisions only. Twenty-one out of 30 revisions were for infection or dislocation. There were 2 cases (0.3%) of revision for aseptic loosening of the stem. The 10-year results of the custom femoral titanium stem are encouraging and compare well with other cemented systems.