980 resultados para Altman, Ida
Resumo:
The actual study goal is to test the Ellestad and Weltman protocol concordance in the prediction of VO2max in Futsal athletes. There was no significant difference between the two protocols, there was significant correlation between methods, but the Bland & Altman plotting shown very high amplitude in the Confident Interval at 95%.
Resumo:
O futsal é uma modalidade intermitente cuja a participação do metabolismo aeróbio é importante na ressíntese de ATP e CP gastos anaerobiamente. A capacidade aeróbia máxima (VO2max) pode ser mensurada por testes de campo e testes laboratoriais. Dentre os vários testes laboratoriais existentes, se destaca o teste de Ellestad, devido à sua segurança e capacidade diagnóstica de patologias cardíacas. Dentre os testes de campo se destaca o teste de Vai e Vem de 20m (VV20m), devido à sua alta validade e reprodutibilidade em adultos, e devido à alta especificidade ao futsal e ao futebol, comprovado pela existênicia de correlações significativas do desempenho no VV20m com várias medidas de performance no futebol. Porém, não existem estudos sobre a validação ou concordância do teste de Ellestad em atletas de esportes coletivos. Portanto, o objetivo do presente estudo foi testar a concordância do teste de Ellestad e o VV20m na predição do VO2max em atletas de futsal. Quinze jogadores semi-profissionais (25,4 ± 5,51 anos, 70,37 ± 5,74kg, 1,75 ± 0,04m e 8,43 ± 3,02% de gordura) realizaram os testes de Ellestad e o VV20m em ordens aleatórias, separados por quatro dias. A concordância foi testada pela comparação entre as diferenças (Teste t-studet para dados independentes), correlação (coeficiente de Pearson) e concordância (dipersão de Bland e Altman). Não houve diferença significativa entre os valores de VO2max estimados pelos dois protocolos, mas a correlação foi significativa (p < 0,05; r = 0,479; EPE: 1,8 mlO2×kg -1 ×min -1 ) entre os métodos. A análise de Bland e Altman apresentou concordância entre os testes para um intervalo de ±95% em torno da média da diferença (1,3 mlO2×kg -1 ×min -1 ), porém a dispersão indica um enviesamento positivo e significativo (p < 0,01), sugerindo que a a diferença aumenta com o aumento da média do VO2max. Assim, para atletas de alto rendimento, o teste de Ellestad não apresenta a mesma adequação na determinação do VO2max, quando comparado ao VV20m.
Resumo:
Brazil is a country of continental dimensions with a large heterogeneity of climates and massive mixing of the population. Almost the entire national territory is located between the Equator and the Tropic of Capricorn, and the Earth axial tilt to the south certainly makes Brazil one of the countries of the world with greater extent of land in proximity to the sun. The Brazilian coastline, where most of its population lives, is more than 8,500 km long. Due to geographic characteristics and cultural trends, Brazilians are among the peoples with the highest annual exposure to the sun. Epidemiological data show a continuing increase in the incidence of non-melanoma and melanoma skin cancers. Photoprotection can be understood as a set of measures aimed at reducing sun exposure and at preventing the development of acute and chronic actinic damage. Due to the peculiarities of Brazilian territory and culture, it would not be advisable to replicate the concepts of photoprotection from other developed countries, places with completely different climates and populations. Thus the Brazilian Society of Dermatology has developed the Brazilian Consensus on Photoprotection, the first official document on photoprotection developed in Brazil for Brazilians, with recommendations on matters involving photoprotection.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Este estudo relacionou a frequência da emissão de reação socialmente habilidosa, não-habilidosa passiva e não-habilidosa ativa às variáveis da criança (sexo, idade, condições clínicas). Participaram 57 meninos e 52 meninas, entre seis e 12 anos. O Questionário de Caracterização da Criança (QCC) levantou informações sobre sexo, idade e condições clínicas e o Inventário Multimídia de Habilidades Sociais de Crianças (IMHSC-Del Prette) avaliou as habilidades sociais, respondidos pelos cuidadores e escolares, respectivamente. Utilizou-se os testes U de Mann-Whitney, o coeficiente de correlação de Pearson e o teste t para análises dos dados. Os resultados indicaram: (a) diferenças significativas na adequação das reações habilidosas e não-habilidosas (p < 0,001); (b) aumento do repertório de habilidades sociais conforme o avançar dos anos (p < 0,001); e (c) meninas apresentaram mais frequência de habilidades sociais que meninos (p = 0,040). Não houve associações significativas entre habilidades sociais e condições clínicas (p = 0,539). Verificou-se que sexo e idade podem interferir na presença e desempenho de repertório socialmente habilidoso. Sugerem-se outras técnicas de avaliação que complementem os dados investigados e possibilitem intervenções futuras para amostras semelhantes.
Resumo:
Objetivou-se descrever as rotinas de três famílias, que adotaram crianças com necessidades especiais, que tinham conhecimento prévio dessa condição infantil. Utilizou-se o método de Estudo de Casos Múltiplos. Os dados foram obtidos por meio de Entrevista Semiestruturada (ES), do Inventário de Rotina (IR) e do Diário de Campo (DC). Quanto às semelhanças entre os grupos familiares, identificou-se que são comuns as atividades de alimentação/higiene, descanso e lazer, envolvendo a participação dos pais, irmãs e babás, geralmente nos ambientes domésticos da família. Observou-se diferenças importantes nos padrões de atividades, companhias e ambientes onde as rotinas ocorriam. Conclui-se que as variações nas rotinas estão relacionadas às particularidades de cada criança, à estrutura e nível socioeconômico de cada família participante.
Resumo:
In this issue: Beach House Raffle Planned "The End of the Affair" -- Dean Herring Note From the Chair: "Reflections on Reading"-- Dr. Jane J. White Membership Form
Resumo:
“Our study will show how the pyramidal structure as a permanent feature of every aspect of American society continues to function in the same manner at institutions of higher learning.”
Resumo:
Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.
Resumo:
Background and Study Aim: The grip strength endurance is important for Brazilian Jiu-Jitsu (BJJ). Thus, the aims of this study were: a) to test the reliability of two kimono grip strength tests named maximum static lift (MSL) and maximum number of repetitions (MNR) and b) to examine differences between elite and non-elite BJJ players in these tests. Material/Methods: Thirty BJJ players participated into two phases: "A" to test reliability and "B" to compare elite and non-elite. In phase A, twenty participants performed the MSL and, 15 min later, the MNR in two occasions with 24-h interval. In phase B, ten other BJJ practitioners (non-elite) and ten athletes (elite) performed the same tests. The intraclass correlation coefficient (ICC) two way fixed model (3,1), Bland-Altman plot and the limits of agreement were used to test reliability, correlation between the tests were evaluated by Pearson correlations and independent T test (P<0.05) was utilized to compare elite vs. non-elite. Results: The ICC was high for repeated measurements on different days of phase A (MSL: r=0.99 and MNR: r=0.97). Limits of agreement for time of suspension were -6.9 to 2.4-s, with a mean difference of -2.3 s (CI: -3.3 to -1.2-s), while for number of repetitions the limits of agreement were -2.9 to 2.3-rep, with a mean difference of -0.3-rep (CI: -0.9 to 0.3-rep). In phase B, elite presented better performance for both tests (P<0.05) compared to non-elite (56 +/- 10-s vs. 37 +/- 11-s in MSL and 15 +/- 4-rep vs. 8 +/- 3-rep in MNR). Moderate correlation were found between MSL and MNR for absolute values during test (r=0.475; p=0.034), and retest phases (r=0.489; p=0.029), while moderate and high correlations in the test (r=0.615; p=0.004) and retest phases (r=0.716; p=0.001) were found for relative values, respectively. Conclusions: These proposed tests are reliable and both static and dynamic grip strength endurance tests seem to differentiate BJJ athletes from different levels.
Resumo:
Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.
Resumo:
Objective: To translate, culturally adapt and validate the "Knee Society Score"(KSS) for the Portuguese language and determine its measurement properties, reproducibility and validity. Method: We analyzed 70 patients of both sexes, aged between 55 and 85 years, in a cross-sectional clinical trial, with diagnosis of primary osteoarthritis,undergoing total knee arthroplasty surgery. We assessed the patients with the English version of the KSS questionnaire and after 30 minutes with the Portuguese version of the KSS questionnaire, done by a different evaluator. All the patients were assessed preoperatively, and again at three, and six months postoperatively. Results: There was no statistical difference, using Cronbach's alpha index and the Bland-Altman graphical analysis, for the knees core during the preoperative period (p=1), and at three months (p=0.991) and six months postoperatively (p=0.985). There was no statistical difference for knee function score for all three periods (p=1.0). Conclusion: The Brazilian version of the Knee Society Score is easy to apply, as well providing as a valid and reliable instrument for measuring the knee score and function of Brazilian patients undergoing TKA. Level of Evidence: Level I - Diagnostic Studies Investigating a Diagnostic Test- Testing of previously developed diagnostic criteria on consecutive patients (with universally applied 'gold' reference standard).
Resumo:
STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101
Resumo:
Objectives: Cardiac surgery (CC) determines systemic and pulmonary changes that require special care. What motivated several studies conducted in healthy subjects to assess muscle strength were the awareness of the importance of respiratory muscle dysfunction in the development of respiratory failure. These studies used maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) values. This study examined the concordance between the values predicted by the equations proposed by Black & Hyatt and Neder, and the measured values in cardiac surgery (CS) patients. Methods: Data were collected from preoperative evaluation forms. The Lin coefficient and Bland-Altman plots were used for statistical concordance analysis. The multiple linear regression and analysis of variance (ANOVA) were used to produce new formulas. Results: There were weak correlations of 0.22 and 0.19 in the MIP analysis and of 0.10 and 0.32 in the MEP analysis, for the formulas of Black & Hyatt and Neder, respectively. The ANOVA for both MIP and MEP were significant (P <0.0001), and the following formulas were developed: MIP = 88.82 - (0.51 x age) + (19.86 x gender), and MEP = 91.36 -(030 x age) + (29.92 x gender). Conclusions: The Black and Hyatt and Neder formulas predict highly discrepant values of MIP and MEP and should not be used to identify muscle weakness in CS patients.
Resumo:
Atherosclerosis and vascular calcification (VC) progression in chronic kidney disease is favored by disturbances of mineral metabolism. We compared the effect of phosphate binder lanthanum (La) carbonate with sevelamer-HCl on atherosclerosis, VC and bone structure and function in mice with chronic renal failure (CRF). Apolipoprotein E-deficient (apoE(-/-)) mice were randomized to one non-CRF and three CRF groups, fed with standard diet (one non-CRF and one CRF) or diet supplemented with either 3% lanthanum carbonate (La3%) or 3% sevelamer-HCl (Sev3%). Both La3% and Sev3% supplemented CRF mice displayed a decrease of serum phosphorus, calcification at both intimal and medial aortic sites and atherosclerosis. This was associated with a reduction of plaque Type I collagen expression by both binders and of positive nitrotyrosine staining in response to sevelamer-HCl only. Increased mineral apposition and bone formation rates in unsupplemented CRF mice were reduced by Sev3% but not by La3%. The beneficial effects of La carbonate and sevelamer-HCl on the progression of VC and atherosclerosis in CRF mice could be mainly due to a decrease in phosphate retention and likewise a reduction of arterial Type I collagen expression. The effect of La carbonate differed from that of sevelamer-HCl in that it did not appear to exert its vascular effects via changes in oxidative stress or bone remodeling in the present model.