882 resultados para CMOS Mixer
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
This project aimed to analyze the feasibility of the methane yield associated to the anaerobic digestion of brewery residues, checking whether the energetic balance of the system is favorable. The methane yield efficiency was calculated for the parameters of two papers that treated solids with a particle-size <1mm. Theses solids are not degraded in conventional treatment systems. Calculations were based in the reactions of anaerobic degradation of the macromolecules that compose brewery residues, considering the theoretical production and the effective production of methane. The results were 50.44% and 52.86%. Regarding to the energy balance of the anaerobic treatment, we noted the high influence of the selection and operating regime of electrical equipment over the potential energy. The best situation, in which the energetic self-sufficiency was reached, was observed when using the mixer under an intermittent regime (1min/h), without employing the heating recirculator, for the maximum organic loading of 4.0 gVS/L.day (days 248-258). In this case, the system would generate an amount of energy equal to 0.0356 kWh/day, able to overcome the energy required by the equipment in about 6.5 times. Moreover, we also noted the interference of the application of different solid loadings in the reactors, once the application of the higher organic load generated 5 times more energy than the application of the smaller one
Resumo:
This work aims to obtain plasma thin film composites with hydrophobic/hydrophilic alternated regions, which are useful for the production of miniaturized mixers. These regions were acquired by two different strategies: either the codeposition of TEOS and HFE plasma thin films or the exposition of TEOS plasma films to ultraviolet radiation (UVA and UVC). These films were characterized by several chemical and physical techniques. The refractive indexes vary from 1.4 to 1.7; infrared and photoelectron spectroscopy detect Si-O-Si and CHn species. Silicone-like structures with high or low number of amorphous carbon microparticles and with fluorinated organic clusters were produced. Cluster dimensions were in the 1-5 mm range and they are made of graphite or COF (carbon/oxygen/fluorine) compounds. Scanning electron and optical microscopy showed rough surfaces. Water contact angles were 90º; however, for TEOS films that value changed after 6 hr of UVC exposure. Moreover, after UV exposure, organic polar compounds could be adsorbed in those films and water was not. The passive mixer performance was simulated using the FemLab 3.2® program and was tested with 20 nm thick films on a silicon wafer, showing the capacity of these films to be used in such devices.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A CMOS/SOI circuit to decode PWM signals is presented as part of a body-implanted neurostimulator for visual prosthesis. Since encoded data is the sole input to the circuit, the decoding technique is based on a double-integration concept and does not require dc filtering. Nonoverlapping control phases are internally derived from the incoming pulses and a fast-settling comparator ensures good discrimination accuracy in the megahertz range. The circuit was integrated on a 2 mu m single-metal SOI fabrication process and has an effective area of 2mm(2) Typically, the measured resolution of encoding parameter a was better than 10% at 6MHz and V-DD=3.3V. Stand-by consumption is around 340 mu W. Pulses with frequencies up to 15MHz and alpha = 10% can be discriminated for V-DD spanning from 2.3V to 3.3V. Such an excellent immunity to V-DD deviations meets a design specification with respect to inherent coupling losses on transmitting data and power by means of a transcutaneous link.
Resumo:
Pós-graduação em Aquicultura - FCAV
Resumo:
This study aimed to evaluate the use of a mixer to determine the rheological properties of fluids. The mixer is comprised of an agitation tank and an anchor type impeller. The tests were performed with honey and fruit juices (orange, guava and peach). The rheological characterization was performed using data from the torque and rotation speed required for the operation of fluid agitation. Tests were also made with a concentric cylinder rotational viscometer with the samples being subjected to various shear rates. The rheological parameters were obtained from the flow curves fitted to the power law model. Analyses of results showed that the mixer can be used, within its limitations, to determine rheological properties.
Resumo:
The integration of CMOS cameras with embedded processors and wireless communication devices has enabled the development of distributed wireless vision systems. Wireless Vision Sensor Networks (WVSNs), which consist of wirelessly connected embedded systems with vision and sensing capabilities, provide wide variety of application areas that have not been possible to realize with the wall-powered vision systems with wired links or scalar-data based wireless sensor networks. In this paper, the design of a middleware for a wireless vision sensor node is presented for the realization of WVSNs. The implemented wireless vision sensor node is tested through a simple vision application to study and analyze its capabilities, and determine the challenges in distributed vision applications through a wireless network of low-power embedded devices. The results of this paper highlight the practical concerns for the development of efficient image processing and communication solutions for WVSNs and emphasize the need for cross-layer solutions that unify these two so-far-independent research areas.
Resumo:
The study of ionizing radiation effects on semiconductor devices is of great relevance for the global technological development and is a necessity in some strategic areas in Brazil. This work presents preliminary results of radiation effects in MOSFETs that were exposed to 3.2 Grad radiation dose produced by a 2.6-MeV proton beam. The focus of this work was to electrically characterize a Rectangular-Gate MOSFET (RGT) and a Circular-Gate MOSFET (CGT), manufactured with the On Semiconductor 0.5 mu m standard CMOS fabrication process and to verify a suitable geometry for space applications. During the experiment, I-DS x V-GS curves were measured. After irradiation, the RGT off-state current (I-OFF) increased approximately two orders of magnitude reaching practically the same value of the I-OFF in the CGT, which only doubled its value. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In this work we have studied the radiation effects on MOSFET electronic devices. The integrated circuits were exposed to 10 key X-ray radiation and 2.6 MeV energy proton beam. We have irradiated MOSFET devices with two different geometries: rectangular-gate transistor and circular-gate transistor. We have observed the cumulative dose provokes shifts on the threshold voltage and increases or decreases the transistor's off-state and leakage current. The position of the trapped charges in modern CMOS technology devices depends on radiation type, dose rate, total dose, applied bias and is a function of device geometry. We concluded the circular-gate transistor is more tolerant to radiation than the rectangular-gate transistor. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Composites of high-density biopolyethylene (HDBPE) obtained from ethylene derived from sugarcane ethanol and curaua fibers were formed by first mixing in an internal mixer followed by thermopressing. Additionally, hydroxyl-terminated polybutadiene (LHPB), which is usually used as an impact modifier, was mainly used in this study as a compatibilizer agent. The fibers, HDBPE and LHPB were also compounded using an inter-meshing twin-screw extruder and, subsequently, injection molded. The presence of the curaua fibers enhanced some of the properties of the HDBPE, such as its flexural strength and storage modulus. SEM images showed that the addition of LHPB improved the adhesion of the fiber/matrix at the interface, which increased the impact strength of the composite. The higher shear experienced during processing probably led to a more homogeneous distribution of fibers, making the composite that was prepared through extruder/injection molding more resistant to impact than the composite processed by the internal mixer/thermopressing. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Nowadays, the attainment of microsystems that integrate most of the stages involved in an analytical process has raised an enormous interest in several research fields. This approach provides experimental set-ups of increased robustness and reliability, which simplify their application to in-line and continuous biomedical and environmental monitoring. In this work, a novel, compact and autonomous microanalyzer aimed at multiwavelength colorimetric determinations is presented. It integrates the microfluidics (a three-dimensional mixer and a 25 mm length "Z-shape" optical flow-cell), a highly versatile multiwavelength optical detection system and the associated electronics for signal processing and drive, all in the same device. The flexibility provided by its design allows the microanalyzer to be operated either in single fixed mode to provide a dedicated photometer or in multiple wavelength mode to obtain discrete pseudospectra. To increase its reliability, automate its operation and allow it to work under unattended conditions, a multicommutation sub-system was developed and integrated with the experimental set-up. The device was initially evaluated in the absence of chemical reactions using four acidochromic dyes and later applied to determine some key environmental parameters such as phenol index, chromium(VI) and nitrite ions. Results were comparable with those obtained with commercial instrumentation and allowed to demonstrate the versatility of the proposed microanalyzer as an autonomous and portable device able to be applied to other analytical methodologies based on colorimetric determinations.