994 resultados para cation exchange resin
Resumo:
Lineages arriving on islands may undergo explosive evolutionary radiations owing to the wealth of ecological opportunities. Although studies on insular taxa have improved our understanding of macroevolutionary phenomena, we know little about the macroevolutionary dynamics of continental exchanges. Here we study the evolution of eight Carnivora families that have migrated across the Northern Hemisphere to investigate if continental invasions also result in explosive diversification dynamics. We used a Bayesian approach to estimate speciation and extinction rates from a substantial dataset of fossil occurrences while accounting for the incompleteness of the fossil record. Our analyses revealed a strongly asymmetrical pattern in which North American lineages invading Eurasia underwent explosive radiations, whereas lineages invading North America maintained uniform diversification dynamics. These invasions into Eurasia were characterized by high rates of speciation and extinction. The radiation of the arriving lineages in Eurasia coincide with the decline of established lineages or phases of climate change, suggesting differences in the ecological settings between the continents may be responsible for the disparity in diversification dynamics. These results reveal long-term outcomes of biological invasions and show that the importance of explosive radiations in shaping diversity extends beyond insular systems and have significant impact at continental scales.
Resumo:
The costs related to the treatment of infected total joint arthroplasties represent an ever groving burden to the society. Different patient-adapted therapeutic options like débridement and retention, 1- or 2-step exchange can be used. If a 2-step exchange is used we have to consider short (2-4 weeks) or long (>4-6 weeks) interval treatment. The Swiss DRG (Diagnose related Groups) determines the reimboursement the hopsital receives for the treatment of an infected total arthroplasty. The review assesses the cost-effectiveness of hospitalisation practices linked to surgical treatment in the two-stage exchange of a prosthetic-joint infection. The aim of this retrospectiv study is to compare the economical impact between a short (2 to 4 weeks) versus a long (6 weeks and above) interval during a two-satge procedure to determine the financial impact. Retrospectiv study of the patients with a two-stage procedure for a hip or knee prosthetic joint infection at CHUV hospital Lausanne (Switzerland) between 2012 and 2013. The review analyses the correlation between the interval length and the length of the hospital stay as well as with the costs and revenues per hospital stay. In average there is a loss of 40′000 Euro per hospitalisation for the treatment of prosthetic joint infection. Revenues never cover all the costs, even with a short interval procedure. This economical loss increases with the length of the hospital stay if a long-term intervall is choosen. The review explores potential for improvement in reimbourement practices and hospitalisation practices in the current Swiss healthcare setting. There should be alternative setups to decrease the burden of medical costs by a) increase the reimboursment for the treatment of infected total joints or by b) splitting the hospital stay with partners (rapid transfer after first operation from center hospital to level 2 hospital and retransfer for second operation to center) in order to increase revenues.
Resumo:
Different therapeutic options for prosthetic joint infections exist, but surgery remains the key. With a two-stage exchange procedure, a success rate above 90% can be expected. Currently, there is no consensus regarding the optimal duration between explantation and the reimplantation in a two-stage procedure. The aim of this study was to retrospectively compare treatment outcomes between short-interval and long-interval two-stage exchanges. Patients having a two-stage exchange of a hip or knee prosthetic joint infection at Lausanne University Hospital (Switzerland) between 1999 and 2013 were included. The satisfaction of the patient, the function of the articulation and the eradication of infection, were compared between patients having a short (2 to 4 weeks) versus a long (4 weeks and more) interval during a two-stage procedure. Patient satisfaction was defined as good if the patient did not have pain and bad if the patient had pain. Functional outcome was defined good if the patient had a prosthesis in place and could walk, medium if the prosthesis was in place but the patient could not walk, and bad if the prosthesis was no longer in place. Infection outcome was considered good if there had been no re-infection and bad if there had been a re-infection of the prosthesis 145 patients (100 hips, 45 knees) were identified with a median age of 68 years (range 19-103). The median hospital stay was 58 days (range 10-402). The median follow-up was 12.9 months (range 0.5-152). 28 % and 72 % of the patients had a short-interval and long-interval exchange of the prosthesis, respectively. Patient satisfaction, functional outcome and infection outcome for patients having a short versus a long interval are reported in the Table. The patient satisfaction was higher when a long interval was performed whereas the functional and infection outcomes were higher when a short interval was performed. According to this study a short-interval exchange appears preferable to a long interval, especially in the view of treatment effectiveness and functional outcome.
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
Context awareness is emerging on mobile devices. Context awareness can be used to improve usability of a mobile device. Context awareness is particularly important on mobile devices due the limitations they have. At first in this work, a literature review on context awareness and mobile environment is made. For aiding context awareness there exist an implementation of a Context Framework for Symbian S60 devices. It provides a possibility for exchanging the contexts inside the device between the client applications of the local Context Framework. The main contribution of this thesis is to design and implement an enhancement to the S60 Context Framework for providing possibility to exchange context over device boundaries. Using the implemented Context Exchange System, the context exchange is neither depending on the type of the context nor the type of the client. In addition, the clients and the contexts can reside on any interconnected device. The usage of the system is independent of the programming language since in addition to using only Symbian C++ function interfaces it can also be utilized using XML scripts. The Meeting Sniffer application, which uses the Context Exchange System, was also developed in this work. Using this application, it is possible to recognize a meeting situation and suggest device profile change to a user.
Resumo:
The aim of this work was to explore the possibility of the application of a non-ionic resin obtained by impregnation of Alizarin Red S (VAS) in Amberlite XAD-7 for manganese, copper and zinc separation and preconcentration in saline matrices. For these system, the metals were quantitatively retained, in the pH range 8.5-10.0, by using 0.50 g of solid phase, stirring time of five minutes and a total mass up to 200 mug of each cation. The sorbed elements were subsequently eluted and a fifty-fold, ten-fold and ten-fold preconcentration factor for to Zn, Cu and Mn were obtained, respectively.
Resumo:
In this work the metal distribution and exchange constants between metal species and aquatic humic fractions with different molecular sizes were studied. The aquatic humic substances (AHS) were extracted by XAD-8 resin from water sample collected from Itapitanguí river, São Paulo State, Brazil. The AHS were fractionated in six fractions with different molecular sizes (>100 - <5 kDa) and characterized by several techniques. Molar ratios H/C suggested higher aromaticity for fractions F1 and F6 whereas molar ratios C/N didn´t show any differences regarding the humification degree between the fractions. The UV-Vis absorbance a254/a436 ratio showed higher results for F4 and F5, probably by less condensed features. FTIR studies showed high similarity in the functional groups in the fractions. The highest percentage of traces of Co, Al, Fe, Mn, Cu, Zn and Ni (determined by ICP-AES) was preferably complexed by fractions F3 and F4 with a greater amount of dissolved organic carbon (DOC). In addition, the exchange constants, determined by ultrafiltration method, showed complexes AHS-Fe and AHS-Al with higher stability than complexes AHS-Co in all fractions.
Resumo:
This paper re-examines the null of stationary of real exchange rate for a panel of seventeen OECD developed countries during the post-Bretton Woods era. Our analysis simultaneously considers both the presence of cross-section dependence and multiple structural breaks that have not received much attention in previous panel methods of long-run PPP. Empirical results indicate that there is little evidence in favor of PPP hypothesis when the analysis does not account for structural breaks. This conclusion is reversed when structural breaks are considered in computation of the panel statistics. We also compute point estimates of half-life separately for idiosyncratic and common factor components and find that it is always below one year.
Resumo:
The Catalan Research Portal (Portal de la Recerca de Catalunya or PRC) is an initiative carried out by the Consortium for University Services in Catalonia (CSUC) in coordination with nearly all universities in Catalonia. The Portal will provide an online CERIF-compliant collection of all research outputs produced by Catalan HEIs together with an appropriate contextual information describing the specific environment where the output was generated (such as researchers, research group, research project, etc). The initial emphasis of the Catalan Research Portal approach to research outputs will be made on publications, but other outputs such as patents and eventually research data will eventually be addressed as well. These guidelines provide information for PRC data providers to expose and exchange their research information metadata in CERIFXML compatible structure, thus allowing them not just to exchange validated CERIF XML data with the PRC platform, but to improve their general interoperability by being able to deliver CERIFcompatible outputs.
Resumo:
Several models for the estimation of thermodynamic properties of layered double hydroxides (LDHs) are presented. The predicted thermodynamic quantities calculated by the proposed models agree with experimental thermodynamic data. A thermodynamic study of the anion exchange process on LDHs is also made using the described models. Tables for the prediction of monovalent anion exchange selectivities on LDHs are provided. Reasonable agreement is found between the predicted and the experimental monovalent anion exchange selectivities.
Resumo:
The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.
Resumo:
Plant extracts are usually complex mixtures which contain several molecules of different sizes with varied functional groups. Such extracts are a challenge to the chemist of natural products. Ion exchange chromatography in non-aqueous medium, used for separation of basic or acidic fractions from plant extracts, is an important unit operation in preparative scale separations. Anionic macroporous resin in non-aqueous medium was used with success in this study for separation of the acid fraction of Copaifera multijuga (Copaiba oil), rich in labdanic diterpenes and for the methanolic extract of Croton cajucara (acetyl aleuritoric acid).