893 resultados para peak-to-plateau ratio
Resumo:
The need for reduced intrinsic weight of structures and vehicles in the transportation industry has made aluminium research of interest. Aluminium has properties that are favourable for structural engineering, including good strength-to-weight ratio, corrosion resistance and machinability. It can be easily recycled saving energy used in smelting as compared to steel. Its alloys can have ultimate tensile strength of up to 750 MPa, which is comparable to steel. Aluminium alloys are generally weldable, however welding of high strength alloys like the 7xxx series pose considerable challenges. This paper presents research on the weldability of high strength aluminium alloys, principally the 7xxx series. The weldability with various weld processes including MIG, TIG, and FSW, is discussed in addition to consideration of joint types, weld defects and recommendations for minimizing or preventing weld defects. Experimental research was carried out on 7025-T6 and AW-7020 alloys. Samples were welded, and weld cross sections utilized in weld metallurgy studies. Mechanical tests were carried out including hardness tests and tensile tests. In addition, testing was done for the presence of Al2O3 on exposed aluminium alloy. It was observed that at constant weld heat input using a pulsed MIG system, the welding speed had little or no effect on the weld hardness. However, the grain size increased as the filler wire feed rate, welding current and welding speed increased. High heat input resulted in lower hardness of the weld profile. Weld preheating was detrimental to AW- 7020 welds; however, artificial aging was beneficial. Acceptable welds were attained with pulsed MIG without the removal of the Al2O3 layer prior to welding. The Al2O3 oxide layer was found to have different compositions in different aluminium alloys. These findings contribute useful additional information to the knowledge base of aluminium welding. The application of the findings of this study in welding will help reduce weld cost and improve high strength aluminium structure productivity by removing the need for pre-weld cleaning. Better understanding of aluminium weld metallurgy equips weld engineers with information for better aluminium weld design.
Resumo:
On this paper, we propose a change in the primary surplus' target by the government current account saving. That concept excludes public investment from primary surplus. However, of that change has raised a question about if government current account saving represents a sustainable fiscal policy. Thus, this paper analyses if the change in the primary surplus' target by the government current account saving implies a meaning modification on the debt-to-GDP ratio path. The empirical analysis, which is based on Brazilian monthly data for the period 1999-2005, suggests that the change in fiscal target does not mean a lack of sustain-ability.
Resumo:
Inflation target, real exchange rate and external crisis in a Kaleckian model. Which role should the real exchange rate play in an inflation target regime? In this paper this point is discussed from the point of view of the conditions required for avoiding an external crisis. With this objective, a dynamic Kaleckian model is presented focusing on the stability of the external debt to capital ratio. The main conclusion is that policy makers should monitor closely the evolution of the real exchange rate in order to make compatible the inflation target regime with external stability.
Resumo:
Kvantitatiivinen reaaliaikainen polymeraasiketjureaktio (engl. polymerase chain reaction, PCR) on osoittautunut käyttäjäystävällisimmäksi menetelmäksi nukleiinihapposekvenssien kvantitoimisessa. Tätä menetelmää voidaan herkistää pienempien DNA-pitoisuuksien havaitsemiseen käyttämällä hyväksi aikaerotteista fluorometriaa (engl. time-resolved fluorometry, TRF) ja luminoivia lantanidileimoja, joiden fluoresenssin pitkän eliniän ansiosta emission mittaus voidaan suorittaa vasta hetki virittävän valopulssin jälkeen, jolloin lyhytikäinen taustasäteily ehtii sammua. Tuloksena saadaan korkea signaali-taustasuhde. Tämän diplomityön tarkoituksena oli rakentaa TRF:än pystyvä reaaliaikainen PCR-laite, sillä tällaista laitetta ei ole markkinoilla tarjolla. Laite rakennettiin kehittämällä lämpökierrätin ja yhdistämällä se valmiiseen TRF:än kykenevään mittapäähän. Mittapään ja lämpökierrättimen hallitsemiseksi kehitettiin myös tietokoneohjelma. Valon tuottamiseksi ja mittaamiseksi haluttiin käyttää edullisia komponentteja, joten työssä käytettiin valmiin mittapään optiikkaa, jossa viritys tapahtuu hohtodiodilla (engl. light-emitting diode, LED) ja lantanidileiman emission mittaus fotodiodilla (engl. photodiode, PD) tai valomonistinputkella (engl. photomultiplier tube, PMT). Myös mittapään suorituskykyä tutkittiin. Työtä varten kehitettiin lämpökierrätin, joka koostui Peltier-elementillä lämmitettävästä PCR-putkitelineestä ja lämpökannesta. Mittalaitteen suorituskyvyn tutkimiseen käytettiin kelaattikomplementaatioon perustuvaa PCR-tuotteen havaitsemismenetelmää. Kelaattikomplementaatio perustuu kahteen erilliseen oligonukleotidimolekyyliin, joista toiseen on sidottu lantanidi-ioni ja toiseen valoa absorboiva ligandirakenne, jotka yhdessä muodostavat fluoresoivan kokonaisuuden. Kehitetyn lämpökierrättimen todettiin olevan tarpeeksi tarkka sekä tehokas ja sen lämmitys- ja jäähdytysnopeuden maksimeiksi saatiin 2,6 °C/sekunti. Detektorina käytetyn PD:n ei todettu olevan tarpeeksi herkkä emission havainnoimiseksi ja se korvattiin laitteessa PMT:llä. Käytetyllä PCR-määrityksellä kynnyssykleiksi (engl. threshold cycle, Ct) sekä kehitetylle että referenssilaitteelle saatiin 28,4 käyttämällä samaa 100 000 kopion DNA:n aloitusmäärää. Työssä osoitettiin, että on mahdollista kehittää edullisia komponentteja käyttävä, TRF:än pystyvä, reaaliaikainen PCR-laite, joka kykenee vastaavaan Ct-arvoon kuin vertailulaite. PD:n herkkyys ei kuitenkaan riittänyt. Tulokset olivat lupaavia, sillä LED- ja PD-teknologiat kehittyvät ja markkinoille on tullut myös muita komponentteja, joiden avulla on tulevaisuudessa mahdollista kehittää vielä herkempi laite.
Resumo:
This study examined the interactions between the reproductive status and the thermoregulatory responses during exercise in the cold in girls involved in competitive sports. Four girls with established menstrual cycles comprised the eumenorrheic menarcheal group (EM) and 5 non-menstruating girls comprised the pre-menarcheal group (PM). During the first visit maximal oxygen consumption, height, weight and percent body fat (%BF) were measured. The second visit involved: a determination of metabolic rate in thermoneutrality (21°C) involving 10-min rest and 20-min cycling (30% of VCL max), and a cold stress test (5°C, 40% humidity, <0.3 m/s air velocity) involving 20-min rest and 40-min cycling (30% of VCL max.). Subjects in the EM group were tested twice in the chamber during the follicular and luteal phases. Pre-menarcheal subjects were found to have significantly (p<0.05) lower core temperatures during the final stages of cold exposure. Overall, body fat was not significantly correlated with core temperature in the cold, however there was a significant surface-to-mass ratio difference between the groups. While in the follicular phase, EM girls had a higher core temperature during cold exposure. Therefore, reproductive hormonal status seems to be an important factor in terms of cold tolerance in females during adolescence.
Resumo:
The objective of this study was to examine the association between body
composition and arterial stiffuess in peri-pubescent boys and girls. Differences in arterial
distensibility were measured in 68 children (45 normal weight, 12 overweight, and 11
obese) between the ages of9 to 12 years. Weight classification was based on age and
gender-specific body mass index cut-offs, while pubertal maturation was self-reported
using Tanner staging. Distensibility was determined using two-dimensional, B-Mode
echo Doppler ultrasound to measure changes at the right common carotid artery (CCA)
diameter changes, while carotid pulse pressure (cPP) was measured at the left CCA by
applanation tonometry. One-way ANOV A analysis revealed significant differences
(p<0.001) in all anthropometric measures between the normal weight and overweight
children, as well as the normal weight and obese children. Body stature was only higher
in obese children compared to normal weight children (p<0.01). No significant
differences were found between groups regarding age or Tanner stage. Common carotid
artery distensibility showed a significant difference (p<0.01) between normal weight
children (0.008 ± 0.002 mmHg-1
) compared to obese children (0.005 ± 0.002 mmHg-1
),
with a borderline significant difference between the normal and overweight subjects
(p=0.06). There was no significant effect for gender between males and females across
all independent variables. The strongest determinants of distensibility in children were
cPP (r= -0.52, p
Resumo:
This study was undertaken to ascertain whether meromictic lakes could be differentiated from holomictic lakes on the basis of their surficial profundal sediments. Surface sediment cores (15 cm long) were collected from both the littoral and profundal zones of four meromictic and six holomictic lakes and analyzed for total number of fossil chironomid headcapsu~es, chlorophyll and carotenoid degradation products as well as \ iron and manganese concentrations. Littoral and profundal comparisons of the surface sediments were made between the two lake types using the Mann-Whitney U test. Iron, manganese and the iron to manganese ratio in the littoral sediments of meromictic lakes were significantly lower than those found in the littoral sediments of holomictic lakes. The observed differences are believed to represent an artifact of the significantly higher carbonate concentrations found in three of the four meromictic lakes studied. Profundal and littoral to profundal ratio comparison between holomictic and meromictic lakes suggest that the significantly lower iron and higher carotenoid concentrations in meromictic profundal sediments were a con~equence of meromixis. However, the overlap in distribution exhibited by both iron and carotenoid degradation products between the two lake types was sufficiently large in this study to nullify their use as a means of differentiating meromictic from holomictic lakes. A long core (4.25 m) was removed from the deepest part of the meromictic Crawford Lake (Ontario), sectioned at 5 cm intervals, and analyzed to assess when meromixis occurred, based on its fossil record. Temporal changes in the total number of chironomid headcapsules, and chlorophyll and carotenoid sediment degradation products were closely correlated with organic matter, indicating in my opinion that extensive redeposition of littoral chironomid headcapsules in the profundal zone has occurred. Temporal variations in carotenoid degradation products, in response to changes in organic matter, obscured increased preservation that may have occurred as a consequence of meromixis. Temporal variations in iron and manganese suggest that relatively stable redox conditions have existed throughout most of the lake's history. Therefore it would appear that Crawford Lake has been meromictic since its inception.
Resumo:
Introduction: The prevalence of coronary artery disease (CAD) is ever increasing in western industrialized societies. An individuals overall risk for CAD may be quantified by integrating a number of factors including, but not limited to, cardiorespiratory fitness, body composition, blood lipid profile and blood pressure. It might be expected that interventions aimed at improving any or all of these independent factors might improve an individual 's overall risk. To this end, the influence of standard endurance type exercise on cardiorespiratory fitness, body composition, blood lipids and blood pressure, and by extension the reduction of coronary risk factors, is well documented. On the other hand, interval training (IT) has been shown to provide an extremely powerful stimulus for improving indices of cardiorespiratory function but the influence of this training type on coronary risk factors is unknown. Moreover, the vast majority of studies investigating the effects of IT on fitness have used laboratory type training protocols. As a result of this, the influence of participation in interval-type recreational sports on cardiorespiratory fitness and coronary risk factors is unknown. Aims: The aim of the present study was to evaluate the effectiveness of recreational ball hockey, a sport associated with interval-type activity patterns, on indices of aerobic function and coronary risk factors in sedentary men in the approximate age range of 30 - 60 years. Individual risk factors were compiled into an overall coronary risk factor score using the Framingham Point Scale (FPS). Methods: Twenty-four sedentary males (age range 30 - 60) participated in the study. Subject activity level was assessed apriori using questionnaire responses. All subjects (experimental and control) were assessed to have been inactive and sedentary prior to participation in the study. The experimental group (43 ± 3 years; 90 ± 3 kg) (n = 11) participated in one season of recreational ball hockey (our surrogate for IT). Member of this group played a total of 16 games during an 11 week span. During this time, the control group (43 ± 2 years; 89 ± 2 kg) (n = 11) performed no training and continued with their sedentary lifestyle. Prior to and following the ball hockey season, experimental and control subjects were tested for the following variables: 1) cardiorespiratory fitness (as V02 Max) 2) blood lipid profile 3) body composition 5) waist to hip ratio 6) blood glucose levels and 7) blood pressure. Subject V02 Max was assessed using the Rockport submaximal walking test on an indoor track. To assess body composition we determined body mass ratio (BMI), % body fat, % lean body mass and waist to hip ratio. The blood lipid profile included high density lipoprotein, low density lipoprotein and total cholesterol levels; in addition, the ratio of total cholesterol to high density was calculated. Blood triglycerides were also assessed. All data were analyzed using independent t - tests and all data are expressed as mean ± standard error. Statistical significance was accepted at p :S 0.05. Results: Pre-test values for all variables were similar between the experimental and control group. Moreover, although the intervention used in this study was associated with changes in some variables for subjects in the experimental group, subjects in the control group did not exhibit any changes over the same time period. BODY COMPOSITION: The % body fat of experimental subjects decreased by 4.6 ± 0.5%, from 28.1 ± 2.6 to 26.9 ± 2.5 % while that of the control group was unchanged at 22.7 ± 1.4 and 22.2 ± 1.3 %. However, lean body mass of experimental and control subjects did not change at 64.3 ± 1.3 versus 66.1 ± 1.3 kg and 65.5 ± 0.8 versus 64.7 ± 0.8 kg, respectively. In terms of body mass index and waist to hip ratio, neither the experimental nor the control group showed any significant change. Respective values for the waist to hip ratio and body mass index (pre and post) were as follows: 1 ± 0.1 vs 0.9 ± 0.1 (experimental) and 0.9 ± 0.1 versus 0.9 ± 0.1 (controls) while for BMI they were 29 ± 1.4 versus 29 ± 1.2 (experimental) and 26 ± 0.7 vs. 26 ± 0.7 (controls). CARDIORESPIRATORY FITNESS: In the experimental group, predicted values for absolute V02 Max increased by 10 ± 3% (i.e. 3.3 ± 0.1 to 3.6 ± 0.1 liters min -1 while that of control subjects did not change (3.4 ± 0.2 and 3.4 ± 0.2 liters min-I). In terms of relative values for V02 Max, the experimental group increased by 11 ± 2% (37 ± 1.4 to 41 ± 1.4 ml kg-l min-I) while that of control subjects did not change (41 ± 1.4 and 40 ± 1.4 ml kg-l min-I). BLOOD LIPIDS: Compared to pre-test values, post-test values for HDL were decreased by 14 ± 5 % in the experiment group (from 52.4 ± 4.4 to 45.2 ± 4.3 mg dl-l) while HDL data for the control group was unchanged (49.7 ± 3.6 and 48.3 ± 4.1 mg dl-l, respectively. On the other hand, LDL levels did not change for either the experimental or control group (110.2 ± 10.4 versus 112.3 ± 7.1 mg dl-1 and 106.1 ± 11.3 versus 127 ± 15.1 mg dl-1, respectively). Further, total cholesterol did not change in either the experimental or control group (181.3 ± 8.7 mg dl-1 versus 178.7± 4.9 mg dl-l) and 190.7 ± 12.2 versus 197.1 ± 16.1 mg dl-1, respectively). Similarly, the ratio of TC/HDL did not change for either the experimental or control group (3.8 ± 0.4 versus 4.5 ± 0.5 and 4 ± 0.4 versus 4.2 ± 0.4, respectively). Blood triglyceride levels were also not altered in either the experimental or control group (100.3 ± 19.6 versus 114.8 ± 15.3 mg dl-1 and 140 ± 23.5 versus 137.3 ± 17.9 mg dl-l, respectively). BLOOD GLUCOSE: Fasted blood glucose levels did not change in either the experimental or control group. Pre- and post-values for experimental and control groups were 92.5 ± 4.8 versus 93.3 ± 4.3 mg dl-l and 92.3 ± 11.3 versus 93.2 ± 2.6 mg dl-1 , respectively. BLOOD PRESSURE: No aspect of blood pressure was altered in either the experimental or control group. For example, pre- and post-test systolic blood pressures were 131 ± 2 versus 129 ± 2 mmHg (experimental) and 123 ± 2 and 125 ± 2 mmHg (controls), respectively. Pre- and post-test diastolic blood pressures were 84 ± 2 and 83 ± 2 mmHg (experimental) and 81 ± 1 versus 82 ± 1 mmHg, respectively. Similarly, calculated pulse pressure was not altered in the experimental or control as pre- and post-test values were 47 ± 1 versus 47 ± 2 mmlHg and 42 ± 2 versus 43 ± 2 mmHg, respectively. FRAMINGHAM POINT SCORE: The concerted changes reported above produced an increased risk in the Framingham Point Score for the subjects in the experimental group. For example, the pre- and post-test FPS increased from 1.4 ± 0.9 to 2.7 ± 0.7. On the other hand, pre- and post-test scores for the control group were 1.8 ± 1 versus 1.8 ± 0.9. Conclusions: Our data confirms previous studies showing that interval-type exercise is a useful intervention for increasing aerobic fitness. Moreover, the increase in V02 Max we found in response to limited participation in ball hockey (i.e. 16 games) suggests that recreational sport may help reduce this aspect of coronary risk in previously sedentary individual. On the other hand, our results showing little or no positive change in body composition, blood lipids or blood pressures suggest that one season of recreational sport in not in of itself a powerful enough stimulus to reduce the overall risk of coronary artery disease. In light of this, it is recommended that, in addition to participation in recreational sport, the performance of regular physical activity is used as an adjunct to provide a more powerful overall stimulus for decreasing coronary risk factors. LIMITATIONS: The increase in the FPS we found for the experimental group, indicative of an increased risk for coronary disease, was largely due to the large decrease in HDL we observed after compared to above one season of ball hockey. In light of the fact that cardiorespiratory fitness was increased and % body fat was decreased, as well as the fact that other parameters such as blood pressure showed positive (but non statistically significant) trends, the possibility that the decrease in HDL showed by our data was anomalous should be considered. FUTURE DIRECTIONS: The results of this study suggesting that recreational sport may be a potentially useful intervention in the reduction of CAD require to be corroborated by future studies specifically employing 1) more rigorous assessment of fitness and fitness change and 2) more prolonged or frequent participants.
Resumo:
The facial width-to-height ratio (face ratio), is a sexually dimorphic metric associated with actual aggression in men and with observers’ judgements of aggression in male faces. Here, we sought to determine if observers’ judgements of aggression were associated with the face ratio in female faces. In three studies, participants rated photographs of female and male faces on aggression, femininity, masculinity, attractiveness, and nurturing. In Studies 1 and 2, for female and male faces, judgements of aggression were associated with the face ratio even when other cues in the face related to masculinity were controlled statistically. Nevertheless, correlations between the face ratio and judgements of aggression were smaller for female than for male faces (F1,36= 7.43, p= 0.01). In Study 1, there was no significant relationship between judgements of femininity and of aggression in female faces. In Study 2, the association between judgements of masculinity and aggression was weaker in female faces than for male faces in Study 1. The weaker association in female faces may be because aggression and masculinity are stereotypically male traits. Thus, in Study 3, observers rated faces on nurturing (a stereotypically female trait) and on femininity. Judgements of nurturing were associated with femininity (positively) and masculinity (negatively) ratings in both female and male faces. In summary, the perception of aggression differs in female versus male faces. The sex difference was not simply because aggression is a gendered construct; the relationships between masculinity/femininity and nurturing were similar for male and female faces even though nurturing is also a gendered construct. Masculinity and femininity ratings are not associated with aggression ratings nor with the face ratio for female faces. In contrast, all four variables are highly inter-correlated in male faces, likely because these cues in male faces serve as ‘‘honest signals’’.
Resumo:
Différentes méthodes ayant pour objectif une utilisation optimale d'antennes radio-fréquences spécialisées en imagerie par résonance magnétique sont développées et validées. Dans un premier temps, il est démontré qu'une méthode alternative de combinaison des signaux provenant des différents canaux de réception d'un réseau d'antennes mène à une réduction significative du biais causé par la présence de bruit dans des images de diffusion, en comparaison avec la méthode de la somme-des-carrés généralement utilisée. Cette réduction du biais engendré par le bruit permet une amélioration de l'exactitude de l'estimation de différents paramètres de diffusion et de diffusion tensorielle. De plus, il est démontré que cette méthode peut être utilisée conjointement avec une acquisition régulière sans accélération, mais également en présence d'imagerie parallèle. Dans une seconde perspective, les bénéfices engendrés par l'utilisation d'une antenne d'imagerie intravasculaire sont étudiés. Suite à une étude sur fantôme, il est démontré que l'imagerie par résonance magnétique intravasculaire offre le potentiel d'améliorer significativement l'exactitude géométrique lors de mesures morphologiques vasculaires, en comparaison avec les résultats obtenus avec des antennes de surface classiques. Il est illustré qu'une exactitude géométrique comparable à celle obtenue grâce à une sonde ultrasonique intravasculaire peut être atteinte. De plus, plusieurs protocoles basés sur une acquisition de type balanced steady-state free-precession sont comparés dans le but de mettre en évidence différentes relations entre les paramètres utilisés et l'exactitude géométrique obtenue. En particulier, des dépendances entre la taille du vaisseau, le rapport signal-sur-bruit à la paroi vasculaire, la résolution spatiale et l'exactitude géométrique atteinte sont mises en évidence. Dans une même optique, il est illustré que l'utilisation d'une antenne intravasculaire permet une amélioration notable de la visualisation de la lumière d'une endoprothèse vasculaire. Lorsque utilisée conjointement avec une séquence de type balanced steady-state free-precession utilisant un angle de basculement spécialement sélectionné, l'imagerie par résonance magnétique intravasculaire permet d'éliminer complètement les limitations normalement engendrées par l'effet de blindage radio-fréquence de l'endoprothèse.
Resumo:
Cette thèse porte sur l’amélioration des techniques d’imagerie à haut-contraste permettant la détection directe de compagnons à de faibles séparations de leur étoile hôte. Plus précisément, elle s’inscrit dans le développement du Gemini Planet Imager (GPI) qui est un instrument de deuxième génération pour les télescopes Gemini. Cette caméra utilisera un spectromètre à champ intégral (SCI) pour caractériser les compagnons détectés et pour réduire le bruit de tavelure limitant leur détection et corrigera la turbulence atmosphérique à un niveau encore jamais atteint en utilisant deux miroirs déformables dans son système d’optique adaptative (OA) : le woofer et le tweeter. Le woofer corrigera les aberrations de basses fréquences spatiales et de grandes amplitudes alors que le tweeter compensera les aberrations de plus hautes fréquences ayant une plus faible amplitude. Dans un premier temps, les performances pouvant être atteintes à l’aide des SCIs présentement en fonction sur les télescopes de 8-10 m sont investiguées en observant le compagnon de l’étoile GQ Lup à l’aide du SCI NIFS et du système OA ALTAIR installés sur le télescope Gemini Nord. La technique de l’imagerie différentielle angulaire (IDA) est utilisée pour atténuer le bruit de tavelure d’un facteur 2 à 6. Les spectres obtenus en bandes JHK ont été utilisés pour contraindre la masse du compagnon par comparaison avec les prédictions des modèles atmosphériques et évolutifs à 8−60 MJup, où MJup représente la masse de Jupiter. Ainsi, il est déterminé qu’il s’agit plus probablement d’une naine brune que d’une planète. Comme les SCIs présentement en fonction sont des caméras polyvalentes pouvant être utilisées pour plusieurs domaines de l’astrophysique, leur conception n’a pas été optimisée pour l’imagerie à haut-contraste. Ainsi, la deuxième étape de cette thèse a consisté à concevoir et tester en laboratoire un prototype de SCI optimisé pour cette tâche. Quatre algorithmes de suppression du bruit de tavelure ont été testés sur les données obtenues : la simple différence, la double différence, la déconvolution spectrale ainsi qu’un nouvel algorithme développé au sein de cette thèse baptisé l’algorithme des spectres jumeaux. Nous trouvons que l’algorithme des spectres jumeaux est le plus performant pour les deux types de compagnons testés : les compagnons méthaniques et non-méthaniques. Le rapport signal-sur-bruit de la détection a été amélioré d’un facteur allant jusqu’à 14 pour un compagnon méthanique et d’un facteur 2 pour un compagnon non-méthanique. Dernièrement, nous nous intéressons à certains problèmes liés à la séparation de la commande entre deux miroirs déformables dans le système OA de GPI. Nous présentons tout d’abord une méthode utilisant des calculs analytiques et des simulations Monte Carlo pour déterminer les paramètres clés du woofer tels que son diamètre, son nombre d’éléments actifs et leur course qui ont ensuite eu des répercussions sur le design général de l’instrument. Ensuite, le système étudié utilisant un reconstructeur de Fourier, nous proposons de séparer la commande entre les deux miroirs dans l’espace de Fourier et de limiter les modes transférés au woofer à ceux qu’il peut précisément reproduire. Dans le contexte de GPI, ceci permet de remplacer deux matrices de 1600×69 éléments nécessaires pour une séparation “classique” de la commande par une seule de 45×69 composantes et ainsi d’utiliser un processeur prêt à être utilisé plutôt qu’une architecture informatique plus complexe.
Resumo:
Il est bien connu que les enfants qui présentent un trouble de traitement auditif (TTA) ont de la difficulté à percevoir la parole en présence de bruit de fond. Cependant, il n’existe aucun consensus quant à l’origine de ces difficultés d’écoute. Ce programme de recherche est consacré à l’étude des incapacités sous-jacentes aux problèmes de perception de la parole dans le bruit chez les enfants présentant un TTA. Le Test de Phrases dans le Bruit (TPB) a été développé afin d’examiner si les difficultés de perception de la parole dans le bruit d’enfants ayant un TTA relèvent d’incapacités auditives, d’incapacités cognitivo-linguistiques ou des deux à la fois. Il comprend cinq listes de 40 phrases, composées de 20 phrases hautement prévisibles (HP) et de 20 phrases faiblement prévisibles (FP), de même qu’un bruit de verbiage. Le niveau de connaissance du mot clé (mot final) de chaque phrase a été vérifié auprès d’un groupe d’enfants âgés entre 5 et 7 ans. De plus, le degré d’intelligibilité des phrases dans le bruit et le niveau de prévisibilité ont été mesurées auprès d’adultes pour assurer l’équivalence entre les listes. Enfin, le TPB a été testé auprès d’un groupe de 15 adultes et d’un groupe de 69 enfants sans trouble auditif avant de l’administrer à des enfants ayant un TTA. Pour répondre à l’objectif général du programme de recherche, dix enfants présentant un TTA (groupe TTA) et dix enfants jumelés selon le genre et l’âge sans difficulté auditive (groupe témoin) ont été soumis aux listes de phrases du TPB selon différentes conditions sonores. Le groupe TTA a obtenu des performances significativement plus faibles comparativement au groupe témoin à la tâche de reconnaissance du mot final des phrases présentées en même temps qu’un bruit de verbiage compétitif, aux rapports signal-sur-bruit de 0, +3 et +4 dB. La moyenne de la différence des scores obtenue entre les phrases HP et FP à chaque condition expérimentale de bruit était similaire entre les deux groupes. Ces résultats suggèrent que les enfants ayant un TTA ne se distinguent pas des enfants du groupe témoin au plan de la compétence cognitivo-linguistique. L’origine des difficultés d’écoute de la parole dans le bruit dans le cas de TTA serait de nature auditive. Toutefois, les résultats des analyses de groupe diffèrent de ceux des analyses individuelles. Les divers profils de difficultés d’écoute identifiés auprès de cette cohorte appuient l’importance de continuer les investigations afin de mieux comprendre l’origine des problèmes de perception de la parole dans le bruit dans le cas de TTA. En connaissant mieux la nature de ces difficultés, il sera possible d’identifier les stratégies d’intervention de réadaptation spécifiques et efficaces.
Resumo:
L’électrofilage est une technique permettant de fabriquer des fibres polymériques dont le diamètre varie entre quelques nanomètres et quelques microns. Ces fibres ont donc un rapport surface/volume très élevé. Les fibres électrofilées pourraient trouver des applications dans le relargage de médicaments et le génie tissulaire, comme membranes et capteurs chimiques, ou dans les nanocomposites et dispositifs électroniques. L’électrofilage était initialement utilisé pour préparer des toiles de fibres désordonnées, mais il est maintenant possible d’aligner les fibres par l’usage de collecteurs spéciaux. Cependant, il est important de contrôler non seulement l’alignement macroscopique des fibres mais aussi leur orientation au niveau moléculaire puisque l’orientation influence les propriétés mécaniques, optiques et électriques des polymères. Les complexes moléculaires apparaissent comme une cible de choix pour produire des nanofibres fortement orientées. Dans les complexes d’inclusion d’urée, les chaînes polymères sont empilées dans des canaux unidimensionnels construits à partir d’un réseau tridimensionnel de molécules d’urée liées par des ponts hydrogène. Ainsi, les chaînes polymère sonts très allongées à l’échelle moléculaire. Des nanofibres du complexe PEO-urée ont été préparées pour la première fois par électrofilage de suspensions et de solutions. Tel qu’attendu, une orientation moléculaire inhabituellement élevée a été observée dans ces fibres. De tels complexes orientés pourraient être utilisés à la fois dans des études fondamentales et dans la préparation de matériaux hiérarchiquement structurés. La méthode d’électrofilage peut parfois aussi être utilisée pour préparer des matériaux polymériques métastables qui ne peuvent pas être préparés par des méthodes conventionnelles. Ici, l’électrofilage a été utilisé pour préparer des fibres des complexes stables (α) et "métastables" (β) entre le PEO et l’urée. La caractérisation du complexe β, qui était mal connu, révèle un rapport PEO:urée de 12:8 appartenant au système orthorhombique avec a = 1.907 nm, b = 0.862 nm et c = 0.773 nm. Les chaînes de PEO sont orientées selon l’axe de la fibre. Leur conformation est significativement affectée par les ponts hydrogène. Une structure en couches a été suggérée pour la forme β, plutôt que la structure conventionnelle en canaux adoptée par la forme α. Nos résultats indiquent que le complexe β est thermodynamiquement stable avant sa fonte et peut se transformer en forme α et en PEO liquide par un processus de fonte et recristallisation à 89 ºC. Ceci va dans le sens contraire aux observations faites avec le complexe β obtenu par trempe du complexe α fondu. En effet, le complexe β ainsi obtenu est métastable et contient des cristaux d’urée. Il peut subir une transition de phases cinétique solide-solide pour produire du complexe α dans une vaste gamme de températures. Cette transition est induite par un changement de conformation du PEO et par la formation de ponts hydrogène intermoléculaires entre l’urée et le PEO. Le diagramme de phases du système PEO-urée a été tracé sur toute la gamme de compositions, ce qui a permis d’interpréter la formation de plusieurs mélanges qui ne sont pas à l’équilibre mais qui sont été observés expérimentalement. La structure et le diagramme de phases du complexe PEO-thiourée, qui est aussi un complexe très mal connu, ont été étudiés en détail. Un rapport molaire PEO :thiourée de 3:2 a été déduit pour le complexe, et une cellule monoclinique avec a = 0.915 nm, b = 1.888 nm, c = 0.825 nm et β = 92.35º a été déterminée. Comme pour le complexe PEO-urée de forme β, une structure en couches a été suggérée pour le complexe PEO-thiourée, dans laquelle les molécules de thiourée seraient disposées en rubans intercalés entre deux couches de PEO. Cette structure en couches pourrait expliquer la température de fusion beaucoup plus faible des complexes PEO-thiourée (110 ºC) et PEO-urée de forme β (89 ºC) en comparaison aux structures en canaux du complexe PEO-urée de forme α (143 ºC).
Resumo:
Le regroupement des neurones de propriétés similaires est à l’origine de modules permettant d’optimiser l’analyse de l’information. La conséquence est la présence de cartes fonctionnelles dans le cortex visuel primaire de certains mammifères pour de nombreux paramètres tels que l’orientation, la direction du mouvement ou la position des stimuli (visuotopie). Le premier volet de cette thèse est consacré à caractériser l’organisation modulaire dans le cortex visuel primaire pour un paramètre fondamental, la suppression centre / pourtour et au delà du cortex visuel primaire (dans l’aire 21a), pour l’orientation et la direction. Toutes les études ont été effectuées à l’aide de l’imagerie optique des signaux intrinsèques sur le cortex visuel du chat anesthésié. La quantification de la modulation par la taille des stimuli à permis de révéler la présence de modules de forte et de faible suppression par le pourtour dans le cortex visuel primaire (aires 17 et 18). Ce type d’organisation n’avait été observé jusqu’ici que dans une aire de plus haut niveau hiérarchique chez le primate. Une organisation modulaire pour l’orientation, similaire à celle observée dans le cortex visuel primaire a été révélée dans l’aire 21a. Par contre, contrairement à l’aire 18, l’aire 21a ne semblait pas être organisée en domaine de direction. L’ensemble de ces résultats pourront permettre d’alimenter les connaissances sur l’organisation anatomo-fonctionnelle du cortex visuel du chat mais également de mieux comprendre les facteurs qui déterminent la présence d’une organisation modulaire. Le deuxième volet abordé dans cette thèse s’est intéressé à l’amélioration de l’aspect quantitatif apporté par l’analyse temporelle en imagerie optique des signaux intrinsèques. Cette nouvelle approche, basée sur l’analyse de Fourier a permis d’augmenter considérablement le rapport signal / bruit des enregistrements. Toutefois, cette analyse ne s’est basée jusqu’ici que sur la quantification d’une seule harmonique ce qui a limité son emploi à la cartographie de l’orientation et de rétinotopie uniquement. En exploitant les plus hautes harmoniques, un modèle a été proposé afin d’estimer la taille des champs récepteurs et la sélectivité à la direction. Ce modèle a par la suite été validé par des approches conventionnelles dans le cortex visuel primaire.
Resumo:
Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques.