890 resultados para parametric resonances
Resumo:
Human activity-induced vibrations in slender structural sys tems become apparent in many different excitation modes and consequent action effects that cause discomfort to occupants, crowd panic and damage to public infrastructure. Resulting loss of public confidence in safety of structures, economic losses, cost of retrofit and repairs can be significant. Advanced computational and visualisation techniques enable engineers and architects to evolve bold and innovative structural forms, very often without precedence. New composite and hybrid materials that are making their presence in structural systems lack historical evidence of satisfactory performance over anticipated design life. These structural systems are susceptible to multi-modal and coupled excitation that are very complex and have inadequate design guidance in the present codes and good practice guides. Many incidents of amplified resonant response have been reported in buildings, footbridges, stadia a nd other crowded structures with adverse consequences. As a result, attenuation of human-induced vibration of innovative and slender structural systems very ofte n requires special studies during the design process. Dynamic activities possess variable characteristics and thereby induce complex responses in structures that are sensitive to parametric variations. Rigorous analytical techniques are available for investigation of such complex actions and responses to produce acceptable performance in structural systems. This paper presents an overview and a critique of existing code provisions for human-induced vibration followed by studies on the performance of three contrasting structural systems that exhibit complex vibration. The dynamic responses of these systems under human-induced vibrations have been carried out using experimentally validated computer simulation techniques. The outcomes of these studies will have engineering applications for safe and sustainable structures and a basis for developing design guidance.
Resumo:
Numerically investigation of natural convection within a differentially heated modified square enclosure with sinusoidally corrugated side walls has been performed for different values of Rayleigh number. The fluid inside the enclosure considered is air and is quiescent, initially. The top and bottom surfaces are flat and considered as adiabatic. Results reveal three main stages: an initial stage, a transitory or oscillatory stage and a steady stage for the development of natural convection flow inside the corrugated cavity. The numerical scheme is based on the finite element method adapted to triangular non-uniform mesh element by a non-linear parametric solution algorithm. Investigation has been performed for the Rayleigh number, Ra ranging from 105 to 108 with variation of corrugation amplitude and frequency. Constant physical properties for the fluid medium have been assumed. Results have been presented in terms of the isotherms, streamlines, temperature plots, average Nusselt numbers, traveling waves and thermal boundary layer thickness plots, temperature and velocity profiles. The effects of sudden differential heating and its consequent transient behavior on fluid flow and heat transfer characteristics have been observed for the range of governing parameters. The present results show that the transient phenomena are greatly influenced by the variation of the Rayleigh Number with corrugation amplitude and frequency.
Resumo:
We derive a semianalytical model to describe the interaction of a single photon emitter and a collection of arbitrarily shaped metal nanoparticles. The theory treats the metal nanoparticles classically within the electrostatic eigenmode method, wherein the surface plasmon resonances of collections of nanoparticles are represented by the hybridization of the plasmon modes of the noninteracting particles. The single photon emitter is represented by a quantum mechanical two-level system that exhibits line broadening due to a finite spontaneous decay rate. Plasmon-emitter coupling is described by solving the resulting Bloch equations. We illustrate the theory by studying model systems consisting of a single emitter coupled to one, two, and three nanoparticles, and we also compare the predictions of our model to published experimental data. ©2012 American Physical Society.
Resumo:
This paper presents the details of a numerical study of a cold-formed steel beam known as LiteSteel Beam (LSB) subject to combined shear and bending actions. The LSB sections are produced by a patented manufacturing process involving simultaneous cold-forming and electric resistance welding. They have a unique shape of a channel beam with two rectangular hollow flanges. To date, however, no investigation has been conducted into the strength of LSB sections under combined shear and bending actions. Hence a numerical study was undertaken to investigate the behaviour and strength of LSBs subject to combined shear and bending actions. In this research, finite element models of LSBs were developed to simulate the combined shear and bending behaviour and strength of LSBs. They were then validated by comparing their results with test results and used in a parametric study. Both experimental and finite element analysis results showed that the current design equations are not suitable for combined shear and bending capacities of LSBs. Hence improved design equations are proposed for the capacities of LSBs subject to combined shear and bending actions.
Resumo:
Cold-formed steel members are increasingly used as primary structural elements in buildings due to the availability of thin and high strength steels and advanced cold-forming technologies. Cold-formed lipped channel beams (LCB) are commonly used as flexural members such as floor joists and bearers. Shear behaviour of LCBs with web openings is more complicated and their shear capacities are considerably reduced by the presence of web openings. However, limited research has been undertaken on the shear behaviour and strength of LCBs with web openings. Hence a numerical study was undertaken to investigate the shear behaviour and strength of LCBs with web openings. Finite element models of simply supported LCBs with aspect ratios of 1.0 and 1.5 were considered under a mid-span load. They were then validated by comparing their results with test results and used in a detailed parametric study. Experimental and numerical results showed that the current design rules in cold-formed steel structures design codes are very conservative for the shear design of LCBs with web openings. Improved design equations were therefore proposed for the shear strength of LCBs with web openings. This paper presents the details of this numerical study of LCBs with web openings, and the results.
Numerical and experimental studies of cold-formed steel floor systems under standard fire conditions
Resumo:
Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.
Resumo:
There is a need for an accurate real-time quantitative system that would enhance decision-making in the treatment of osteoarthritis. To achieve this objective, significant research is required that will enable articular cartilage properties to be measured and categorized for health and functionality without the need for laboratory tests involving biopsies for pathological evaluation. Such a system would provide the capability of access to the internal condition of the cartilage matrix and thus extend the vision-based arthroscopy that is currently used beyond the subjective evaluation of surgeons. The system required must be able to non-destructively probe the entire thickness of the cartilage and its immediate subchondral bone layer. In this thesis, near infrared spectroscopy is investigated for the purpose mentioned above. The aim is to relate it to the structure and load bearing properties of the cartilage matrix to the near infrared absorption spectrum and establish functional relationships that will provide objective, quantitative and repeatable categorization of cartilage condition outside the area of visible degradation in a joint. Based on results from traditional mechanical testing, their innovative interpretation and relationship with spectroscopic data, new parameters were developed. These were then evaluated for their consistency in discriminating between healthy viable and degraded cartilage. The mechanical and physico-chemical properties were related to specific regions of the near infrared absorption spectrum that were identified as part of the research conducted for this thesis. The relationships between the tissue's near infrared spectral response and the new parameters were modeled using multivariate statistical techniques based on partial least squares regression (PLSR). With significantly high levels of statistical correlation, the modeled relationships were demonstrated to possess considerable potential in predicting the properties of unknown tissue samples in a quick and non-destructive manner. In order to adapt near infrared spectroscopy for clinical applications, a balance between probe diameter and the number of active transmit-receive optic fibres must be optimized. This was achieved in the course of this research, resulting in an optimal probe configuration that could be adapted for joint tissue evaluation. Furthermore, as a proof-of-concept, a protocol for obtaining the new parameters from the near infrared absorption spectra of cartilage was developed and implemented in a graphical user interface (GUI)-based software, and used to assess cartilage-on-bone samples in vitro. This conceptual implementation has been demonstrated, in part by the individual parametric relationship with the near infrared absorption spectrum, the capacity of the proposed system to facilitate real-time, non-destructive evaluation of cartilage matrix integrity. In summary, the potential of the optical near infrared spectroscopy for evaluating articular cartilage and bone laminate has been demonstrated in this thesis. The approach could have a spin-off for other soft tissues and organs of the body. It builds on the earlier work of the group at QUT, enhancing the near infrared component of the ongoing research on developing a tool for cartilage evaluation that goes beyond visual and subjective methods.
Resumo:
Fire safety has become an important part in structural design due to the ever increasing loss of properties and lives during fires. Conventionally the fire rating of load bearing wall systems made of Light gauge Steel Frames (LSF) is determined using fire tests based on the standard time-temperature curve given in ISO 834 (ISO, 1999). The standard time-temperature curve given in ISO 834 (ISO, 1999) originated from the application of wood burning furnaces in the early 1900s. However, modern commercial and residential buildings make use of thermoplastic materials, which mean considerably high fuel loads. Hence a detailed fire research study into the performance of LSF walls was undertaken using the developed real fire curves based on Eurocode parametric curves (ECS, 2002) and Barnett’s BFD curves (Barnett, 2002) using both full scale fire tests and numerical studies. It included LSF walls without any insulation, and the recently developed externally insulated composite panel system. This paper presents the details of the numerical studies and the results. It also includes brief details of the development of real building fire curves and experimental studies.
Resumo:
Abstract. Fire resistance has become an important part in structural design due to the ever increasing loss of properties and lives every year. Conventionally the fire rating of load bearing Light gauge Steel Frame (LSF) walls is determined using standard fire tests based on the time-temperature curve given in ISO 834 [1]. Full scale fire testing based on this standard time-temperature curve originated from the application of wood burning furnaces in the early 1900s and it is questionable whether it truly represents the fuel loads in modern buildings. Hence a detailed fire research study into the performance of LSF walls was undertaken using real design fires based on Eurocode parametric curves [2] and Barnett’s ‘BFD’ curves [3]. This paper presents the development of these real fire curves and the results of full scale experimental study into the structural and fire behaviour of load bearing LSF stud wall systems.
Resumo:
Outdoor workers are exposed to high levels of ultraviolet radiation (UVR) and may thus be at greater risk to experience UVR-related health effects such as skin cancer, sun burn, and cataracts. A number of intervention trials (n=14) have aimed to improve outdoor workers’ work-related sun protection cognitions and behaviours. Only one study however has reported the use of UV-photography as part of a multi-component intervention. This study was performed in the USA and showed long-term (12 months) improvements in work-related sun protection behaviours. Intervention effects of the other studies have varied greatly, depending on the population studied, intervention applied, and measurement of effect. Previous studies have not assessed whether: - Interventions are similarly effective for workers in stringent and less stringent policy organisations; - Policy effect is translated into workers’ leisure time protection; - Implemented interventions are effective in the long-term; - The facial UV-photograph technique is effective in Australian male outdoor workers without a large additional intervention package, and; - Such interventions will also affect workers’ leisure time sun-related cognitions and behaviours. Therefore, the present Protection of Outdoor Workers from Environmental Radiation [POWER]-study aimed to fill these gaps and had the objectives of: a) assessing outdoor workers’ sun-related cognitions and behaviours at work and during leisure time in stringent and less stringent sun protection policy environments; b) assessing the effect of an appearance-based intervention on workers’ risk perceptions, intentions and behaviours over time; c) assessing whether the intervention was equally effective within the two policy settings; and d) assessing the immediate post-intervention effect. Effectiveness was described in terms of changes in sun-related risk perceptions and intentions (as these factors were shown to be main precursors of behaviour change in many health promotion theories) and behaviour. The study purposefully selected and recruited two organisations with a large outdoor worker contingent in Queensland, Australia within a 40 kilometre radius of Brisbane. The two organisations differed in the stringency of implementation and reinforcement of their organisational sun protection policy. Data were collected from 154 male predominantly Australian born outdoor workers with an average age of 37 years and predominantly medium to fair skin (83%). Sun-related cognitions and behaviours of workers were assessed using self-report questionnaires at baseline and six to twelve months later. Variation in follow-up time was due to a time difference in the recruitment of the two organisations. Participants within each organisation were assigned to an intervention or control group. The intervention group participants received a one-off personalised Skin Cancer Risk Assessment Tool [SCRAT]-letter and a facial UV-photograph with detailed verbal information. This was followed by an immediate post-intervention questionnaire within three months of the start of the study. The control group only received the baseline and follow-up questionnaire. Data were analysed using a variety of techniques including: descriptive analyses, parametric and non-parametric tests, and generalised estimating equations. A 15% proportional difference observed was deemed of clinical significance, with the addition of reported statistical significance (p<0.05) where applicable. Objective 1: Assess and compare the current sun-related risk perceptions, intentions, behaviours, and policy awareness of outdoor workers in stringent and less stringent sun protection policy settings. Workers within the two organisations (stringent n=89 and less stringent n=65) were similar in their knowledge about skin cancer, self efficacy, attitudes, and social norms regarding sun protection at work and during leisure time. Participants were predominantly in favour of sun protection. Results highlighted that compared to workers in a less stringent policy organisation working for an organisation with stringent sun protection policies and practices resulted in more desirable sun protection intentions (less willing to tan p=0.03) ; actual behaviours at work (sufficient use of upper and lower body protection, headgear, and sunglasses (p<0.001 for all comparisons), and greater policy awareness (awareness of repercussions if Personal Protective Equipment (PPE) was not used, p<0.001)). However the effect of the work-related sun protection policy was found not to extend to leisure time sun protection. Objective 2: Compare changes in sun-related risk perceptions, intentions, and behaviours between the intervention and control group. The effect of the intervention was minimal and mainly resulted in a clinically significant reduction in work-related self-perceived risk of developing skin cancer in the intervention compared to the control group (16% and 32% for intervention and control group, respectively estimated their risk higher compared to other outdoor workers: , p=0.11). No other clinical significant effects were observed at 12 months follow-up. Objective 3: Assess whether the intervention was equally effective in the stringent sun protection policy organisation and the less stringent sun protection policy organisation. The appearance-based intervention resulted in a clinically significant improvement in the stringent policy intervention group participants’ intention to protect from the sun at work (workplace*time interaction, p=0.01). In addition to a reduction in their willingness to tan both at work (will tan at baseline: 17% and 61%, p=0.06, at follow-up: 54% and 33%, p=0.07, stringent and less stringent policy intervention group respectively. The workplace*time interaction was significant p<0.001) and during leisure time (will tan at baseline: 42% and 78%, p=0.01, at follow-up: 50% and 63%, p=0.43, stringent and less stringent policy intervention group respectively. The workplace*time interaction was significant p=0.01) over the course of the study compared to the less stringent policy intervention group. However, no changes in actual sun protection behaviours were found. Objective 4: Examine the effect of the intervention on level of alarm and concern regarding the health of the skin as well as sun protection behaviours in both organisations. The immediate post-intervention results showed that the stringent policy organisation participants indicated to be less alarmed (p=0.04) and concerned (p<0.01) about the health of their skin and less likely to show the facial UV-photograph to others (family p=0.03) compared to the less stringent policy participants. A clinically significantly larger proportion of participants from the stringent policy organisation reported they worried more about skin cancer (65%) and skin freckling (43%) compared to those in the less stringent policy organisation (46%,and 23% respectively , after seeing the UV-photograph). In summary the results of this study suggest that the having a stringent work-related sun protection policy was significantly related to for work-time sun protection practices, but did not extend to leisure time sun protection. This could reflect the insufficient level of sun protection found in the general Australian population during leisure time. Alternatively, reactance caused by being restricted in personal decisions through work-time policy could have contributed to lower leisure time sun protection. Finally, other factors could have also contributed to the less than optimal leisure time sun protection behaviours reported, such as unmeasured personal or cultural barriers. All these factors combined may have lead to reduced willingness to take proper preventive action during leisure time exposure. The intervention did not result in any measurable difference between the intervention and control groups in sun protection behaviours in this population, potentially due to the long lag time between the implementation of the intervention and assessment at 12-months follow-up. In addition, high levels of sun protection behaviours were found at baseline (ceiling effect) which left little room for improvement. Further, this study did not assess sunscreen use, which was the predominant behaviour assessed in previous effective appearance-based interventions trials. Additionally, previous trials were mainly conducted in female populations, whilst the POWER-study’s population was all male. The observed immediate post-intervention result could be due to more emphasis being placed on sun protection and risks related to sun exposure in the stringent policy organisation. Therefore participants from the stringent policy organisation could have been more aware of harmful effects of UVR and hence, by knowing that they usually protect adequately, not be as alarmed or concerned as the participants from the less stringent policy organisation. In conclusion, a facial UV-photograph and SCRAT-letter information alone may not achieve large changes in sun-related cognitions and behaviour, especially of assessed 6-12 months after the intervention was implemented and in workers who are already quite well protected. Differences found between workers in the present study appear to be more attributable to organisational policy. However, against a background of organisational policy, this intervention may be a useful addition to sun-related workplace health and safety programs. The study findings have been interpreted while respecting a number of limitations. These have included non-random allocation of participants due to pre-organised allocation of participants to study group in one organisation and difficulty in separating participants from either study group. Due to the transient nature of the outdoor worker population, only 105 of 154 workers available at baseline could be reached for follow-up. (attrition rate=32%). In addition the discrepancy in the time to follow-up assessment between the two organisations was a limitation of the current study. Given the caveats of this research, the following recommendations were made for future research: - Consensus should be reached to define "outdoor worker" in terms of time spent outside at work as well as in the way sun protection behaviours are measured and reported. - Future studies should implement and assess the value of the facial UV-photographs in a wide range of outdoor worker organisations and countries. - More timely and frequent follow-up assessments should be implemented in intervention studies to determine the intervention effect and to identify the best timing of booster sessions to optimise results. - Future research should continue to aim to target outdoor workers’ leisure time cognitions and behaviours and improve these if possible. Overall, policy appears to be an important factor in workers’ compliance with work-time use of sun protection. Given the evidence generated by this research, organisations employing outdoor workers should consider stringent implementation and reinforcement of a sun protection policy. Finally, more research is needed to improve ways to generate desirable behaviour in this population during leisure time.
Resumo:
The 2010 LAGI competition was held on three underutilized sites in the United Arab Emirates. By choosing Staten Island, New York in 2012 the competition organises have again brought into question new roles for public open space in the contemporary city. In the case of the UEA sites, the competition produced many entries which aimed to create a sculpture and by doing so, they attracted people to the selected empty spaces in an arid climate. In a way these proposals were the incubators and the new characters of these empty spaces. The competition was thus successful at advancing understandings of the expanded role of public open spaces in EAU and elsewhere. LAGI 2012 differs significantly to the UAE program because Fresh Kills Park has already been planned as a public open space for New Yorkers - with or without these clean energy sculptures. Furthermore, Fresh Kills Park is already an (gas) energy generating site in its own right. We believe Fresh Kills Park, as a site, presents a problem which somewhat transcends the aims of the competition brief. Advancing a sustainable urban design proposition for the site therefore requires a fundamental reconsideration of the established paradigms public open space. Hence our strategy is to not only create an energy generating, site specific art work, but to create synergy between the public and the site engagement while at the same time complement the idiosyncrasies of the pre-existing engineered landscape. Current PhD research about energy generation in public open spaces informs this work.
Resumo:
The Balanced method was introduced as a class of quasi-implicit methods, based upon the Euler-Maruyama scheme, for solving stiff stochastic differential equations. We extend the Balanced method to introduce a class of stable strong order 1. 0 numerical schemes for solving stochastic ordinary differential equations. We derive convergence results for this class of numerical schemes. We illustrate the asymptotic stability of this class of schemes is illustrated and is compared with contemporary schemes of strong order 1. 0. We present some evidence on parametric selection with respect to minimising the error convergence terms. Furthermore we provide a convergence result for general Balanced style schemes of higher orders.
Resumo:
The recent expansion of prediction markets provides a great opportunity to test the market efficiency hypothesis and the calibration of trader judgements. Using a large database of observed prices, this article studies the calibration of prediction markets prices on sporting events using both nonparametric and parametric methods. While only minor bias can be observed during most of the lifetime of the contracts, the calibration of prices deteriorates very significantly in the last moments of the contracts’ lives. Traders tend to overestimate the probability of the losing team to reverse the situation in the last minutes of the game.
Resumo:
Traditional shading design principles guide the vertical and horizontal orientation of fins, louvres and awnings being applied to orthogonal planar façades. Due to doubly curved envelopes characterising many contemporary designs, these rules of thumb are now not always applicable. Operable blinds attempt to regulate the fluctuating luminance of daylight and aid in shading direct sunlight. Mostly they remain closed, as workers are commonly too preoccupied to continually adjust them so a reliance on electrically powered lights remains a preference. To remedy these problems, the idea of what it is to sustainable enclose space is reconsidered through the geometric and kinetic optimisation of a parametric skin, with sunlight responsive modules that regulate interior light levels. This research concludes with an optimised design and also defines some unique metrics to gauge the design’s performance in terms of, the amount of exterior unobstructed view, its ability to shade direct sunlight and, its daylight glare probability.