920 resultados para electrochemical windows
Resumo:
Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.
Resumo:
The analysis of opiates is of vital interest in drug abuse monitoring and research. This review presents a general overview of the electrochemical methods used for detection and quantification of opiates in a variety of matrices. Emphasis has been placed on the voltammetric methods used for study and determination of morphine, codeine, and heroin. Specific issues that need to be solved and better explained as well as future trends in the use of electrochemical methods in the examination of opiates are also discussed.
Resumo:
The immobilization and electro-oxidation of guanine and adenine asDNA bases on glassy carbon electrode are evaluated by square wave voltammetric analysis. The influence of electrochemical pretreatments, nature of supporting electrolyte, pH, accumulation time and composition of DNA nucleotides on the immobilization effect and the electrochemical mechanism are discussed. Trace levels of either guanine or adenine can be readily detected following short accumulation time with detection limits of 35 and 40 ngmL−1 for guanine and adenine, respectively. The biosensors of guanine and adenine were employed for the voltammetric detection of antioxidant capacity in flavored water samples. The method relies on monitoring the changes of the intrinsic anodic response of the surface-confined guanine and adenine species, resulting from its interaction with free radicals from Fenton-type reaction in absence and presence of antioxidant. Ascorbic acid was used as standard to evaluate antioxidant capacities of samples. Analytical data was compared with that of FRAP method.
Resumo:
A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.
Resumo:
The electroactivity of butylate (BTL) is studied by cyclic voltammetry (CV) and square wave voltammetry (SWV) at a glassy carbon electrode (GCE) and a hanging mercury drop electrode (HMDE). Britton–Robinson buffer solutions of pH 1.9–11.5 are used as supporting electrolyte. CV voltammograms using GCE show a single anodic peak regarding the oxidation of BTL at +1.7V versus AgCl/ Ag, an irreversible process controlled by diffusion. Using a HMDE, a single cathodic peak is observed, at 1.0V versus AgCl/Ag. The reduction of BTL is irreversible and controlled by adsorption. Mechanism proposals are presented for these redox transformations. Optimisation is carried out univaryingly. Linearity ranges were 0.10–0.50 mmol L-1 and 2.0–9.0 µmolL-1 for anodic and cathodic peaks, respectively. The proposed method is applied to the determination of BTL in waters. Analytical results compare well with those obtained by an HPLC method.
Resumo:
The electrochemical behaviour of propanil and related N-substituted amides (acetanilide and N,N-diphenylacetamide) was studied by cyclic and square wave voltammetry using a glassy carbon electrode. Propanil has been found to have chemical stability under the established analytical conditions and showed an oxidation peak at +1.27V versus Ag/AgCl at pH 7.5. N,N-diphenylacetamide has a higher oxidation potential than the other compounds of +1.49V versus Ag/AgCl. Acetanilide oxidation occurred at a potential similar to that of propanil, +1.24V versus Ag/AgCl. These results are in agreement with the substitution pattern of the nitrogen atom of the amide. A degradation product of propanil, 3,4-dichloroaniline (DCA), was also studied, and showed an oxidation peak at +0.66V versus Ag/AgCl. A simple and specific quantitative electroanalytical method is described for the analysis of propanil in commercial products that contain propanil as the active ingredient, used in the treatment of rice crops in Portugal.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
Two analytical methods for the quality control of dihydrocodeine in commercial pharmaceutical formulations have been developed and compared with reference methods: a square wave voltammetric (SWV) method and a flow injection analysis system with electrochemical detection (FIA-EC). The electrochemical methods proposed were successfully applied to the determination of dihydrocodeine in pharmaceutical tablets and in oral solutions. These methods do not require any pretreatment of the samples, the formulation only being dissolved in a suitable electrolyte. Validation of the methods showed it to be precise, accurate and linear over the concentration range of analysis. The automatic procedure based on a flow injection analysis manifold allows a sampling rate of 115 determinations per hour.
Resumo:
In this paper, a biosensor based on a glassy carbon electrode (GCE) was used for the evaluation of the total antioxidant capacity (TAC) of flavours and flavoured waters. This biosensor was constructed by immobilising purine bases, guanine and adenine, on a GCE. Square wave voltammetry (SWV) was selected for the development of this methodology. Damage caused by the reactive oxygen species (ROS), superoxide radical (O2·−), generated by the xanthine/xanthine oxidase (XOD) system on the DNA-biosensor was evaluated. DNA-biosensor encountered with oxidative lesion when it was in contact with the O2·−. There was less oxidative damage when reactive antioxidants were added. The antioxidants used in this work were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants are capable of scavenging the superoxide radical and therefore protect the purine bases immobilized on the GCE surface. The results demonstrated that the DNA-based biosensor is suitable for the rapid assess of TAC in beverages.
Resumo:
The state of the art of voltammetric and amperometric methods used in the study and determination of pesticides in crops, food, phytopharmaceutical products, and environmental samples is reviewed. The main structural groups of pesticides, i.e., triazines, organophosphates, organochlorides, nitrocompounds, carbamates, thiocarbamates, sulfonylureas, and bipyridinium compounds are considered with some degradation products. The advantages, drawbacks, and trends in the development of voltammetric and amperometric methods for study and determination of pesticides in these samples are discussed.
Resumo:
A utilização massiva da internet e dos serviços que oferece por parte do utilizador final potencia a evolução dos mesmos, motivando as empresas a apostarem no desenvolvimento deste tipo de soluções. Requisitos como o poder de computação, flexibilidade e escalabilidade tornam-se cada vez mais indissociáveis do desenvolvimento aplicacional, o que leva ao surgimento de paradigmas como o de Cloud Computing. É neste âmbito que surge o presente trabalho. Com o objetivo de estudar o paradigma de Cloud Computing inicia-se um estudo sobre esta temática, onde é detalhado o seu conceito, a sua evolução histórica e comparados os diferentes tipos de implementações que suporta. O estudo detalha posteriormente a plataforma Azure, sendo analisada a sua topologia e arquitetura, detalhando-se os seus componentes e a forma como esta mitiga alguns dos problemas mencionados. Com o conhecimento teórico é desenvolvido um protótipo prático sobre esta plataforma, em que se exploram algumas das particularidades da topologia e se interage com as principais redes sociais. O estudo culmina com uma análise sobre os benefícios e desvantagens do Azure e através de um levantamento das necessidades da empresa, determinam-se as oportunidades que a utilização da plataforma poderá proporcionar.
Resumo:
An electrochemical sensor has been developed for the determination of the herbicide bentazone, based on a GC electrode modified by a combination of multiwalled carbon nanotubes (MWCNT) with b-cyclodextrin (b-CD) incorporated in a polyaniline film. The results indicate that the b-CD/MWCNT modified GC electrode exhibits efficient electrocatalytic oxidation of bentazone with high sensitivity and stability. A cyclic voltammetric method to determine bentazone in phosphate buffer solution at pH 6.0, was developed, without any previous extraction, clean-up, or derivatization steps, in the range of 10–80 mmolL 1, with a detection limit of 1.6 mmolL 1 in water. The results were compared with those obtained by an established HPLC technique. No statistically significant differences being found between both methods.
Resumo:
A series of mono(eta(5)-cyclopentadienyl)metal-(II) complexes with nitro-substituted thienyl acetylide ligands of general formula [M(eta(5)-C5H5)(L)(C C{C4H2S}(n)NO2)] (M = Fe, L = kappa(2)-DPPE, n = 1,2; M = Ru, L = kappa(2)-DPPE, 2 PPh3, n = 1, 2; M = Ni, L = PPh3, n = 1, 2) has been synthesized and fully characterized by NMR, FT-IR, and UV-Vis spectroscopy. The electrochemical behavior of the complexes was explored by cyclic voltammetry. Quadratic hyperpolarizabilities (beta) of the complexes have been determined by hyper-Rayleigh scattering (HRS) measurements at 1500 nm. The effect of donor abilities of different organometallic fragments on the quadratic hyperpolarizabilities was studied and correlated with spectroscopic and electrochemical data. Density functional theory (DFT) and time-dependent DFT (TDDFT) calculations were employed to get a better understanding of the second-order nonlinear optical properties in these complexes. In this series, the complexity of the push pull systems is revealed; even so, several trends in the second-order hyperpolarizability can still be recognized. In particular, the overall data seem to indicate that the existence of other electronic transitions in addition to the main MLCT clearly controls the effectiveness of the organometallic donor ability on the second-order NLO properties of these push pull systems.
Resumo:
Human epidermal growth factor receptor 2 (HER2) is a breast cancer biomarker that plays a major role in promoting breast cancer cell proliferation and malignant growth. The extracellular domain (ECD) of HER2 can be shed into the blood stream and its concentration is measurable in the serum fraction of blood. In this work an electrochemical immunosensor for the analysis of HER2 ECD in human serum samples was developed. To achieve this goal a screen-printed carbon electrode, modified with gold nanoparticles, was used as transducer surface. A sandwich immunoassay, using two monoclonal antibodies, was employed and the detection of the antibody–antigen interaction was performed through the analysis of an enzymatic reaction product by linear sweep voltammetry. Using the optimized experimental conditions the calibration curve (ip vs. log[HER2 ECD]) was established between 15 and 100 ng/mL and a limit of detection (LOD) of 4.4 ng/mL was achieved. These results indicate that the developed immunosensor could be a promising tool in breast cancer diagnostics, patient follow-up and monitoring of metastatic breast cancer since it allows quantification in a useful concentration range and has an LOD below the established cut-off value (15 ng/mL).
Resumo:
Recent studies have shown that, besides the well-recognized T3 and T4 hormones, there are other relevant thyroid hormones circulating in the human body. In particular, this is the case for 3-iodothyronamine (T1AM) and thyronamine (T0AM). One of the reasons for the lack of studies showing their precise importance is the absence of analytical methodologies available. Herein, for the first time, T1AM and T0AM are electrochemically characterized. T0AM was sensed by means of a glassy carbon electrode; furthermore, T1AM was sensed both with a graphitic surface (oxidatively) as well as with mercury (reductively). For both compounds, after oxidation, it was possible to observe the reversible redox reaction concerning the benzoquinone/hydroquinone couple, thus increasing the specificity of the electroanalysis. Therefore, this work provides the basis for an ‘at-point-of-use’ electrochemical strip test for T1AM and T0AM.