966 resultados para FINE PARTICULATE MATTER
Resumo:
The TetraEther indeX of 86 carbon atoms (TEX86) temperature proxy is widely used in reconstructions of past sea surface temperature. Most current calibrations are based on surface sediment distributions of the glycerol dialkyl glycerol tetraether lipids (GDGTs) that comprise TEX86 and assume that these GDGTs are exported from the upper mixed layer. However, GDGT export from deeper waters could impact sedimentary GDGT distributions and therefore TEX86 paleothermometry. Here we examine GDGT distributions in suspended particulate matter (SPM) and underlying sediments collected from the Southeast Atlantic Ocean. Our results reveal different GDGT distributions - specifically the ratio between GDGTs bearing 2 vs. 3 cyclopentyl moieties, [2/3] ratios - between surface, subsurface (>50-200 m) and deep water (>200 m) SPM, which suggests the occurrence of in situ (deep) production that is not apparent when considering TEX86. The GDGT distributions in sediments match those of subsurface waters rather than surface waters, suggesting that they have not been preferentially derived from the upper mixed layer; this is consistent with GDGT abundances being highest in shallow subsurface SPM (˜100 to 200 m). It remains unclear what governs the different [2/3] ratios throughout the water column, but it is likely related to a combination of temperature and thaumarchaeotal community structure.
Resumo:
Within models, zooplankton grazing is typically defined as being dependent on total prey concentration, with feeding selectivity expressed only as a function of prey size. This behavior ignores taxonomic preferences shown by the preda- tors and the capacity of some zooplankton to actively select or reject individual prey items from mixtures. We carried out two model experiments comparing impacts of zooplankton displaying passive and active selection, which resulted in contrasting dynamics for the pelagic system. Passive selection by the grazer resulted in a top down control on the prey with a fast turn-over of nutrients. Active selection, on the other hand led to a bottom-up control, with slower nutrient turnover constraining primary production by changing the system toward export of particulate matter. Our results suggest that selective feeding behavior is an important trait, and should be considered alongside size and taxonomy when studying the role of zooplankton impact in the ecosystem.
Resumo:
Xanthoria parietina, common foliose lichen, growing in its natural habitat, was analysed for the concentration of five heavy metals (Fe, Cr, Zn, Pb and Cu) from different forest sites of North East of Morocco (Kenitra, Sidi Boughaba, Mkhinza, Ceinture Verte near Temara city, Skhirate, Bouznika and Mohammedia). The quantification was carried out by inductively coupled plasma - atomic emission spectrometry (ICP-AES). Results were highly significant p<0,001. The concentration of metals is correlated with the vehicular activity and urbanization. The total metal concentration is highest at the Kenitra area, followed by Ceinture Verte site near Temara city, which experience heavy traffic throughout the year. Scanning electron microscopy (SEM) of particulate matter on lichen of Xanthoria parietina was assessed as a complementary technique to wet chemical analysis for source apportionment of airborne contaminant. Analysis revealed high level of Cu, Cr, Zn and Pb in samples near roads.
Resumo:
The rate of uptake of Endosulfan by Mytilus edulis L. exposed to pesticide concentrations of 0.1, 0.5, and 1.0 mg/l, and its subsequent elution on removal to clean sea water, was investigated. Higher residue levels were recorded for mussels exposed to higher concentrations of the pesticide, but concentration factors were reduced. There was a rapid initial fall in tissue residue levels on transfer to clean sea water due, it is suggested, to elution of Endosulfan adsorbed on particulate matter assimilated in the gut. The spawning period was prolonged at higher concentrations and, at 1.0 mg/l, the onset of spawning was delayed, possibly due to interference with gamonic action. At 0.1 mg/l, the minor protraction of the spawning period may reflect the effect of experimental tank conditions. No seasonal trend was obvious, and there was an exaggeration of the expected fall in condition in mussels exposed to higher concentrations of Endosulfan. In controls, the expected seasonal trend was reduced.
Resumo:
Background: In this study, the efficiency of Guar gum as a biopolymer has been compared with two other widely used inorganic coagulants, ferric chloride (FeCl3) and aluminum chloride (AlCl3), for the treatment of effluent collected from the rubber-washing tanks of a rubber concentrate factory. Settling velocity distribution curves were plotted to demonstrate the flocculating effect of FeCl3, AlCl3 and Guar gum. FeCl3 and AlCl3 displayed better turbidity removal than Guar gum at all settling velocities.
Result: FeCl3, AlCl3 and Guar gum removed 92.8%, 88.2% and 88.1% turbidity, respectively, of raw wastewater at a settling velocity of 0.1 cm min-1, respectively. Scanning electron microscopic (SEM) study conducted on the flocs revealed that Guar gum and FeCl3produced strong intercoiled honeycomb patterned floc structure capable of entrapping suspended particulate matter. Statistical experimental design Response Surface Methodology (RSM) was used to design all experiments, where the type and dosage of flocculant, pH and mixing speed were taken as control factors and, an optimum operational setting was proposed.
Conclusion: Due to biodegradability issues, the use of Guar gum as a flocculating agent for wastewater treatment in industry is highly recommended.
Resumo:
Solid particle erosion is a major concern in the engineering industry, particularly where transport of slurry flow is involved. Such flow regimes are characteristic of those in alumina refinement plants. The entrainment of particulate matter, for example sand, in the Bayer liquor can cause severe erosion in pipe fittings, especially in those which redirect the flow. The considerable costs involved in the maintenance and replacement of these eroded components led to an interest in research into erosion prediction by numerical methods at Rusal Aughinish alumina refinery, Limerick, Ireland, and the University of Limerick. The first stage of this study focused on the use of computational fluid dynamics (CFD) to simulate solid particle erosion in elbows. Subsequently an analysis of the factors that affect erosion of elbows was performed using design of experiments (DOE) techniques. Combining CFD with DOE harnesses the computational power of CFD in the most efficient manner for prediction of elbow erosion. An analysis of the factors that affect the erosion of elbows was undertaken with the intention of producing an erosion prediction model. © 2009 Taylor & Francis.
Resumo:
Traditional internal combustion engine vehicles are a major contributor to global greenhouse gas emissions and other air pollutants, such as particulate matter and nitrogen oxides. If the tail pipe point emissions could be managed centrally without reducing the commercial and personal user functionalities, then one of the most attractive solutions for achieving a significant reduction of emissions in the transport sector would be the mass deployment of electric vehicles. Though electric vehicle sales are still hindered by battery performance, cost and a few other technological bottlenecks, focused commercialisation and support from government policies are encouraging large scale electric vehicle adoptions. The mass proliferation of plug-in electric vehicles is likely to bring a significant additional electric load onto the grid creating a highly complex operational problem for power system operators. Electric vehicle batteries also have the ability to act as energy storage points on the distribution system. This double charge and storage impact of many uncontrollable small kW loads, as consumers will want maximum flexibility, on a distribution system which was originally not designed for such operations has the potential to be detrimental to grid balancing. Intelligent scheduling methods if established correctly could smoothly integrate electric vehicles onto the grid. Intelligent scheduling methods will help to avoid cycling of large combustion plants, using expensive fossil fuel peaking plant, match renewable generation to electric vehicle charging and not overload the distribution system causing a reduction in power quality. In this paper, a state-of-the-art review of scheduling methods to integrate plug-in electric vehicles are reviewed, examined and categorised based on their computational techniques. Thus, in addition to various existing approaches covering analytical scheduling, conventional optimisation methods (e.g. linear, non-linear mixed integer programming and dynamic programming), and game theory, meta-heuristic algorithms including genetic algorithm and particle swarm optimisation, are all comprehensively surveyed, offering a systematic reference for grid scheduling considering intelligent electric vehicle integration.
Resumo:
In COPD inflammation driven by exposure to tobacco smoke results in impaired innate immunity in the airway and ultimately to lung injury and remodeling. To understand the biological processes involved in host interactions with cigarette derived toxins submerged epithelial cell culture is widely accepted as a model for primary human airway epithelial cell culture research. Primary nasal and bronchial epithelial cells can also be cultured in air-liquid interface (ALI) models. ALI and submerged culture models have their individual merits, and the decision to use either technique should primarily be determined primarily by the research hypothesis.
Cigarette smoke has gaseous and particulate matter, the latter constituent primarily represented in cigarette smoke extract (CSE). Although not ideal in order to facilitate our understanding of the responses of epithelial cells to cigarette smoke, CSE still has scientific merit in airway cell biology research. Using this model, it has been possible to demonstrate differences in levels of tight junction disruption after CSE exposure along with varied vulnerability to the toxic effects of CSE in cell cultures derived from COPD and control study groups.
Primary nasal epithelial cells (PNECs) have been used as an alternative to bronchial epithelial cells (PBECs). However, at least in subjects with COPD, PNECs cannot consistently substitute for PBECs. Although airway epithelial cells from patients with COPD exhibit a constitutional pro-inflammatory phenotype, these cells have a diminished inflammatory response to CSE exposure. COPD epithelial cells have an increased susceptibility to undergo apoptosis, and have reduced levels of Toll-like receptor-4 expression after CSE exposure, both of which may account for the reduced inflammatory response observed in this group.
The use of CSE in both submerged and ALI epithelial cultures has extended our understanding of the cellular mechanisms that are important in COPD, and helped to unravel important pathways which may be of relevance in its pathogenesis.
Resumo:
In Portugal, it was estimated that around 1.95 Mton/year of wood is used in residential wood burning for heating and cooking. Additionally, in the last decades, burnt forest area has also been increasing. These combustions result in high levels of toxic air pollutants and a large perturbation of atmospheric chemistry, interfere with climate and have adverse effects on health. Accurate quantification of the amounts of trace gases and particulate matter emitted from residential wood burning, agriculture and garden waste burning and forest fires on a regional and global basis is essential for various purposes, including: the investigation of several atmospheric processes, the reporting of greenhouse gas emissions, and quantification of the air pollution sources that affect human health at regional scales. In Southern Europe, data on detailed emission factors from biomass burning are rather inexistent. Emission inventories and source apportionment, photochemical and climate change models use default values obtained for US and Northern Europe biofuels. Thus, it is desirable to use more specific locally available data. The objective of this study is to characterise and quantify the contribution of biomass combustion sources to atmospheric trace gases and aerosol concentrations more representative of the national reality. Laboratory (residential wood combustion) and field (agriculture/garden waste burning and experimental wildland fires) sampling experiments were carried out. In the laboratory, after the selection of the most representative wood species and combustion equipment in Portugal, a sampling program to determine gaseous and particulate matter emission rates was set up, including organic and inorganic aerosol composition. In the field, the smoke plumes from agriculture/garden waste and experimental wildland fires were sampled. The results of this study show that the combustion equipment and biofuel type used have an important role in the emission levels and composition. Significant differences between the use of traditional combustion equipment versus modern equipments were also observed. These differences are due to higher combustion efficiency of modern equipment, reflecting the smallest amount of particulate matter, organic carbon and carbon monoxide released. With regard to experimental wildland fires in shrub dominated areas, it was observed that the largest organic fraction in the samples studied was mainly composed by vegetation pyrolysis products. The major organic components in the smoke samples were pyrolysates of vegetation cuticles, mainly comprising steradienes and sterol derivatives, carbohydrates from the breakdown of cellulose, aliphatic lipids from vegetation waxes and methoxyphenols from the lignin thermal degradation. Despite being a banned practice in our country, agriculture/garden waste burning is actually quite common. To assess the particulate matter composition, the smoke from three different agriculture/garden residues have been sampled into 3 different size fractions (PM2.5, PM2.5-10 and PM>10). Despite distribution patterns of organic compounds in particulate matter varied among residues, the amounts of phenolics (polyphenol and guaiacyl derivatives) and organic acids were always predominant over other organic compounds in the organosoluble fraction of smoke. Among biomarkers, levoglucosan, β-sitosterol and phytol were detected in appreciable amounts in the smoke of all agriculture/garden residues. In addition, inositol may be considered as an eventual tracer for the smoke from potato haulm burning. It was shown that the prevailing ambient conditions (such as high humidity in the atmosphere) likely contributed to atmospheric processes (e.g. coagulation and hygroscopic growth), which influenced the particle size characteristics of the smoke tracers, shifting their distribution to larger diameters. An assessment of household biomass consumption was also made through a national scale survey. The information obtained with the survey combined with the databases on emission factors from the laboratory and field tests allowed us to estimate the pollutant amounts emitted in each Portuguese district. In addition to a likely contribution to the improvement of emission inventories, emission factors obtained for tracer compounds in this study can be applied in receptor models to assess the contribution of biomass burning to the levels of atmospheric aerosols and their constituents obtained in monitoring campaigns in Mediterranean Europe.
Resumo:
Tem havido uma preocupação crescente com a qualidade do ar interior (QAI) nas escolas em muitos países. Muitos estudos epidemiológicos têm encontrado diferenças regionais entre ambientes interiores. Apesar da elevada incidência de asma e rinite na população infantil, praticamente nada se sabia sobre a QAI em escolas portuguesas. A percepção dos problemas de QAI é crucial para avaliar os riscos para a saúde e rendimento dos estudantes, e para sugerir meios de reduzir a exposição a poluentes indesejáveis. Neste estudo procurou-se obter as concentrações de poluentes de interesse em estabelecimentos de ensino do 1º ciclo de Lisboa e Aveiro, estimar o estado atual de casos de asma e rinite em escolas primárias da capital, avaliar a influência de diferentes materiais das salas de aula/construção e hábitos escolares na QAI, identificar potenciais fontes de poluentes nos interiores e exteriores das salas de aula e propor medidas mitigadoras. Catorze escolas de Lisboa foram visitadas para obter a caracterização física das construções em termos de estrutura, ventilação, materiais de acabamento, produtos de limpeza, densidade de ocupação e potenciais fontes interiores de poluição. Os estudantes foram questionados sobre os seus hábitos e sintomas respiratórios através de inquéritos do modelo ISAAC (International Study of Asthma and Allergies in Childhood). Durante a primavera, outono e inverno (2008-2010), nas salas de aula e pátios, foram monitorizados, por amostragem passiva, compostos orgânicos voláteis (COVs), carbonilos e dióxido de azoto (NO2). Foram também medidos parâmetros de conforto e níveis de microrganismos. Duas escolas localizadas, uma no centro da cidade e outra na região suburbana, em Aveiro foram estudadas em 2010. Parâmetros de conforto, microrganismos, COVs, NO2, material particulado (PM10) foram medidos no interior e no exterior de ambas escolas. Os iões solúveis, carbono orgânico e elementar (OC e EC), e compostos orgânicos presentes no material particulado foram subsequentemente analisados em laboratório. Uma medida mitigadora - fitoremediação - foi avaliada na escola do centro da cidade de Aveiro em 2011. Os resultados do estudo mostraram que a QAI é pior do que a do ar exterior. Em geral, os níveis de CO2 e dos bioaerosóis excederam os níveis máximos aceitáveis para o conforto dos ocupantes estipulado pelas regulamentações portuguesas. Quase todos os COVs e carbonilos identificados mostraram razões interior/exterior (I/E) maiores que uma unidade, o que demonstra a importante contribuição de fontes interiores em todas as escolas. As razões I/E das concentrações de NO2 nunca excederam a unidade. Os níveis interiores diários de PM10 foram sempre maiores que os exteriores, exceto nos fins de semana. Após a colocação de plantas numa das salas de aula, observou-se uma redução estatisticamente significativa nos níveis de CO2, COVs, carbonilos, PM10, OC, e dos iões nitrato, sulfato, amónia, cálcio e carbonato. A possível redução dos níveis de poluentes no interior após a colocação de plantas pode representar uma solução de baixo custo para reduzir a exposição a muitos compostos, melhorar o rendimento e aumentar o bem estar dos alunos e professores em sala de aula.
Resumo:
Um dos principais fatores que afetam negativamente a qualidade do ambiente em muitas cidades em todo o mundo é o material particulado (PM). A sua presença na atmosfera pode ter impactos negativos na saúde humana, clima, património edificado e ecossistemas. Muitos dos estudos realizados em áreas urbanas focam apenas as frações respiráveis (PM10 e PM2,5). No entanto, os processos de formação, a identificação das fontes emissoras e os efeitos dependem muito da distribuição granulométrica das partículas. A atenção tem recaído na análise de hidrocarbonetos poliaromáticos (PAHs), devida à sua carcinogenicidade e a informação disponível sobre outros compostos é escassa. O presente estudo consistiu na obtenção do PM distribuído por diferentes frações de tamanho e na análise detalhada da sua composição química, em dois locais urbanos da Península Ibérica (Madrid e Lisboa). Dado que os veículos representam uma das principais fontes emissoras em ambientes urbanos, efetuou-se uma caracterização mais detalhada deste tipo de emissões, conduzindo uma campanha de amostragem num túnel rodoviário (Marquês de Pombal, Lisboa). As amostragens, em ambas as cidades, decorreram durante um mês, quer no verão quer no inverno, em dois locais urbanos distintos, um junto a uma via com influência de tráfego e outro numa área urbana de fundo. No túnel a amostragem foi realizada apenas durante uma semana. Em Madrid e no túnel, o PM foi recolhido utilizando um amostrador de elevado volume com impactor em cascata com quatro tamanhos: 10-2,5, 2,5-0,95, 0,95-0,49 e < 0,49 μm. Em Lisboa, foi utilizado um impactor em cascata com apenas dois tamanhos, 10- 2,5 e < 2,5 μm. As amostras foram quimicamente analisadas e determinadas as concentrações de compostos carbonados (OC, EC e carbonatos), iões inorgânicos solúveis em água (Cl−, NO3−, SO42−, Na+, NH4+, K+, Mg2+, Ca2+),metais e compostos orgânicos. Em Madrid, as concentrações médias de PM10 foram 44 e 48% maiores nas amostras recolhidas junto à estrada do que as de fundo urbano no verão e inverno, respetivamente. A fração grosseira e o PM0,5 apresentaram concentrações mais elevadas no verão do que no inverno devido às condições climatéricas pouco usuais. No verão, as amostragens decorreram num mês em que as temperaturas foram muito elevadas e em que ocorreram vários episódios de intrusão de poeira africana. Durante o período de amostragem de inverno, as temperaturas foram muito baixas e registaram-se vários dias de precipitação quer sob a forma de chuva, quer sob a forma de neve. As situações meteorológicas sinóticas mais comuns, incluindo aquelas que causam o transporte de massas de ar com poeiras Africanas, foram identificadas em ambas as estações do ano. As concentrações mássicas de PM10, EC e OC foram encontrados predominantemente na fração de tamanho ultrafino em ambos os locais de amostragem e estações do ano. Nas restantes frações não se observou nenhuma tendência sazonal. O carbono orgânico secundário (SOC) mostrou um claro padrão sazonal, com concentrações muito mais elevadas no verão do que no inverno, em ambos os lugares. A partir do balanço mássico de iões, observou-se que, no verão, a formação de compostos inorgânicos secundários (SIC) conduziu a um enriquecimento pouco comum de Ca2+ na fração submicrométrica, quer nas amostras de tráfego, quer em fundo urbano. Os alcanos, PAHs, os álcoois e os ácidos foram as classes de compostos orgânicos identificados e quantificados no material particulado. Globalmente, representaram 0,26 e 0,11 μg m−3 no verão e inverno, respetivamente, no local de tráfego e 0,28 e 0,035 μg m−3 na área urbana de fundo. Os diferentes compostos orgânicos também apresentaram padrões sazonais, sugerindo fontes de emissão (e.g. escapes dos veículos e fontes biogénicas) ou processos de formação com contribuições variáveis ao longo do ano. As concentrações de benzoapireno equivalente foram menores que 1 ng m-3 e o risco carcinogénico estimado é baixo. No verão, os maiores enriquecimentos de metais ocorreram na fração submicrométrica, e no inverno na fração grosseira. No verão, os enriquecimentos foram ≥ 80% para o Mn, Ni, Cu, Zn, Cd, Sb e Co, no inverno, estes traçadores de emissões do tráfego foram menores, exceto para o Zn. Em Lisboa, a concentração média de PM10 foi de 48 μg m-3 no verão e de 44 μg m-3 no inverno, junto à estrada. Na área de fundo urbano, registaram-se níveis comparáveis nas duas estações (27 μg m-3 e 26 μg m-3). A média do rácio PM2,5/PM10 foi de 65% no verão e 44% no inverno na área de tráfego e 62% e 59% na área urbana de fundo. Estes resultados significam que o PM2,5 é um dos principais contaminantes que afetam a qualidade do ar no centro da cidade de Lisboa. A relação OC/EC, que reflete a composição das emissões de combustão dos veículos, variou entre 0,3 e 0,4 no interior do túnel. Os rácios de OC/EC mínimos obtidos junto às vias de tráfego em Madrid e em Lisboa encontram-se entre os do túnel e os registados em atmosferas urbanas de fundo, sugerindo que os valores mínimos habitualmente obtidos para este parâmetro em ambientes urbanos abertos sobrestimam as emissões diretas de OC pelo transporte rodoviário. Espera-se que os resultados deste trabalho contribuam para suprir, pelo menos em parte, as lacunas de informação quer sobre a composição de várias granulometrias de PM, quer sobre fontes e processos de formação em atmosferas urbanas. Como a exposição a poluentes do ar ultrapassa o controle dos indivíduos e exige ação das autoridades públicas a nível nacional, regional e até mesmo internacional, é importante propor medidas mitigadoras focadas nas principais fontes de emissão identificadas.
Resumo:
Allergies to grass pollen are the number one cause of outdoor hay fever. The human immune system reacts with symptoms to allergens from pollen. Objective: We investigated the natural variability in release of the major group 5 allergen from grass pollen across Europe. Methods: Airborne pollen and allergens were simultaneously collected daily with a volumetric spore trap and a high-volume cascade impactor at 10 sites across Europe for 3 consecutive years. Group 5 allergen was determined with a Phl p 5 specific ELISA in two fractions of ambient air: Particulate Matter (PM) >10μm and 10μm>PM>2.5μm. Mediator release by ambient air was determined in FcεR1-humanized basophils. Origin of pollen was modeled and condensed to pollen potency maps. Results: On average grass pollen released 2.3 pg Phl p 5/pollen. Allergen release per pollen (potency) varied substantially, ranging from 0 to 9 pg Phl p 5/pollen (5 to 95% percentile). The main variation was locally day-to-day. Average potency maps across Europe varied between years. Mediator release from basophilic granulocytes correlated better with allergen/m3 (r2=0.80, p<0.001) than with pollen/m3 (r2=0.61, p<0.001). In addition, pollen released different amounts of allergen in the nonpollen bearing fraction of ambient air depending on humidity. Conclusion: Across Europe, the same amount of pollen released substantially different amounts of group 5 grass pollen allergen. This variation in allergen release is on top of variations in pollen counts. Molecular aerobiology, i.e. determining allergen in ambient air, may be a valuable addition to pollen counting.
Resumo:
Thesis (Ph.D.)--University of Washington, 2013
Resumo:
Future changes in population exposures to ambient air pollution are inherently linked with long-term trends in outdoor air quality, but also with changes in the building stock. Moreover, the burden of disease is further driven by the ageing of the European populations. This study aims to assess the impact of changes in climate, emissions, building stocks and population on air pollution related human health impacts across Europe in the future. Therefore an integrated assessment model combining atmospheric models and health impacts has been setup for projections of the future developments in air pollution related premature mortality. The focus is here on the regional scale impacts of exposure to surface ozone (O3), Secondary Inorganic Aerosols (SIA) and primary particulate matter (PPM).
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.