994 resultados para spontaneouly generated coherence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper is the result of a four-year-long project examining the concept and the policies of cultural diversity and the impact of digital media upon the regulatory environment where the goal of cultural diversity is to be achieved. The focus of the project was primarily on the international level and in particular on the World Trade Organization (WTO) and the United Nations Educational Scientific and Cultural Organization (UNESCO), which also epitomise the often framed as opposing pair of trade and culture. In the broad context of the project, we sought to pinpoint the essential elements of an international trade-and-culture conducive framework that can also overcome the existing fragmentation in the field of international law and move towards more coherent solutions. In a narrower context, we sketched some possible improvements to the WTO law that can make it more suitable to the digital networked environment and to the objective of diverse media that some states aspire. . Our key messages are: (1) Neither the WTO nor UNESCO currently offers appropriate solutions to the trade and culture predicament and allows for efficient protection and promotion of cultural diversity; (2) The trade and culture discourse is overly politicised and due to the related path dependencies, a number of feasible solutions appears presently blocked; (3) The digital networked environment has profoundly changed the ways cultural content is created, distributed, accessed and consumed, and may thus offer good reasons to reassess and readjust the present models of governance; (4) Access to information appears to be the most appropriate focus of the discussions with view to protecting and promoting cultural diversity in the new digital media setting, both in local and global contexts; (5) This new focal point demands also broadening and interconnecting the policy discussions, which should go beyond the narrow scope of audiovisual media services, but cautiously account for the developments at the network and applications levels, as well as in other domains, such as most notably intellectual property rights protection; (6) There are various ways in which the WTO can be made more conducive to cultural policy considerations and these include, among others, improved and updated services classifications; enhanced legal certainty with regard to digitally transferred goods and services; incorporation of rules on subsidies for services and on competition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the increases in cognitive capacities of adolescent humans are concurrent with significant cortical restructuring, functional associations between these phenomena are unclear. We examined the association between cortical development, as measured by the sleep EEG, and cognitive performance in a sample of 9/10 year olds followed up 1 to 3 years later. Our cognitive measures included a response inhibition task (Stroop), an executive control task (Trail Making), and a verbal fluency task (FAS). We correlated sleep EEG measures of power and intra-hemispheric coherence at the initial assessment with performance at that assessment. In addition we correlated the rate of change across assessments in sleep EEG measures with the rate of change in performance. We found no correlation between sleep EEG power and performance on cognitive tasks for the initial assessment. In contrast, we found a significant correlation of the rate of change in intra-hemispheric coherence for the sigma band (11 to 16 Hz) with rate of change in performance on the Stroop (r = 0.61; p<0.02) and Trail Making (r =  -0.51; p<0.02) but no association for the FAS. Thus, plastic changes in connectivity (i.e., sleep EEG coherence) were associated with improvement in complex cognitive function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ex vivo porcine retina laser lesions applied with varying laser power (20 mW–2 W, 10 ms pulse, 196 lesions) are manually evaluated by microscopic and optical coherence tomography (OCT) visibility, as well as in histological sections immediately after the deposition of the laser energy. An optical coherence tomography system with 1.78 um axial resolution specifically developed to image thin retinal layers simultaneously to laser therapy is presented, and visibility thresholds of the laser lesions in OCT data and fundus imaging are compared. Optical coherence tomography scans are compared with histological sections to estimate the resolving power for small optical changes in the retinal layers, and real-time time-lapse scans during laser application are shown and analyzed quantitatively. Ultrahigh-resolution OCT inspection features a lesion visibility threshold 40–50 mW (17 reduction) lower than for visual inspection. With the new measurement system, 42 of the lesions that were invisible using state-of-the-art ophthalmoscopic methods could be detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain electric mechanisms of temporary, functional binding between brain regions are studied using computation of scalp EEG coherence and phase locking, sensitive to time differences of few milliseconds. However, such results if computed from scalp data are ambiguous since electric sources are spatially oriented. Non-ambiguous results can be obtained using calculated time series of strength of intracerebral model sources. This is illustrated applying LORETA modeling to EEG during resting and meditation. During meditation, time series of LORETA model sources revealed a tendency to decreased left-right intracerebral coherence in the delta band, and to increased anterior-posterior intracerebral coherence in the theta band. An alternate conceptualization of functional binding is based on the observation that brain electric activity is discontinuous, i.e., that it occurs in chunks of up to about 100 ms duration that are detectable as quasi-stable scalp field configurations of brain electric activity, called microstates. Their functional significance is illustrated in spontaneous and event-related paradigms, where microstates associated with imagery- versus abstract-type mentation, or while reading positive versus negative emotion words showed clearly different regions of cortical activation in LORETA tomography. These data support the concept that complete brain functions of higher order such as a momentary thought might be incorporated in temporal chunks of processing in the range of tens to about 100 ms as quasi-stable brain states; during these time windows, subprocesses would be accepted as members of the ongoing chunk of processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). METHODS A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. RESULTS Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. CONCLUSIONS The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the implications of an Absorb bioresorbable vascular scaffold (Absorb BVS) on the morphology of the superficial plaques. Methods and results: Forty-six patients who underwent Absorb BVS implantation and 20 patients implanted with bare metal stents (BMS) who had serial optical coherence tomographic examination at baseline and follow-up were included in this analysis. The thin-capped fibroatheromas (TCFA) were identified in the device implantation regions and in the adjacent native coronary segments. Within all regions, circumferential locations of TCFA and calcific tissues were identified, and the neointimal thickness was measured at follow-up. At six to 12-month follow-up, only 8% of the TCFA detected at baseline were still present in the Absorb BVS and 27% in the BMS implantation segment (p=0.231). Sixty percent of the TCFA in native segments did not change their phenotype at follow-up. At short-term follow-up, significant reduction in the lumen area of the BMS was noted, which was higher compared to that reported in the Absorb BVS group (-2.11±1.97 mm2 vs. -1.34±0.99 mm2, p=0.026). In Absorb BVS, neointima tissue continued to develop at midterm follow-up (2.17±0.48 mm2 vs. 1.38±0.52 mm2, p<0.0001) and covered the underlying tissues without compromising the luminal dimensions (5.93±1.49 mm2 vs. 6.14±1.49 mm2, p=0.571) as it was accommodated by the expanded scaffold (8.28±1.74 mm2 vs. 7.67±1.28 mm2, p<0.0001). Conclusions: Neointimal tissue develops following either Absorb BVS or BMS implantation and shields lipid tissues. The neointimal response in the BMS causes a higher reduction of luminal dimensions compared to the Absorb BVS. Thus, Absorb BVS may have a value in the invasive re-capping of high-risk plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pre-clinical studies using murine models are critical for understanding the pathophysiological mechanisms underlying immune-mediated disorders such as Eosinophilic esophagitis (EoE). In this study, an optical coherence tomography (OCT) system capable of providing three-dimensional images with axial and transverse resolutions of 5 µm and 10 µm, respectively, was utilized to obtain esophageal images from a murine model of EoE-like disease ex vivo. Structural changes in the esophagus of wild-type (Tslpr(+/+) ) and mutant (Tslpr(-/-) ) mice with EoE-like disease were quantitatively evaluated and food impaction sites in the esophagus of diseased mice were monitored using OCT. Here, the capability of OCT as a label-free imaging tool devoid of tissue-processing artifacts to effectively characterize murine EoE-like disease models has been demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Senile scleral plaques (SSP) are sharply demarcated greyish areas located just anterior to the insertions of the horizontal rectus muscles and thus are frequently encountered during transscleral intravitreal injections. The aim of this study was to characterize SSP using enhanced depth imaging spectral domain anterior segment optical coherence tomography (OCT) in a cohort of patients attending intravitreal injection clinics. METHODS Prospective cross-sectional study of 380 patients attending the clinic for intravitreal injections at the Department of Ophthalmology at the Bern University Hospital. Thirty-two patients with SSP were identified and the anatomical features were assessed using anterior segment OCT. RESULTS In our patient cohort, we found a SSP prevalence of 8.2%. Senile scleral plaques were easily identifiable using anterior segment OCT and were found at the insertion sites of the horizontal recti muscles. The mean horizontal diameter was 2.2 mm (±760 μm SD), the mean vertical diameter was 3.3 mm (±144 μm SD), and the average surface area was 5.3 mm(2) (±0.4 mm(2) SD). The mean senile scleral plaque thickness was 0.6 mm (±149 μm SD). The mean distance from the limbus was 2.24 mm for nasally located SSP and 3.22 mm for temporally located SSP. CONCLUSION SSP are frequently encountered during intravitreal injections as they are located just anterior to the insertion sites of the horizontal recti muscles. Because the scleral stroma is rarefied and due to calcifications within SSP, these areas should be avoided when performing multiple intravitreal injections as this may result in rupture of the sclera.