Stabilization of Juxta-Physeal Distal Tibial and Fibular Fractures in a Juvenile Tiger Using a Hybrid Circular-Linear External Fixator


Autoria(s): Coomer, Alastair R.; Lewis, Daniel D.; Wiedner, Ellen; Isaza, Ramiro; Winter, Matthew D.; Aloisio, Fabio; Pool, Roy
Data(s)

2012

Resumo

OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.

Formato

application/pdf

Identificador

http://boris.unibe.ch/12002/1/vsu897.pdf

Coomer, Alastair R.; Lewis, Daniel D.; Wiedner, Ellen; Isaza, Ramiro; Winter, Matthew D.; Aloisio, Fabio; Pool, Roy (2012). Stabilization of Juxta-Physeal Distal Tibial and Fibular Fractures in a Juvenile Tiger Using a Hybrid Circular-Linear External Fixator. Veterinary surgery, 41(2), pp. 248-253. Oxford: Wiley-Blackwell 10.1111/j.1532-950X.2011.00897.x <http://dx.doi.org/10.1111/j.1532-950X.2011.00897.x>

doi:10.7892/boris.12002

info:doi:10.1111/j.1532-950X.2011.00897.x

urn:issn:0161-3499

Idioma(s)

eng

Publicador

Wiley-Blackwell

Relação

http://boris.unibe.ch/12002/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Coomer, Alastair R.; Lewis, Daniel D.; Wiedner, Ellen; Isaza, Ramiro; Winter, Matthew D.; Aloisio, Fabio; Pool, Roy (2012). Stabilization of Juxta-Physeal Distal Tibial and Fibular Fractures in a Juvenile Tiger Using a Hybrid Circular-Linear External Fixator. Veterinary surgery, 41(2), pp. 248-253. Oxford: Wiley-Blackwell 10.1111/j.1532-950X.2011.00897.x <http://dx.doi.org/10.1111/j.1532-950X.2011.00897.x>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed