922 resultados para Study of timing by stop watch


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Topography is often thought as exclusively linked to mountain ranges formed by plates collision. It is now, however, known that apart from compression, uplift and denudation of rocks may be triggered by rifting, like it happens at elevated passive margins, and away from plate boundaries by both intra-plate stress causing reactivation of older structures, and by epeirogenic movements driven by mantle dynamics and initiating long-wavelength uplift. In the Cenozoic, central west Britain and other parts of the North Atlantic margins experienced multiple episodes of rock uplift and denudation that have been variable both at spatial and temporal scales. The origin of topography in central west Britain is enigmatic, and because of its location, it may be related to any of the processes mentioned above. In this study, three low temperature thermochronometers, the apatite fission track (AFT) and apatite and zircon (U-Th-Sm)/He (AHe and ZHe, respectively) methods were used to establish the rock cooling history from 200◦C to 30◦C. The samples were collected from the intrusive rocks in the high elevation, high relief regions of the Lake District (NW England), southern Scotland and northern Wales. AFT ages from the region are youngest (55–70 Ma) in the Lake District and increase northwards into southern Scotland and southwards in north Wales (>200 Ma). AHe and ZHe ages show no systematic pattern; the former range from 50 to 80 Ma and the latter tend to record the post-emplacement cooling of the intrusions (200–400 Ma). The complex, multi-thermochronometric inverse modelling suggests a ubiquitous, rapid Late Cretaceous/early Palaeogene cooling event that is particularly marked in Lake District and Criffell. The timing and rate of cooling in southern Scotland and in northern Wales is poorly resolved as the amount of cooling was less than 60◦C. The Lake District plutons were at >110◦C prior to the early Palaeogene; cooling due to a combined effect of high heat flow, from the heat producing granite batholith, and the blanketing effect of the overlying low conductivity Late Mesozoic limestones and mudstones. Modelling of the heat transfer suggests that this combination produced an elevated geothermal gradient within the sedimentary rocks (50–70◦C/km) that was about two times higher than at the present day. Inverse modelling of the AFT and AHe data taking the crustal structure into consideration suggests that denudation was the highest, 2.0–2.5 km, in the coastal areas of the Lake District and southern Scotland, gradually decreasing to less than 1 km in the northern Southern Uplands and northern Wales. Both the rift-related uplift and the intra-plate compression poorly correlate with the timing, location and spatial distribution of the early Palaeogene denudation. The pattern of early Palaeogene denudation correlates with the thickness of magmatic underplating, if the changes of mean topography, Late Cretaceous water depth and eroded rock density are taken into consideration. However, the uplift due to underplating alone cannot fully justify the total early Palaeogene denudation. The amount that is not ex- plained by underplating is, however, roughly spatially constant across the study area and can be referred to the transient thermal uplift induced by the mantle plume arrival. No other mechanisms are required to explain the observed pattern of denudation. The onset of denudation across the region is not uniform. Denudation started at 70–75 Ma in the central part of the Lake District whereas the coastal areas the rapid erosion appears to have initiated later (65–60 Ma). This is ~10 Ma earlier than the first vol- canic manifestation of the proto-Iceland plume and favours the hypothesis of the short period of plume incubation below the lithosphere before the volcanism. In most of the localities, the rocks had cooled to temperatures lower than 30◦C by the end of the Palaeogene, suggesting that the total Neogene denudation was, at a maximum, several hundreds of metres. Rapid cooling in the last 3 million years is resolved in some places in southern Scotland, where it could be explained by glacial erosion and post-glacial isostatic uplift.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fish is a valuable nutritional source witch use of it in daily meal has a beneficial role on nutritional needs supply and also causes mental and physical health especially in people who have protein and food deficiencies. Unfortunately, per capita consumption of sea foods in Iran is 5.5Kg witch is very lower than world standards. So, study on fish ice cream formulation, by use of fish protein concentrate (FPC) instead of milk protein, had done to make variation in sea foods products and also increase per capita consumption of these kinds of foods. FPC has very high protein concentration and a lot of necessary Also it's protein is very digestible amino acids like lysine and methionine with highly biological value and it's PER in compare with casein PER is high. At first fish protein concentrate type A produced from silver carp in three steps by the extraction with isopropyl alcohol solvent and heat. Microbiological and physicochemical specifications of produced FPC by rules of FDA and FAO were accepted. Finally according to panel test results, substitution of 30 percent of milk with FPC is acceptable. Also microbiological and physicochemical specifications of product were tested and results in compare with national standards of Iran were accepted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is no secret that computer services came to revolutionize the world. More than a service, have since become an indispensable tool for humanity, because they simplify and make life easier in many of his orders, through its various support options. These advances are added Internet services, so that by the mid 1980's assessed the need for such a research tool in order to apply it in various fields of human knowledge.This research, based on the use and quality of documentary information from the Internet, with application to the students of the Universidad Nacional, Costa Rica, if the Library Board Laboratory Joaquin Garcia Monge, develops in the form of theses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper studies the influence of rail weld dip on wheel-rail contact dynamics, with particular reference to freight trains where it is important to increase the operating speed and also the load transported. This has produced a very precise model, albeit simple and cost-effective, which has enabled train-track dynamic interactions over rail welds to be studied to make it possible to quantify the influence on dynamic forces and displacements of the welding geometry; of the position of the weld relative to the sleeper; of the vehicle's speed; and of the axle load and wheelset unsprung mass. It is a vertical model on the spatial domain and is drawn up in a simple fashion from vertical track receptances. For the type of track and vehicle used, the results obtained enable the quantification of increases in wheel-rail contact forces due to the new speed and load conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The changes in time and location of surface temperature from a water body has an important effect on climate activities, marine biology, sea currents, salinity and other characteristics of the seas and lakes water. Traditional measurement of temperature is costly and time consumer due to its dispersion and instability. In recent years the use of satellite technology and remote sensing sciences for data acquiring and parameter and lysis of climatology and oceanography is well developed. In this research we used the NOAA’s Satellite images from its AVHRR system to compare the field surface temperature data with the satellite images information. Ten satellite images were used in this project. These images were calibrated with the field data at the exact time of satellite pass above the area. The result was a significant relation between surface temperatures from satellite data with the field work. As the relative error less than %40 between these two data is acceptable, therefore in our observation the maximum error is %21.2 that can be considered it as acceptable. In all stations the result of satellite measurements is usually less than field data that cores ponds with the global result too. As this sea has a vast latitude, therefore the different in the temperature is natural. But we know this factor is not the only cause for surface currents. The information of all satellites were images extracted by ERDAS software, and the “Surfer” software is used to plot the isotherm lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

My thesis aim is to find out what factors that can explain the entrepreneurial failure in my own entrepreneurial venture to sell Finnish xylitol product to Poland. In addition I seek to answer to the question of why Finnish xylitol products are not sold in Poland. This area has not been studied prior to my thesis. The study method is case study. Data collection is based on auto-ethnographic method where field notes and documents generated from my business venture were used. I discovered that Polish consumers are not exposed to consumer education of xylitol health benefits. The underlying potential in xylitol products expansion from Finland to foreign countries is still mostly unleveraged. My business venture failed because I was not able to convince Finnish confectionery companies Fazer and Cloetta to give enough support for my project. Polish dentists were also opposed having a competitor from Finland to Wrighley company which dominates the Polish confectionery markets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To investigate opposition to standardised tobacco packaging in the UK. To increase understanding of how transnational corporations are adapting to changes in their access to policymakers precipitated by Article 5.3 of the Framework Convention on Tobacco Control (FCTC). Design: Case study web-based documentary analysis, using NVivo V.10. Examination of relationships between opponents of standardised packaging and transnational tobacco companies (TTCs) and of the volume, nature, transparency and timing of their activities. Setting: UK standardised packaging policy debate 2011-2013. Participants: Organisations selected on basis of opposition to, or facilitation thereof, standardised tobacco packaging in the UK; 422 associated documents. Results: Excluding tobacco manufacturing and packaging companies (n=12), 109 organisations were involved in opposing standardised packaging, 82 (75%) of which had a financial relationship with 1 or more TTC. These 82 organisations (43 actively opposing the measure, 39 facilitating opposition) were responsible for 60% of the 404 activities identified, including the majority of public communications and research production. TTCs were directly responsible for 28% of total activities, predominantly direct lobbying, but also financially underwrote third party research, communication, mass recruitment and lobbying. Active organisations rarely reported any financial relationship with TTCs when undertaking opposition activities. Conclusions: The multifaceted opposition to standardised packaging was primarily undertaken by third parties with financial relationships with major tobacco manufacturers. Low levels of transparency regarding these links created a misleading impression of diverse and widespread opposition. Countries should strengthen implementation of Article 5.3 of the FCTC by systematically requiring conflict of interest declarations from all organisations participating in political or media debates on tobacco control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inflammatory bowel disease (IBD) is a chronic inflammation which affects the gastrointestinal tract (GIT). One of the best ways to study the immunological mechanisms involved during the disease is the T cell transfer model of colitis. In this model, immunodeficient mice (RAG-/-recipients) are reconstituted with naive CD4+ T cells from healthy wild type hosts. This model allows examination of the earliest immunological events leading to disease and chronic inflammation, when the gut inflammation perpetuates but does not depend on a defined antigen. To study the potential role of antigen presenting cells (APCs) in the disease process, it is helpful to have an antigen-driven disease model, in which a defined commensal-derived antigen leads to colitis. An antigen driven-colitis model has hence been developed. In this model OT-II CD4+ T cells, that can recognize only specific epitopes in the OVA protein, are transferred into RAG-/- hosts challenged with CFP-OVA-expressing E. coli. This model allows the examination of interactions between APCs and T cells in the lamina propria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

TiSiC-Cr coatings, with Cr and Si as additional elements, were deposited on Si, C 45 and 316 L steel substrates via cathodic arc evaporation. Two series of coatings with thicknesses in the range of 3.6–3.9 μm were produced, using either CH4 or C2H2 as carbon containing gas. For each series, different coatings were prepared by varying the carbon rich gas flow rate between 90 and 130 sccm, while maintaining constant cathode currents (110 and 100 A at TiSi and Cr cathodes, respectively), substrate bias (–200 V) and substrate temperature (∼320 °C). The coatings were analyzed for their mechanical characteristics (hardness, adhesion) and tribological performance (friction, wear), along with their elemental and phase composition, chemical bonds, crystalline structure and cross-sectional morphology. The coatings were found to be formed with nano-scale composite structures consisting of carbide crystallites (grain size of 3.1–8.2 nm) and amorphous hydrogenated carbon. The experimental results showed significant differences between the two coating series, where the films formed from C2H2 exhibited markedly superior characteristics in terms of microstructure, morphology, hardness, friction behaviour and wear resistance. For the coatings prepared using CH4, the measured values of crystallite size, hardness, friction coefficient and wear rate were in the ranges of 7.2–8.2 nm, 26–30 GPa, 0.3–0.4 and 2.1–4.8 × 10−6 mm3 N−1 m−1, respectively, while for the coatings grown in C2H2, the values of these characteristics were found to be in the ranges of 3.1–3.7 nm, 41–45 GPa, 0.1–0.2 and 1.4–3.0 × 10−6 mm3 N−1 m−1, respectively. Among the investigated coatings, the one produced using C2H2 at the highest flow rate (130 sccm) exhibited the highest hardness (45.1 GPa), the lowest friction coefficient (0.10) and the best wear resistance (wear rate of 1.4 × 10−6 mm3 N−1 m−1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The background of this study is to assess the accuracy of lung ultrasound (LUS) to diagnose interstitial lung disease (ILD) in Sjögren’s syndrome (Sjs), in patients who have any alterations in pulmonary function tests (PFT) or respiratory symptoms. LUS was correlated with chest tomography (hrCT), considering it as the imaging gold standard technique to diagnose ILD. This is a pilot, multicenter, cross-sectional, and consecutive-case study. The inclusion criteria are ≥18 years old, Signs and symptoms: according to ACEG 2002 criteria, respiratory symptoms (dyspnea, cough), or any alterations in PFR. LUS was done following the International Consensus Conference on Lung Ultrasound protocol for interstitial syndrome (B pattern). Of the 50 patients in follow-up, 13 (26%) met the inclusion criteria. All were women with age 63.62 years (range 39–88). 78.6% of the cases had primary Sjs (SLE, RA, n = 2). The intra-rater reliability k is 1, according to Gwet’s Ac1 and GI index (probability to concordance—e(K)—, by Cohen, of 0.52). LUS has a sensitivity of 1 (95% CI 0.398–1.0), specificity of 0.89 (95% CI 0.518–0.997), and a positive probability reason of 9.00 (95% CI 7.1–11.3) to detect ILD. The correlation of Pearson is r = 0.84 (p < 0.001). To check the accuracy of LUS to diagnose ILD, a completely bilateral criterion of yes/no for interstitial pattern was chosen, AUC reaches significance, 0.94 (0.07) (95% CI 0.81–1.0, p = 0.014). LUS reaches an excellent correlation to hrCT in Sjs affected with ILD, and might be a useful technique in daily clinical practice for the assessment of pulmonary disease in the sicca syndrome. © 2016 SIMI

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interface formed between Cu3BiS3 thin films and the buffer layer is a potentially limiting factor to the performance of solar cells based on Al/Cu3BiS3/buffer heterojunctions. The buffer layers of ZnS and In2S3 were grown by coevaporation, and tested as an alternative to the traditional CdS deposited by chemical bath deposition. From the Kelvin probe force microscopy measurements, we found the values of the work function of ZnS, In2S3, and CdS, layers deposited into Cu3BiS3. Additionally, different electronic activity was found for different grain boundaries (GBs), from studies under illumination, we also found the net doping concentration and the density of charged GB states for Cu3BiS3 and Cu3BiS3/CdS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a study related with measuring of radio frequency emissions. The purpose is to determine the level of interference generated by wireless power transfer equipment in a specific frequency range, and to compare those levels to the existing standards. The technology of wireless power transfer, especially for electric vehicles batteries charging, is rapidly developing in the recent years. An increasing use of this technology in industrial and consumer electronic products has raised concerns about the possible unfavorable health-effects onto the human being. Another concern is raised from the high intensity fields produced by wireless power transfer systems which will generate highly undesired influence on other electrical and electronic equipment. As a protection against the potential health effects, the governments imposed limits on the occupational and general public exposure to the radio frequencies. These limitations are set out in national and international safety guidelines, standards and regulations. The measurement and evaluation of the human exposure to electromagnetic fields are essential to guarantee occupational and general public safety.