995 resultados para Base-flow
Resumo:
Dissertação de mestrado em Ecologia
Resumo:
Dissertação de mestrado em Bioquímica Aplicada (área de especialização em Biotecnologia)
Resumo:
Dissertação de mestrado em Educação Especial (área de especialização em Dificuldades de Aprendizagem Específicas)
Resumo:
Dissertação de mestrado em Educação Especial (área de especialização em Dificuldades de Aprendizagem Específicas)
Resumo:
OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75%) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99%) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97%) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.
Resumo:
OBJECTIVE: To identify the left inferior pulmonary vein as an indirect marker of increased pulmonary flow in congenital heart diseases.METHODS: We carried out a prospective consecutive study on 40 patients divided into 2 groups as follows: G1 - 20 patients diagnosed with congenital heart disease and increased pulmonary flow; G2 (control group) - 20 patients who were either healthy or had congenital heart disease with decreased or normal pulmonary flow. We obtained the velocity-time integral of the left inferior pulmonary vein flow, excluding the "reverse A" wave, with pulsed Doppler echocardiography.RESULTS: In G1, 19 out of the 20 patients had well-identified dilation of the left inferior pulmonary vein. No G2 patient had dilation of the left inferior pulmonary vein. Dilation of the left inferior pulmonary vein in conditions of increased pulmonary flow had sensitivity of 95%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 95% (1 false-negative case). The integral of time and velocity of the pulmonary venous flow obtained with pulsed Doppler echocardiography was greater in the G1 patients (G1=25.0±4.6 cm versus G2=14.8±2.1 cm, p=0.0001).CONCLUSION: The identification of dilation of the left inferior pulmonary vein suggests the presence of congenital heart disease with increased pulmonary flow. This may be used as an indirect sign of increased flow, mainly in malformations of difficult diagnosis, such as atrial septal defects of the venous sinus or coronary sinus type.
Resumo:
OBJECTIVE - To evaluate the Coronary Flow Reserve in the Coronary Sinus through transesophageal Doppler echocardiography in normal subjects. METHODS - We obtained technically adequate flow samples for analysis in 10 healthy volunteers (37±8 years, 5 men) with no history of heart or systemic disease and with mean left ventricular mass index by transthoracic echocardiography of 87±18 g/m². Coronary sinus flow velocity was recorded within the coronary sinus with the patient in a resting condition and during intravenous adenosine infusion at a dose of 140 µg/kg/min for 4 minutes. Recording of coronary sinus blood flow was possible in all cases with measurement of peak systolic, diastolic, and retrograde velocities (PSV, PDV, and PRV, cm/sec), mean systolic and diastolic velocities (MSV and MDV, cm/sec), and systolic and diastolic velocity time integral (VTI S and VTI D, cm/sec). RESULTS - The coronary flow reserve was calculated as the ratio between the blood flow in the basal state and the maximum measured hyperemic blood flow with adenosine infusion. Results are shown as mean and standard deviations. (CFR = PSV + PDV -- PRV/basal PSV): 1st min = 2.2±0.21; 2nd min = 3±0.3; 3rd min = 3.4±0.37; 4th min = 3.6 ± 0.33. CONCLUSION - Although coronary sinus flow had significantly increased in the first minute, higher velocities were seen at third and fourth minutes, indicating that these should be the best times to study coronary sinus flow with intravenous adenosine in continuous infusion.
Resumo:
Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.
Resumo:
Relatamos o caso de duas pacientes portadoras de arterite de Takayasu, encaminhadas ao nosso serviço onde as lesões acometiam a aorta torácica descendente e os vasos da base e, em uma delas, lesão obstrutiva crítica do óstio da coronária esquerda. Ambas as pacientes foram operadas sem circulação extracorpórea, com heparinização plena e auxílio de autotransfusão.
Resumo:
El objetivo del presente proyecto es evaluar las distintas causales de estrés en el bovino de abasto y, por ende, desarrollar un Manual ilustrado de Buenas Prácticas Pecuarias (BPP), referente al bienestar animal, para los establecimientos de producción bovina de carne de base pastoril que resulte de fácil transferencia y aplicación en nuestro sector productivo ganadero con la finalidad de minimizar, a través de la implementación del mismo, el impacto negativo que el inadecuado manejo de los animales en el campo, durante el transporte y en los corrales del frigorífico, tiene sobre los parámetros productivos y la calidad de la res y de la carne. Para ello se proponen realizar las siguientes actividades: 1. Determinar las principales causas de estrés en bovinos para faena que causan pérdidas cuantitativas y cualitativas en la res y la carne (carnes de corte oscuro o DFD, golpes o manchas verdes). 2. Visitar establecimientos productores de carne vacuna para la recopilación de información y de fotografías necesarias para la confección del Manual ilustrado de Buenas Prácticas Pecuarias (BPP) referido al bienestar del animal. 3. Diagramación y edición del Manual.
Resumo:
OBJETIVO: Determinar a prevalência de hipertensão arterial sistêmica e os fatores associados a sua ocorrência. MÉTODOS: Realizou-se um estudo transversal, de base populacional, na população de 20 a 69 anos residente na zona urbana de Pelotas-RS. A variável dependente hipertensão arterial sistêmica foi definida como pressão arterial >160 x 95 mmHg (média de duas medidas) ou o uso atual de medicação anti-hipertensiva. RESULTADOS: Entre as 1.968 pessoas incluídas no estudo, foi encontrada uma prevalência de 23,6% (IC95% 21,6 a 25,3) de hipertensão arterial. Os fatores de confusão foram controlados através da regressão de Poisson. Foram mantidas no modelo final com significância estatística as variáveis: renda familiar, idade, cor da pele, sexo, história familiar de hipertensão, consumo adicional de sal e índice de massa corporal. CONCLUSÃO: Observou-se um aumento da prevalência de hipertensão em comparação com estudo semelhante realizado em 1992. O maior aumento percentual de prevalência ocorreu nos grupos mais jovens.