936 resultados para Effluent irrigation
Resumo:
A case of peritonitis due to Scedosporium apiospermum in a boy undergoing continuous ambulatory peritoneal dialysis is reported. The finding of suggestive tissual form of the fungus in the effluent hastened the diagnosis of the infection.
Resumo:
Dissertation presented to obtain the Ph.D degree in Biochemistry, Plant Physiology
Resumo:
The aim of this study was to compare the fecundity and fertility of B. glabrata and B. straminea by cross- and self-fertilization. To attain this objective, laboratory-raised strains of B. glabrata and B. straminea were used. The former originated from natural breeding grounds in the municipality Paulista, state of Pernambuco, Brazil. The latter originated from irrigation ditches in the municipality of Petrolândia, in the same state. Snail populations of B. glabrata and B. straminea were maintained for 240 days in laboratory. Their fecundity was evaluated by noting the number of egg-masses, eggs and eggs per mass. Their fertility was evaluated by the number of viable eggs and the hatching rate. B. straminea was markedly more fecund than B. glabrata through cross- and self-fertilization, namely: greater egg-mass; higher egg production and more eggs per mass. Regarding fertility, there seemed to be no preferential period for occlusion to occur or a trend in the rhythm of producing viable eggs.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.
Resumo:
Um dos objetivos desta dissertação de mestrado foi avaliar o impacto ambiental do processo de tingimento usado na indústria de curtumes, em termos de volume de efluente produzido e sua carga poluente. Pretendeu-se também encontrar alternativas ao nível do processo de tingimento que levem a uma melhoria na qualidade do efluente produzido. Outro objetivo deste trabalho foi avaliar o funcionamento da ETAR existente na empresa JR Fontes, no que diz respeito aos parâmetros em estudo (carência química de oxigénio - CQO, pH, crómio e teor de sólidos suspensos totais - SST), propondo alterações que permitam respeitar os valores de emissão exigidos na licença de descarga da empresa. Verificou-se que o processo de tingimento aplicado pela empresa JR Fontes é muito poluente, em termos de carga orgânica e matéria em suspensão. Este facto é comprovado pelos resultados obtidos para os três processos estudados: Montana, Galáctico e Navak. Todos os processos apresentam um efluente com pH ácido (aproximado a 3) e valores de CQO superiores a 3550 mg O2/L, sendo o processo Navak aquele que apresenta o valor mais alto para o banho composto, 8362 mg O2/L. Relativamente ao teor de crómio, o banho de recurtume com concentração mais elevada de crómio total é o banho 1 do processo Navak, com 2297 mg/L, sendo que a concentração destes banhos é sempre elevada, igual ou superior a 746 mg/L. No que diz respeito à matéria em suspensão, o processo Navak é novamente o mais poluente, com um valor de 3842 mg SST/L, não sendo obtidos nos outros processos, valores inferiores a 1205 mg SST/L. Na realização de um processo alternativo de tingimento verificou-se que é possível diminuir a carga orgânica do efluente originado. A aplicação de recurtumes sintéticos deu origem a efluentes menos poluentes. O melhor valor obtido para a CQO foi de 1113 mg O2/L, sendo obtidos valores não superiores a 7185 mg O2/L para processos de características semelhantes aos aplicados nesta indústria. Relativamente à ETAR, apesar das restrições ao funcionamento que esta apresenta, no geral pode ser considerada eficiente, embora não consiga atingir o objetivo pretendido de remoção para a CQO, ou seja o valor de 1100 mg O2/L. Nos restantes parâmetros é cumprido o limite de emissão (350 mg SST/L, pH entre 6 e 9 e 2 mg Cr/L para o crómio total): os SST apresentam o valor de 98 mg SST/L, o crómio total de 1,2 mg Cr/L e o pH encontra-se entre 8 e 9. São aqui feitas duas abordagens para solucionar os problemas existentes na ETAR. A primeira considera um ajuste no tratamento e equipamentos existentes, através da reconstrução do tanque de equalização, da substituição do coagulante por sulfato ferroso e da reconstrução do sedimentador, assim como a substituição das tubagens por umas de maior diâmetro, solucionando assim problemas de manutenção de toda a instalação e do incumprimento da legislação. A outra abordagem implica a substituição do sistema de afinação existente, os filtros de areia e carvão ativados, por um sistema de membranas de ultrafiltração ou por dois filtros de carvão ativado. Para tratar um efluente com um valor de CQO de 3000 mg O2/L com o carvão estudado, seriam necessários 132 kg de carvão por coluna, aproveitando-se os equipamentos existentes. No caso das membranas filtrantes, estas são eficazes, reduzindo a CQO em cerca de 70%. Ao contrário do carvão, a aplicação deste sistema implicaria a aquisição de novos equipamentos. Futuramente propõe-se a avaliação dos vários tipos de reagentes usados no tingimento de couro de forma a aplicar no tratamento aqueles que produzam as características desejadas no produto final e a que apresentem um menor resultado de CQO. Propõe-se também o estudo de viabilidade da remoção de crómio dos banhos de recurtume e consequente avaliação da aplicabilidade de um tratamento biológico em substituição ou como complemento do tratamento existente.
Resumo:
Abstract: Preferential flow and transport through macropores affect plant water use efficiency and enhance leaching of agrochemicals and the transport of colloids, thereby increasing the risk for contamination of groundwater resources. The effects of soil compaction, expressed in terms of bulk density (BD), and organic carbon (OC) content on preferential flow and transport were investigated using 150 undisturbed soil cores sampled from 15 × 15–m grids on two field sites. Both fields had loamy textures, but one site had significantly higher OC content. Leaching experiments were conducted in each core by applying a constant irrigation rate of 10 mm h−1 with a pulse application of tritium tracer. Five percent tritium mass arrival times and apparent dispersivities were derived from each of the tracer breakthrough curves and correlated with texture, OC content, and BD to assess the spatial distribution of preferential flow and transport across the investigated fields. Soils from both fields showed strong positive correlations between BD and preferential flow. Interestingly, the relationships between BD and tracer transport characteristics were markedly different for the two fields, although the relationship between BD and macroporosity was nearly identical. The difference was likely caused by the higher contents of fines and OC at one of the fields leading to stronger aggregation, smaller matrix permeability, and a more pronounced pipe-like pore system with well-aligned macropores.
Resumo:
In this work, kriging with covariates is used to model and map the spatial distribution of salinity measurements gathered by an autonomous underwater vehicle in a sea outfall monitoring campaign aiming to distinguish the effluent plume from the receiving waters and characterize its spatial variability in the vicinity of the discharge. Four different geostatistical linear models for salinity were assumed, where the distance to diffuser, the west-east positioning, and the south-north positioning were used as covariates. Sample variograms were fitted by the Mat`ern models using weighted least squares and maximum likelihood estimation methods as a way to detect eventual discrepancies. Typically, the maximum likelihood method estimated very low ranges which have limited the kriging process. So, at least for these data sets, weighted least squares showed to be the most appropriate estimation method for variogram fitting. The kriged maps show clearly the spatial variation of salinity, and it is possible to identify the effluent plume in the area studied. The results obtained show some guidelines for sewage monitoring if a geostatistical analysis of the data is in mind. It is important to treat properly the existence of anomalous values and to adopt a sampling strategy that includes transects parallel and perpendicular to the effluent dispersion.
Resumo:
O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.
Resumo:
A atividade humana e industrial usa a água para as suas atividades do quotidiano. A água é um recurso natural escasso cuja qualidade deve ser protegida, defendida, gerida e tratada em conformidade com o seu uso. Nesse âmbito, a gestão das águas prossegue objetivos de proteção da saúde humana e de preservação, proteção e melhoria da qualidade do ambiente[1]. Desde o final do seculo XIX até aos dias de hoje, verificou-se uma forte evolução nos sistemas de tratamento de águas residuais. Esta evolução foi fundamental para dar resposta às maiores exigências de qualidade do efluente tratado. O sistema de lamas ativadas é um dos processos de tratamento biológico das águas residuais mais usados em todo o mundo. Este trabalho consiste no desenvolvimento do projeto de conceção e dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) para servir um pequeno aglomerado de cerca de 3200 habitantes equivalentes (hab.eq.), tendo como objetivo o dimensionamento de todas as etapas de tratamento necessárias ao cumprimento da legislação em vigor para a descarga das águas residuais urbanas no meio recetor. O Decreto-lei nº 152/97[2], relativo ao tratamento de águas residuais urbanas, juntamente com o Decreto-lei nº 149/2004[3] que identifica as zonas sensíveis e de zonas menos sensíveis, permitem que as entidades licenciadoras definam o grau de tratamento que a instalação deve possuir tendo em consideração a classificação do meio onde o efluente tratado é descarregado. O Decreto-Lei n.º 135/2009[1] estabelece o regime de identificação, gestão, monitorização e classificação da qualidade das águas balneares, impondo a qualidade microbiológica da água residual tratada mediante o meio recetor, e portanto conseguindo-se assim definir o tratamento de desinfeção a adotar. Resumidamente, a conceção do tratamento focou as seguintes etapas: tratamento preliminar formado por uma unidade compacta de tamisação, desarenador e desengordurador, tratamento secundário por lamas ativadas em regime de arejamento prolongado constituído por dois reatores com cerca de 400 m3 de volume seguido de um decantador com um diâmetro de 9.5 m, tratamento terciário de desinfeção composto por uma microtamisação seguido de desinfeção UV, e a utilização das operações comuns de espessamento e desidratação das lamas produzidas em excesso pelo tratamento, constituída por com um espessador gravítico com 4.6 m de diâmetro, e um filtro banda para a desidratação.
Resumo:
O presente trabalho teve como objectivo a minimização do impacto ambiental do processo de curtume da pele de bovino. A indústria de curtumes transforma a pele, material putrescível, em couro, material nobre, termicamente estável e imputrescível. A transformação da pele em couro origina uma carga poluente apreciável quer quanto a efluentes líquidos quer quanto a resíduos sólidos. O fluxo produtivo da indústria de curtumes pode dividir-se em quatro sectores: ribeira, curtume, tinturaria e acabamento, sendo que os três primeiros geram efluentes líquidos com elevada carga poluente. Neste trabalho, foram avaliadas as fases do processo que geram efluentes líquidos: molho, caleiro, curtume e tinturaria. Na avaliação do processo do molho testou-se uma protease e uma lipase contra um molhante e um desengordurante tradicional, agentes químicos normalmente utilizados no molho mas menos biodegradáveis que as enzimas testadas. Salienta-se o bom resultado obtido quanto à eficiência do molho Na avaliação do processo de caleiro testaram-se várias alternativas no sentido da redução da quantidade de sulfureto de sódio utilizada e da minimização da carga poluente. Entre as alternativas, depilação por oxidação, depilação enzimática com e sem destruição do pêlo, elegeu-se a depilação enzimática sem destruição do pêlo que conduziu a resultados com menor impacto ambiental, nomeadamente a redução da % da quantidade de sulfureto de sódio, sendo a redução da carga poluente de 4,19 % de sulfureto, 32.80% de sólidos suspensos totais (SST),27.09% de sólidos totais (ST) e de 76.90% da carência química de oxigénio (CQO) no efluente de caleiro. No processo do curtume da pele é utilizado crómio como agente de curtume em cerca de 80% das peles tratadas, sendo este metal problemático em termos ambientais. No sentido de reduzir a quantidade de crómio utilizada no processo foi realizado um planeamento factorial onde as variáveis a estudar foram a concentração de crómio e a temperatura, tendo este como objectivo observar qual a quantidade mínima de crómio necessária para termos um produto final nas condições desejadas e gerando um menor impacto ambiental. Concluiu-se desenvolvendo um processo que mostra ser possível reduzir a quantidade de sal de crómio de 7% para 5%, além de ter um impacto ambiental claramente menos agressivo nos efluentes de curtume gerado. Este processo quando comparado com o processo tradicional permite a redução de 27% na CQO, 79% nos SST, 11% nos ST e 38% no teor de crómio Na avaliação do processo de tinturaria foi estudado um processo compacto contra o processo tradicional, tendo-se concluído pelo menor impacto ambiental do processo estudado, nomeadamente ao nível da redução do consumo de água e da carga poluente gerada. A comparação dos dois processos, no que respeita à carga poluente gerada, permitiu concluir por uma redução de 39% da CQO, 50% dos SST, e 12% dos ST quando aplicado o processo compacto Por fim foi feita uma avaliação do impacto ambiental do efluente global gerado pelos processos considerados com menor impacto ambiental contra o processo tradicional, normalmente aplicado na indústria. A aplicação do conjunto dos processos desenvolvidos, quando comparada com a aplicação do conjunto dos processos tradicionais, mostra uma redução de 1% no sulfureto, 40% na CQO, 60 % nos SST, 42 % no crómio e 11% nos ST, mostrando claramente que é possível reduzir a carga poluente da indústria de curtumes atuando no processo. Este trabalho mostrou a importância de atuar no processo para minimizar os custos de tratamento e mesmo de investimento dos efluentes da indústria de curtumes. Importa salientar que os processos desenvolvidos necessitam de validação a uma escala semi-industrial.
Resumo:
This paper reports on the findings of a survey on OCI storage in people in Bahia, Brasil. In this survey 11 samples of adipose tissue were taken from people who underwent splenectomy for hepato splenic schistosomiasis. In these patients, total DDT averaged 10.66 ppm as compared to 4,83 ppm of total DDT found in presumably healthy people. The difference was statistically significant. It is considered that the increased DDT storage in patients with hepatosplenic schistosomiass may be the result of a reduced metabolzation of p,p'-DDT and reduced excretion of its metabolites. Another possíbility is the increased exposure to organochlorine nsectedes by hepatosplenc patients who frequently come from irrigation zones, where these compounds are more used in intensive cultivatíon.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
Dissertação para a obtenção do Grau de Mestre em Engenharia e Gestão da Água