941 resultados para helical twist angle
Resumo:
The uplift capacity of helical anchors normally increases with the number of helical plates. The rate of capacity gain is variable, considering that the disturbance caused by the anchor installation is generally more pronounced in the soil mass above the upper plates than above the lower plates, because the upper soil layers are penetrated more times. The present investigation examines the effect of the number of helices on the performance of helical anchors in sand, based on the results of centrifuge model tests. Uplift loading tests were performed on 12 different types of piles installed in two containers of dry sand prepared with different densities. The measured fractions of the uplift capacity related to each individual helical plate of multi-helix anchors were compared with the fractions predicted by the individual bearing method. The results of this investigation indicate that in double- and triple-helix anchors, the contributions of the second and third plate to the total anchor uplift capacity decreased with the increase of sand relative density and plate diameter. In addition, these experiments demonstrated that the variation of the anchor load-displacement behavior with the number of helices also depends on these parameters.
Resumo:
The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.
Resumo:
Objective: To assess the effects produced by the MARA appliance in the treatment of Angle’s Class II, division 1 malocclusion. Methods: The sample consisted of 44 young patients divided into two groups: The MARA Group, with initial mean age of 11.99 years, treated with the MARA appliance for an average period of 1.11 years, and the Control Group, with initial mean age of 11.63 years, monitored for a mean period of 1.18 years with no treatment. Lateral cephalograms were used to compare the groups using cephalometric variables in the initial and final phases. For these comparisons, Student’s t test was employed. Results: MARA appliance produced the following effects: Maxillary growth restriction, no change in mandibular development, improvement in maxillomandibular relationship, increased lower anterior facial height and counterclockwise rotation of the functional occlusal plane. In the upper arch, the incisors moved lingually and retruded, while the molars moved distally and tipped distally. In the lower arch, the incisors proclined and protruded, whereas the molars mesialized and tipped mesially. Finally, there was a significant reduction in overbite and overjet, with an obvious improvement in molar relationship. Conclusions: It was concluded that the MARA appliance proved effective in correcting Angle’s Class II, division 1 malocclusion while inducing skeletal changes and particularly dental changes.
Resumo:
Objective: This study evaluated the variations in the anterior cranial base (S-N), posterior cranial base (S-Ba) and deflection of the cranial base (SNBa) among three different facial patterns (Pattern I, II and III). Method: A sample of 60 lateral cephalometric radiographs of Brazilian Caucasian patients, both genders, between 8 and 17 years of age was selected. The sample was divided into 3 groups (Pattern I, II and III) of 20 individuals each. The inclusion criteria for each group were the ANB angle, Wits appraisal and the facial profile angle (G’.Sn.Pg’). To compare the mean values obtained from (SNBa, S-N, S-Ba) each group measures, the ANOVA test and Scheffé’s Post-Hoc test were applied. Results and Conclusions: There was no statistically significant difference for the deflection angle of the cranial base among the different facial patterns (Patterns I, II and III). There was no significant difference for the measures of the anterior and posterior cranial base between the facial Patterns I and II. The mean values for S-Ba were lower in facial Pattern III with statistically significant difference. The mean values of S-N in the facial Pattern III were also reduced, but without showing statistically significant difference. This trend of lower values in the cranial base measurements would explain the maxillary deficiency and/or mandibular prognathism features that characterize the facial Pattern III.
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
Resumo:
OBJECTIVE: Define and compare numbers and types of occlusal contacts in maximum intercuspation. METHODS: The study consisted of clinical and photographic analysis of occlusal contacts in maximum intercuspation. Twenty-six Caucasian Brazilian subjects were selected before orthodontic treatment, 20 males and 6 females, with ages ranging between 12 and 18 years. The subjects were diagnosed and grouped as follows: 13 with Angle Class I malocclusion and 13 with Angle Class II Division 1 malocclusion. After analysis, the occlusal contacts were classified according to the established criteria as: tripodism, bipodism, monopodism (respectively, three, two or one contact point with the slope of the fossa); cuspid to a marginal ridge; cuspid to two marginal ridges; cuspid tip to opposite inclined plane; surface to surface; and edge to edge. RESULTS: The mean number of occlusal contacts per subject in Class I malocclusion was 43.38 and for Class II Division 1 malocclusion it was 44.38, this difference was not statistically significant (p>0.05). CONCLUSIONS: There is a variety of factors that influence the number of occlusal contacts between a Class I and a Class II, Division 1 malocclusion. There is no standardization of occlusal contact type according to the studied malocclusions. A proper selection of occlusal contact types such as cuspid to fossa or cuspid to marginal ridge and its location in the teeth should be individually defined according to the demands of each case. The existence of an adequate occlusal contact leads to a correct distribution of forces, promoting periodontal health.
Resumo:
Questo progetto di ricerca, è stato sviluppato per studiare le caratteristiche anatomofunzionali che definiscono l’articolazione del gomito, ed in modo articolare la presenza dell’angolazione valga che origina dalla diversa orientazione degli assi meccanici dell’avambraccio e del braccio e, denominata in letteratura come carrying angle. L’obiettivo principale di questo lavoro - meglio espresso nei diversi capitoli - è stato, quello di identificare un nuovo approccio di misura per la stima di questo angolo, utilizzabile sia per gli studi di biomeccanica articolare, che per gli studi di analisi del movimento per l’arto superiore. Il primo obiettivo è stato quello di scegliere un algoritmo di calcolo che rispettasse le caratteristiche dell’articolazione, ed in modo particolare abile a minimizzare gli errori introdotti sia nella fase di acquisizione dei punti di repere anatomici, che in quella legata alla predizione del movimento di flesso-estensione, con un modello matematico. Per questo motivo abbiamo dovuto realizzare una serie di misure in un primo tempo su due cadaveri di arto superiore, poi, seguendo le regole classiche per la validazione dell’approccio metodologico adottato, si sono realizzate misure in-vivo, prima in massima estensione e poi durante il movimento. Inizialmente abbiamo pensato di comparare le misure lineari relative alle ampiezze del braccio (ampiezza tra l’epicondilo laterale e mediale) e dell’avambraccio (ampiezza tra lo stiloide ulnare e radiale) con quelle ottenute mediante un antropometro; successivamente dopo aver verificato la ripetibilità tra i diversi operatori nell’ acquisizione dei punti di repere anatomici con il digitalizzatore Faro Arm, abbiamo comparato le misure ottenute relative al carrying angle con quelle di un goniometro standard, classicamente utilizzato nella pratica clinica per la definizione dei range di movimento dell’arto superiore. Infine, considerando la bontà delle misure ottenute, abbiamo riproposto tale metodologia con stumenti stereofotogrammetrici per l’analisi del movimento (VICON System), ottenendo la stessa stabilit`a nell’andamento del carrying angle in funzione della flessione, sia come riportato dagli studi in letteratura, sia come riscontrato nel nostro studio in-vitro. In conclusione, questo lavoro di ricerca ha evidenziato (sia per i risultati ottenuti, che per la elevata numerosità dei soggetti testati), come gli esseri umani presentino una grande variabilità individuale nel valore di questo angolo, e di come questo possa aiutare per la corretta definizione di un modello 3-D dell’arto superiore. Pertanto, gli studi futuri sulla biomeccanica dell’arto superiore dovrebbero includere sempre la valutazione di questa misura.
Resumo:
[EN]When analysing the seismic response of pile groups, a vertically-incident wavefiel is usually employed even though it doesnot necessarily correspond to the worst case scenario. This work aims to study the influence of both type of seismic body wave and its angle of incidence on the dynamic response of pile foundations.
Resumo:
[EN] This paper aims to contribute to clarify whether the use of battered piles has a positive or negative influence on the dynamic response of deep foundations and superstructures. For this purpose, the dynamic response of slender and non-slender structures supported on several configurations of 2X2 and 3X3 pile groups including battered elements is obtained through a procedure based on a substructuring model whick takes soil-structure interaction into account.
Resumo:
Zusammenfassung Um zu einem besseren Verständnis des Prozesses der Biomineralisation zu gelangen, muss das Zusammenwirken der verschiedenen Typen biologischer Makromoleküle, die am Keimbildungs- und Wachstumsprozess der Minerale beteiligt sind, berücksichtigt werden. In dieser Arbeit wird ein neues Modellsystem eingeführt, das aus einem SAM (self-assembled monolayer) mit verschiedenen Funktionalitäten und unterschiedlichen, gelösten Makromolekülen besteht. Es konnte gezeigt werden, dass die Kristallisation von Vaterit (CaCO3) sowie Strontianit (SrCO3) Nanodrähten der Präsenz von Polyacrylat in Kooperation mit einer COOH-funktionalisierten SAM-Oberfläche zugeschrieben werden kann. Die Kombination bestehend aus einer polaren SAM-Oberfläche und Polyacrylat fungiert als Grenzfläche für die Struktur dirigierende Kristallisation von Nanodraht-Kristallen. Weiter konnte gezeigt werden, dass die Phasenselektion von CaCO3 durch die kooperative Wechselwirkung zwischen einer SAM-Oberfläche und einem daran adsorbierten hb-Polyglycerol kontrolliert wird. Auch die Funktionalität einer SAM-Oberfläche in Gegenwart von Carboxymethyl-cellulose übt einen entscheidenden Einfluss auf die Phasenselektion des entstehenden Produktes aus. In der vorliegenden Arbeit wurden Untersuchungen an CaCO3 zur homogenen Keimbildung, zur Nukleation in Gegenwart eines Proteins sowie auf Kolloiden, die als Template fungieren, mittels Kleinwinkel-Neutronenstreuung durchgeführt. Die homogene Kristallisation in wässriger Lösung stellte sich als ein mehrstufiger Prozess heraus. In Gegenwart des Eiweißproteins Ovalbumin konnten drei Phasen identifiziert werden, darunter eine anfänglich vorhandene amorphe sowie zwei kristalline Phasen.
Resumo:
In this work, solid-state NMR methods suitable for the investigation of supramolecular systems were developed and improved. In this context, special interest was focussed on non-covalent interactions responsible for the formation of supramolecular structures, such as pi-pi interacions and hydrogen-bonds. In the first part of this work, solid-state NMR methods were presented that provide information on molecular structure and motion via the investigation of anisotropic interactions, namely quadrupole and dipole-dipole couplings, under magic-angle spinning conditions. A two-dimensional 2H double quantum experiment was developed, which is performed under off magic-angle conditions and correlates 2H isotropic chemical shifts with quasistatic DQ-filtered line shapes. From the latter, the quadrupole coupling parameters of samples deuterated at multiple sites can be extracted in a site-selective fashion. Furthermore, 7Li quadrupole parameters of lithium intercalated into TiO2 were determined by NMR experiments performed under static and MAS conditions, and could provide information on the crystal geometry. For the determination of 7Li-7Li dipole-dipole couplings, multiple-quantum NMR experiments were performed. The 1H-13C REREDOR experiment was found to be capable of determining strong proton-carbon dipole-dipole couplings with an accuracy of 500~Hz, corresponding to a determination of proton-carbon chemical-bond lengths with picometer accuracy In the second part of this work, solid-state NMR experiments were combined with quantum-chemical calculations in order to aid and optimise the interpretation of experimental results. The investigations on Calix[4]hydroquinone nanotubes have shown that this combined approach can provide information on the presence of disordered and/or mobile species in supramolecular structures. As a second example, C3-symmetric discs arranging in helical columnar stacks were investigated. In these systems, 1H chemical shifts experience large pi-shifts due to packing effects, which were found to be long-ranged. Moreover, quantum-chemical calculations revealed that helicity in these systems is induced by the propeller-like conformation of the core of the molecules.
Resumo:
Il tumore al seno è il più comune tra le donne nel mondo. La radioterapia è comunemente usata dopo la chirurgia per distruggere eventuali cellule maligne rimaste nel volume del seno. Nei trattamenti di radioterapia bisogna cercare di irradiare il volume da curare limitando contemporaneamente la tossicità nei tessuti sani. In clinica i parametri che definiscono il piano di trattamento radioterapeutico sono selezionati manualmente utilizzando un software di simulazione per trattamenti. Questo processo, detto di trial and error, in cui i differenti parametri vengono modificati e il trattamento viene simulato nuovamente e valutato, può richiedere molte iterazioni rendendolo dispendioso in termini di tempo. Lo studio presentato in questa tesi si concentra sulla generazione automatica di piani di trattamento per irradiare l'intero volume del seno utilizzando due fasci approssimativamente opposti e tangenti al paziente. In particolare ci siamo concentrati sulla selezione delle direzioni dei fasci e la posizione dell'isocentro. A questo scopo, è stato investigata l'efficacia di un approccio combinatorio, nel quale sono stati generati un elevato numero di possibili piani di trattamento utilizzando differenti combinazioni delle direzioni dei due fasci. L'intensità del profilo dei fasci viene ottimizzata automaticamente da un algoritmo, chiamato iCycle, sviluppato nel ospedale Erasmus MC di Rotterdam. Inizialmente tra tutti i possibili piani di trattamento generati solo un sottogruppo viene selezionato, avente buone caratteristiche per quel che riguarda l'irraggiamento del volume del seno malato. Dopo di che i piani che mostrano caratteristiche ottimali per la salvaguardia degli organi a rischio (cuore, polmoni e seno controlaterale) vengono considerati. Questi piani di trattamento sono matematicamente equivalenti quindi per selezionare tra questi il piano migliore è stata utilizzata una somma pesata dove i pesi sono stati regolati per ottenere in media piani che abbiano caratteristiche simili ai piani di trattamento approvati in clinica. Questo metodo in confronto al processo manuale oltre a ridurre considerevol-mente il tempo di generazione di un piano di trattamento garantisce anche i piani selezionati abbiano caratteristiche ottimali nel preservare gli organi a rischio. Inizialmente è stato utilizzato l'isocentro scelto in clinica dal tecnico. Nella parte finale dello studio l'importanza dell'isocentro è stata valutata; ne è risultato che almeno per un sottogruppo di pazienti la posizione dell'isocentro può dare un importante contributo alla qualità del piano di trattamento e quindi potrebbe essere un ulteriore parametro da ottimizzare.
Resumo:
The aim of this Thesis is to obtain a better understanding of the mechanical behavior of the active Alto Tiberina normal fault (ATF). Integrating geological, geodetic and seismological data, we perform 2D and 3D quasi-static and dynamic mechanical models to simulate the interseismic phase and rupture dynamic of the ATF. Effects of ATF locking depth, synthetic and antithetic fault activity, lithology and realistic fault geometries are taken in account. The 2D and 3D quasi-static model results suggest that the deformation pattern inferred by GPS data is consistent with a very compliant ATF zone (from 5 to 15 km) and Gubbio fault activity. The presence of the ATF compliant zone is a first order condition to redistribute the stress in the Umbria-Marche region; the stress bipartition between hanging wall (high values) and footwall (low values) inferred by the ATF zone activity could explain the microseismicity rates that are higher in the hanging wall respect to the footwall. The interseismic stress build-up is mainly located along the Gubbio fault zone and near ATF patches with higher dip (30°
Twist and shout: one decade of meta-analyses of erythropoiesis-stimulating agents in cancer patients
Resumo:
Anemia associated with cancer and cancer therapy is a common and important issue in the treatment of patients with malignant disease. Conventionally, blood transfusions are used to treat severe cancer-related anemia. Short- and long-acting preparations of recombinant human erythropoiesis-stimulating agents (ESAs) offer an alternative treatment option. Multiple studies and subsequent meta-analyses have demonstrated that ESA treatment increases hemoglobin levels and reduces the likelihood of transfusion for a proportion of treated patients. However, studies that attempted to evaluate whether ESAs improve tumor response and survival have generated conflicting evidence. Results of smaller trials reporting improved survival outcomes were contradicted by large randomized controlled trials that reported more deaths in patients receiving ESAs. In addition, there is strong evidence that cancer patients receiving ESAs have an increased risk of thromboembolic and cardiovascular events. We herein review the main meta-analyses published in the field, their strengths and weaknesses, their contribution to patient management and future perspectives for systematic reviews.
Resumo:
Intrapartum translabial ultrasound (ITU) has the potential to objectively and quantitatively assess the progress of labour. The relationships between the different ITU parameters and their development during normal term labour have not been studied.