931 resultados para Receiver


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A liquid phase blocking ELISA (LPB-ELISA) was adapted for the detection and quantification of antibodies to Newcastle disease virus. Sera from vaccinated and unvaccinated commercial flocks of ostriches (Struthio camelus) and rheas (Rhea americana) were tested. The purified and nonpurified virus used as the antigen and the capture and detector antibodies were prepared and standardized for this purpose. The hemagglutination-inhibition (HI) test was regarded as the reference method, the cutoff point for the LPB-ELISA was determined by a two-graph receiver operating characteristic analysis. The LPB-ELISA titers regressed significantly (P < 0.0001) on the HI titers with a high correlation coefficient (r = 0.875). The two tests showed good agreement ( = 0.82; P < 0.0001), relative sensitivity (90.91%) and specificity (91.18%), and accuracy (91.02%), suggesting that they are interchangeable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10x occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0-6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and inter-examiner repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was strongly associated with TD. Although the correlation between the ICDAS and BW was lower, it is still valuable in the clinical decision-making process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioassays were carried out to identify and characterize the allelopathic potential effects of forage legumes leucena (Leucaena leucocephala), mineirão (Stylosanthes guianensis cv. Mineirão) and calopogônio (Calopogonium mucunoides) on germination and radicle elongation of the pasture weeds desmódio (Desmodium adscendens), guanxuma (Sida rhombifolia) and assa-peixe (Vernonia polyanthes). Aqueous seeds and shoot extracts were prepared in a concentration of 10% (w/v). The pH and osmotic potential were measured in each extract. The effects of the osmotic potential on the results were calculated considering the regression equations adjusted to the variations of osmotic potential in each parameter and the osmotic potential of the extracts. The results showed that the pH did not constitute in a source of variation of the results. The donor species indicated allelopathic potential that varied in function of donor and receiver species and part of the donor plant. The aqueous shoot extract of mineirão and calopogônio showed inhibition potential higher than the extract from seeds, while for leucena the effects more evident were obtained with the extract from seeds. Comparatively, the radicle elongation was a more sensitive indicator than germination to the effects of the extracts.The receiver species assa-peixe was the less sensitive to the effects of the extract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design of a Gilbert Cell Mixer and a low noise amplifier (LNA), using GaAs PHEMT technology is presented. The compatibility is shown for co-integration of both block on the same chip, to form a high performance 1.9 GHz receiver front-end. The designed LNA shows 9.23 dB gain and 2.01 dB noise figure (NF). The mixer is designed to operate at RF=1.9 GHz, LO=2.0 GHz and IF=100 MHz with a gain of 14.3 dB and single sideband noise figure (SSB NF) of 9.6 dB. The mixer presents a bandwith of 8 GHz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an ultrasonic method to measure small concentrations of water in lubricating oil. It uses an ultrasonic measurement cell composed by a piezoceramic emitter (5 and 10 MHz), and a large aperture PVDF receiver that eliminates diffraction effects. The propagation velocity, attenuation coefficient and density of several samples of water-in-oil emulsion were measured. The concentrations of water of the samples were in the range of 0 to 5% in volume, and the results showed that these low concentrations can be discriminated within a resolution of 0.2% in the studied range, using the measurement of the propagation velocity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single frequency GPS receivers have been many used in GPS surveys. Among the several applications, one can mention those that are to obtain the receiver's antenna coordinates in real time. One of the main error sources to these applications is the ionosphere systematic error. In the FCT/UNESP a regional ionosphere model (Mod_Ion) was developed. It has been implemented to execute after collecting of GPS data. At real time application two improvements in the Mod_Ion were introduced, consisting of an alteration of the function of modeling and implementation of the Kalman Filter. The results of the experiments showed that the modifications were the most effective in the ionosphere systematic effect's corrections, providing a improvement in the accuracy of point positioning, of 90,75%, in period of the highest ionosphere activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the accuracy of the variables related to the fixed-height stair-climbing test (SCT) using maximal oxygen uptake (V̇O 2 max) as the gold standard. Methods: The SCT was performed on a staircase consisting of 6 flights (72 steps; 12.16 m total height), with verbal encouragement, in 51 patients. Stair-climbing time was measured, the variables 'work' and 'power' also being calculated. The V̇O2 max was measured using ergospirometry according to the Balke protocol. We calculated the Pearson linear correlation (r), as well as the values of p, between the SCT variables and V̇O2 max. To determine accuracy, the V̇O 2 max cut-off point was set at 25 mL/kg/min, and individuals were classified as normal or altered. The cut-off points for the SCT variables were determined using the receiver operating characteristic curve. The Kappa statistic (k) was used in order to assess concordance. Results: The following values were obtained for the variable 'time': cut-off point = 40 s; mean = 41 ± 15.5 s; r = -0.707; p < 0.005; specificity = 89%; sensibility = 83%; accuracy = 86%; and k = 0.724. For 'power', the values obtained were as follows: cut-off point = 200 w; mean = 222.3 ± 95.2 w; r = 0.515; p < 0.005; specificity = 67%; sensibility= 75%; accuracy = 71%; and k = 0.414. Since the correlation between the variable 'work' and V̇O2 max was not significant, that variable was discarded. Conclusion: Of the SCT variables tested, using V̇O2 max as the gold standard, the variable 'time' was the most accurate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work analyses a real time orbit estimator using the raw navigation solution provided by GPS receivers. The estimation algorithm considers a Kalman filter with a rather simple orbit dynamic model and random walk modeling of the receiver clock bias and drift. Using the Topex/Poseidon satellite as test bed, characteristics of model truncation, sampling rates and degradation of the GPS receiver (Selective Availability) were analysed. Copyright © 2007 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, with the implantation of GNSS (Global Navigation Satellite System) reference station networks, several positioning techniques have been developed and/or improved. Using such kind of network data it is possible to model the GNSS distance dependent errors and to compute correction terms for the network region. Several methods have been developed to formulate the corrections terms from network stations data. A method that has been received a great attention is the Virtual Reference Station (VRS). The idea is that the VRS data resemble as much as possible a real receiver data placed in the same local. Therefore, the user has the possibility of using the VRS as if it were a real reference station in your proximities, and to accomplish the relative positioning with a single frequency receiver. In this paper it is described a different methodology applied to implement the VRS concept, using atmospheric models developed by Brazilian researchers. Besides, experiments for evaluating the quality of generated VRS are presented, showing the efficiency of the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integer carrier phase ambiguity resolution is the key to rapid and high-precision global navigation satellite system (GNSS) positioning and navigation. As important as the integer ambiguity estimation, it is the validation of the solution, because, even when one uses an optimal, or close to optimal, integer ambiguity estimator, unacceptable integer solution can still be obtained. This can happen, for example, when the data are degraded by multipath effects, which affect the real-valued float ambiguity solution, conducting to an incorrect integer (fixed) ambiguity solution. Thus, it is important to use a statistic test that has a correct theoretical and probabilistic base, which has became possible by using the Ratio Test Integer Aperture (RTIA) estimator. The properties and underlying concept of this statistic test are shortly described. An experiment was performed using data with and without multipath. Reflector objects were placed surrounding the receiver antenna aiming to cause multipath. A method based on multiresolution analysis by wavelet transform is used to reduce the multipath of the GPS double difference (DDs) observations. So, the objective of this paper is to compare the ambiguity resolution and validation using data from these two situations: data with multipath and with multipath reduced by wavelets. Additionally, the accuracy of the estimated coordinates is also assessed by comparing with the ground truth coordinates, which were estimated using data without multipath effects. The success and fail probabilities of the RTIA were, in general, coherent and showed the efficiency and the reliability of this statistic test. After multipath mitigation, ambiguity resolution becomes more reliable and the coordinates more precise. © Springer-Verlag Berlin Heidelberg 2007.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of the ionosphere on the signals of Global Navigation Satellite Systems (GNSS), such as the Global Positionig System (GPS) and the proposed European Galileo, is dependent on the ionospheric electron density, given by its Total Electron Content (TEC). Ionospheric time-varying density irregularities may cause scintillations, which are fluctuations in phase and amplitude of the signals. Scintillations occur more often at equatorial and high latitudes. They can degrade navigation and positioning accuracy and may cause loss of signal tracking, disrupting safety-critical applications, such as marine navigation and civil aviation. This paper addresses the results of initial research carried out on two fronts that are relevant to GNSS users if they are to counter ionospheric scintillations, i.e. forecasting and mitigating their effects. On the forecasting front, the dynamics of scintillation occurrence were analysed during the severe ionospheric storm that took place on the evening of 30 October 2003, using data from a network of GPS Ionospheric Scintillation and TEC Monitor (GISTM) receivers set up in Northern Europe. Previous results [1] indicated that GPS scintillations in that region can originate from ionospheric plasma structures from the American sector. In this paper we describe experiments that enabled confirmation of those findings. On the mitigation front we used the variance of the output error of the GPS receiver DLL (Delay Locked Loop) to modify the least squares stochastic model applied by an ordinary receiver to compute position. This error was modelled according to [2], as a function of the S4 amplitude scintillation index measured by the GISTM receivers. An improvement of up to 21% in relative positioning accuracy was achieved with this technnique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to implant a geodesic pillar in the campus of Botucatu (Rubião Júnior) of the São Paulo State University (UNESP), using active stations of the Brazilian Net of Continuous Monitoring (RBMC) as reference, aiming at inclusion in the Brazilian Geodesic System (BGS). In the planning of the trace, some aspects of the pillar optimization were considered: the field evaluation, the equipment Receiver GPS Topcon Hiper GGD and the net RBMC were used to trace the height, and the Topcon Tools 6.04 version software was use for the data processing, the ambiguity solution, as well as the treatment of injunctions during the column adjustment. The obtained results allowed the implantation of a more accurate pillar then 1ppm compatible to the RBMC net, meeting the specification of IBGE.