970 resultados para Ground control point
Resumo:
OBJECTIVE - The purpose of this study was to determine whether beneficial effects on glycemic control of an initial laboratory-supervised resistance training program could be sustained through a community center-based maintenance program. RESEARCH DESIGN AND METHODS - We studied 57 overweight (BMI >= 27 kg/m(2)) sedentary men and women aged 40-80 years with established (> 6 months) type 2 diabetes. initially, all participants attended a twice-weekly 2-month supervised resistance training program conducted in the exercise laboratory. Thereafter, participants undertook a resistance training maintenance program (2 times/week) for 12 months and were randomly assigned to carry this out either in a community fitness and recreation center (center) or in their domestic environment (home). Glycemic control (HbA(1c) [A1C]) was assessed at 0, 2, and 14 months. RESULTS - Pooling data from the two groups for the 2-month supervised resistance training program showed that compared with baseline, mean A1C fell by -0.4% [95% CI -0.6 to -0.2]. Within-group comparisons showed that A I C remained lower than baseline values at 14 months in the center group (- 0.4% [-0.7 to -0.03]) but not in the home group (-0.1% [-0.4 to 0.3]). However, no between-group differences were observed at each time point. Changes in AIC during the maintenance period were positively associated with exercise adherence in the center group only. CONCLUSIONS - Center-based but not home-based resistance training was associated with the maintenance of modestly improved glycemic control from baseline, which was proportional to program adherence. Our findings emphasize the need to develop and test behavioral methods to promote healthy lifestyles including increased physical activity in adults with type 2 diabetes.
Resumo:
A new control algorithm using parallel braking resistor (BR) and serial fault current limiter (FCL) for power system transient stability enhancement is presented in this paper. The proposed control algorithm can prevent transient instability during first swing by immediately taking away the transient energy gained in faulted period. It can also reduce generator oscillation time and efficiently make system back to the post-fault equilibrium. The algorithm is based on a new system energy function based method to choose optimal switching point. The parallel BR and serial FCL resistor can be switched at the calculated optimal point to get the best control result. This method allows optimum dissipation of the transient energy caused by disturbance so to make system back to equilibrium in minimum time. Case studies are given to verify the efficiency and effectiveness of this new control algorithm.
Resumo:
In developing neural network techniques for real world applications it is still very rare to see estimates of confidence placed on the neural network predictions. This is a major deficiency, especially in safety-critical systems. In this paper we explore three distinct methods of producing point-wise confidence intervals using neural networks. We compare and contrast Bayesian, Gaussian Process and Predictive error bars evaluated on real data. The problem domain is concerned with the calibration of a real automotive engine management system for both air-fuel ratio determination and on-line ignition timing. This problem requires real-time control and is a good candidate for exploring the use of confidence predictions due to its safety-critical nature.
Resumo:
Compared to packings trays are more cost effective column internals because they create a large interfacial area for mass transfer by the interaction of the vapour on the liquid. The tray supports a mass of froth or spray which on most trays (including the most widely used sieve trays) is not in any way controlled. The two important results of the gas/liquid interaction are the tray efficiency and the tray throughput or capacity. After many years of practical experience, both may be predicted by empirical correlations, despite the lack of understanding. It is known that the tray efficiency is in part determined by the liquid flow pattern and the throughput by the liquid froth height which in turn depends on the liquid hold-up and vapour velocity. This thesis describes experimental work on sieve trays in an air-water simulator, 2.44 m in diameter. The liquid flow pattern, for flow rates similar to those used in commercial scale distillation, was observed experimentally by direct observation; by water-cooling, to simulate mass transfer; use of potassium permanganate dye to observe areas of longer residence time; and by height of clear liquid measurements across the tray and in the downcomer using manometers. This work presents experiments designed to evaluate flow control devices proposed to improve the gas liquid interaction and hence improve the tray efficiency and throughput. These are (a) the use of intermediate weirs to redirect liquid to the sides of the tray so as to remove slow moving/stagnant liquid and (b) the use of vapour-directing slots designed to use the vapour to cause liquid to be directed towards the outlet weir thus reducing the liquid hold-up at a given rate i.e. increased throughput. This method also has the advantage of removing slow moving/stagnant liquid. In the experiments using intermediate weirs, which were placed in the centre of the tray. it was found that in general the effect of an intermediate weir depends on the depth of liquid downstream of the weir. If the weir is deeper than the downstream depth it will cause the upstream liquid to be deeper than the downstream liquid. If the weir is not as deep as deep as the downstream depth it may have little or no effect on the upstream depth. An intermediate weir placed at an angle to the direction of flow of liquid increases the liquid towards the sides of the tray without causing an increase in liquid hold-up/ froth height. The maximum proportion of liquid caused to flow sideways by the weir is between 5% and 10%. Experimental work using vapour-directing slots on a rectangular sieve tray has shown that the horizontal momentum that is imparted to the liquid is dependent upon the size of the slot. If too much momentum is transferred to the liquid it causes hydraulic jumps to occur at the mouth of the slot coupled with liquid being entrained, The use of slots also helps to eliminate the hydraulic gradient across sieve trays and provides a more uniform froth height on the tray. By comparing the results obtained of the tray and point efficiencies, it is shown that a slotted tray reduces both values by approximately 10%. This reduction is due to the fact that with a slotted tray the liquid has a reduced residence time Ion the tray coupled also with the fact that large size bubbles are passing through the slots. The effectiveness of using vapour-directing slots on a full circular tray was investigated by using dye to completely colour the biphase. The removal of the dye by clear liquid entering the tray was monitored using an overhead camera. Results obtained show that the slots are successful in their aim of reducing slow moving liquid from the sides of the tray, The net effect of this is an increase in tray efficiency. Measurements of slot vapour-velocity found it to be approximately equal to the hole velocity.
Resumo:
The advent of the harmonic neutralised shunt Converter Compensator as a practical means of reactive power compensation in power transmission systems has cleared ground for wider application of this type of equipment. An experimental 24-pulse voltage sourced convector has been successfully applied in controlling the terminal power factor of a 1.5kW, 240V three phase cage rotor induction motor, whose winding has been used in place of the usual phase shifting transformers. To achieve this, modifications have been made to the conventional stator winding of the induction machine. These include an unconventional phase spread and facilitation of compensator connections to selected tapping points between stator coils to give a three phase winding with a twelve phase connection to the twenty four pulse converter. Theoretical and experimental assessments of the impact of these modifications and attachment of the compensator have shown that there is a slight reduction in the torque developed at a given slip and in the combined system efficiency. There is also an increase in the noise level, also a consequence of the harmonics. The stator leakage inductance gave inadequate coupling reactance between the converter and the effective voltage source, necessitating the use of external inductors in each of the twelve phases. The terminal power factor is fully controllable when the induction machine is used either as a motor or as a generator.
Resumo:
This thesis describes an investigation into methods for controlling the mode distribution in multimode optical fibres. The major contributions presented in this thesis are summarised below. Emerging standards for Gigabit Ethernet transmission over multimode optical fibre have led to a resurgence of interest in the precise control, and specification, of modal launch conditions. In particular, commercial LED and OTDR test equipment does not, in general, comply with these standards. There is therefore a need for mode control devices, which can ensure compliance with the standards. A novel device consisting of a point-load mode-scrambler in tandem with a mode-filter is described in this thesis. The device, which has been patented, may be tuned to achieve a wide range of mode distributions and has been implemented in a ruggedised package for field use. Various other techniques for mode control have been described in this work, including the use of Long Period Gratings and air-gap mode-filters. Some of the methods have been applied to other applications, such as speckle suppression and in sensor technology. A novel, self-referencing, sensor comprising two modal groups in the Mode Power Distribution has been designed and tested. The feasibility of a two-channel Mode Group Diversity Multiplexed system has been demonstrated over 985m. A test apparatus for measuring mode distribution has been designed and constructed. The apparatus consists of a purpose-built video microscope, and comprehensive control and analysis software written in Visual Basic. The system may be fitted with a Silicon camera or an InGaAs camera, for measurement in the 850nm and 130nm transmission windows respectively. A limitation of the measurement method, when applied to well-filled fibres, has been identified and an improvement to the method has been proposed, based on modelled Laguerre Gauss field solutions.
Resumo:
In this paper we propose a two phases control method for DSRC vehicle networks at road intersection, where multiple road safety applications may coexist. We consider two safety applications, emergency safety application with high priority and routine safety applications with low priority. The control method is designed to provide high availability and low latency for emergency safety applications while leave as much as possible bandwidth for routine applications. It is expected to be capable of adapting to changing network conditions. In the first phase of the method we use a simulation based offline approach to find out the best configurations for message rate and MAC layer parameters for given numbers of vehicles. In the second phase we use the configurations identified by simulations at roadside access point (AP) for system operation. A utilization function is proposed to balance the QoS performances provided to multiple safety applications. It is demonstrated that the proposed method can largely improve the system performance when compared to fixed control method.
Resumo:
Congestion control is critical for the provisioning of quality of services (QoS) over dedicated short range communications (DSRC) vehicle networks for road safety applications. In this paper we propose a congestion control method for DSRC vehicle networks at road intersection, with the aims of providing high availability and low latency channels for high priority emergency safety applications while maximizing channel utilization for low priority routine safety applications. In this method a offline simulation based approach is used to find out the best possible configurations of message rate and MAC layer backoff exponent (BE) for a given number of vehicles equipped with DSRC radios. The identified best configurations are then used online by an roadside access point (AP) for system operation. Simulation results demonstrated that this adaptive method significantly outperforms the fixed control method under varying number of vehicles. The impact of estimation error on the number of vehicles in the network on system level performance is also investigated.
Resumo:
Generation of stable dual and/or multiple longitudinal modes emitted from a single quantum dot (QD) laser diode (LD) over a broad wavelength range by using volume Bragg gratings (VBG's) in an external cavity setup is reported. The LD operates in both the ground and excited states and the gratings give a dual-mode separation around each emission peak of 5 nm, which is suitable as a continuous wave (CW) optical pump signal for a terahertz (THz) photomixer device. The setup also generates dual modes around both 1180m and 1260 nm simultaneously, giving four simultaneous narrow linewidth modes comprising two simultaneous difference frequency pump signals. (C) 2011 American Institute of Physics.
Resumo:
This article assesses the impact of education reform and the new public management (NPM) on the discretion of school teachers. The focal point of the study is Michael Lipsky's theory of discretion which casts public service professionals and others involved in service delivery as 'street-level bureaucrats' because their high degree of discretionary rule-making power enabled them to effectively make policy as well as implement it. The article considers the relationship between education reform and the NPM and focuses on the increased emphasis on skills-based teaching and changes in management and leadership in schools. The literature and survey of teachers demonstrate that discretion in the workplace has been eroded to such an extent due to a high degree of central regulation and local accountability as to question the applicability of Lipsky's model. The findings are based on the literature and a small survey undertaken by the author. © 2007 BELMAS.
Resumo:
This research investigates specific ash control methods to limit inorganic content within biomass prior to fast pyrolysis and effect of specific ash components on fast pyrolysis processing, mass balance yields and bio-oil quality and stability. Inorganic content in miscanthus was naturally reduced over the winter period from June (7.36 wt. %) to February (2.80 wt. %) due to a combination of senescence and natural leaching from rain water. September harvest produced similar mass balance yields, bio-oil quality and stability compared to February harvest (conventional harvest), but nitrogen content in above ground crop was to high (208 kg ha.-1) to maintain sustainable crop production. Deionised water, 1.00% HCl and 0.10% Triton X-100 washes were used to reduce inorganic content of miscanthus. Miscanthus washed with 0.10% Triton X-100 resulted in the highest total liquid yield (76.21 wt. %) and lowest char and reaction water yields (9.77 wt. % and 8.25 wt. % respectively). Concentrations of Triton X-100 were varied to study further effects on mass balance yields and bio-oil stability. All concentrations of Triton X-100 increased total liquid yield and decreased char and reaction water yields compared to untreated miscanthus. In terms of bio-oil stability 1.00% Triton X-100 produced the most stable bio-oil with lowest viscosity index (2.43) and lowest water content index (1.01). Beech wood was impregnated with potassium and phosphorus resulting in lower liquid yields and increased char and gas yields due to their catalytic effect on fast pyrolysis product distribution. Increased potassium and phosphorus concentrations produced less stable bio-oils with viscosity and water content indexes increasing. Fast pyrolysis processing of phosphorus impregnated beech wood was problematic as the reactor bed material agglomerated into large clumps due to char formation within the reactor, affecting fluidisation and heat transfer.
Resumo:
Purpose – This paper aims to consider how climate change performance is measured and accounted for within the performance framework for local authority areas in England adopted in 2008. It critically evaluates the design of two mitigation and one adaptation indicators that are most relevant to climate change. Further, the potential for these performance indicators to contribute to climate change mitigation and adaptation is discussed. Design/methodology/approach – The authors begin by examining the importance of the performance framework and the related Local Area Agreements (LAAs), which were negotiated for all local areas in England between central government and Local Strategic Partnerships (LSPs). This development is located within the broader literature relating to new public management. The potential for this framework to assist in delivering the UK's climate change policy objectives is researched in a two-stage process. First, government publications and all 150 LAAs were analysed to identify the level of priority given to the climate change indicators. Second, interviews were conducted in spring 2009 with civil servants and local authority officials from the English West Midlands who were engaged in negotiating the climate change content of the LAAs. Findings – Nationally, the authors find that 97 per cent of LAAs included at least one climate change indicator as a priority. The indicators themselves, however, are perceived to be problematic – in terms of appropriateness, accuracy and timeliness. In addition, concerns were identified about the level of local control over the drivers of climate change performance and, therefore, a question is raised as to how LSPs can be held accountable for this. On a more positive note, for those concerned about climate change, the authors do find evidence that the inclusion of these indicators within the performance framework has helped to move climate change up the agenda for local authorities and their partners. However, actions by the UK's new coalition government to abolish the national performance framework and substantially reduce public expenditure potentially threaten this advance. Originality/value – This paper offers an insight into a new development for measuring climate change performance at a local level, which is relatively under-researched. It also contributes to knowledge of accountability within a local government setting and provides a reference point for further research into the potential role of local actions to address the issue of climate change.
Resumo:
* This work was completed while the author was visiting the University of Limoges. Support from the laboratoire “Analyse non-linéaire et Optimisation” is gratefully acknowledged.