826 resultados para Articuladores dentários
Resumo:
Cephalometric analysis is the mensuration of linear and angular measures through demarcation points as distances and lines on teleradiography, and is considered of fundamental importance for diagnosis and orthodontic planning. In this manner, the objective of this research was to compare cephalometric measurements obtained by dentists and radiologists from the analysis of the same radiograph, in a computerized cephalometric analysis program. All research participants marked 18 cephalometric points on a 14-inch notebook computer, as directed by the program itself (Radiocef 2®). From there, they generated 14 cephalometric parameters including skeletal, dental-skeletal, dental and soft tissue. In order to verify the intra-examiner agreement, 10 professionals from each group repeated the marking of the points with a minimum interval of eight days between the two markings. The intra-group variability was calculated based on the coefficients of variation (CV). The comparison between groups was performed using the Student t-test for normally distributed variables, and using the Mann-Whitney test for those with non-normal distribution. In the group of orthodontists, the measurements of Pog and 1-NB, SL, S-Ls Line, S-Li Line and 1.NB showed high internal variability. In the group of radiologists, the same occurred with the values of Pog and 1-NB, S-Ls Line, S-Li Line and 1.NA. In the comparison between groups, all the analyzed linear values and two angular values showed statistically significant differences between radiologists and dentists (p <0.05). According to the results, the interexaminer error in cephalometric analysis requires more attention, but does not come from a specific class of specialists, being either dentists or radiologists.
Resumo:
A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.
Resumo:
A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.
Resumo:
Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.
Resumo:
Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.
Resumo:
In the case of Brazilian Psychiatric Reformation, mental health juvenile reveals itself as a great challenge, with major gaps in terms of needs, services and actions on mental illness in children and adolescents. This research is a qualitative study of descriptive and exploratory, having to analyze the actions and practices of mental health juvenile articulated between the Psychosocial Care Center juvenile (Caps i) and the basic care in Natal-RN, and specific, identify the limits and possibilities for an important precedent of the care network. After submission to the Research Ethics Committee (CEP) of the University Hospital Onofre Lopes (HUOL) of the Federal University of Rio Grande do Norte (UFRN) obtained approval contained in opinion number 777.067 / 2014. For the data collection, it was initially carried out a documentary research in the Municipal Health Department of Christmas about the phenomenon under study, and subsequently, applied semi-structured interviews with the subjects of the research, which were workers Caps i of Natal-RN. The analysis was woven as the thematic analysis technique, understood within the method of content analysis. The results and discussions were organized by categories and subcategories, namely: CATEGORY 1: Limits and weaknesses in the linkage between the Caps i and basic care, with the subcategories: 1.1 Lack of specialized services and devices articulators in network, 1.2 The diversity of situations in the demand juvenile assisted; CATEGORY 2: possibilities for an effective network, with the subcategory: 2.1 Intersectoral collaboration as a strategy for solving attention. The analysis revealed that the integration and coordination of mental health services juvenile and primary care in the city of Natal-RN, has incipient initiatives and/or inadequate for the resolvability intersectoral, where the devices of attention to health involved cannot establish bonds effective and long-lasting in the perspective of co-responsibility and sharing of care. On the other hand, it appears that the existing shares and practiced, configure an exercise in approximation to the dialog between mental health juvenile and basic care. It is highlighted that the shared care and the establishment of intersectoral collaboration within and outside of the health sector is possibility of facilitating the necessary dialog between the services and professionals involved, thus, enabling a better prospect of resolvability of the Network of Psychosocial Care for the youth in reality being investigated.
Resumo:
CHAPTER 1 - This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrillinggroup) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. CHAPTER 2 - The objective of this preliminary histologic study was to determine whether the alteration of drilling protocols (oversized, intermediate, undersized drilling) present different biologic responses at early healing periods of 2 weeks in vivo in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.5 mm, 3.75 mm, and 4.0 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical significance was set to 95% level of confidence and the number of dogs was considered as the statistical unit for all comparisons. For the torque and BIC and BAFO, a general linear model was employed including instrumentation technique and time in vivo as independent. Overall, the insertion torque increased as a function of drilling diameter from 4.0 mm, to 3.75 mm, to 3.5 mm, with a significant difference in torque levels between all groups (p<0.001). Statistical assessment of BIC and BAFO showed significantly higher values for the 3.75 mm (recommended) drilling group was observed relative to the other two groups (p<0.001). Different drilling dimensions resulted in variations in insertion torque values (primary stability) and different pattern of healing and interfacial remodeling was observed for the different groups. CHAPTER 3 - The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance). Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque–removal torque paired observations was statis- tically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups. Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.
Resumo:
The coexistence of gingival recession (GR) with root coverage indication and non-carious cervical lesions (LCNC) generates the need for a protocol that respects and promotes health of dental and periodontal tissues and allows treatment predictability. The main objectives of this theses were: (1) verify, through clinical evaluations, the connective tissue graft for root coverage on direct and indirect restorations made of ceramic resin; (2) analyze the influence of the battery level of the LED curing unit in the composite resin characteristics; (3) assess the influence of restorative materials, composite resin and ceramics, on the viability of gingival fibroblasts from primary culture. Nine patients with good oral hygiene and occlusal stability diagnosed with LCNCs the anterior teeth including premolars associated with gingival recession (class I and II of Miller) and only gingival recession were selected. After initial clinical examination, occlusal adjustment was performed and the patients had their teeth randomized allocated on direct composite resin restoration of LCNC, polishing and GR treatment with connective tissue graft and advanced coronally flap CR group (n = 15); and indirect ceramic restoration of the LCNC's and GR treatment (CTG+CAF) Group C (n = 15). The GR presented teeth with no clinically formed LCNCs cavity were treated using (CTG+CAF) being the control group (n = 15). Sorption and solubility tests, analysis of the degree of conversion and diametral tensile strength were performed in composite resin samples (n = 10) photoactivated by 100, 50 and 10% battery charge LED unit. The viability of fibroblasts on composite resin, ceramics and dentin disks (n = 3) was examined. Clinical follow-up was performed for three months. The data obtained at different stages were tabulated and subjected to analysis for detection of normal distribution and homogeneity. The results showed that: the LED unit with 10% battery affects the characteristics of the composite resin; restorative materials present biocompatibility with gingival fibroblasts; and the association of surgical and restorative treatment of teeth affected by NCCL and GR presents successful results at 3-month follow-up.
Resumo:
The general aim of this study was to evaluate the conical interface of pilar/implant. The specific aims were to evaluate the influence of hexagonal internal index in the microleakage and mechanical strength of Morse taper implants; the effect of axial loading on the deformation in cervical region of Morse taper implants of different diameters through strain gauge; the effect of axial loading in cervical deformation and sliding of abutment into the implant by tridimensional measurements; the integrity of conical interface before and after dynamic loading by microscopy and microleakage; and the stress distribution in tridimensional finite element models of Morse taper implants assembled with 2 pieces abutment. According to the obtained results, could be concluded that the diameter had influence in the cervical deformation of Morse taper implants; the presence of internal hexagonal index in the end of internal cone of implant didn´t influenced the bacterial microleakage under static loading neither reduced the mechanical strength of implants; one million cycles of vertical and off-center load had no negative influence in Morse taper implant integrity.
Resumo:
Background: Several theories, such as the biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, and the periimplant stress/strain concentration causing bone microdamage accumulation, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim: to evaluate clinical, bacteriological, and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Materials and methods: Twelve patients with totally edentulous mandibles received four custom made Ø 3.8 x 13 mm implants in the interforaminal region of the mandible, with the same design, but different prosthetic connections (two of them EH or MT, randomly placed based on a split-mouth design), and a immediate implant- supported prosthesis. Clinical parameters (periimplant probing pocket depth, modified gingival index and mucosal thickness) were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6 and 12 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tanerella forsythia, Porphyromonas gingivalis, Aggragatibacter actinomycetemcomitans, Prevotella intermedia and Fusobacterium nucleatum. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t- test. Further, 36 computer-tomographic based finite element (FE) models were accomplished, simulating each patient in 3 loading conditions. The results for the peak EQV strain in periimplant bone were interpreted by means of a general linear model (ANOVA). Results: The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P<0.001). Mean IT-FBIC was 1.17±0.44 mm for EH, and 0.17±0.54 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P=0.005) was found for EH (mean 3438.65 µ∑) compared to MT (mean 840.98 µ∑) connection. Conclusions: Varying implant-abutment connection type will result in diverse periimplant bone remodeling, regardless of clinical and microbiological conditions. This fact is more likely attributed to the singular loading transmission through different implant-abutment connections to the periimplant bone. The present findings suggest that Morse-taper connection is more efficient to prevent periimplant bone loss, compared to an external hexagon connection.
Resumo:
This thesis, part of the research line "Work, Society and Education" analyzes, in a dialectical perspective, in the light of Tragtenberg´s studies, the conception of subject of schoolwork, considering the organization and the complexity of this context and inviting the investigative gaze. Our hypothesis is that the workers of education have, in the schoolwork, a fragile politicization field and overcoming the installed model, accepting themselves as executers with self-organizing difficulties, distanced from the effective participation, autonomy and self-management. We consider studies on the logic of the work, believing that the understanding of schoolwork is constitute into the current societal model, in whom its bureaucratic and hierarchical matrix, linked to articulated / articulators of the dominant socio-economic class interests. Scholars such as Braverman, Frigotto and Tragtenberg, among others, are important contributions to this reflection. We have analyzed the logic of the work also in dialogue with pedagogies differentiated, among them, the Libertarian defended by Tragtenberg, aiming to understand the conceptions and practices of the subjects involved. We accomplished a bibliographical critical analysis, in a dialectical character, focusing on the categories: work, schoolwork, control, autonomy and self-management, in order to understand the complexity of the praxis in study, dialoguing with the pillars categories historicity, contradiction and totality, which transversalize the developed analysis. The consideration of these concepts allows us to uncover the dominant bureaucratic structure and its possible overcoming fields. We believe contribute to problematizing and proposers studies, reflections and discussions, strengthening debates, deconstructing naturalizations and contributing to the political process of the subjects.
Resumo:
O presente estudo tece nexos entre sociedade de consumo, lazer e juventudes, cientes da complexidade dado o modo de vida estruturado pelo capital. Mais especificamente, trata do lazer vivenciado em danceterias da cidade de Santa Maria/RS, o qual se constituiem um dos principais espaços de lazer da juventude universitária. As danceterias vendem seus produtos com a promessa de liberdade e de plena fruiçao. Todavia elas nao podem ser entendidas somente pelo viés do negócio, mas articuladores do encontro e da fruiçao de sujeitos sociais. Destacamos a necessidade de políticas públicas de lazer articuladas com os ideais e desejos da juventude e como prática de liberdade
Resumo:
O presente estudo tece nexos entre sociedade de consumo, lazer e juventudes, cientes da complexidade dado o modo de vida estruturado pelo capital. Mais especificamente, trata do lazer vivenciado em danceterias da cidade de Santa Maria/RS, o qual se constituiem um dos principais espaços de lazer da juventude universitária. As danceterias vendem seus produtos com a promessa de liberdade e de plena fruiçao. Todavia elas nao podem ser entendidas somente pelo viés do negócio, mas articuladores do encontro e da fruiçao de sujeitos sociais. Destacamos a necessidade de políticas públicas de lazer articuladas com os ideais e desejos da juventude e como prática de liberdade
Resumo:
O presente estudo tece nexos entre sociedade de consumo, lazer e juventudes, cientes da complexidade dado o modo de vida estruturado pelo capital. Mais especificamente, trata do lazer vivenciado em danceterias da cidade de Santa Maria/RS, o qual se constituiem um dos principais espaços de lazer da juventude universitária. As danceterias vendem seus produtos com a promessa de liberdade e de plena fruiçao. Todavia elas nao podem ser entendidas somente pelo viés do negócio, mas articuladores do encontro e da fruiçao de sujeitos sociais. Destacamos a necessidade de políticas públicas de lazer articuladas com os ideais e desejos da juventude e como prática de liberdade
Resumo:
O sorriso não se baseia apenas em factores dentários relacionados com a cor, a forma ou o alinhamento dos dentes na arcada, mas implica também a presença de tecidos periodontais saudáveis e com um contorno gengival harmónico. Este trabalho tem como objectivo abordar as diversas técnicas de aumento de coroa clínica, enunciar as vantagens e indicações das mesmas, bem como comparar as técnicas cirúrgicas com as ortodônticas. Para tal foi realizada uma pesquisa bibliográfica recorrendo aos motores de busca da Pubmed e b-on, utilizando como palavras-chave: crown lengthening, biological width, crown lengthening AND surgery e crown lengthening AND orthodontic extrusion. Dos 539 artigos encontrados, foram seleccionados 28 que correspondiam aos critérios de inclusão por nós estabelecidos. Critérios de inclusão: meta-análises, ensaios clínicos randomizados e revisões sistemáticas publicadas em Português, Inglês e Espanhol nos últimos 12 anos. De acordo com a literatura, podemos verificar que o aumento de coroa clínica está indicado em várias situações clínicas tais como: cáries infra-gengivais, fracturas radiculares, resolução de alguns problemas estéticos, como o sorriso gengival, principalmente em casos de erupção passiva alterada e assimetrias das margens gengivais. Este aumento pode ser realizado por técnicas cirúrgicas (gengivectomia e retalho de reposicionamento apical), técnicas ortodônticas (extrusão ortodôntica com ou sem fibrotomia) ou através da combinação de ambas.