963 resultados para SIGNAL AMPLIFICATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rousettus aegyptiacus Geoffroy 1810 is a member of the only genus of Megachiropteran bats to use vocal echolocation, but the structure of its brief, click-like signal is poorly described. Although thought to have a simple echolocation system compared to that of Microchiroptera, R. aegyptiacus is capable of good obstacle avoidance using its impulse sonar. The energy content of the signal was at least an order of magnitude smaller than in Microchiropteran bats and dolphins (approximately 4 X 10(-8) J m(-2)). Measurement of the duration, amplitude and peak frequency demonstrate that the signals of this animal are broadly similar in structure and duration to those of dolphins. Gabor functions were used to model signals and to estimate signal parameters, and the quality of the Gabor function fit to the early part of the signal demonstrates that the echolocation signals of R. aegyptiacus match the minimum spectral spread for their duration and amplitude and are thus well matched to its best hearing sensitivity. However, the low energy content of the signals and short duration should make returning echoes difficult to detect. The performance of R. aegyptincus in obstacle avoidance experiments using echolocation therefore remains something of a conundrum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors consider a point percolation lattice representation of a large-scale wireless relay sensor network (WRSN) deployed in a cluttered environment. Each relay sensor corresponds to a grid point in the random lattice and the signal sent by the source is modelled as an ensemble of photons that spread in the space, which may 'hit' other sensors and are 'scattered' around. At each hit, the relay node forwards the received signal to its nearest neighbour through direction-selective relaying. The authors first derive the distribution that a relay path reaches a prescribed location after undergoing certain number of hops. Subsequently, a closed-form expression of the average received signal strength (RSS) at the destination can be computed as the summation of all signal echoes' energy. Finally, the effect of the anomalous diffusion exponent ß on the mean RSS in a WRSN is studied, for which it is found that the RSS scaling exponent e is given by (3ß-1)/ß. The results would provide useful insight into the design and deployment of large-scale WRSNs in future. © 2011 The Institution of Engineering and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a ? coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.