Fire tests of load bearing steel stud walls exposed to real building fires


Autoria(s): Ariyanayagam, Anthony Deloge; Mahendran, Mahen
Data(s)

06/06/2012

Resumo

Abstract. Fire resistance has become an important part in structural design due to the ever increasing loss of properties and lives every year. Conventionally the fire rating of load bearing Light gauge Steel Frame (LSF) walls is determined using standard fire tests based on the time-temperature curve given in ISO 834 [1]. Full scale fire testing based on this standard time-temperature curve originated from the application of wood burning furnaces in the early 1900s and it is questionable whether it truly represents the fuel loads in modern buildings. Hence a detailed fire research study into the performance of LSF walls was undertaken using real design fires based on Eurocode parametric curves [2] and Barnett’s ‘BFD’ curves [3]. This paper presents the development of these real fire curves and the results of full scale experimental study into the structural and fire behaviour of load bearing LSF stud wall systems.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/53259/

Relação

http://eprints.qut.edu.au/53259/1/SiF2012_Paper.pdf

http://www.ibk.ethz.ch/fo/sif2012/news/index

Ariyanayagam, Anthony Deloge & Mahendran, Mahen (2012) Fire tests of load bearing steel stud walls exposed to real building fires. In 7th International Conference on Structures in Fire, 6 - 8 June 2012, ETH, Zurich,.

http://purl.org/au-research/grants/ARC/DP0986575

Direitos

Copyright 2012 [please consult the author]

Fonte

Science & Engineering Faculty

Palavras-Chave #090506 Structural Engineering #Light gauge steel frames #Load bearing steel stud walls #Real building fires #Fire rating #Cold-formed steel structures #Full scale tests
Tipo

Conference Paper