998 resultados para large segmental defects


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genome-wide association studies (GWAS) have identified more than 100 genetic variants contributing to BMI, a measure of body size, or waist-to-hip ratio (adjusted for BMI, WHRadjBMI), a measure of body shape. Body size and shape change as people grow older and these changes differ substantially between men and women. To systematically screen for age- and/or sex-specific effects of genetic variants on BMI and WHRadjBMI, we performed meta-analyses of 114 studies (up to 320,485 individuals of European descent) with genome-wide chip and/or Metabochip data by the Genetic Investigation of Anthropometric Traits (GIANT) Consortium. Each study tested the association of up to ~2.8M SNPs with BMI and WHRadjBMI in four strata (men ≤50y, men >50y, women ≤50y, women >50y) and summary statistics were combined in stratum-specific meta-analyses. We then screened for variants that showed age-specific effects (G x AGE), sex-specific effects (G x SEX) or age-specific effects that differed between men and women (G x AGE x SEX). For BMI, we identified 15 loci (11 previously established for main effects, four novel) that showed significant (FDR<5%) age-specific effects, of which 11 had larger effects in younger (<50y) than in older adults (≥50y). No sex-dependent effects were identified for BMI. For WHRadjBMI, we identified 44 loci (27 previously established for main effects, 17 novel) with sex-specific effects, of which 28 showed larger effects in women than in men, five showed larger effects in men than in women, and 11 showed opposite effects between sexes. No age-dependent effects were identified for WHRadjBMI. This is the first genome-wide interaction meta-analysis to report convincing evidence of age-dependent genetic effects on BMI. In addition, we confirm the sex-specificity of genetic effects on WHRadjBMI. These results may provide further insights into the biology that underlies weight change with age or the sexually dimorphism of body shape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piikarbidi (SiC) on tunnettu korkealuokkaisena hioma-aineena ja hiekkapaperin pin-noitteena yli 100 vuoden ajan. Nykyisin ainetta käytetään pääasiassa puolijohteiden raaka-aineena. Piikarbidi on puolijohteena ylivoimainen tavanomaiseen piihin (Si) verrattuna lähes joka suhteessa johtuen sen kiderakenteesta, mutta sen valmistus on osoittautunut erittäin monimutkaiseksi johtuen pääasiassa vaikeudesta kasvattaa riittävän suuria ja laadukkaita SiC-kiteitä. Siksi tehoelektroniikan SiC-puolijohdekomponenttien laajamittaista käyttöä joudutaan yhä odottamaan. Tässä diplomityössä tehdään perusteellinen selvitys, miten piikarbidin valmistuspro-sessit eroavat normaaleista piin valmistusprosesseista, mitä etuja piikarbidin käytöllä saavutetaan ja vastaavasti mitä varjopuolia sillä on. Työssä selvitetään tällä hetkellä markkinoilla olevien SiC-tehopuolijohdekomponenttien ominaisuuksia, ketkä ovat teh-neet tutkimusta alalla, sekä esitetään arvioita SiC-tekniikan tulevaisuuden näkymistä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Specifically we aim to demonstrate that the results of our earlier safety data hold true in this much larger multi-national and multi-ethnical population. BACKGROUND: We sought to re-evaluate the frequency, manifestations, and severity of acute adverse reactions associated with administration of several gadolinium- based contrast agents during routine CMR on a European level. METHODS: Multi-centre, multi-national, and multi-ethnical registry with consecutive enrolment of patients in 57 European centres. RESULTS: During the current observation 37,788 doses of Gadolinium based contrast agent were administered to 37,788 patients. The mean dose was 24.7 ml (range 5-80 ml), which is equivalent to 0.123 mmol/kg (range 0.01 - 0.3 mmol/kg). Forty-five acute adverse reactions due to contrast administration occurred (0.12%). Most reactions were classified as mild (43 of 45) according to the American College of Radiology definition. The most frequent complaints following contrast administration were rashes and hives (15 of 45), followed by nausea (10 of 45) and flushes (10 of 45). The event rate ranged from 0.05% (linear non-ionic agent gadodiamide) to 0.42% (linear ionic agent gadobenate dimeglumine). Interestingly, we also found different event rates between the three main indications for CMR ranging from 0.05% (risk stratification in suspected CAD) to 0.22% (viability in known CAD). CONCLUSIONS: The current data indicate that the results of the earlier safety data hold true in this much larger multi-national and multi-ethnical population. Thus, the "off-label" use of Gadolinium based contrast in cardiovascular MR should be regarded as safe concerning the frequency, manifestation and severity of acute events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wiskott-Aldrich syndrome (WAS) is a rare X-linked primary immunodeficiency characterized by recurrent infections, thrombocytopenia, eczema, and high incidence of malignancy and autoimmunity. The cellular mechanisms underlying autoimmune complications in WAS have been extensively studied; however, they remain incompletely defined. We investigated the characteristics of IL-10-producing CD19+CD1dhighCD5+ B cells (CD1dhighCD5+ Breg) obtained from Was gene knockout (WKO) mice and found that their numbers were significantly lower in these mice compared to wild type (WT) controls. Moreover, we found a significant age-dependent reduction of the percentage of IL-10-expressing cells in WKO CD1dhighCD5+ Breg cells as compared to age-matched WT control mice. CD1dhighCD5+ Breg cells from older WKO mice did not suppress the in vitro production of inflammatory cytokines from activated CD4+ T cells. Interestingly, CD1dhighCD5+ Breg cells from older WKO mice displayed a basal activated phenotype which may prevent normal cellular responses, among which is the expression of IL-10. These defects may contribute to the susceptibility to autoimmunity with age in patients with WAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extensive defects of the pelvis and genitoperineal region are a reconstructive challenge. We discuss a consecutive series of 25 reconstructions with the pedicled anterolateral thigh (ALT) flap including muscle part of the vastus lateralis (VL) in 23 patients from October 1999 to September 2012.Only surface defects larger than 100 cm and reconstructions by composite ALT + VL were included in this retrospective analysis. Of the 23 patients, 19 underwent oncologic resection, whereas 4 cases presented Fournier gangrene. Three patients did not reach 6 months of follow-up and were excluded from further data analysis. Among the remaining 20 patients (22 reconstructions), average follow-up period was 14 months (range, 10-18 months). Patient's average age was 60 years. Average size of the defect was 182 cm.Postoperative complications included 1 (4.5%) flap necrosis out of 22 raised flaps, 1 partial flap necrosis after venous congestion, and 2 cases where a complementary reconstructive procedure was performed due to remaining defect or partial flap failure. In 6 cases, peripheral wound dehiscence (27%) was treated by debridement followed by split-thickness skin graft or advancement local flaps. Defect size was significantly related to postoperative complications and increased hospital stay, especially in those patients who underwent preoperative radiotherapy. At the end of the follow-up period, a long-term and satisfactory coverage was obtained in all patients without functional deficits.This consecutive series of composite ALT + VL flap shows that, in case of extended defects, the flap provides an excellent and adjustable muscle mass, is reliable with minimal donor-site morbidity, and can even be designed as a sensate flap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A major threat to the validity of longitudinal cohort studies is non-response to follow-up, which can lead to erroneous conclusions. The objective of this study was to evaluate the profile of non-responders to self-reported questionnaires in the Swiss inflammatory bowel disease (IBD) Cohort. METHODS: We used data from adult patients enrolled between November 2006 and June 2011. Responders versus non-responders were compared according to socio-demographic, clinical and psychosocial characteristics. Odds ratio for non-response to initial patient questionnaire (IPQ) compared to 1-year follow-up questionnaire (FPQ) were calculated. RESULTS: A total of 1943 patients received IPQ, in which 331 (17%) did not respond. Factors inversely associated with non-response to IPQ were age >50 and female gender (OR = 0.37; p < 0.001 respectively OR = 0.63; p = 0.003) among Crohn's disease (CD) patients, and disease duration >16 years (OR = 0.48; p = 0.025) among patients with ulcerative colitis (UC). FPQ was sent to 1586 patients who had completed the IPQ; 263 (17%) did not respond. Risk factors of non-response to FPQ were mild depression (OR = 2.17; p = 0.003) for CD, and mild anxiety (OR = 1.83; p = 0.024) for UC. Factors inversely associated with non-response to FPQ were: age >30 years, colonic only disease location, higher education and higher IBD-related quality of life for CD, and age >50 years or having a positive social support for UC. CONCLUSIONS: Characteristics of non-responders differed between UC and CD. The risk of non-response to repetitive solicitations (longitudinal versus transversal study) seemed to decrease with age. Assessing non-respondents' characteristics is important to document potential bias in longitudinal studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time required to image large samples is an important limiting factor in SPM-based systems. In multiprobe setups, especially when working with biological samples, this drawback can make impossible to conduct certain experiments. In this work, we present a feedfordward controller based on bang-bang and adaptive controls. The controls are based in the difference between the maximum speeds that can be used for imaging depending on the flatness of the sample zone. Topographic images of Escherichia coli bacteria samples were acquired using the implemented controllers. Results show that to go faster in the flat zones, rather than using a constant scanning speed for the whole image, speeds up the imaging process of large samples by up to a 4x factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very large molecular systems can be calculated with the so called CNDOL approximate Hamiltonians that have been developed by avoiding oversimplifications and only using a priori parameters and formulas from the simpler NDO methods. A new diagonal monoelectronic term named CNDOL/21 shows great consistency and easier SCF convergence when used together with an appropriate function for charge repulsion energies that is derived from traditional formulas. It is possible to obtain a priori molecular orbitals and electron excitation properties after the configuration interaction of single excited determinants with reliability, maintaining interpretative possibilities even being a simplified Hamiltonian. Tests with some unequivocal gas phase maxima of simple molecules (benzene, furfural, acetaldehyde, hexyl alcohol, methyl amine, 2,5 dimethyl 2,4 hexadiene, and ethyl sulfide) ratify the general quality of this approach in comparison with other methods. The calculation of large systems as porphine in gas phase and a model of the complete retinal binding pocket in rhodopsin with 622 basis functions on 280 atoms at the quantum mechanical level show reliability leading to a resulting first allowed transition in 483 nm, very similar to the known experimental value of 500 nm of "dark state." In this very important case, our model gives a central role in this excitation to a charge transfer from the neighboring Glu(-) counterion to the retinaldehyde polyene chain. Tests with gas phase maxima of some important molecules corroborate the reliability of CNDOL/2 Hamiltonians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface of MgO/Ag(001) has been studied with density functional theory applied to slabs. We have found that regular MgO films show a small adhesion to the silver substrate, the binding can be increased in off-stoichiometric regimes, either by the presence of O vacancies at the oxide film or by a small excess of O atoms at the interface between the ceramic to the metal. By means of theoretical methods, the scanning tunneling microscopy signatures of these films is also analyzed in some detail. For defect free deposits containing 1 or 2 ML and at low voltages, tunnelling takes place from the surface Ag substrate, and at large positive voltages Mg atoms are imaged. If defects, oxygen vacancies, are present on the surface of the oxide they introduce much easier channels for tunnelling resulting in big protrusions and controlling the shape of the image, the extra O stored at the interface can also be detected for very thin films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cost-efficient genome-scale methodologies to assess DNA-methylation are MethylCap-seq and Illumina's Infinium HumanMethylation450 BeadChips (HM450). Objective information regarding the best-suited methodology for a specific research question is scant. Therefore, we performed a large-scale evaluation on a set of 70 brain tissue samples, i.e. 65 glioblastoma and 5 non-tumoral tissues. As MethylCap-seq coverages were limited, we focused on the inherent capacity of the methodology to detect methylated loci rather than a quantitative analysis. MethylCap-seq and HM450 data were dichotomized and performances were compared using a gold standard free Bayesian modelling procedure. While conditional specificity was adequate for both approaches, conditional sensitivity was systematically higher for HM450. In addition, genome-wide characteristics were compared, revealing that HM450 probes identified substantially fewer regions compared to MethylCap-seq. Although results indicated that the latter method can detect more potentially relevant DNA-methylation, this did not translate into the discovery of more differentially methylated loci between tumours and controls compared to HM450. Our results therefore indicate that both methodologies are complementary, with a higher sensitivity for HM450 and a far larger genome-wide coverage for MethylCap-seq, but also that a more comprehensive character does not automatically imply more significant results in biomarker studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tarkoituksena on kerätä yhteen tiedot kaikista maailmalta löytyvistä ison LOCA:n ulospuhallusvaiheen tutkimiseen käytetyistä koelaitteistoista. Työn tarkoituksena on myös antaa pohjaa päätökselle, onko tarpeellista rakentaa uusi koelaitteisto nesterakenne-vuorovaikutuskoodien laskennan validoimista varten. Ennen varsinaisen koelaitteiston rakentamista olisi tarkoituksenmukaista myös rakentaa pienempi pilottikoelaitteisto, jolla voitaisiin testata käytettäviä mittausmenetelmiä. Sopivaa mittausdataa tarvitaan uusien CFD-koodien ja rakenneanalyysikoodien kytketyn laskennan validoimisessa. Näitä koodeja voidaan käyttää esimerkiksi arvioitaessa reaktorin sisäosien rakenteellista kestävyyttä ison LOCA:n ulospuhallusvaiheen aikana. Raportti keskittyy maailmalta löytyviin koelaitteistoihin, uuden koelaitteiston suunnitteluperusteisiin sekä aiheeseen liittyviin yleisiin asioihin. Raportti ei korvaa olemassa olevia validointimatriiseja, mutta sitä voi käyttää apuna etsittäessä validointitarkoituksiin sopivaa ison LOCA:n ulospuhallusvaiheen koelaitteistoa.