978 resultados para 3D gloves for footwear design
Resumo:
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Resumo:
Este estágio, realizado na CrowdProcess, consistiu em integrar a equipa da empresa, trabalhando na área do Design de Comunicação, Web e Gráfico, integrado no Departamento de Comunicação da empresa. A CrowdProcess é uma plataforma de computação distribuída que utiliza o poder de processamento dos browsers ligados para correr tarefas de computação distribuída. Uma vez que se trata de um produto online, a maioria do trabalho desenvolvido diz respeito a design e desenvolvimento web e apenas uma pequena parte dedicada a design gráfico. O trabalho foi desenvolvido com as linguagens HTML, CSS e JavaScript. Foram tidos em consideração os princípios de Design, Usabilidade e Arquitectura de Informação, com principal foco na prototipagem dos vários objectos desenvolvidos.
Resumo:
ICAD2014, Campus de Caparica, Portugal
Resumo:
Micro/nano wrinkled patterns on cross-linked urethane/urea polymeric flexible free standing films with two soft segments, polypropylene oxide and polybutadiene, can be induced by UV-irradiation. The ability to write/erase these 3D structures, in a controlled manner, is the main focus of this work. The imprinting of the wrinkled structures was accomplished by swelling in an appropriate solvent followed by drying the membranes after the cross-linking process and UV irradiation. The surface tailoring of the elastomeric membranes was imaged by optical microscopy, scanning electronic microscopy and by atomic force microscopy. To erase the wrinkled structures the elastomers were swollen. The swelling as well as the sol/gel fraction and the UV radiation were tuned in order to control the wrinkles characteristics. It was found that the wrinkles wavelength, in the order of microns (1±0,25μm), was stamped by the UV radiation intensity and exposure time while the wrinkles' amplitude, in the order of nanometers (150-450 nm), was highly dependent on the swelling and sol/gel fraction. A prototype for volatile organic compounds detection was developed taking advantage of the unique 3D micro/nano wrinkles features.
Resumo:
Paper presented at the Colloquium Gerpisa 2013, Paris (http://gerpisa.org/node/2085), Session n°: 19 New kinds of mobility: old and new business models
Resumo:
Num mundo em crescente evolução é necessário tentar melhorar as condições de saúde global. Um factor importante para a prevenção e tratamento de doenças é o seu correcto diagnóstico. Uma vez que nem todos os países têm a mesma capacidade económica, existe a necessidade de se criar testes rápidos e baratos que possam ser acessíveis no mundo inteiro. Os point-of-care tests, como é o caso dos biossensores de glucose vastamente utilizados na monitorização da diabetes, apresentam uma solução para este problema. Os biossensores impressos em papel, em particular, são uma ferramenta que pode vir a ser muito útil na construção destes testes rápidos tornando-os mais “amigos do ambiente” e reduzindo os seus custos. O objectivo deste trabalho foi desenvolver biossensores enzimáticos, de segunda geração, impressos em papel e baseados na enzima glucose oxidase, para a detecção da glucose. Inicialmente foi feito um estudo de possíveis mediadores a utilizar, tendo-se escolhido o ferroceno por apresentar um limite de detecção adequado, ter apresentado um valor de potencial de redução relativamente baixo, 0.232 V vs pseudo ref. Ag/AgCl, ser um composto fácil de obter e com custos reduzidos. Os dispositivos baseiam-se em canais microfluídicos, eléctrodos e ligações eléctricas fabricadas em substrato de papel, utilizando as técnicas de impressão a cera, screen printing e inkjet printing. O circuito constituinte destes dispositivos foi feito recorrendo a tintas condutoras, sendo que, à tinta utilizada para o eléctrodo de trabalho foi incorporado o ferroceno. Sobre o eléctrodo de trabalho foi impressa glucose oxidase, utilizando a técnica de inkjet printing. Os eléctrodos fabricados apresentaram resposta à glucose, muito embora com baixa reprodutibilidade, podendo esta ser causada pela falta de controlo na preparação dos mesmos (manufactura manual e variabilidade da viscosidade da pasta usada no eléctrodo de trabalho). A técnica de inkjet printing em enzimas é ainda muito recente, existindo ainda alguns aspectos, como o seu efeito na actividade da enzima, que não foram avaliados neste projecto, mas que no futuro deverão ser estudados. Podemos concluir que, os eléctrodos deram uma resposta electroquímica consistente à adição de glucose, 8 mM- 30 mM, sendo que os mesmos foram reconhecidos no glucómetro comercial TRUETrackTM blood glucometer; no entanto, os valores de corrente dos dispositivos estavam abaixo do limite de detecção do instrumento.
Resumo:
A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.
Resumo:
In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.
Resumo:
The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.
Resumo:
The potential of human adenovirus vectors as vehicles for gene transfer with clinical applications in vaccination, cancer treatment and in many monogenic and acquired diseases has been demonstrated in several studies and clinical trials. However, the clinical use of these vectors can be limited by pre-existing humoral and cellular anti-capsid immunity. One way to circumvent this bottleneck while keeping the advantages of using adenovirus vectors is using non-human viruses such as Canine Adenovirus type 2 (CAV-2). Moreover, CAV-2 vectors present attractive features to develop potential treatment of neurodegenerative and ocular disorders. While the interest in CAV-2 vectors increases, scalable and robust production processes are required to meet the need for preclinical and possibly clinical uses.(...)
Resumo:
WEB DESIGN COMO FERRAMENTA DE COMUNICAÇÃO DIGITAL: DESIGN E DESENVOLVIMENTO DE SITES, UTILIZANDO O GESTOR DE CONTEÚDOS WORDPRESS; DESIGN DE CONTEÚDOS VISUAIS PARA O FACEBOOK DE UMA MARCA
Resumo:
NSBE - UNL
Resumo:
Field Lab in Entrepreneurial Innovative Ventures
Resumo:
A Engenharia de Tecidos surge da necessidade recorrente de regenerar ou recriar órgãos e tecidos danificados devido a vários tipos de trauma. A carência de funcionalidades resultante pode ser resolvida através da implantação de substitutos bio-sintéticos. O presente trabalho consiste na produção de matrizes porosas 3D baseadas em réplicas invertidas de cristais coloidais com futura aplicação em substituintes ósseos sintéticos para fraturas de não-união. O substituinte ósseo consiste numa estrutura denominada Inverse colloidal crystal (ICC), em que a sua organização singular resulta numa homogénea proliferação celular e num aumento das propriedades mecânicas, quando comparada com outros substituintes. O primeiro passo para a obtenção desta estrutura é a produção de microesferas de poliestireno, por uma técnica baseada em microfluídica. Posteriormente as microesferas são empacotadas resultando numa estrutura coesa com ligações entre microesferas vizinhas. O preenchimento dos espaços vazios entre microesferas pelo biomaterial pretendido e posterior remoção das microesferas dá origem à estrutura porosa do ICC. ICCs poliméricos (ϕCs = 1,00) e compósitos (ϕCs = 0,86 e ϕHA = 0,14; ϕCs = 0,67 e ϕHA = 0,33; ϕCs = ϕHA = 0,50) são produzidos e as suas propriedades mecânicas são testadas através de ensaios de compressão e comparadas com outros substituintes sintéticos. Para avaliação do comportamento dos materiais em contacto com meio biológico, foram realizados testes de citotoxicidade que revelaram uma viabilidade celular acima dos 80% em todos os ICCs.
Resumo:
The development of human cell models that recapitulate hepatic functionality allows the study of metabolic pathways involved in toxicity and disease. The increased biological relevance, cost-effectiveness and high-throughput of cell models can contribute to increase the efficiency of drug development in the pharmaceutical industry. Recapitulation of liver functionality in vitro requires the development of advanced culture strategies to mimic in vivo complexity, such as 3D culture, co-cultures or biomaterials. However, complex 3D models are typically associated with poor robustness, limited scalability and compatibility with screening methods. In this work, several strategies were used to develop highly functional and reproducible spheroid-based in vitro models of human hepatocytes and HepaRG cells using stirred culture systems. In chapter 2, the isolation of human hepatocytes from resected liver tissue was implemented and a liver tissue perfusion method was optimized towards the improvement of hepatocyte isolation and aggregation efficiency, resulting in an isolation protocol compatible with 3D culture. In chapter 3, human hepatocytes were co-cultivated with mesenchymal stem cells (MSC) and the phenotype of both cell types was characterized, showing that MSC acquire a supportive stromal function and hepatocytes retain differentiated hepatic functions, stability of drug metabolism enzymes and higher viability in co-cultures. In chapter 4, a 3D alginate microencapsulation strategy for the differentiation of HepaRG cells was evaluated and compared with the standard 2D DMSO-dependent differentiation, yielding higher differentiation efficiency, comparable levels of drug metabolism activity and significantly improved biosynthetic activity. The work developed in this thesis provides novel strategies for 3D culture of human hepatic cell models, which are reproducible, scalable and compatible with screening platforms. The phenotypic and functional characterization of the in vitro systems performed contributes to the state of the art of human hepatic cell models and can be applied to the improvement of pre-clinical drug development efficiency of the process, model disease and ultimately, development of cell-based therapeutic strategies for liver failure.