962 resultados para Discretely generated


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical success of fiber posts has been attributed to their lower elastic modulus. The tested hypothesis was that fiber posts could lead to lower risk of post debonding and lower risk of root fracture, despite an increase in root stresses. Stress analyses were carried out with a 3D finite element model of a premolar restored with a metallic or a fiber post. Bonded and non-bonded post/cement interface conditions were simulated. We calculated risk-of-fracture indices by determining the highest principal stress values divided by the tensile strength. Shear stresses along the post/cement interface were analyzed for the bonded models. Compared with the premolar restored with a metallic post, the fiber post generated lower stresses along the interface and higher stresses in the root. However, with the fiber post, fracture was less likely to occur in the root, since its core and post fracture indices were higher.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The definition of an optimal elastic modulus for a post is controversial. This work hypothesized that the influence of the posts` elastic modulus on dentin stress concentration is dependent on the load direction. The objective was to evaluate, using finite element analysis, the maximum principal stress (sigma(max)) on the root, using posts with different elastic modulus submitted to different loading directions. Nine 3D models were built, representing the dentin root, gutta-percha, a conical post and the cortical bone. The softwares used were: MSC.PATRAN2005r2 (preprocessing) and MSC.Marc2005r2 (processing). Load of 100 N was applied, varying the directions (0 degrees, 45 degrees and 90 degrees) in relation to the post`s long axis. The magnitude and direction of the sigma(max) were recorded. At the 45 degrees and 90 degrees loading, the highest values of sigma(max) were recorded for the lowest modulus posts, on the cervical region, with a direction that suggests debonding of the post. For the 0 degrees loading, the highest values of sigma(max) were recorded for higher modulus posts, on the apical region, and the circumferential direction suggests vertical root fracture. The hypothesis was accepted: the effect of the elastic modulus on the magnitude and direction of the sigma(max) generated on the root was dependent on the loading direction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The stress intensity factor threshold (K(IO)) is related to the stress level at which cracks start to grow stably, causing the weakening of porcelain prostheses during their use. The values of K(IO) of seven dental porcelains (with and without reinforcing leucite crystal, KAlSi(2)O(6)) stored in air (22 degrees C, 60% relative humidity) and artificial saliva (37 degrees C) were determined by measuring the crack growth velocity of radial cracks generated at the corner of Vickers indentations. The results of K(IO) were correlated with the leucite content, fracture toughness (K(Ic)), and chemical composition of the porcelains. It was observed that K(IO) increased with the increase of leucite content (only for the leucite-based porcelains) and with the increase of K(Ic). The increase in Al(2)O(3) content or the decrease in the alkali oxide (K(2)O and Na(2)O) content of the material`s glassy matrix tended to increase the K(IO) values. Storage media (air and saliva) did not significantly affect the K(IO) of porcelains tested, indicating that the control parameter of K(IO) value was not the water content of the storage media.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Detection and quantification of human papillomavirus (HPV) may help in predicting the evolution of HPV infection and progression of associated lesions. Objectives: We propose a novel protocol using consensus primers GP5+/6+ in a SYBR Green quantitative real-time (Q-RT) polymerase chain reaction (PCR). The strategy permits screening for HPV infection and viral load quantification simultaneously. Study design: DNA from 153 archived cervical samples, previously tested for HPV detection by GP5+/6+ PCR and typed by EIA-RLB (enzyme immunoassay-reverse line blot) or sequence analysis, was analysed using SYBR Green Q-RT PCR. Melting temperature assay (T(m)) and cycle threshold (C(t)) were used to evaluate HPV positivity and viral load. The T(m) in the range of 77-82 degrees C was considered to be positive for HPV-DNA. HPV results generated through GP5+/6+ conventional PCR were considered the gold standard against which sensitivity and specificity of our assay were measured. Results: Out of 104 HPV positive samples, 100 (96.2%) were also determined as positive by SYBR Green Q-RT PCR; of the 49 HPV-negative samples, all were determined as negative. There was an excellent positivity agreement (K = 0.94) between the SYBR Green Q-RT and the previous methods employed. The specificity and sensitivity were 100% and 96.2%, respectively. Comparison of SYBR Green Q-RT and TaqMan oligo-probe technologies gave an excellent concordance (pc = 0.95) which validated the proposed strategy. Conclusions: We propose a sensitive and easy-to-perform technique for HPV screening and viral load quantification simultaneously. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrical stimulation generated by the Cochlear Implant (CI) may improve the neural synchrony and hence contribute to the development of auditory skills in patients with Auditory Neuropathy / Auditory Dyssynchrony (AN/AD). Aim: Prospective cohort cross-sectional study to evaluate the auditory performance and the characteristics of the electrically evoked compound action potential (ECAP) in 18 children with AN/AD and cochlear implants. Material and methods: The auditory perception was evaluated by sound field thresholds and speech perception tests. To evaluate ECAP`s characteristics, the threshold and amplitude of neural response were evaluated at 80Hz and 35Hz. Results: No significant statistical difference was found concerning the development of auditory skills. The ECAP`s characteristics differences at 80 and 35Hz stimulation rate were also not statistically significant. Conclusion: The CI was seen as an efficient resource to develop auditory skills in 94% of the AN/AD patients studied. The auditory perception benefits and the possibility to measure ECAP showed that the electrical stimulation could compensate for the neural dyssynchrony caused by the AN/AD. However, a unique clinical procedure cannot be proposed at this point. Therefore, a careful and complete evaluation of each AN/AD patient before recommending a Cochlear Implant is advised. Clinical Trials: NCT01023932

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies on mechanisms underlying the differentiation of dental pulp stem cells are critical for the understanding of the biology of odontogenesis and for dental tissue engineering. Here, we tested the hypothesis that stem cells from exfoliated deciduous teeth (SHED) differentiate into functional odontoblasts and endothelial cells. SHED were seeded in tooth slice/scaffolds and implanted subcutaneously into immunodeficient mice. SHED differentiated into functional odontoblasts that generated tubular dentin, as determined by tetracycline staining and confocal microscopy. These cells also differentiated into vascular endothelial cells, as determined by beta-galactosidase staining of LacZ-tagged SHED. In vitro, vascular endothelial growth factor (VEGF) induced SHED to express VEGFR2, CD31, and VE-Cadherin (markers of endothelium) and to organize into capillary-like sprouts. VEGF induced ERK and AKT phosphorylation (indicative of differentiation), while inhibiting phosphorylation of STAT3 (indicative of `stemness`). Collectively, this work demonstrates that SHED can differentiate into angiogenic endothelial cells and odontoblasts capable of generating tubular dentin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article investigates the researcher's work in the coproduction (or not) of complaint sequences in research interviews. Using a conversation analytic approach, we show how the interviewer's management of complaint sequences in a research setting is consequential for subsequent talk and thus directly affects the data generated. In the examples shown here, researchers sharing cocategorial incumbency with respondents may well provide spaces for research participants to formulate complaints. This article examines sequences of talk surrounding complaints to show how researchers generate complaints (or not) and handle unsafe complaints. Researchers are able to provoke specific types of accounts from respondents, whereas their respondents may actively resist the researchers' direction. For researchers using the interview as a method of data generation, examination of complaint sequences and how these appear in interview data provides insight into how interview talk is coproduced and managed within a socially situated setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft fur Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine whether para-chloroaniline (PCA) and/or reactive oxygen species (ROS) are generated by chlorhexidine (CHX) alone or after CHX is mixed with calcium hydroxide at different time points. Mass spectrometry was performed to detect PCA in samples of 0.2% CHX and Ca(OH)2 mixed with 0.2% CHX. High-performance liquid chromatography was used to confirm the presence of CHX in the mixture with Ca(OH)2. The samples were analyzed immediately after mixing and after 7 and 14 days. During the intervals of the experiment, the samples were maintained at 36.5 degrees C and 95% relative humidity. PCA was detected in the 0.2% CHX solution after 14 days. The mixture of CHX with Ca(CH)2 liberated ROS at all time points, but no traces of CHX were present in the mixture as a result of immediate degradation of the CHX. (J Endod 2008;34:1508-1514)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is no consensus in literature regarding the best plan for prosthetic rehabilitation with partial multiple adjacent implants to minimize stress generated in the bone-implant interface. The aim of this study was to evaluate the biomechanical behavior of cemented fixed partial dentures, splinted and nonsplinted, on Morse taper implants and with different types of coating material (ceramic and resin), using photoelastic stress analysis. A photoelastic model of an interposed edentulous space, missing a second premolar and a first molar, and rehabilitated with 4 different types of cemented crowns and supported by 2 adjacent implants was used. Groups were as follows: UC, splinted ceramic crowns; IC, nonsplinted ceramic crowns; UR, splinted resin crowns; and IR, nonsplinted resin crowns. Different vertical static loading conditions were performed: balanced occlusal load, 10 kgf; simultaneous punctiform load on the implanted premolar and molar, 10 kgf; and alternate punctiform load on the implanted premolar and molar, 5 kgf. Changes in stress distribution were analyzed in a polariscope, and digital photographs were taken of each condition to allow comparison of stress pattern distribution around the implants. Cementation of the fixed partial dentures generated stresses between implants. Splinted restorations distributed the stresses more evenly between the implants than nonsplinted when force was applied. Ceramic restorations presented better distribution of stresses than resin restorations. Based on the results obtained, it was concluded that splinted ceramic restorations promote better stress distribution around osseointegrated implants when compared with nonsplinted crowns; metal-ceramic restorations present less stress concentration and magnitude than metal-plastic restorations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A social identity theory of leadership is described that views leadership as a group process generated by social categorization and prototype-based depersonalization processes associated with social identity. Group identification, as self-categorization, constructs an intragroup prototypicality gradient that invests the most prototypical member with the appearance of having influence; the appearance arises because members cognitively and behaviorally conform to the prototype. The appearance of influence becomes a reality through depersonalized social attraction processes that make followers agree and comply with the leader's ideas and suggestions. Consensual social attraction also imbues the leader with apparent status and creates a status-based structural differentiation within the group into leader(s) and followers, which has characteristics of unequal status intergroup relations. In addition, a fundamental attribution process constructs a charismatic leadership personality for the leader, which further empowers the leader and sharpens the leader-follower status differential. Empirical support for the theory is reviewed and a range of implications discussed, including intergroup dimensions, uncertainty reduction and extremism, power, and pitfalls of prototype-based leadership.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

I Vasorelaxant properties of three nitric oxide (NO) donor drugs (glyceryl trinitrate, sodium nitroprusside and spermine NONOate) in mouse aorta (phenylephrine pre-contracted) were compared with those of endothelium-derived NO (generated with acetylcholine), NO free radical (NO; NO gas solution) and nitroxyl ion (NO-; from Angeli's salt). 2 The soluble guanylate cyclase inhibitor, ODQ (1H-(1,2,4-)oxadiazolo(4,3-a)-quinoxalin-1-one; 0.3, 1 and 10 muM), concentration-dependently inhibited responses to all agents. 10 muM ODQ abolished responses to acetylcholine and glyceryl trinitrate, almost abolished responses to sodium nitroprusside but produced parallel shifts (to a higher concentration range; no depression in maxima) in the concentration-response curves for NO gas solution, Angeli's salt and spermine NONOate. 3 The NO scavengers, carboxy-PTIO, (2-(4-carboxyphenyl)-4,4,5,5-tetramethyl-indazoline-1-oxyl-3-oxide; 100 muM) and hydroxocobalamin (100 muM), both inhibited responses to NO gas solution and to the three NO donor drugs, but not Angeli's salt. Hydroxocobalamin, but not carboxy-PTIO, also inhibited responses to acetylcholine. 4 The NO- inhibitor, L-cysteine (3 mm), inhibited responses to Angeli's salt, acetylcholine and the three NO donor drugs, but not NO gas solution. 5 The data suggest that, in mouse aorta, responses to all three NO donors involve (i) activation of soluble guanylate cyclase, but to differing degrees and (ii) generation of both NO and NO-. Glyceryl trinitrate and sodium nitroprusside, which generate NO following tissue bioactivation, have profiles resembling the profile of endothelium-derived NO more than that of exogenous NO. Spermine NONOate, which generates NO spontaneously outside the tissue, was the drug that most closely resembled (but was not identical to) exogenous NO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study investigates the somatotopic representation in the somatosensory thalamus of a megachiropteran bat. Using standard microelectrode mapping techniques, representational maps were generated for the ventrobasal (Vb) and posterior (Po) thalamic complexes of the Grey-headed flying fox. Anatomical tracing from neocortical injections provided additional data confirming the somatotopy found physiologically. A full representation of the body surface innervated by the trigeminal and spinal nerves was found. However, in contrast with other mammals, the representations of the forelimb and adjacent thoracic trunk within the thalamus were inverted. This means that the distal portions of the wing membrane and the tips of the digits were represented dorsally in Vb, and the thoracic trunk was represented ventrally In Po the digit tips were represented in the ventral most portion and the thoracic trunk in the dorsal portion of the nucleus. These results are discussed in relation to similarities of megachiropteran somatosensory thalamic nuclei to those of other mammalian species and in relation to the formation of thalamic somatotopic maps and fiber sorting.