Objective The present study was aimed at estimating the doses received by physicians and patients during cerebral angiography procedures in a public hospital of Recife, PE, Brazil. Materials and Methods The study sample included 158 adult patients, and during the procedures the following parameters were evaluated: exposure parameters (kV, mAs), number of acquired images, reference air kerma value (Ka,r) and air kerma-area product (PKA). Additionally, the physicians involved in the procedures were evaluated as for absorbed dose in the eyes, thyroid, chest, hands and feet. Results The results demonstrated that the doses to the patients' eyes region were relatively close to the threshold for cataract occurrence. As regards the physicians, the average effective dose was 2.6 µSv, and the highest effective dose recorded was 16 µSv. Conclusion Depending on the number of procedures, the doses received by the physicians may exceed the annual dose limit for the crystalline lenses (20 mSv) established by national and international standards. It is important to note that the high doses received by the physicians are due to the lack of radiation protection equipment and accessories, such as leaded curtains, screens and protective goggles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Avaliar a situação atual da braquiterapia de alta taxa dose (BATD) realizada no Brasil para neoplasias do colo uterino, no que diz respeito aos aparelhos, métodos de planejamento, prescrições, fracionamentos e avaliações de dose nos órgãos de risco. Materiais e Métodos: Foi elaborado um questionário contendo questões de múltipla escolha, o qual, entre os meses de março de 2012 e maio de 2013, foi enviado a 89 instituições hospitalares de todo o Brasil que possuem equipamento de BATD. Resultados: Sessenta e um serviços responderam o questionário. Todas as regiões do País experimentaram aumento acentuado no número de serviços que oferecem BATD entre os anos de 2001 e 2013. Quanto aos planejamentos, apesar de 91% dos centros afirmarem que possuem softwares capazes de suportar planejamento tridimensional, o aparelho de raios X convencional foi apontado por 92% dos entrevistados como ferramenta de aquisição de imagens na rotina. Aproximadamente 35% dos entrevistados afirmaram que as sessões de braquiterapia são realizadas após a teleterapia. O esquema de quatro inserções de 7 Gy foi apontado como o mais praticado. Conclusão: Neste estudo percebeu-se que há dificuldade dos profissionais ao acesso às ferramentas de aquisição de imagens adjuvantes aos planejamentos tridimensionais, como tomografia computadorizada e ressonância magnética.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo:Diversos estudos foram publicados quanto ao uso de blindagens de bismuto para proteção de mamas em exames de tomografia computadorizada (TC), e até a redação deste artigo encontrou-se apenas uma publicação sobre blindagens de bário. O objetivo deste estudo foi caracterizar, pela primeira vez, uma manta plumbífera para proteção de mamas.Materiais e Métodos:Foram avaliadas a redução percentual da dose e a influência desta blindagem em parâmetros quantitativos da imagem. Medidas de dose foram feitas em um equipamento de TC com auxílio de fantomas específicos e detectores de radiação. Um software de processamento auxiliou na análise qualitativa, que consistiu em avaliar a variação no número médio de TC e do ruído nas imagens.Resultados:Uma redução de dose na entrada em até 30% e do CTDIvol em até 17% foi encontrada. Como previsto na literatura, a presença do algodão como objeto espaçador reduziu significativamente os artefatos presentes na imagem. Em todas as medidas realizadas foi constatado aumento do número médio de TC e do ruído das imagens na presença da manta.Conclusão:Como esperado, os dados encontrados para a blindagem com chumbo foram da mesma ordem daqueles encontrados na literatura para blindagem com bismuto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le traitement médicamenteux du syndrome de Cushing secondaire à une hyperplasie surrénalienne macro-nodulaire bilatérale (bilateral macronodular adrenal hyperplasia, (BMAH)) est généralement administré pour une période limitée avant de procéder à l'exérèse chirurgicale des surrénales. Les antagonistes des récepteurs surrênaïïens aberrants se sont révélés inefficaces à long terme pour empêcher la surrénalectomie. Nous reportons le cas d'une patiente avec BMAH traitée durant 10 ans par des petites doses de kétoconazole, afin de contrôler la sécrétion de Cortisol. A l'âge de 48 ans, elle a présenté des céphalées et une hypertension artérielle. Les investigations ont donné les résultats suivants: absence de signes cliniques de syndrome de Cushing ; hyperplasie nodulaire des surrénales ; valeurs normales de la creatinine, le potassium et l'aldostérone plasmatiques ; valeurs normales des métanéphrines et de l'aldostérone urinaires ; élévation du Cortisol libre et des métabolites stéroïdiens urinaires ; et suppression de l'ACTH et de l'activité de la rénine plasmatiques. Un protocole de dépistage des récepteurs surrénaliens aberrants n'a pas montré de dépendance hormonale illégitime. Le kétoconazole a permis une normalisation rapide du Cortisol et de l'ACTH avec un effet qui persiste après 10 ans de traitement, tandis que l'imagerie surrénalienne ne montre pas de changement de taille et d'aspect de celles-ci. La sécrétion stéroidienne chez les patients présentant une BMAH est moins importante que celle de surrénales normales ou de tumeurs secrétrices et peut être contrôlée avec de petites doses de kétoconazole. Ce traitement, bien toléré, constitue une alternative au traitement chirurgical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:In the present study, the authors investigated the in vitrobehavior of radio-resistant breast adenocarcinoma (MDA-MB-231) cells line and radiosensitive peripheral blood mononuclear cells (PBMC), as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy.Materials and Methods:The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed.Results:Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation.Conclusion:Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The ongoing Ebola outbreak led to accelerated efforts to test vaccine candidates. On the basis of a request by WHO, we aimed to assess the safety and immunogenicity of the monovalent, recombinant, chimpanzee adenovirus type-3 vector-based Ebola Zaire vaccine (ChAd3-EBO-Z). METHODS: We did this randomised, double-blind, placebo-controlled, dose-finding, phase 1/2a trial at the Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland. Participants (aged 18-65 years) were randomly assigned (2:2:1), via two computer-generated randomisation lists for individuals potentially deployed in endemic areas and those not deployed, to receive a single intramuscular dose of high-dose vaccine (5 × 10(10) viral particles), low-dose vaccine (2·5 × 10(10) viral particles), or placebo. Deployed participants were allocated to only the vaccine groups. Group allocation was concealed from non-deployed participants, investigators, and outcome assessors. The safety evaluation was not masked for potentially deployed participants, who were therefore not included in the safety analysis for comparison between the vaccine doses and placebo, but were pooled with the non-deployed group to compare immunogenicity. The main objectives were safety and immunogenicity of ChAd3-EBO-Z. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT02289027. FINDINGS: Between Oct 24, 2014, and June 22, 2015, we randomly assigned 120 participants, of whom 18 (15%) were potentially deployed and 102 (85%) were non-deployed, to receive high-dose vaccine (n=49), low-dose vaccine (n=51), or placebo (n=20). Participants were followed up for 6 months. No vaccine-related serious adverse events were reported. We recorded local adverse events in 30 (75%) of 40 participants in the high-dose group, 33 (79%) of 42 participants in the low-dose group, and five (25%) of 20 participants in the placebo group. Fatigue or malaise was the most common systemic adverse event, reported in 25 (62%) participants in the high-dose group, 25 (60%) participants in the low-dose group, and five (25%) participants in the placebo group, followed by headache, reported in 23 (57%), 25 (60%), and three (15%) participants, respectively. Fever occurred 24 h after injection in 12 (30%) participants in the high-dose group and 11 (26%) participants in the low-dose group versus one (5%) participant in the placebo group. Geometric mean concentrations of IgG antibodies against Ebola glycoprotein peaked on day 28 at 51 μg/mL (95% CI 41·1-63·3) in the high-dose group, 44·9 μg/mL (25·8-56·3) in the low-dose group, and 5·2 μg/mL (3·5-7·6) in the placebo group, with respective response rates of 96% (95% CI 85·7-99·5), 96% (86·5-99·5), and 5% (0·1-24·9). Geometric mean concentrations decreased by day 180 to 25·5 μg/mL (95% CI 20·6-31·5) in the high-dose group, 22·1 μg/mL (19·3-28·6) in the low-dose group, and 3·2 μg/mL (2·4-4·9) in the placebo group. 28 (57%) participants given high-dose vaccine and 31 (61%) participants given low-dose vaccine developed glycoprotein-specific CD4 cell responses, and 33 (67%) and 35 (69%), respectively, developed CD8 responses. INTERPRETATION: ChAd3-EBO-Z was safe and well tolerated, although mild to moderate systemic adverse events were common. A single dose was immunogenic in almost all vaccine recipients. Antibody responses were still significantly present at 6 months. There was no significant difference between doses for safety and immunogenicity outcomes. This acceptable safety profile provides a reliable basis to proceed with phase 2 and phase 3 efficacy trials in Africa. FUNDING: Swiss State Secretariat for Education, Research and Innovation (SERI), through the EU Horizon 2020 Research and Innovation Programme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: CD103 is a specific integrin present on some CD4+ lymphocytes of the mucosal immune system. It has been hypothesized that most CD4+ lymphocytes in pulmonary sarcoidosis do not originate from mucosal sites but from redistribution from the peripheral blood, and therefore do not bear the CD103 integrin. Several studies have suggested that a low CD103+ percentage among bronchoalveolar lavage (BAL) CD4+ lymphocytes discriminates between sarcoidosis and other causes of lymphocytic alveolitis, but contradictory data exist. Methods: We reviewed 1151 consecutive patients with BAL lymphocytosis >10% and flow cytometry performed between 2006 and 2014. 944 cases were excluded due to poor BAL quality (n= 97), unavailable clinical data (n= 760), or unclear diagnosis (n= 87). The remaining 207 patients were grouped into 9 diagnostic categories. To assess the discriminative value of the CD103+CD4+/CD4+ ratio to distinguish sarcoidosis from the other entities, area under ROC curves (AUC) were determined. Results: Sarcoidosis patients (n=53) had a lower CD103+CD4+/CD4+ ratio than the other diagnostic categories. AUC was 62% for sarcoidosis compared to all other patients and 69% for sarcoidosis compared to other interstitial lung diseases. When combining CD103+CD4+/CD4+ and CD4+/CD8+ ratios, AUC increased to 76% and 78% respectively. When applying published cut-offs from 4 previous studies to our population, AUC varied between 54 and 73%. Conclusions: The CD103+CD4+/CD4+ ratio does not accurately discriminate between sarcoidosis and other causes of lymphocytic alveolitis, neither alone nor in combination with CD4+/CD8+ ratio, and is not a relevant marker for the diagnosis of sarcoidosis.