977 resultados para grafene, grafite, microscopia, forza, atomica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we deposit via non-reactive magnetron sputtering of radio-frequency nanofilmes of nitreto of aluminum(AlN). The nanofilms aluminum nitride are semiconductors materials with high thermal conductivity, high melting point, piezoelectricity and wide band gap (6, 2 eV) with hexagonal wurtzite crystal structure, belonging to the group of new materials called III-V nitrides in which together with the gallium nitride and indium nitride have attracted much interest because they have physical and chemical properties relevant to new technological applications, mainly in microelectronic and optoelectronic devices. Three groups were deposited with thicknesses nanofilms time dependent on two substrates (glass and silicon) at a temperature of 25 ° C. The nanofilms AlN were characterized using three techniques, X-ray diffraction, Raman spectroscopy and atomic force microscopy (AFM), examined the morphology of these. Through the analysis of X-rays get the thickness of each sample with its corresponding deposition rate. The analysis of X-rays also revealed that nanofilms are not crystalline, showing the amorphous character of the samples. The results obtained by the technique, atomic force microscopy (AFM) agree with those obtained using the technique of X-rays. Characterization by Raman spectroscopy revealed the existence of active modes characteristic of AlN in the samples

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study will show the capability of the reactive/nonreactive sputtering (dc/rf) technique at low power for the growth of nanometric thin films from magnetic materials (FeN) and widegap semiconductors (AlN), as well as the technological application of the Peltier effect using commercial modules of bismuth telluride (Bi2Te3). Of great technological interest to the high-density magnetic recording industry, the FeN system represents one of the most important magnetic achievements; however, diversity of the phases formed makes it difficult to control its magnetic properties during production of devices. We investigated the variation in these properties using ferromagnetic resonance, MOKE and atomic force microscopy (AFM), as a function of nitrogen concentration in the reactive gas mixture. Aluminum nitride, a component of widegap semiconductors and of considerable interest to the electronic and optoelectronic industry, was grown on nanometric thin film for the first time, with good structural quality by non-reactive rf sputtering of a pure AlN target at low power (≈ 50W). Another finding in this study is that a long deposition time for this material may lead to film contamination by materials adsorbed into deposition chamber walls. Energy-dispersive X-ray (EDX) analysis shows that the presence of magnetic contaminants from previous depositions results in grown AlN semiconductor films exhibiting magnetoresistance with high resistivity. The Peltier effect applied to commercially available compact refrigeration cells, which are efficient for cooling small volumes, was used to manufacture a technologically innovative refrigerated mini wine cooler, for which a patent was duly registered

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho tem como objetivo estudar a influência da adição de diversos aditivos tais como óxido de silício (SiO2), óxido de bismuto (BiO2), óxido de cério (CeO2) e óxido de lantânio (La2O3) nas propriedades elétricas e dielétricas do titanato de bário (BaTiO3) policristalino. As amostras de titanato de bário foram compactadas e sinterizadas no Laboratório de Tecnologia dos Pós, do Departamento de Física da Universidade Federal do Rio Grande do Norte. Foram realizadas medidas de resistividade elétrica e constante dielétrica em função da temperatura, bem como ensaios de difração de raios-X e análise microestrutural através da microscopia eletrônica de varredura. A análise dos resultados permitiu avaliar a influência dos aditivos nas propriedades elétricas e dielétricas, e propor a utilização de cerâmicas eletrônicas a base de titanato de bário com propriedades superiores as do material existente atualmente

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work we use a plasma jet system with a hollow cathode to deposit thin TiO2 films on silicon substrates as alternative at sol-gel, PECVD, dip-coating e magnetron sputtering techniques. The cylindrical cathode, made from pure titanium, can be negatively polarized between 0 e 1200 V and supports an electrical current of up to 1 A. An Ar/O2 mixture, with a total flux of 20 sccm and an O2 percentage ranging between 0 and 30%, is passed through a cylindrical hole machined in the cathode. The plasma parameters and your influence on the properties of deposited TiO2 films and their deposition rate was studied. When discharge occurs, titanium atoms are sputtered/evaporated. They are transported by the jet and deposited on the Si substrates located on the substrate holder facing the plasma jet system at a distance ranging between10 and 50 mm from the cathode. The working pressure was 10-3 mbar and the deposition time was 10 -60 min. Deposited films were characterized by scanning electron microscopy and atomic force microscopy to check the film uniformity and morphology and by X-ray diffraction to analyze qualitatively the phases present. Also it is presented the new dispositive denominate ionizing cage, derived from the active screen plasma nitriding (ASPN), but based in hollow cathode effect, recently developed. In this process, the sample was involved in a cage, in which the cathodic potential was applied. The samples were placed on an insulator substrate holder, remaining in a floating potential, and then it was treated in reactive plasma in hollow cathode regime. Moreover, the edge effect was completely eliminated, since the plasma was formed on the cage and not directly onto the samples and uniformity layer was getting in all sampl

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A estrutura dos dúctulos eferentes no epidídimo do cão foi estudada através de microscopia óptica. Os dúctulos eferentes conectam a rede testicular com o segmento inicial do epidídimo. Os eferentes epididimários são revestidos por epitélio baixo do tipo cúbico ou cilíndrico simples, constituído por dois tipos celulares: células ciliadas e não-ciliadas. As características morfológicas dos eferentes são discutidas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Iron nitrite films, with hundred of nanometers thick, were deposited using the Cathodic cage plasma nitriding method, with a N2/H2 plasma, over a common glass substract. The structure, surface morphology and magnetic properties were investigated using X-ray diffractometry (XRD), atomic force microscopy (AFM) and vibrating sample magnetometer (VSM). XRD shows the formation of γ FeN phase and a combination of ζFe2N + ɛFe3N phases. The film s saturation magnetization and coercivity depends on morphology, composition, grain size and treatment temperature. Temperature raising from 250 ºC to 350 ºC were followed by an increase in saturation magnetization and film s surface coercivity on the parallel direction in relative proportion. This fact can be attributed to the grain sizes and to the different phases formed, since iron rich fases, like the ɛFe3N phase, emerges more frequently on more elevated treatment s temperature. Using this new and reasonably low cost method, it was possible to deposit films with both good adhesion and good magnetic properties, with wide application in magnetic devices

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oral and facial bone defects can undertake appearance, psychosocial well-being and stomathognatic function of its patients. Over the yerars several strategies for bone defect regeneration have arised to treat these pathologies, among them the use of frozen and irradiated bone allograft. Manipulation of bone grafts it s not determined yet, and several osteotomy alternatives can be observed. The present work evaluated with a microscope the bone fragments obtained from different osteotomy methods and irrigation on rings and blocks allografts irradiated and frozen at 80° negative in a rabbit model. The study is experimental in vitro and it sample was an adult male New Zealand rabbit. The animal was sacrificed to obtain long bones, that were submitted to freezing at 80º negative and irradiated with Cobalt- 60. Then the long bones were sectioned into 24 bone pieces, divided into 4 groups: G1 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thickness with high-speed handpiece with manual irrigation; G2 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thick with surgical motor with a manual irrigation rotation 1500 rpm; GA (n=06), osteotomy with trephine using manual irrigation with saline; and GB (n=06), osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear Layer were evaluated. Analyzing osteotomy technics on SEM was observed: increased presence of microcracks cutting with high speed; increased presence of areas covered by Smear Layer when cutting with motor implant. The irrigation analysis with SEM was observed: that the presence of microcracks does not depend on the type of irrigation; on manual irrigation, there was greater discrepancy between the cutting lines. The descriptive analysis of the osteotomy and irrigation process on LM showed: histological analysis showing the bony margins with clear tissue changed layer, composed of blackened tissue of charred appearance near to the cortical bone; on the edges of the bony part, bone fragments that were displaced during the bone cut and bone irregularities were observed. After analysis of results we can conclude: that there was greater regularity of the bone cut using high-speed handpiece than using motor implant; the cut with trephine using saline irrigated from peristaltic pumps of surgical motor showed greater homogeneity when compared with manual irrigation; charred tissue was found in all obtained bone samples, whit no significant statistically difference on the proportion of carbonization of the two analysed technics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo a Pesquisa do Estado de São Paulo

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esse estudo se propôs a avaliar um método auxiliar de diagnóstico (DIAGNOdent®) na predição de cárie de dentina em dentes decíduos, através de validação histológica e de microdureza. Verificando possíveis diferenças entre os valores obtidos através do método auxiliar, além de determinar um ponto de corte para parada de remoção de tecido cariado. A amostra do estudo foi de 15 crianças que apresentaram 21 cavidades de cárie, tratadas e analisadas desde antes da realização da restauração até quando da exodontia do elemento dentário. Os espécimes foram analisados através do DIAGNOdent® antes da abertura das cavidades, após a remoção do tecido cariado e depois da reabertura das cavidades que se deu após a exodontia dos elementos dentários. Posteriormente, receberam preparo metalográfico para realização de testes de microdureza e microscopia óptica que serviram como forma de validação para as mensurações obtidas pela fluorescência a laser. Houve diferença significativa entre os valores DIAGNOdent® encontrados antes da abertura da cavidade e os demais (p < 0,0001). Havendo correlação significativa (r = 0,432 ; p = 0,019) apenas para as aferições obtidas antes da abertura das cavidades e quando do término da remoção do tecido cariado. Para a microdureza, as médias axiais foram significativamente maiores que as pulpares, existindo correlação entre a microdureza pulpar e os valores do DIAGNOdent® após a reabertura (r = - 0,472 ; p = 0,002). Valores de 15,38% para a sensibilidade, 100% para a especificidade, 100% para o valor preditivo positivo e 71,79% para o valor preditivo negativo, foram obtidos quando se utilizou um ponto de corte de 30 para fluorescência a laser, tendo como padrão-ouro a microdureza pulpar. Partindo da média dos valores de fluorescência a laser obtidos após a remoção do tecido cariado e acrescentando-se um desvio-padrão a esta, o método indicou o valor de 19 como ponto de corte para cessar a remoção de dentina. Concluiu-se que, nas condições analisadas, o método auxiliar de diagnóstico (DIAGNOdent®) é um método acurado na predição de cárie de dentina em dentes decíduos. Além disso, o método comprovou que o padrão usual de remoção de dentina garante a remoção do tecido cariado

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The radicular cysts (RCs) and dentigerous (DCs), despite having different etiologies, form a pathological cavity lined by epithelium, which grows due to the buildup of fluid inside, as the surrounding bone is reabsorbed and the epithelium will being induced to proliferate. The epithelial proliferation, which has been identified as one of the key processes in the growth of odontogenic cystic lesions, is influenced by growth factors such as EGFR (epidermal growth receptor factor) and podoplanin (PDPN), many of which may have its production stimulated mainly during inflammatory processes. The objective of this research was to evaluate and compare the immunohistochemical expression of EGFR and PDPN in 30 cases of RCs and 30 cases of DCs, semiquantitatively, in light microscopy, associating it with the degree of inflammation, cellular localization of immunostaining and with the immunostained epithelial layers. Data were statistically analyzed by Chi-square test and Fisher exact test, considering a significance level of 5 %. The results showed high immunoreactivity of both proteins in the lesions studied, only statistically significant difference was observed in immunostaining of PDPN (p=0.033), which proved higher in RCs. The other analyzed parameters showed no relevant significant differences. We conclude that, as EGFR and PDPN showed high immunoreactivity in cystic lesions analyzed, these proteins participate the pathogenesis of these lesions through the epithelial stimulation process, despite having different etiologies. Furthermore, it can infer that the higher immunostaining of PDNP in RCs that DCs showed no distinction indicator between the two lesions, regarding their etiologies, once this protein also showed a considerable expression in DCs, independent of the intensity of the inflammatory infiltrate

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nas últimas duas décadas, as cerâmicas avançadas têm sido exaustivamente utilizadas em aplicações na indústria devido às suas propriedades de elevada resistência ao desgaste e dureza. Entretanto, ainda se tem um alto custo agregado ao acabamento da peça. Esse acabamento geralmente é feito pelo processo de retificação, único processo economicamente viável que produz superfícies de elevada qualidade e precisão geométrica. Nesse contexto, as empresas vêm buscando a otimização no processo de retificação como, por exemplo, a redução do fluxo de fluido de corte utilizado, o que também visa atender exigências mundiais de preservação ambiental. Desta forma, este projeto pretendeu explorar a técnica da Mínima Quantidade de Lubrificação (MQL) na retificação cilíndrica externa de mergulho em cerâmicas com rebolos diamantados. Foram utilizados dois métodos de refrigeração: o convencional e o MQL, com três avanços de corte para cada caso. Foram usados um bocal convencional e um bocal para o MQL, tendo este um uniformizador de saída do jato. Foram analisadas como variáveis de saída: a emissão acústica, relação G, aspecto da superfície via microscopia eletrônica de varredura (MEV), rugosidade e circularidade. Assim, embora a refrigeração convencional ainda apresente os melhores resultados em comparação com a refrigeração com MQL, esta última pode atender os requisitos necessários para diversas aplicações, em especial quando utilizadas baixas espessuras equivalentes de corte (h eq). Além disso, a técnica de MQL possui a vantagem de gerar um menor impacto ambiental em comparação com a lubrificação convencional, devido ao uso mínimo de fluido de corte cujo descarte é cada vez mais regulamentado e custoso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)