981 resultados para Stabilization plano
Resumo:
OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.
Resumo:
The objective of this study was to describe the use of a titanium 1.5 mm locking plate in the stabilization of atlantoaxial pathology in three toy breed dogs. Two dogs with atlantoaxial subluxation and another dog with an axial fracture, confirmed by diagnostic imaging, were stabilized via a ventral approach with a 1.5 mm titanium 5-hole locking butterfly-plate. Surgical reduction and stabilization were assessed by computed tomography and radiography after surgery. Follow-up evaluation for resolution of neurological signs and possible complications was performed in all three dogs. For long-term assessment, a telephone follow-up was performed. A considerable improvement of neurological signs occurred within two to four weeks after surgery. An excellent clinical outcome was identified in all three patients. Adequate stabilization and resolution of neurological signs in all three dogs was achieved. The stabilization of atlantoaxial surgical conditions in toy breeds with the 1.5 mm titanium 5-hole butterfly locking plate appears to be an effective means of surgical treatment.
Resumo:
STUDY DESIGN:: retrospective analysis of prospectively collected clinical data. OBJECTIVE:: To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA:: The Dynesys® system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome following treatment for degenerative spondylolisthesis at the L4/5 level. METHODS:: 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range 5.0-11.2▒y) they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS:: At final follow-up back pain improved in 89% and leg pain improved in 86% of patients compared to preoperative status. 83% of patients reported global subjective improvement. 92% would undergo the surgery again. 8 patients (21%) required further surgery due to symptomatic adjacent segment disease (6 cases), late onset infection (1 case), and screw breakage (1 case). In 9 cases radiological progression of spondylolisthesis at the operated segment was found. 74% of operated segments showed limited flexion-extension range of less than 4°. Adjacent segment pathology, though without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases asymptomatic screw loosening was observed. CONCLUSION:: Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiological and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.
Resumo:
Surgery involving arthroscopic reconstruction of the injured ligament is the gold standard treatment for torn anterior cruciate ligament (ACL). Recent studies support the hypothesis of biological self-healing of ruptured ACL. The aim of the study is to evaluate, in an animal model, the efficacy of a new technique, dynamic intraligamentary stabilization that utilizes biological self-healing for repair of acute ACL ruptures.
Resumo:
The maintenance of colour polymorphisms within populations has been a long-standing interest in evolutionary ecology. African cichlid fish contain some of the most striking known cases of this phenomenon. Intrasexual selection can be negative frequency dependent when males bias aggression towards phenotypically similar rivals, stabilizing male colour polymorphisms. We propose that where females are territorial and competitive, aggression biases in females may also promote coexistence of female morphs. We studied a polymorphic population of the cichlid fish Neochromis omnicaeruleus from Lake Victoria, in which three distinct female colour morphs coexist: one plain brown and two blotched morphs. Using simulated intruder choice tests in the laboratory, we show that wild-caught females of each morph bias aggression towards females of their own morph, suggesting that females of all three morphs may have an advantage when their morph is locally the least abundant. This mechanism may contribute to the establishment and stabilization of colour polymorphisms. Next, by crossing the morphs, we generated sisters belonging to different colour morphs. We find no sign of aggression bias in these sisters, making pleiotropy unlikely to explain the association between colour and aggression bias in wild fish, which is maintained in the face of gene flow. We conclude that female-female aggression may be one important force for stabilizing colour polymorphism in cichlid fish.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate, in relation to intraoperative estimated blood loss (EBL), the effectiveness of preoperative transcatheter arterial embolization of hypervascular osseous metastatic lesions before orthopedic resection and stabilization. MATERIALS AND METHODS: Between June 1987 and November 2007, 22 patients underwent transcatheter arterial embolization of tumors of the long bone, hip, or vertebrae before resection and stabilization. Osseous metastatic lesions from renal cell carcinoma, malignant melanoma, leiomyosarcoma, and prostate cancer were embolized. All patients were treated with a coaxial catheter technique with polyvinyl alcohol (PVA) particles alone or a combination of PVA particles and coils. After embolization, each tumor was angiographically graded according to devascularization (grades 1-3) based on tumor blush after contrast injection into the main tumor-feeding arteries. RESULTS: In patients with complete devascularization (grade 1), mean EBL was calculated to be 1,119 mL, whereas in patients with partial embolization (grades 2 and 3) EBL was 1,788 mL and 2,500 mL. With respect to intraoperative EBL, no significant difference between devascularization grades was found (p > 0.05). Moderate correlation (r = 0.51, p = 0.019) was observed between intraoperative EBL and tumor size before embolization. Only low correlation (r = 0.44, p = 0.046) was found between intraoperative EBL and operating time. Major complications included transient palsy of the sciatic nerve and gluteal abscess in one patient. CONCLUSION: The results of this study support the concept that there is no statistically significant difference among amounts of intraoperative EBL with varying degrees of embolization.